AzTrials
AzTrials

Colorectal AdenomaNCT06859125

Comparisons of Endo-Wing-assisted Colonoscopy Versus Standard Colonoscopy in Improving Adenoma Detection Rate in Symptomatic Patients Suspected of Colorectal Cancer

A study testing Endo-Wing™ (Shangxian Minimal Invasive Inc, China) and Standard Colonoscopy in people with Colorectal Adenoma, run by Universiti Kebangsaan Malaysia Medical Centre at 1 site in Malaysia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Colorectal cancer (CRC) is the most common cancer in Malaysia. Colonoscopy is the gold standard for bowel cancer screening and the diagnosis of bowel pathology. Adenoma detection rate (ADR) is an important intraprocedural quality indicator, where endoscopists with ADR below 20% had ratios for the development of cancer… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Colorectal Adenoma
What is being tested?
Endo-Wing™ (Shangxian Minimal Invasive Inc, China) and Standard Colonoscopy
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
192 participants
Where
1 siteMalaysia
Study dates
1 Sep 2019to 30 Apr 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • All patients who will be undergoing screening, diagnostic, surveillance and therapeutic colonoscopy at the HCTM Endoscopic Unit

Who cannot join

  • Patients with colonic strictures,
  • Patients with active colitis,
  • Patients with known polyposis syndrome,
  • Patients with known severe diverticulosis,
  • Patients with known right hemicolectomy,
  • Patients with colostomy/ileostomy and
  • Patients with poor bowel preparation (Boston Bowel Preparation Scale (BBPS) score of 3 and below ).

Trial locations and contacts

1 site in 1 country.

Malaysia1 site
  • Hospital Canselor Tuanku Muhriz (HCTM)

    Cheras, Kuala Lumpur, 56000

Other trials in Malaysia

About this study

Colorectal cancer (CRC) is the most common cancer in Malaysia. Colonoscopy is the gold standard for bowel cancer screening and the diagnosis of bowel pathology. Adenoma detection rate (ADR) is an important intraprocedural quality indicator, where endoscopists with ADR below 20% had ratios for the development of cancer more than 10 times higher than endoscopists with ADR more than 20%. A low ADR can be due to inferior visualization, especially at locations proximal to colonic folds and flexures.

Endo-Wing™ (Shangxian Minimal Invasive Inc, China) is a medical-grade soft silicone rubber device that is attached to the end of a colonoscope. It has 6 soft wing-like projections that are bendable and pliable, which gives a superior visualization directly from its action of flattening the colonic folds and maintaining the central view of the colonoscope during withdrawal. This can improve the endoscopist's ADR. The purpose of this study is to compare the adenoma detection rate between standard colonoscopy and Endo-Wing™ assisted colonoscopy.

Read the detailed description

This study is a single-centre, non-blinded, randomised control trial done at the Hospital Canselor Tuanku Muhriz (HCTM), UKM. All HCTM patients undergoing screening, diagnostic, surveillance and therapeutic colonoscopy at the HCTM endoscopic suite will be included. The exclusion criteria are patients with colonic strictures, active colitis, known polyposis syndrome, known severe diverticulosis, known right hemicolectomy, patients with colostomy/ileostomy and poor bowel preparation. The study will be performed by 3rd and 4th-year surgical registrars who have completed their compulsory endoscopic training. The surgical review board and medical ethics committee of the Faculty of Medicine, Universiti Kebangsaan Malaysia (UKM) have reviewed and given their approval for this study to be conducted. All patients in this study have signed an informed and written consent.

Patients who arrive at the HCTM endoscopy suite will be seen by medical officers and assessed for eligibility. Patients who are eligible and consented to study participation will be randomly allocated using block randomization into either of 2 groups: a standard colonoscopy or Endo-Wing colonoscopy. A standard protocol of 3 litres polyethylene glycol electrolyte solution will be used as bowel preparation at intervals. Conscious sedation will be administered according to standard protocol (IV Midazolam 3mg and IV Pethidine 25mg), and if the endoscopists deem the patient is in discomfort or pain, then an added dose of IV Midazolam 2mg and IV Pethidine 25mg will be given. Bowel preparation quality will be assessed using the Boston Bowel Preparation Scale (BBPS) during colonoscopy.

All colonoscopies will be performed using Olympus Evis Exera III 90 series or Olympus Evis Lucera 260 series colonoscopes. If a patient is randomized to the Endo-Wing™ group, Endo-Wing™ will be attached to the distal tip of the colonoscope. In both groups, the advancement of colonoscopy will be done according to the standard insertion technique. Surgical registrars will be supervised throughout the procedures by a specialist surgeon. Once the caecum is intubated, the minimum time for withdrawal and examination of colonic mucosa is 6 minutes.

Any adenoma/polyps that are seen will be recorded in terms of their presence, location, size and number. Location will classified according to proximal (caecum till transverse colon) and distal (descending colon till rectum) location. The size of the polyps will be divided into categories of 1-5mm, 6-9mm and more than 10mm. On the other hand, the number of adenomas seen will be divided into 1-2, 3-5 and more than 5 adenomas categories.

Patients will be subsequently reviewed in the HCTM endoscopy suite post-colonoscopy for any immediate adverse effects. Once deemed well, patients will be discharged home and followed up with a telephone call 24 hours after the colonoscopic procedure and subsequently one week later.

Randomization will be carried out using an R package (randomizeR) based on the central block randomization (1:1 ratio) of varying block sizes. The sequence of group assignments for each study participant will not be revealed to the participant recruiter to maintain allocation concealment. For the endoscopists, they will not know the procedures assigned to the participants until the commencement of the colonoscopy.

The primary outcome of this study is the adenoma detection rate (ADR), which is defined as the proportion of colonoscopies with at least one adenoma detected to the total colonoscopies in that group. Secondary outcomes are the distribution of adenomas by location, number of adenomas detected, size of adenomas, caecal intubation rate, the total amount of sedation used and adverse effects.

For sample size calculation, we plan to study the ADR (a proportion), with a one control(s) per experimental subject ratio. The estimated sample size will be calculated using a chi-square test procedure with an independent design based on the power and sample size (PS) software version 3.1.4.2. The study power and type I error rate are fixed at 80% and 0.05 (two-sided), respectively. Based on a recent study using a colonoscope adjunct to improve visualization with an ADR improvement from 28.8% (p0) to 49.1% (p1), with a true difference of 20.3. The calculated sample size is, therefore, 89 patients per arm with a total number of 178 patients. Taking into account a 10-percent drop-out rate, the total number of subjects to be recruited is 99 subjects per group (ntotal = 198 subjects)

For statistical analysis, all the variables will be descriptively summarised using means and standard deviations for continuous variables and frequency and percentage for categorical variables. Comparison of categorical variables, adenoma detection rate and adenoma characteristics will be made using Pearson chi-squared and Fisher's exact tests. A P-value of 0.05 (two-sided) will be used as a significance threshold. Statistical analysis will be performed using IBM SPSS Version 25 software

Being tested
Endo-Wing™ (Shangxian Minimal Invasive Inc, China), Standard Colonoscopy
Keywords
colonoscopy, assisted device, adenoma detection rate, endo-wing

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Endo-Wing™ (Shangxian Minimal Invasive Inc, China)Device

    Endo-Wing™ (Shangxian Minimal Invasive Inc, China) is a medical-grade soft silicone rubber device that is attached at the end of a colonoscope. It has 6 soft wing-like projections that are bendable and pliable, giving the endoscopist a superior visualization directly from its action of flattening the colonic folds and maintaining the central view of the colonoscope during withdrawal. This can improve the endoscopist's ADR.

  • Standard ColonoscopyDevice

    Colonoscopies performed using Olympus Evis Exera III 90 series or Olympus Evis Lucera 260 series colonoscopes without Endo-Wing attached at the tip of the colonoscope

Study groups in NCT06859125
Study groupRoleWhat they receive
Standard ColonoscopyActive comparatorColonoscopies performed using Olympus Evis Exera III 90 series or Olympus Evis Lucera 260 series colonoscopes without Endo-Wing attached at the tip of the colonoscope
Receives: Device: Standard Colonoscopy
Endo-wingExperimentalColonoscopies performed using Olympus Evis Exera III 90 series or Olympus Evis Lucera 260 series colonoscopes with Endo-wing™ (Shangxian Minimal Invasive Inc, China) attached at the distal tip of the scope
Receives: Device: Endo-Wing™ (Shangxian Minimal Invasive Inc, China)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Adenoma Detection Rate (ADR)

    The proportion of colonoscopies with at least one adenoma detected divided by the total number of colonoscopies performed in the particular intervention group

    Measured: From enrollment through study completion, an average of 8 months.

Secondary outcomes (3)
  1. Distribution of adenomas

    The distribution of adenomas by location, number of adenomas detected, size of adenomas

    Measured: From enrollment through study completion, an average of 8 months.

  2. Cecal intubation rate

    The proportions of colonoscopies in which the tip of the colonoscope successfully reaches the cecum (the first part of the large intestine) for both standard colonoscopy and Endo-wing groups. This is verified by clear visualization of cecal landmarks, such as:

    1. Appendiceal orifice (the opening of the appendix)
    2. Ileocecal valve (the valve between the small intestine and the colon)

    Measured: From enrollment through study completion, an average of 8 months.

  3. The extent of additional sedation used

    The proportions of patients receiving additional doses of IV Midazolam 2 mg and IV Pethidine 25 mg (total dose: IV Midazolam 5mg and IV pethidine 50mg)

    Measured: From enrollment through study completion, an average of 8 months.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Mar 2025
  2. Study start1 Sep 2019
  3. Primary completion30 Apr 2020
  4. Study completion30 Apr 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
192 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06859125
Sponsor's protocol ID
FF-2019-355
Status last verified
Feb 2025
First submitted
23 Feb 2025
Last updated
10 Mar 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing Endo-Wing™ (Shangxian Minimal Invasive Inc, China) and Standard Colonoscopy in people with Colorectal Adenoma, run by Universiti Kebangsaan Malaysia Medical Centre at 1 site in Malaysia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Mar 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Malaysia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Adenoma Detection Rate (ADR) (time frame: From enrollment through study completion, an average of 8 months.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Mar 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in