AzTrials
AzTrials

Coronary Artery Bypass Graft SurgeryNCT07035756

Development of an Arterial Pressure Monitoring Set Fixation Apparatus

A study testing Arterial Pressure Monitoring Set Fixation Device in people with Coronary Artery Bypass Graft Surgery, run by Yuzuncu Yil University at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study aims to develop an arterial pressure monitoring set fixation device and evaluate its effectiveness in clinical settings. The device is designed to increase the stability and comfort of arterial pressure monitoring during patient care. Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Coronary Artery Bypass Graft Surgery
What is being tested?
Arterial Pressure Monitoring Set Fixation Device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
1 siteTurkey (Türkiye)
Study dates
27 Jan 2025to 30 Dec 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adult patients aged 18-80 years
  • Patients undergoing arterial catheterization for invasive blood pressure and CVP monitoring
  • Patients able to provide informed consent
  • Hemodynamically stable patients undergoing Coronary Artery Bypass Grafting (CABG)

Who cannot join

  • Patients younger than 18 or older than 80 years
  • Patients with coagulopathy or bleeding disorders
  • Patients with local infection or skin lesions at the catheter insertion site
  • Patients unable to provide informed consent
  • Hemodynamically unstable patients
  • Patients with known allergy to device materials or adhesive tapes

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Van Training and Research Hospital

    Van, 65000

Other trials in Turkey (Türkiye)

About this study

Official title: Development of an Arterial Pressure Monitoring Set Fixation Apparatus and Evaluation of Its Effectiveness

This study aims to develop an arterial pressure monitoring set fixation device and evaluate its effectiveness in clinical settings. The device is designed to increase the stability and comfort of arterial pressure monitoring during patient care. An experimental study will be conducted with patients requiring arterial pressure monitoring. The device's effectiveness will be evaluated by measuring fixation stability and postoperative arterial blood pressure-CVP parameters over 48 hours. The study aims to demonstrate that the new fixation device can improve patient safety and monitoring accuracy compared to the standard method using adhesive tape, thereby contributing to better clinical outcomes.

Read the detailed description

This study focuses on the development of a novel arterial pressure monitoring set fixation device designed to enhance stability and comfort during invasive arterial pressure measurement. The device securely fixes the monitoring set in place, reducing movement and potential complications caused by displacement or discomfort associated with the adhesive tapes currently in use.

An experimental study design will be employed. Sixty patients requiring postoperative invasive arterial pressure monitoring will be included based on predefined inclusion and exclusion criteria. The fixation device will be applied to these patients.

Fixation stability, patient comfort, and hemodynamic parameters, including arterial blood pressure and central venous pressure (CVP), will be measured over a 48-hour postoperative period. The data will be analyzed to evaluate the device's effectiveness in improving monitoring accuracy and patient safety.

Ethical approval has been obtained from the relevant institutional review board, and compliance with human subject protection standards will be maintained throughout the study.

Being tested
Arterial Pressure Monitoring Set Fixation Device
Keywords
Arterial Pressure Monitoring, Fixation Device, Coronary Artery Bypass Graft (CABG), Hemodynamic Monitoring, Postoperative Care

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Arterial Pressure Monitoring Set Fixation DeviceDevice

    A newly developed fixation device designed to securely stabilize the arterial pressure monitoring set, improving patient comfort and reducing device displacement during the postoperative period in patients undergoing coronary artery bypass graft surgery.

Study groups in NCT07035756
Study groupRoleWhat they receive
Arterial Pressure Monitoring Set Fixation Device GroupExperimentalThis group includes patients who will receive the new arterial pressure monitoring set fixation device. The device is applied postoperatively to secure arterial pressure monitoring and improve fixation stability and patient comfort over a 48-hour period.
Receives: Device: Arterial Pressure Monitoring Set Fixation Device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of Invasive Blood Pressure and Central Venous Pressure Measurements

    The accuracy of arterial and central venous pressure measurements obtained using the developed fixation device will be compared to those obtained using standard adhesive tape fixation. Accuracy will be determined by evaluating waveform stability and consistency of numeric readings during patient movement and routine care.

    Measured: Within the first 48 hours of monitoring

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Jun 2025
  2. Study start27 Jan 2025
  3. Primary completion30 Jun 2025
  4. Study completion30 Dec 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Sequential
Model description
Participants will be enrolled sequentially and receive the new arterial pressure monitoring set fixation device. Data on fixation stability, patient comfort, and hemodynamic parameters will be collected over 48 hours postoperatively to assess the device's performance.
Masking
None (open label)
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07035756
Sponsor's protocol ID
2024/08-09
Other IDs
TDK-2024-14774
Status last verified
Jun 2026
First submitted
12 Jun 2025
Last updated
22 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data will not be shared.

Publications

  • Nguyen Y, Bora V. Arterial Pressure Monitoring. 2023 Mar 19. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan-. Available from http://www.ncbi.nlm.nih.gov/books/NBK556127/

    PubMed 32310587

Questions about this trial

What is this clinical trial studying?

A study testing Arterial Pressure Monitoring Set Fixation Device in people with Coronary Artery Bypass Graft Surgery, run by Yuzuncu Yil University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of Invasive Blood Pressure and Central Venous Pressure Measurements (time frame: Within the first 48 hours of monitoring). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07035756, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in