AzTrials
AzTrials

Soft Tissue Sarcoma of the LimbNCT07066774

Biopsy Needle Size in Soft Tissue Sarcoma

A study testing Tru-cut Biopsy with 14 G Needle, Tru-cut Biopsy with 16G tru-cut needle and Tru-cut Biopsy with 18G tru-cut needle in people with Soft Tissue Sarcoma of the Limb, run by Ankara City Hospital Bilkent at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Soft tissue sarcomas (STS) require accurate biopsy for diagnosis, grading, and management decisions. Although tru-cut biopsy is widely used, the optimal needle gauge remains uncertain. Read more about this study

Who is it for?
Any age
Conditions the study is for
Soft Tissue Sarcoma of the Limb
What is being tested?
Tru-cut Biopsy with 14 G Needle, Tru-cut Biopsy with 16G tru-cut needle and Tru-cut Biopsy with 18G tru-cut needle
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteTurkey (Türkiye)
Study dates
3 Feb 2025to 18 Jun 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Patients presenting to the Orthopedic Oncology outpatient clinic at Ankara Bilkent City Hospital with suspected or preliminary findings on physical examination suggesting soft tissue sarcoma.
  • Patients presenting to the Orthopedic Oncology outpatient clinic at Ankara Bilkent City Hospital with suspected or preliminary findings on radiological imaging suggesting soft tissue sarcoma.
  • Patients with soft tissue masses in extremities which require pathological examination

Who cannot join

  • Patients with a prior diagnosis of the existing mass, coagulation disorders, active infection at the tumor site, a history of previous surgery or radiotherapy to the tumor region, medical conditions contraindicating tru-cut biopsy, or those who did not consent to participate after detailed explanation of the study, were excluded.

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Ankara Bilkent City Hospital

    Ankara, Cankaya, 06800

Other trials in Turkey (Türkiye)

About this study

Official title: Diagnostic Accuracy of Different Tru-Cut Needle Sizes in Soft Tissue Sarcomas: A Prospective Blinded Study

Soft tissue sarcomas (STS) require accurate biopsy for diagnosis, grading, and management decisions. Although tru-cut biopsy is widely used, the optimal needle gauge remains uncertain. This study aimed to compare diagnostic accuracy and biopsy concordance rates of 14 G, 16 G, and 18 G tru-cut biopsy needles for extremity STS.

  1. Is there any difference between the diagnostic accuracy measurements of 14G, 16G and 18G tru-cut biopsy needles for diagnosis of soft tissue sarcomas in extremities?
  2. Do tumor size, tumor depth, tumor subtype and histological grade of the tumor affect the "matching score"s of biopsies?
  3. Do tumor size, tumor depth, tumor subtype and histological grade of the tumor affect the biopsy result concordance and/or diagnostic accuracy measurements?
  4. Does needle gauge effect successful tumoral tissue sampling or prediction of histological grade of soft tissue sarcomas?
Read the detailed description

In 2018, the National Comprehensive Cancer Network (NCCN) endorsed core-needle (tru-cut) biopsy as the preferred diagnostic modality for STSs [14]. They recommend obtaining at least three tissue core blocks through a single stab incision on the skin, with a 14-gauge needle, directing the needle along different trajectories. In clinical practice, both 14 G and 16 G cores are commonly used Although multiple tru-cut needle gauges are used in practice, to our knowledge, an ideal and safe biopsy needle that does not sacrife diagnostic performance has not been defined. This is a randomized prospective disagnostic accuracy study. Therefore we prospectively compared numerous variables (tumor size, tumor depth, subtype, histological grade etc.) with biopsy result concordance and diagnostic accuracy of 14 G, 16 G, and 18 G tru-cut needles in samples obtained from the same tumor for each patient with suspected extremity STS, to determine whether an optimal needle gauge exists.

Being tested
Tru-cut Biopsy with 14 G Needle, Tru-cut Biopsy with 16G tru-cut needle, Tru-cut Biopsy with 18G tru-cut needle
Keywords
needle size, soft tissue sarcoma, diagnostic accuracy
Medical subject headings
Sarcoma

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Tru-cut Biopsy with 14 G NeedleDiagnostic test

    Each participant underwent Percutaneous Tru-cut Biopsy with 14G tru-cut needle in a single session procedure. There are no studies to our knowledge to compare samples from the same tumor

  • Tru-cut Biopsy with 16G tru-cut needleDiagnostic test

    Each participant underwent Percutaneous Tru-cut Biopsy with 16 tru-cut needle in a single session procedure. There are no studies to our knowledge to compare samples from the same tumor

  • Tru-cut Biopsy with 18G tru-cut needleDiagnostic test

    Each participant underwent Percutaneous Tru-cut Biopsy with 18G tru-cut needle in a single session procedure. There are no studies to our knowledge to compare samples from the same tumor

Study groups in NCT07066774
Study groupRoleWhat they receive
14G NeedleExperimentalEach patient undergoes a tru-cut biopsy with a 14 G needle, obtaining 5 tissue cores (tumor center, superior, inferior, medial, lateral).
Receives: Diagnostic Test: Tru-cut Biopsy with 14 G Needle
16G NeedleExperimentalEach participant underwent Percutaneous Tru-cut Biopsy with 16G tru-cut needles in a single session procedure and within-subject repeated measuring data is obtained
Receives: Diagnostic Test: Tru-cut Biopsy with 16G tru-cut needle
18G NeedleExperimentalEach participant underwent Percutaneous Tru-cut Biopsy with 16G tru-cut needles in a single session procedure and within-subject repeated measuring data is obtained
Receives: Diagnostic Test: Tru-cut Biopsy with 18G tru-cut needle

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Diagnostic accuracy methods

    Sensitivity, specificity, positive predictive value, negative predictive value, false positive rate and false negative rate was analyzed for 3 different needle sizes

    Measured: From enrollment to the end of study at 4 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Jul 2025
  2. Study start3 Feb 2025
  3. Primary completion1 Jun 2025
  4. Study completion18 Jun 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07066774
Sponsor's protocol ID
E2-25-10025
Status last verified
Jul 2025
First submitted
4 Jul 2025
Last updated
15 Jul 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: IPD will no affect the study results or analysis.

Publications

  • Birgin E, Yang C, Hetjens S, Reissfelder C, Hohenberger P, Rahbari NN. Core needle biopsy versus incisional biopsy for differentiation of soft-tissue sarcomas: A systematic review and meta-analysis. Cancer. 2020 Jan 1;126(9):1917-1928. doi: 10.1002/cncr.32735. Epub 2020 Feb 5.

    PubMed 32022262

Questions about this trial

What is this clinical trial studying?

A study testing Tru-cut Biopsy with 14 G Needle, Tru-cut Biopsy with 16G tru-cut needle and Tru-cut Biopsy with 18G tru-cut needle in people with Soft Tissue Sarcoma of the Limb, run by Ankara City Hospital Bilkent at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Jul 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Diagnostic accuracy methods (time frame: From enrollment to the end of study at 4 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07066774, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jul 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in