AzTrials
AzTrials

Orbital DeformityOrbitalProsthNCT07078162

Accuracy of Fitting Surface of Orbital Prosthesis Constructed by Photogrammetry Scan

A study testing Photogramety Orbital Prosthesis and Conventional impression prosthesis in people with Orbital Deformity, run by Tanta University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Two orbital prosthesis were made to the patient , using two different digital scanning methods to restore the unilateral orbital exentration , the prosthetic devices were made using medical silicon material Read more about this study

Who is it for?
Ages 21 years and older
Conditions the study is for
Orbital Deformity
What is being tested?
Photogramety Orbital Prosthesis and Conventional impression prosthesis
Could I receive a placebo?
No, everyone receives an active treatment
How many people
7 participants
Where
1 siteEgypt
Study dates
23 Jun 2024to 23 Jun 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with Unilateral orbital defect.
  • Complete healing of the defect site with no open wound.
  • At least 1 year passed after the last chemo or radiotherapy dose in patients who receiving this type of treatment

Who cannot join

  • Patient under chemo or radiotherapy due to presence of active tumor.
  • Patient with unhealed

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Faculty of Dentistry Tanta University

    Tanta

Other trials in Egypt

About this study

Official title: Accuracy Of Fitting Surface Of Orbital Prosthesis Constructed By Photogrammetry Scan

Two orbital prosthesis were made to the patient , using two different digital scanning methods to restore the unilateral orbital exentration , the prosthetic devices were made using medical silicon material

Read the detailed description

Statement of problem : Orbital defects which resulted from surgical removal of mucormycosis that caused by corona virus infection lead to several functional, esthetic and psychological problems for the patients.

Aim of the study : Evaluation of the accuracy of fitting surface of orbital prosthesis constructed by photogrammetry scan.

Methods : An orbital prosthesis was made using photogrammetry scanning technique as a method for making digital facial impression to obtain facial 3D model using a high resolution professional camera with image processed through 3DF Zephyr open-source software and the other orbital prosthesis was made using a conventional impression for both the defect and contralateral healthy eye , then scanned with a Degree Of Freedom (DOF) extra oral desktop scanner. 3D models of the defect sites were printed from each scanning method to act as a master cast for the orbital prosthesis fabrication. Accuracy of orbital prosthesis fitting surfaces produced from the two techniques in comparison with a facial scan as a reference scan was assessed through deviation analysis using metrology grade software (Geomagic Control X ).

Being tested
Photogramety Orbital Prosthesis, Conventional impression prosthesis
Keywords
Orbital Prosthesis, Photogrammetry, Impression, 3D printing, Silicone, Accuracy

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Photogramety Orbital ProsthesisOther

    Using 2D photographs to abtain 3D model of orbital defect anatomy

  • Conventional impression prosthesisOther

    Conventional impression to an orbital defect then scaning the impression using desktop scanner

Study groups in NCT07078162
Study groupRoleWhat they receive
1- photogrammetry scan to the defect and healthy sitesOtherCapture photographs of the face including the defective site by profesional camera
Receives: Other: Photogramety Orbital Prosthesis
2- Digital scan of a conventional impression to the defect and healthy sitesOtherDigital scan of a conventional impression to the defect and healthy sites, the impression was taken using silicone rubber impression material, to obtain 3D virtual model using an extraoral desktop scanner.
Receives: Other: Conventional impression prosthesis

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of fitting surface of orbital prosthesis

    Measurements of accuracy:

    Measuring surfaces mesh deviation between the two orbital prosthesis fitting surfaces obtained using two types of scanning methods and a reference facial scan obtained using creality raptor (CR) scanner.

    1. The STL file of the facial scan and the STL files of the two orbital prosthesis fitting surfaces were imported separately to the metrology grade software program( Geomagic control x) .
    2. The STL file of the facial scan was selected and considered to be the reference data , and the STL files of the prosthesis fitting surfaces was selected and considered to be the measured data .
    3. The STL file of the measured data was manually superimposed onto the STL file of the reference data .
    4. A color surface map appeared on the reference data which indicate the directional mesh deviation result between the superimposed scans .
    5. The color map scale was adjusted .

    Measured: Baseline or Day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Jul 2025
  2. Study start23 Jun 2024
  3. Primary completion23 Apr 2025
  4. Study completion23 Jun 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
7 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07078162
Sponsor's protocol ID
Orbital prosthesis
Other IDs
2950729
Acronym
OrbitalProsth
Status last verified
Jun 2025
First submitted
1 Jul 2025
Last updated
22 Jul 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: for the patient privacy

Questions about this trial

What is this clinical trial studying?

A study testing Photogramety Orbital Prosthesis and Conventional impression prosthesis in people with Orbital Deformity, run by Tanta University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 22 Jul 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of fitting surface of orbital prosthesis (time frame: Baseline or Day 1). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Jul 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in