Cardiac SurgeryNCT07087639
Novel Venous Cannula Trial
A study testing Self-expanding Venous Cannula in people with Cardiac Surgery and Heart Surgery, run by Eurosets S.r.l. at 1 site in Italy.
Trial summary
This is a prospective, open-label, single-arm, single-center clinical investigation designed to evaluate the safety and performance of a Novel Venous Cannula during on-pump cardiac surgery requiring transfemoral venous cannulation. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Cardiac Surgery, Heart Surgery, Cardiopulmonary Bypass
- What is being tested?
- Self-expanding Venous Cannula
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 42 participants
- Where
- 1 siteItaly
- Study dates
- 22 Dec 2022to 5 Feb 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age > 18 years
- Informed consent obtained
- Hospitalised patients undergoing transfemoral venous cannulation for on pump cardiac surgery procedure
Who cannot join
- Active bleeding
- Need of ECLS
- Low platelet count (<150,000)
- Any clinical conditions that contra-indicate the anti-coagulation
- Any clinical condition that, in the opinion of the investigator, may interfere with the procedure
- Subjects participating in any other clinical trial or investigation with a medical device within 3 months before Assessment visit
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Safety and Effectiveness Evaluation of Novel MICS Venous Cannula
This is a prospective, open-label, single-arm, single-center clinical investigation designed to evaluate the safety and performance of a Novel Venous Cannula during on-pump cardiac surgery requiring transfemoral venous cannulation. The investigation aims to assess the pressure drop across the cannula during extracorporeal circulation and the incidence of serious adverse events associated with its use. A total of 42 participants will be enrolled.
Read the detailed description
This clinical investigation evaluates a Novel Venous Cannula intended for drainage of venous blood during extracorporeal circulation in cardiac surgery. The cannula is made of polyurethane and includes a flexible metallic mesh that allows it to collapse during insertion and expand in situ. It is designed for single use, sterile, and is introduced using a dedicated insertion kit.
The study is a non-randomized, open-label, monocentric, single-arm investigation involving 42 adult patients undergoing elective cardiac surgery requiring transfemoral venous cannulation. The investigation includes three visits: a screening visit (from Day -7 to Day -1), the procedure day (Day 0), and a follow-up visit at Day 7 ± 3 days.
The primary effectiveness outcome is the mean pressure drop (mm Hg) across the cannula required to maintain the target flow rate during surgery. The primary safety outcome is the number of serious adverse events (SAEs) related to the use of the investigational device.
Secondary outcomes include several efficacy-related parameters (e.g., venous line flow, pump flow, cannula positioning, volume of infusion, cardioplegic solution usage, and others), as well as safety outcomes including mortality, cardiovascular events, and neurological complications at 7 days post-procedure.
There is no control group in this study.
- Conditions
- Cardiac Surgery, Heart Surgery, Cardiopulmonary Bypass, Minimally Invasive Surgical Procedures
- Being tested
- Self-expanding Venous Cannula
- Keywords
- Venous Cannula, Extracorporeal Circulation, Cardiopulmonary Bypass, Cardiac Surgery, Transfemoral Venous Cannulation, Minimally Invasive Cardiac Surgery (MICS), Medical Device, Pressure Drop, Serious Adverse Events (SAE), Device Safety, Device Performance, Open-label Clinical Trial, Single-arm Study, Monocentric Study, Self-expanding Cannula
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Self-expanding Venous CannulaDevice
The intervention consists of a self-expanding venous drainage cannula made of polyurethane and reinforced with a flexible metallic mesh. It is designed for transfemoral insertion during on-pump cardiac surgery, including minimally invasive procedures. Once positioned, the cannula expands to its functional diameter to facilitate efficient blood drainage into the extracorporeal circulation system. The configuration used in this study is 680/730 mm in length, 24 Fr, 3/8" diameter. The device is sterile, single-use, and is inserted once on the day of surgery (Day 0) and removed at the end of the procedure. The cannula is used continuously during cardiopulmonary bypass for a maximum duration of 6 hours and is not reused.
| Study group | Role | What they receive |
|---|---|---|
| Experimental Arm - Novel Self-expanding Venous Cannula | Experimental | Participants in this arm will undergo transfemoral venous cannulation using the Novel Self-expanding Venous Cannula during on-pump cardiac surgery procedures. The investigational device is a single-use, sterile polyurethane cannula reinforced with a flexible metallic mesh that allows self-expansion once deployed into the vessel. The device is intended to facilitate efficient venous drainage as part of the extracorporeal circulation system. The study aims to evaluate the device's performance in terms of pressure drop and safety profile. Receives: Device: Self-expanding Venous Cannula |
What is being measured
The primary outcome is the main question the study is designed to answer.
Effectiveness: the mean pressure drop (mm Hg) to maintain the desired flow rate (L/min) during the standard surgical procedure
Measurement of the mean pressure drop (in millimeters of mercury, mmHg) across the novel venous cannula required to maintain the target blood flow rate (liters per minute) during cardiopulmonary bypass in cardiac surgery patients.
Measured: During the surgical procedure (Day 0)
Safety: the number of SAE with the Novel Venous Cannula during the standard surgical procedure
Number of serious adverse events (SAEs) occurring during the surgical procedure that are related or possibly related to the use of the novel venous cannula, including device-related complications, cardiovascular events, and other procedure-associated serious adverse events.
Measured: From Day 0 (procedure day) to 7 days post-procedure
Secondary outcomes (19)
Venous Line Flow During Extracorporeal Circulation Unit of Measure: mL/min
Measurement of venous line flow during CPB to assess the drainage efficiency of the novel venous cannula.
Measured: During the surgical procedure (Day 0)
Mean pump flow during extracorporeal circulation Unit of Measure: L/min/m²
Mean Pump Flow Indexed to Body Surface Area During CPB
Measured: During the surgical procedure (Day 0)
Number of cannulae in the surgical field during surgical procedure Unit of Measure: Count (number)
Number of Cannulae Positioned in the Surgical Field
Measured: During the surgical procedure (Day 0)
Number of cannula tip displacement as detected by TTE/TEE during surgical procedure Unit of Measure: n (%)
Number of Cannula Tip Displacements Detected by TTE/TEE
Measured: During the surgical procedure (Day 0)
Mean increase in free Hb measure during surgical procedure Unit of Measure: mg/dL
Mean Increase in Free Hemoglobin Levels
Measured: During the surgical procedure (Day 0)
Mean volume of infusion during surgical procedure Unit of Measure: mL
Mean Volume of Infusion Administered
Measured: During the surgical procedure (Day 0)
Mean volume of cardioplegic solution Unit of Measure: mL
Mean Volume of Cardioplegic Solution Administered
Measured: During the surgical procedure (Day 0)
Mean speed of aspirators during surgical procedure Unit of Measure: mL/min
Mean Speed of Aspirators Used
Measured: During the surgical procedure (Day 0)
Mean percentage of pump flow increase due to the patient's metabolic needs Unit of Measure: %
Mean Percentage Increase in Pump Flow Due to Metabolic Needs
Measured: During the surgical procedure (Day 0)
Mean volume of recovery blood re-administered during surgical procedure Unit of Measure: mL
Mean Volume of Recovery Blood Re-Administered
Measured: During the surgical procedure (Day 0)
Number of patients for whom blood concentrator was used Unit of Measure: Count (number of patients)
Number of Patients for Whom a Blood Concentrator Was Used
Measured: During the surgical procedure (Day 0)
Presence of echocardiographic abnormalities Unit of Measure: n (%)
Presence of echocardiographic abnormalities
Measured: During the surgical procedure (Day 0)
Number of correctly delivery and deployed Novel Venous Cannula Unit of Measure: Count (number of cannulae)
Number of Novel Venous Cannulae Correctly Delivered and Deployed
Measured: During the surgical procedure (Day 0)
Number of technical success without procedural SAE Unit of Measure: n (%)
Number of patients in which the device was used successfully without the occurrence of procedural serious adverse events during the procedure.
Measured: During the surgical procedure (Day 0)
Number of deaths at 7 days after procedure Unit of Measure: Count (number of patients)
Number of patients who die within 7 days following the surgical procedure involving the use of the novel venous cannula.
Measured: From Day 0 (procedure day) to 7 days post-procedure
Number of cardiovascular deaths at 7 days after procedure Unit of Measure: Count (number of patients)
Number of patients who experience cardiovascular-related death within 7 days following the surgical procedure.
Measured: From Day 0 (procedure day) to 7 days post-procedure
Number of cardiovascular SAEs at 7 days after procedure Unit of Measure: Count (number of patients)
Number of cardiovascular-related serious adverse events (SAEs) occurring within 7 days after the procedure.
Measured: From Day 0 (procedure day) to 7 days post-procedure
Number of stroke at 7 days after procedure Unit of Measure: Count (number of patients)
Number of patients experiencing a clinically confirmed stroke within 7 days following the procedure.
Measured: From Day 0 (procedure day) to 7 days post-procedure
Number minor neurological disorder at 7 days after procedure Unit of Measure: Count (number of patients)
Number of patients experiencing minor neurological disorders within 7 days following the procedure.
Measured: From Day 0 (procedure day) to 7 days post-procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Jul 2025
- Study start22 Dec 2022
- Primary completion5 Feb 2025
- Study completion5 Feb 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (18)Papers the sponsor has linked to this study.
- Other trials for Cardiac SurgeryStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Open-label, non-randomized, monocentric, one arm clinical investigation with pre-marked medical device
- Masking
- None (open label)
- Enrolment
- 42 participants (actual)
Sponsor and investigators
- Lead sponsor
- Eurosets S.r.l.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07087639
- Sponsor's protocol ID
- DE-51-20
- Status last verified
- Jul 2025
- First submitted
- 7 Jul 2025
- Last updated
- 28 Jul 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: De-identified individual participant data (IPD) may be made available to qualified researchers upon reasonable request to the Sponsor, after study completion and publication of the primary results. Each request will be reviewed on a case-by-case basis in accordance with applicable data protection laws, including the EU General Data Protection Regulation (GDPR) 2016/679, and ethical considerations. Access will be granted through a controlled process to ensure the protection of participant confidentiality.
Publications
Von Segesser. Venous drainage is key for CPB. The royal Society of Medicine, London. 28th November 2008
von Segesser LK, Ferrari E, Delay D, Maunz O, Horisberger J, Tozzi P. Routine use of self-expanding venous cannulas for cardiopulmonary bypass: benefits and pitfalls in 100 consecutive cases. Eur J Cardiothorac Surg. 2008 Sep;34(3):635-40. doi: 10.1016/j.ejcts.2008.05.037. Epub 2008 Jul 16.
PubMed 18635371Van Praet KM, Kofler M, Meyer A, Sundermann SH, Hommel M, Falk V, Kempfert J. Single-Center Experience With a Self-Expandable Venous Cannula During Minimally Invasive Cardiac Surgery. Innovations (Phila). 2022 Nov-Dec;17(6):491-498. doi: 10.1177/15569845221131534. Epub 2022 Oct 30.
PubMed 36314445Stoney WS. Evolution of cardiopulmonary bypass. Circulation. 2009 Jun 2;119(21):2844-53. doi: 10.1161/CIRCULATIONAHA.108.830174. No abstract available.
PubMed 19487602Savini C, Gliozzi G, Martin-Suarez S, Zardin D, Mariani C, Cavalli GG, Folesani G, Pacini D. Femoral Venous Cannulation for Minimally Invasive Surgery: Three Years Experience with Wall-less, Self-expandable Cannula. The International Society for Minimally Invasive Cardiothoracic Surgery 2021, PC110.
Pinon M, Pradas G, Molina D, Legarra JJ. Use of self-expanding venous cannula in tricuspid reoperation. Eur J Cardiothorac Surg. 2015 Sep;48(3):499-501. doi: 10.1093/ejcts/ezu492. Epub 2015 Jan 9.
PubMed 25575788Mueller XM, Mallabiabrena I, Mucciolo G, von Segesser LK. Optimized venous return with a self-expanding cannula: from computational fluid dynamics to clinical application. Interact Cardiovasc Thorac Surg. 2002 Sep;1(1):23-7. doi: 10.1016/s1569-9293(02)00006-3.
PubMed 17669950Puis L, Milojevic M, Boer C, De Somer FMJJ, Gudbjartsson T, van den Goor J, Jones TJ, Lomivorotov V, Merkle F, Ranucci M, Kunst G, Wahba A; EACTS/EACTA/EBCP Committee Reviewers. 2019 EACTS/EACTA/EBCP guidelines on cardiopulmonary bypass in adult cardiac surgery. Interact Cardiovasc Thorac Surg. 2020 Feb 1;30(2):161-202. doi: 10.1093/icvts/ivz251. No abstract available.
PubMed 31576402Jegger D, Chassot PG, Bernath MA, Horisberger J, Gersbach P, Tozzi P, Delay D, von Segesser LK. A novel technique using echocardiography to evaluate venous cannula performance perioperatively in CPB cardiac surgery. Eur J Cardiothorac Surg. 2006 Apr;29(4):525-9. doi: 10.1016/j.ejcts.2005.12.050. Epub 2006 Feb 14.
PubMed 16476552Jegger D, Horisberger J, Boone Y, Seigneuil I, Jachertz M, Holzmann I, von Segesser LK. Vascular access for cardiopulmonary bypass procedures. Artif Organs. 2004 Jul;28(7):649-54. doi: 10.1111/j.1525-1594.2004.07372.x.
PubMed 15209858Jegger D, Corno AF, Mucciolo A, Mucciolo G, Boone Y, Horisberger J, Seigneul I, Jachertz M, von Segesser LK. A prototype paediatric venous cannula with shape change in situ. Perfusion. 2003 Mar;18(1):61-5. doi: 10.1191/0267659103pf640oa.
PubMed 12705652Ismail A, Semien G, Sharma S, Collier SA, Miskolczi SY. Cardiopulmonary Bypass. 2024 Aug 12. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan-. Available from http://www.ncbi.nlm.nih.gov/books/NBK482190/
PubMed 29489210Gravlee GP, Davis RF, Kurusz M, Utley JR. Cardiopulmonary Bypass. 2nd Edition. Eugene A, Hessel II, Aaron G. Hill. Chapter 5: circuitry and cannulation - 2016
Frederick A, Hensley Jr, Martin DE, Gravlee G. A Practical Approach to Cardiac Anesthesia. 3rd Edition. 2011; Larach DR, Gibbs NM. Chapter 7. Anesthetic Management During Cardiopulmonary Bypass
Hessel EA 2nd. A Brief History of Cardiopulmonary Bypass. Semin Cardiothorac Vasc Anesth. 2014 Jun;18(2):87-100. doi: 10.1177/1089253214530045. Epub 2014 Apr 10.
PubMed 24728884
Study at a glance
From the registry record, last updated by the sponsor on 28 Jul 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Safety and Effectiveness Evaluation of Novel MICS Venous Cannula
- ClinicalTrials.gov ID
- NCT07087639
- Acronym / sponsor ID
- DE-51-20
- Conditions
- Cardiac Surgery, Heart Surgery, Cardiopulmonary Bypass, Minimally Invasive Surgical Procedures
- Keywords
- Venous Cannula, Extracorporeal Circulation, Cardiopulmonary Bypass, Cardiac Surgery, Transfemoral Venous Cannulation, Minimally Invasive Cardiac Surgery (MICS), Medical Device, Pressure Drop
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 42 participants (actual)
- Lead sponsor
- Eurosets S.r.l.Industry (pharma, biotech, devices)
- Study start
- 22 Dec 2022 (actual)
- Primary completion
- 5 Feb 2025 (actual)
- Study completion
- 5 Feb 2025 (actual)
- First posted
- 28 Jul 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a prospective, open-label, single-arm, single-center clinical investigation designed to evaluate the safety and performance of a Novel Venous Cannula during on-pump cardiac surgery requiring transfemoral venous cannulation. The investigation aims to assess the pressure drop across the cannula during extracorporeal circulation and the incidence of serious adverse events associated with its use. A total of 42 participants will be enrolled.
Detailed description
This clinical investigation evaluates a Novel Venous Cannula intended for drainage of venous blood during extracorporeal circulation in cardiac surgery. The cannula is made of polyurethane and includes a flexible metallic mesh that allows it to collapse during insertion and expand in situ. It is designed for single use, sterile, and is introduced using a dedicated insertion kit.
The study is a non-randomized, open-label, monocentric, single-arm investigation involving 42 adult patients undergoing elective cardiac surgery requiring transfemoral venous cannulation. The investigation includes three visits: a screening visit (from Day -7 to Day -1), the procedure day (Day 0), and a follow-up visit at Day 7 ± 3 days.
The primary effectiveness outcome is the mean pressure drop (mm Hg) across the cannula required to maintain the target flow rate during surgery. The primary safety outcome is the number of serious adverse events (SAEs) related to the use of the investigational device.
Secondary outcomes include several efficacy-related parameters (e.g., venous line flow, pump flow, cannula positioning, volume of infusion, cardioplegic solution usage, and others), as well as safety outcomes including mortality, cardiovascular events, and neurological complications at 7 days post-procedure.
There is no control group in this study.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Open-label, non-randomized, monocentric, one arm clinical investigation with pre-marked medical device
| Arm | Type | Receives |
|---|---|---|
| Experimental Arm - Novel Self-expanding Venous Cannula | Experimental | Device: Self-expanding Venous CannulaParticipants in this arm will undergo transfemoral venous cannulation using the Novel Self-expanding Venous Cannula during on-pump cardiac surgery procedures. The investigational device is a single-use, sterile polyurethane cannula reinforced with a flexible metallic mesh that allows self-expansion once deployed into the vessel. The device is intended to facilitate efficient venous drainage as part of the extracorporeal circulation system. The study aims to evaluate the device's performance in terms of pressure drop and safety profile. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Age > 18 years
- Informed consent obtained
- Hospitalised patients undergoing transfemoral venous cannulation for on pump cardiac surgery procedure
Key exclusion criteria (6 listed)
- Active bleeding
- Need of ECLS
- Low platelet count (<150,000)
- Any clinical conditions that contra-indicate the anti-coagulation
- Any clinical condition that, in the opinion of the investigator, may interfere with the procedure
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Self-expanding Venous CannulaThe intervention consists of a self-expanding venous drainage cannula made of polyurethane and reinforced with a flexible metallic mesh. It is designed for transfemoral insertion during on-pump cardiac surgery, including minimally invasive procedures. Once positioned, the cannula expands to its functional diameter to facilitate efficient blood drainage into the extracorporeal circulation system. The configuration used in this study is 680/730 mm in length, 24 Fr, 3/8" diameter. The device is sterile, single-use, and is inserted once on the day of surgery (Day 0) and removed at the end of the procedure. The cannula is used continuously during cardiopulmonary bypass for a maximum duration of 6 hours and is not reused. | Device | Experimental Arm - Novel Self-expanding Venous Cannula |
Primary outcome
Effectiveness: the mean pressure drop (mm Hg) to maintain the desired flow rate (L/min) during the standard surgical procedure
Time frame: During the surgical procedure (Day 0)
Measurement of the mean pressure drop (in millimeters of mercury, mmHg) across the novel venous cannula required to maintain the target blood flow rate (liters per minute) during cardiopulmonary bypass in cardiac surgery patients.
Safety: the number of SAE with the Novel Venous Cannula during the standard surgical procedure
Time frame: From Day 0 (procedure day) to 7 days post-procedure
Number of serious adverse events (SAEs) occurring during the surgical procedure that are related or possibly related to the use of the novel venous cannula, including device-related complications, cardiovascular events, and other procedure-associated serious adverse events.
19 secondary outcomes
Venous Line Flow During Extracorporeal Circulation Unit of Measure: mL/min
Time frame: During the surgical procedure (Day 0)
Mean pump flow during extracorporeal circulation Unit of Measure: L/min/m²
Time frame: During the surgical procedure (Day 0)
Number of cannulae in the surgical field during surgical procedure Unit of Measure: Count (number)
Time frame: During the surgical procedure (Day 0)
Number of cannula tip displacement as detected by TTE/TEE during surgical procedure Unit of Measure: n (%)
Time frame: During the surgical procedure (Day 0)
Mean increase in free Hb measure during surgical procedure Unit of Measure: mg/dL
Time frame: During the surgical procedure (Day 0)
Mean volume of infusion during surgical procedure Unit of Measure: mL
Time frame: During the surgical procedure (Day 0)
Mean volume of cardioplegic solution Unit of Measure: mL
Time frame: During the surgical procedure (Day 0)
Mean speed of aspirators during surgical procedure Unit of Measure: mL/min
Time frame: During the surgical procedure (Day 0)
Mean percentage of pump flow increase due to the patient's metabolic needs Unit of Measure: %
Time frame: During the surgical procedure (Day 0)
Mean volume of recovery blood re-administered during surgical procedure Unit of Measure: mL
Time frame: During the surgical procedure (Day 0)
Number of patients for whom blood concentrator was used Unit of Measure: Count (number of patients)
Time frame: During the surgical procedure (Day 0)
Presence of echocardiographic abnormalities Unit of Measure: n (%)
Time frame: During the surgical procedure (Day 0)
Number of correctly delivery and deployed Novel Venous Cannula Unit of Measure: Count (number of cannulae)
Time frame: During the surgical procedure (Day 0)
Number of technical success without procedural SAE Unit of Measure: n (%)
Time frame: During the surgical procedure (Day 0)
Number of deaths at 7 days after procedure Unit of Measure: Count (number of patients)
Time frame: From Day 0 (procedure day) to 7 days post-procedure
Number of cardiovascular deaths at 7 days after procedure Unit of Measure: Count (number of patients)
Time frame: From Day 0 (procedure day) to 7 days post-procedure
Number of cardiovascular SAEs at 7 days after procedure Unit of Measure: Count (number of patients)
Time frame: From Day 0 (procedure day) to 7 days post-procedure
Number of stroke at 7 days after procedure Unit of Measure: Count (number of patients)
Time frame: From Day 0 (procedure day) to 7 days post-procedure
Number minor neurological disorder at 7 days after procedure Unit of Measure: Count (number of patients)
Time frame: From Day 0 (procedure day) to 7 days post-procedure
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 28 Jul 2025.
- BackgroundVon Segesser. Venous drainage is key for CPB. The royal Society of Medicine, London. 28th November 2008
- Background: PubMed 18635371von Segesser LK, Ferrari E, Delay D, Maunz O, Horisberger J, Tozzi P. Routine use of self-expanding venous cannulas for cardiopulmonary bypass: benefits and pitfalls in 100 consecutive cases. Eur J Cardiothorac Surg. 2008 Sep;34(3):635-40. doi: 10.1016/j.ejcts.2008.05.037. Epub 2008 Jul 16.
- Background: PubMed 36314445Van Praet KM, Kofler M, Meyer A, Sundermann SH, Hommel M, Falk V, Kempfert J. Single-Center Experience With a Self-Expandable Venous Cannula During Minimally Invasive Cardiac Surgery. Innovations (Phila). 2022 Nov-Dec;17(6):491-498. doi: 10.1177/15569845221131534. Epub 2022 Oct 30.
- Background: PubMed 19487602Stoney WS. Evolution of cardiopulmonary bypass. Circulation. 2009 Jun 2;119(21):2844-53. doi: 10.1161/CIRCULATIONAHA.108.830174. No abstract available.
- BackgroundSavini C, Gliozzi G, Martin-Suarez S, Zardin D, Mariani C, Cavalli GG, Folesani G, Pacini D. Femoral Venous Cannulation for Minimally Invasive Surgery: Three Years Experience with Wall-less, Self-expandable Cannula. The International Society for Minimally Invasive Cardiothoracic Surgery 2021, PC110.
- Background: PubMed 25575788Pinon M, Pradas G, Molina D, Legarra JJ. Use of self-expanding venous cannula in tricuspid reoperation. Eur J Cardiothorac Surg. 2015 Sep;48(3):499-501. doi: 10.1093/ejcts/ezu492. Epub 2015 Jan 9.
- Background: PubMed 17669950Mueller XM, Mallabiabrena I, Mucciolo G, von Segesser LK. Optimized venous return with a self-expanding cannula: from computational fluid dynamics to clinical application. Interact Cardiovasc Thorac Surg. 2002 Sep;1(1):23-7. doi: 10.1016/s1569-9293(02)00006-3.
- Background: PubMed 31576402Puis L, Milojevic M, Boer C, De Somer FMJJ, Gudbjartsson T, van den Goor J, Jones TJ, Lomivorotov V, Merkle F, Ranucci M, Kunst G, Wahba A; EACTS/EACTA/EBCP Committee Reviewers. 2019 EACTS/EACTA/EBCP guidelines on cardiopulmonary bypass in adult cardiac surgery. Interact Cardiovasc Thorac Surg. 2020 Feb 1;30(2):161-202. doi: 10.1093/icvts/ivz251. No abstract available.
- Background: PubMed 16476552Jegger D, Chassot PG, Bernath MA, Horisberger J, Gersbach P, Tozzi P, Delay D, von Segesser LK. A novel technique using echocardiography to evaluate venous cannula performance perioperatively in CPB cardiac surgery. Eur J Cardiothorac Surg. 2006 Apr;29(4):525-9. doi: 10.1016/j.ejcts.2005.12.050. Epub 2006 Feb 14.
- Background: PubMed 15209858Jegger D, Horisberger J, Boone Y, Seigneuil I, Jachertz M, Holzmann I, von Segesser LK. Vascular access for cardiopulmonary bypass procedures. Artif Organs. 2004 Jul;28(7):649-54. doi: 10.1111/j.1525-1594.2004.07372.x.
- Background: PubMed 12705652Jegger D, Corno AF, Mucciolo A, Mucciolo G, Boone Y, Horisberger J, Seigneul I, Jachertz M, von Segesser LK. A prototype paediatric venous cannula with shape change in situ. Perfusion. 2003 Mar;18(1):61-5. doi: 10.1191/0267659103pf640oa.
- Background: PubMed 29489210Ismail A, Semien G, Sharma S, Collier SA, Miskolczi SY. Cardiopulmonary Bypass. 2024 Aug 12. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2026 Jan-. Available from http://www.ncbi.nlm.nih.gov/books/NBK482190/
- Individual participant dataSharing planned: Yes. De-identified individual participant data (IPD) may be made available to qualified researchers upon reasonable request to the Sponsor, after study completion and publication of the primary results. Each request will be reviewed on a case-by-case basis in accordance with applicable data protection laws, including the EU General Data Protection Regulation (GDPR) 2016/679, and ethical considerations. Access will be granted through a controlled process to ensure the protection of participant confidentiality.
Related trials for Cardiac Surgery
RecruitingPhase 2/3
Gabapentin to Reduce Opioid Use Postoperatively (GROUP) in Children
Pain, Postoperative
Active, not recruiting
Comparing Different Regional Blocks for Analgesia After Off-pump Cardiac Surgery
Analgesia
Recruiting
ARTIST: Aortic Regurgitation Trial Investigating Surgery Versus Trilogy™
Aortic Regurgitation, Aortic Valve Insufficiency
Not yet recruiting
Boyle-Davis Mouth Gag Timing in Pediatric Tonsil Surgery
Tonsillectomy and Adenotonsillectomy in Children
Active, not recruiting
Low Tidal Volume Ventilation With Hyperoxia Avoidance During Cardiopulmonary Bypass (The FOCUS Trial)
Cardiac Surgery
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Self-expanding Venous Cannula in people with Cardiac Surgery and Heart Surgery, run by Eurosets S.r.l. at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 28 Jul 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Effectiveness: the mean pressure drop (mm Hg) to maintain the desired flow rate (L/min) during the standard surgical procedure (time frame: During the surgical procedure (Day 0)). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07087639, which also lists 18 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Jul 2025.