AzTrials
AzTrials

Atril FibrillationPERFECT-PAFNCT07100834

Pulsed ElectRic FiEld Versus Cryoballoon for PAF

A study testing Single-Shot Pulsed Field Ablation (FARAPULSE™ Pulsed Field Ablation System) and Single-Shot Cryoballoon Devices (Arctic Front Advance PRO, Medtronic Inc., Minneapolis, MN, USA; POLARx and POLARx FIT Balloon Catheter, Marlborough, MA, USA) in people with Atril Fibrillation and Cardiac Arrhythmia, run by Universitair Ziekenhuis Brussel at 6 sites in 5 countries.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study has been designed to compare the success rate of two different commercially available ablation technologies, namely PFA and Cryo. Both technologies are standard of care ablation procedures. An ablation is a procedure where a small piece of tissue of the heart, that. Read more about this study

Who is it for?
Ages 18 to 75 years
What is being tested?
Single-Shot Pulsed Field Ablation (FARAPULSE™ Pulsed Field Ablation System) and Single-Shot Cryoballoon Devices (Arctic Front Advance PRO, Medtronic Inc., Minneapolis, MN, USA; POLARx and POLARx FIT Balloon Catheter, Marlborough, MA, USA)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
269 participants
Where
6 sitesin 5 countries
Study dates
27 Sep 2023to 30 Jun 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Diagnosis of recurrent symptomatic non-valvular paroxysmal AF (PAF);
  • Age 18 through 75 years-old on the day of enrollment;
  • Willing and capable of providing written informed consent;
  • Willing and capable of complying with all pre-, post- and follow-up testing andrequirements.

Who cannot join

  • AF secondary to electrolyte imbalance, thyroid disease, valvular disease, or reversible or non-cardiac cause;
  • Previous left atrium (LA) ablation or surgery;
  • Previously diagnosed with persistent AF (greater than [>] 7 days in duration);
  • Severe dilatation of the LA (LAD >50 millimeter (mm) antero-posterior diameter in case of transthoracic echocardiography (TTE));
  • Pregnant or lactating (current or anticipated) at the time of catheter ablation;
  • Current enrollment in any other study protocol where testing or results from that study may interfere with the procedure or outcome measurements for this study;
  • Any other conditions such as, mental illness, addictive disease, terminal illness with a life expectancy of less than two years, extensive travel away from the research center that may lead to non-compliance with the protocol procedure or follow up.

Trial locations and contacts

6 sites in 5 countries.

6 sites in 5 countries

Italy2 sites
  • Maria Cecilia Hospital

    Cotignola

  • Ospedale Fatebenefratelli Isola Tiberina-Gemelli Isola

    Roma

Other trials in Italy

Belgium1 site
  • Universitair Ziekenhuis Brussel

    Brussels

Other trials in Belgium

Croatia1 site
  • Department of Cardiovascular Diseases, University Hospital Center Zagreb

    Zagreb

Other trials in Croatia

Greece1 site
  • 9. First Department of Cardiology, National and Kapodistrian University of Athens Medical School, Hippokration General Hospital

    Athens

Other trials in Greece

Poland1 site
  • Department of Cardiology, Medical University of Lublin

    Lublin

Other trials in Poland

About this study

Official title: Pulsed ElectRic FiEld Versus Cryoballoon to Treat Paroxysmal Atrial Fibrillation (PERFECT-PAF) Randomized Trial

This study has been designed to compare the success rate of two different commercially available ablation technologies, namely PFA and Cryo. Both technologies are standard of care ablation procedures. An ablation is a procedure where a small piece of tissue of the heart, that. causes an irregular heartbeat, is heated or frozen (cryo-ablation) using a special type of catheter.

Once you have signed this consent to take part of the study, you will be randomly assigned to one of the two ablation strategies (PFA versus Cryo). Randomization is a method that helps prevent any possible influence of human choices on clinical results and improve objectivity in research. The day of the procedure you will be undergo AF catheter ablation via either PFA or Cryo based on the results of randomization.

Although both devices that will be used in this study are commercially approved, assessing the incidence of arrhythmia recurrence after ablation during follow-up is considered the investigational portion of the study. "Investigational" means that recurrence data will be collected after the cardiac ablation procedure and compared amongst the two standard of care ablation methods used to treat AF. This study will investigate how well PFA and Cryo work to prevent recurrences of atrial arrhythmias and if there are any differences between the two technologies

Read the detailed description

AF is the most common sustained arrhythmia, substantially increasing morbidity and mortality, in addition of being a significant burden on healthcare systems worldwide. During the last decades, catheter ablation with radiofrequency (RF) energy has emerged as an alternative non-pharmacological therapy for AF patients who are intolerant to AADs.2 Catheter ablation is currently the most effective rhythm control strategy;3 its rationale lies in the elimination of atrial sites involved in AF initiation/maintenance. Specifically, studies have demonstrated a critical role of pulmonary veins (PVs) as a source of ectopic beats triggering AF paroxysms and that isolation of PVs (PVI) from the left atrium effectively prevents atrial tachyarrhythmia relapse in paroxysmal AF patients. In addition to point-by-point isolation, PVI can also be achieved with single-shot technologies (e.g., cryoballoon, RF balloon, laser balloon), which have been developed aiming at simplifying the procedure and minimizing the influence of operator's experience on procedural safety and success.

Cryoballoon ablation is currently the most widespread single-shot technique for PVI. Its safety and efficacy has been demonstrated to be superior to antiarrhythmic drug treatment4,5 and non-inferior to RF-based point-by-point PVI in randomized and non-randomized trials.

Both RF and cryothermy rely on thermal processes (heating or freezing, respectively) for cardiac tissue death induction. Despite significant technological improvements and a better understanding of the biophysics of thermal ablation, the main shortcoming of these techniques is the lack of tissue selectivity. Achieving contiguous, transmural cardiac lesions may be associated to an increased risk of collateral damage to surrounding tissues (e.g., phrenic nerve, esophagus, blood vessels).

PFA has emerged as a novel ablation technology, which involves the application of ultrarapid (microseconds to nanoseconds), high-amplitude electrical pulses. These pulses generate strong electric fields with an increase in cell membrane permeability and impaired cell homeostasis, which may promote cell death. In this perspective, PFA differs from the above-mentioned thermal energy sources since it does not rely on thermal processes to achieve ablation. Moreover, the treatment protocol can be designed to overcome/limit the risk of collateral tissue damage and improve cardiac lesion durability.

To date, the only PFA device with regulatory approval (CE-mark) is the multielectrode Farawave catheter (FarapulseTM-Boston Scientific Inc., Marlborough, Massachusetts, USA). The safety and efficacy of the system has been tested in two phase 3 studies enrolling paroxysmal and persistent AF patients, which demonstrated remarkable safety and lesion durability results. Similar observations were confirmed in multiple subsequent post-approval registries.

In addition, the safety and efficacy of the pentaspline FarapulseTM PFA catheter has been reported in several registries12,14, as well as a recent randomized study10 comparing this new technology versus traditional energy sources (e.g. radiofrequency and cryothermy). Our group has been actively involved since the earliest stages of the release of the Farapulse technology. We are one of the two sites worldwide to have all three approved PFA technologies. Our center experience with the FarapulseTM technology includes >600 atrial fibrillation procedures. All operators involved in the trial have performed at least 50 PFA cases and are considered opinion leaders in the field and with the technology.

Nonetheless, no data currently exist directly comparing the safety and long-term efficacy of single-shot PFA versus cryoballoon ablation. This study is designed to compare the well-established approach of cryoballoon ablation with the novel PFA-based single-shot Farapulse device for PVI of PAF in a randomized fashion.

Being tested
Single-Shot Pulsed Field Ablation (FARAPULSE™ Pulsed Field Ablation System), Single-Shot Cryoballoon Devices (Arctic Front Advance PRO, Medtronic Inc., Minneapolis, MN, USA; POLARx and POLARx FIT Balloon Catheter, Marlborough, MA, USA)
Keywords
atrial fibrillation, ablation, pulsed field ablation, cryoablation, cryoballoon, paroxysmal atrial fibrillation
Medical subject headings
Arrhythmias, Cardiac, Atrial Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Single-Shot Pulsed Field Ablation (FARAPULSE™ Pulsed Field Ablation System)Device

    The FARAPULSE™ Pulsed Field Ablation System (Boston Scientific, Inc.) is a CE-marked system consisting of the FARASTAR™ Pulsed Field Ablation Generator that is used with the FARAWAVE™ Pulsed Field Ablation Catheter for cardiac tissue ablation

  • Single-Shot Cryoballoon Devices (Arctic Front Advance PRO, Medtronic Inc., Minneapolis, MN, USA; POLARx and POLARx FIT Balloon Catheter, Marlborough, MA, USA)Device

    The Arctic Front Advance PRO, POLARx and FIT Balloon Catheters are CE-marked cryoablation systems consisting of a cryoballoon device, which is used in conjunction with a CryoConsole, a steerable sheath, and a circular mapping catheter

Study groups in NCT07100834
Study groupRoleWhat they receive
Pulsed Field AblationExperimentalThe FARAPULSE™ Pulsed Field Ablation System (Boston Scientific, Inc.) is a CE-marked system consisting of the FARASTAR™ Pulsed Field Ablation Generator that is used with the FARAWAVE™ Pulsed Field Ablation Catheter for cardiac tissue ablation
Receives: Device: Single-Shot Pulsed Field Ablation (FARAPULSE™ Pulsed Field Ablation System)
Cryoballoon AblationActive comparatorThe Arctic Front Advance PRO, POLARx and Polarx FIT Balloon Catheters are CE-marked cryoablation systems consisting of a cryoballoon device, which is used in conjunction with a CryoConsole, a steerable sheath, and a circular mapping catheter
Receives: Device: Single-Shot Cryoballoon Devices (Arctic Front Advance PRO, Medtronic Inc., Minneapolis, MN, USA; POLARx and POLARx FIT Balloon Catheter, Marlborough, MA, USA)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Primary Efficacy Endpoint

    the primary efficacy endpoint will be the incidence of any atrial tachyarrhythmia (AF, atrial flutter, atrial tachycardia) lasting >30s during at least 1 year of follow-up. Recurrences occurring within the first 90 days post-ablation (the so-called "blanking period") will not be considered for primary efficacy endpoint measurement.

    Measured: 0-36 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Aug 2025
  2. Study start27 Sep 2023
  3. Primary completion30 May 2024
  4. Study completion30 Jun 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
This is a singlecenter, prospective, randomized, non-inferiority, parallel-group, investigator-initiated trial with blinded endpoint assessment in which up to 202 paroxysmal AF patients will be randomly assigned to receive cryoballoon (Group Cryo; n=101) or pulsed electric field (PEF)-(Group PFA; n=101) ablation for pulmonary vein isolation (PVI).
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
269 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07100834
Sponsor's protocol ID
EC-2023-208
Acronym
PERFECT-PAF
Status last verified
Jul 2025
First submitted
27 Jul 2025
Last updated
3 Aug 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

A study testing Single-Shot Pulsed Field Ablation (FARAPULSE™ Pulsed Field Ablation System) and Single-Shot Cryoballoon Devices (Arctic Front Advance PRO, Medtronic Inc., Minneapolis, MN, USA; POLARx and POLARx FIT Balloon Catheter, Marlborough, MA, USA) in people with Atril Fibrillation and Cardiac Arrhythmia, run by Universitair Ziekenhuis Brussel at 6 sites in 5 countries.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 3 Aug 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 6 sites in Italy, Belgium, Croatia, Greece, Poland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Primary Efficacy Endpoint (time frame: 0-36 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Aug 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in