Gait DisordersPhase 4NCT07147543
Effectiveness and Safety of Electrically Powered Orthopedic Exercise Device for Gait Disorders
A Phase 4 study testing Electrically Powered Orthopedic Exercise Device in people with Gait Disorders, run by Yonsei University at 1 site in South Korea.
Trial summary
Aging is a global trend, and consequently, the prevalence of age-related diseases is increasing. Gait disorders are common among the elderly and can result not only from various underlying conditions affecting gait but also from the decline in physiological and neurological functions associated with the normal aging… Read more about this study
- Who is it for?
- Ages 19 years and older
- Conditions the study is for
- Gait Disorders
- What is being tested?
- Electrically Powered Orthopedic Exercise Device
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 30 participants
- Where
- 1 siteSouth Korea
- Study dates
- 7 Apr 2025to 6 Apr 2026
- Phase
- Phase 4
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 19 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adults aged 19 years or older
- Patients experiencing subjective gait or balance disorders
- Individuals who visited Yongin Severance Hospital, understood the study, voluntarily agreed to participate, and signed the consent form
- Patients with a Functional Ambulatory Category (FAC) score of less than 4
- Individuals who can sit on the edge of a bed without assistance and stand for 10 seconds with or without support
- Individuals with sufficient cognitive ability to follow and understand simple instructions (Mini-Mental State Examination score ≥ 20)
Who cannot join
- Individuals with contraindications to weight-bearing in the lower extremities, such as severe lower extremity joint contractures, osteoporosis, or untreated fractures
- Individuals who cannot wear the device due to skin diseases or open wounds
- Individuals with a significant discrepancy in lower extremity length
- Individuals with severe lower extremity deformities or joint contractures
- Individuals unable to maintain a sitting or standing posture independently
- Individuals with severe cognitive impairment (Mini-Mental State Examination score < 20), delirium, or severe speech impairment preventing cooperation in wearing the device
Show all 9Show fewer
- Individuals unable to stand or walk for extended periods due to underlying conditions such as orthostatic hypotension or reduced cardiopulmonary function
- Pregnant or potentially pregnant individuals
- Individuals with other clinically significant conditions deemed inappropriate for this study by the principal investigator or research team based on medical judgment
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
South Korea1 site, 1 recruiting
- Recruiting
Yongin Severance Hospital
Yongin-si, Gyeonggi-do, South Korea, 16995
Na Young Kim, +82 010 9127 4482, kny8452@yuhs.ac
Hwi Woo Yang, +82 010 7360 4439, Rehab5@yuhs.ac
About this study
Official title: Study to Verify the Effectiveness and Safety of the Electrically Powered Orthopedic Exercise Device on Gait Ability in Patients With Gait Disorders : Investigator-Initiated, Single-Center, Single-Group Clinical Trial
Aging is a global trend, and consequently, the prevalence of age-related diseases is increasing. Gait disorders are common among the elderly and can result not only from various underlying conditions affecting gait but also from the decline in physiological and neurological functions associated with the normal aging process.
Gait is a fundamental daily activity that requires the coordinated integration of the central and peripheral nervous systems, as well as the musculoskeletal system. Therefore, impairments in any of these systems-including the nervous, cardiovascular, respiratory, or musculoskeletal systems-can lead to gait dysfunction. Gait disorders negatively impact quality of life by increasing the risk of falls, reducing the ability to perform activities of daily living (ADLs), and limiting physical activity. Accordingly, various approaches to maintaining and improving gait function in older adults are being actively explored.
Read more
Currently, gait aids such as canes and walkers are commonly used to support individuals with gait impairments. These devices help redistribute body weight by providing a broader base of support, thereby assisting with balance and stability. However, they do not directly facilitate the movement of the lower limbs. To enhance gait function, numerous studies have investigated repetitive lower-limb movement training using bicycles or robotic devices. However, the extent of functional improvement resulting from such training remains unclear, and the long-term efficacy is still uncertain.
Recent advancements in sensing technology for joint motion and actuator efficiency have led to the development of wearable assistive devices that are significantly more compact and lightweight compared to conventional robotic systems. This study aims to evaluate the effectiveness of a newly developed electrically powered orthopedic exercise device in patients with gait disorders by assessing changes in gait parameters upon wearing the device, thereby exploring its clinical feasibility.
Read the detailed description
(1) Overview of study design This investigator-initiated exploratory study is a pilot study designed to evaluate the effectiveness and safety of the Electrically Powered Orthopedic Exercise Device by measuring and analyzing gait function and balance ability in patients with gait disorders under both non-wearing and wearing conditions.
(2) Experimental Group and Evaluation Procedures
- Participant Selection: This study includes a single test group with a total of 30 participants. The selection of participants for the electrically powered orthopedic exercise device and the overall study process will be conducted under the prescription and guidance of a rehabilitation medicine specialist, and supervised by assistants (physicians and occupational therapists). The examiner will collect clinical information and conduct a screening assessment for each participant.
- Evaluation Phase Without Device: After the screening test, participants undergo assessments of walking ability and balance without wearing the motorized orthopedic exercise device. A 10-minute rest period is provided between each assessment. If the participant wishes, additional rest time is allowed and recorded in the case report form. The assessments include the 10-Meter Walk Test, the 6-Minute Walk Test, the Timed Up and Go Test, and the Berg Balance Scale. These evaluations are conducted in the rehabilitation function testing room on the second floor of the facility under the supervision of the research team (physician and either a physical or occupational therapist).
- Pre-Adaptation Phase: After the evaluations without the device, a total of four adaptation sessions are conducted, during which the participant wears the device and performs short-distance walking within 10 meters. These sessions are designed to help the participant become familiar with the operation and wearing method of the H10 device. Appropriate device settings are configured for each participant to minimize any potential inexperience or anxiety during use. Participants must complete all four adaptation sessions, and each session should be conducted within a two-week interval.
- Evaluation Phase:
After completing all four adaptation sessions, participants undergo assessments of walking ability and balance while wearing the motorized orthopedic exercise device. A 10-minute rest period is provided between each assessment. If the participant wishes, additional rest time is allowed and recorded in the case report form. The assessments include the 10-Meter Walk Test, the 6-Minute Walk Test, the Timed Up and Go Test, and the Berg Balance Scale. These evaluations are conducted in the rehabilitation function testing room on the second floor of the facility under the supervision of the research team (physician and either a physical or occupational therapist). After the evaluations are completed, a usability and satisfaction survey regarding the motorized orthopedic exercise device is conducted.
- Conditions
- Gait Disorders
- Being tested
- Electrically Powered Orthopedic Exercise Device
- Keywords
- Rehabilitation, Gait, Wearable robot, Gait Disorders
- Medical subject headings
- Mobility Limitation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Electrically Powered Orthopedic Exercise DeviceDevice
Participants who pass the screening undergo an evaluation of gait function and balance ability without wearing the Electrically Powered Orthopedic Exercise Device. Afterward, the patient wears the motorized orthopedic exercise device for a total of four adaptation sessions. In each session, the patient performs short-distance walking within 10 meters while wearing the device to explore the appropriate assistive mode and level of support that match their physical condition. No evaluations are conducted while wearing the device during sessions 1, 2, and 3. After the 4th session, an evaluation identical to the one conducted without the device is performed while wearing it, and a satisfaction survey is conducted.
| Study group | Role | What they receive |
|---|---|---|
| Wearing conditions of Electrically Powered Orthopedic Exercise Device | Experimental | Participants will undergo gait and balance function tests under both non-wearing and wearing conditions of the electrically powered orthopedic exercise device Receives: Device: Electrically Powered Orthopedic Exercise Device |
What is being measured
The primary outcome is the main question the study is designed to answer.
10-Meter Walk Test
Patients are instructed to walk 14 m, including 2 m at both ends for acceleration and deceleration, at their comfortable speed. Gait speed was calculated by dividing the 10m distance by the time taken.
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Secondary outcomes (9)
Timed Up and Go (TUG) Test
Researchers ask patients to rise from a seated position, walk a distance of 3 m, turn around, return to the chair, and sit back. The average time of three trials was recorded as a result
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
6-Minute Walk Test
Patients are instructed to walk back and forth along the 30-meter path as many times as possible within 6 minutes. The examiner records the total distance covered, abnormal gait patterns, and the time of occurrence of any gait deviations.
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Berg balance scale (BBS)
Patients are asked to perform 14 tasks regarding the static and dynamic balance of patients. Each task was rated on a five-point scale from 0 to 4, with a total score of 56.
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Total Step Count
While the participant performs the test wearing an insole-type gait analyzer, spatiotemporal gait parameters are collected and recorded.
Total Step Count: The total number of steps taken during walking.
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Cadence
While the participant performs the test wearing an insole-type gait analyzer, spatiotemporal gait parameters are collected and recorded.
Cadence: The number of steps taken per minute, measured in steps per minute (spm).
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Self-Selected Walking Speed
While the participant performs the test wearing an insole-type gait analyzer, spatiotemporal gait parameters are collected and recorded.
Self-Selected Walking Speed: The participant's walking speed when walking naturally at a comfortable pace.
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Distance
While the participant performs the test wearing an insole-type gait analyzer, spatiotemporal gait parameters are collected and recorded.
Distance: The total distance covered during walking, measured in meters (m).
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Stride Length
While the participant performs the test wearing an insole-type gait analyzer, spatiotemporal gait parameters are collected and recorded.
Stride Length: The distance between the heel of one foot to the heel of the same foot during consecutive steps. Measured in meters (m), stride length is adjusted for height to account for differences in body size.
Measured: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Satisfaction evaluation
Participants will complete a satisfaction survey for usability and satisfaction assessment of the electrically powered orthopedic exercise device, based on the Korean version of the Quebec User Evaluation of Satisfaction with assistive Technology (K-QUEST 2.0).21 This survey consists of 12 items on a 5-point scale. Participants rate their satisfaction with the assistive device and related services.
(An average score of 4 or higher will be interpreted as positive satisfaction, an average score of 2 or lower will be interpreted as negative satisfaction)
Measured: Upon completion of the end-point assessment conducted on the same day as session 4
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 Aug 2025
- Study start7 Apr 2025
- Primary completion6 Apr 2026 (estimated)
- Study completion6 Apr 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (21)Papers the sponsor has linked to this study.
- Other trials for Gait DisordersStudies of the same condition, open and under way.
- More trials run by Yonsei UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 4
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Researchers will compare non-wearing and wearing conditions of the electrically powered orthopedic exercise device walking speeds, spatiotemporal parameters, balance, and satisfaction survey in participants and does not establish a control group.
- Masking
- None (open label)
- Enrolment
- 30 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Yonsei University
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Na Young Kim, MD, PhD, Principal investigator, Severance Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07147543
- Sponsor's protocol ID
- 9-2025-0021
- Status last verified
- Aug 2025
- First submitted
- 21 Apr 2025
- Last updated
- 29 Aug 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Perera S, Mody SH, Woodman RC, Studenski SA. Meaningful change and responsiveness in common physical performance measures in older adults. J Am Geriatr Soc. 2006 May;54(5):743-9. doi: 10.1111/j.1532-5415.2006.00701.x.
PubMed 16696738Podsiadlo D, Richardson S. The timed "Up & Go": a test of basic functional mobility for frail elderly persons. J Am Geriatr Soc. 1991 Feb;39(2):142-8. doi: 10.1111/j.1532-5415.1991.tb01616.x.
PubMed 1991946Lee, Sang-Heon, Bong-Keun Jung, and So-Yeon Park. "Korean Translation and Psychometric Properties of Quebec User Evaluation of Satisfaction Assistive Technology 2.0." Journal of the Korea Academia-Industrial Cooperation Society. The Korea Academia-Industrial Cooperation Society, July 31, 2013.
Bang DH, Shin WS. Effects of robot-assisted gait training on spatiotemporal gait parameters and balance in patients with chronic stroke: A randomized controlled pilot trial. NeuroRehabilitation. 2016 Apr 6;38(4):343-9. doi: 10.3233/NRE-161325.
PubMed 27061162Godi M, Franchignoni F, Caligari M, Giordano A, Turcato AM, Nardone A. Comparison of reliability, validity, and responsiveness of the mini-BESTest and Berg Balance Scale in patients with balance disorders. Phys Ther. 2013 Feb;93(2):158-67. doi: 10.2522/ptj.20120171. Epub 2012 Sep 27.
PubMed 23023812Guyatt GH, Sullivan MJ, Thompson PJ, Fallen EL, Pugsley SO, Taylor DW, Berman LB. The 6-minute walk: a new measure of exercise capacity in patients with chronic heart failure. Can Med Assoc J. 1985 Apr 15;132(8):919-23.
PubMed 3978515Dolny DG, Collins MG, Wilson T, Germann ML, Davis HP. Validity of lower extremity strength and power utilizing a new closed chain dynamometer. Med Sci Sports Exerc. 2001 Jan;33(1):171-5. doi: 10.1097/00005768-200101000-00026.
PubMed 11194105Kim Heon-tae, Moon Jun-bae, Ryu Seung-ho, and Kang Min-soo. Validity study of the Korean version of the International Physical Activity Questionnaire (IPAQ): Verification of construct-related validity. Korean Journal of Physical Education No. 2017;56
Gajdosik RL, Bohannon RW. Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. Phys Ther. 1987 Dec;67(12):1867-72. doi: 10.1093/ptj/67.12.1867.
PubMed 3685114Mehrholz J, Wagner K, Rutte K, Meissner D, Pohl M. Predictive validity and responsiveness of the functional ambulation category in hemiparetic patients after stroke. Arch Phys Med Rehabil. 2007 Oct;88(10):1314-9. doi: 10.1016/j.apmr.2007.06.764.
PubMed 17908575Cuthbert SC, Goodheart GJ Jr. On the reliability and validity of manual muscle testing: a literature review. Chiropr Osteopat. 2007 Mar 6;15:4. doi: 10.1186/1746-1340-15-4.
PubMed 17341308Kang Y, NA D-L, Hahn S. A validity study on the Korean Mini-Mental State Examination (K-MMSE) in dementia patients. Journal of the Korean neurological association 1997:300-308
Tao Y, Luo J, Tian J, Peng S, Wang H, Cao J, Wen Z, Zhang X. The role of robot-assisted training on rehabilitation outcomes in Parkinson's disease: a systematic review and meta-analysis. Disabil Rehabil. 2024 Sep;46(18):4049-4067. doi: 10.1080/09638288.2023.2266178. Epub 2023 Oct 11.
PubMed 37818694Chou CH, Hwang CL, Wu YT. Effect of exercise on physical function, daily living activities, and quality of life in the frail older adults: a meta-analysis. Arch Phys Med Rehabil. 2012 Feb;93(2):237-44. doi: 10.1016/j.apmr.2011.08.042.
PubMed 22289232Sudarsky L. Gait disorders: prevalence, morbidity, and etiology. Adv Neurol. 2001;87:111-7. No abstract available.
PubMed 11347214
Study at a glance
From the registry record, last updated by the sponsor on 29 Aug 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Study to Verify the Effectiveness and Safety of the Electrically Powered Orthopedic Exercise Device on Gait Ability in Patients With Gait Disorders : Investigator-Initiated, Single-Center, Single-Group Clinical Trial
- ClinicalTrials.gov ID
- NCT07147543
- Acronym / sponsor ID
- 9-2025-0021
- Conditions
- Gait Disorders
- Keywords
- Rehabilitation, Gait, Wearable robot, Gait Disorders
- Phase
- Phase 4
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 30 participants (estimated)
- Lead sponsor
- Yonsei UniversityUniversity, hospital or other
- Study start
- 7 Apr 2025 (actual)
- Primary completion
- 6 Apr 2026 (estimated)
- Study completion
- 6 Apr 2026 (estimated)
- First posted
- 29 Aug 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Aging is a global trend, and consequently, the prevalence of age-related diseases is increasing. Gait disorders are common among the elderly and can result not only from various underlying conditions affecting gait but also from the decline in physiological and neurological functions associated with the normal aging process.
Gait is a fundamental daily activity that requires the coordinated integration of the central and peripheral nervous systems, as well as the musculoskeletal system. Therefore, impairments in any of these systems-including the nervous, cardiovascular, respiratory, or musculoskeletal systems-can lead to gait dysfunction. Gait disorders negatively impact quality of life by increasing the risk of falls, reducing the ability to perform activities of daily living (ADLs), and limiting physical activity. Accordingly, various approaches to maintaining and improving gait function in older adults are being actively explored.
Currently, gait aids such as canes and walkers are commonly used to support individuals with gait impairments. These devices help redistribute body weight by providing a broader base of support, thereby assisting with balance and stability. However, they do not directly facilitate the movement of the lower limbs. To enhance gait function, numerous studies have investigated repetitive lower-limb movement training using bicycles or robotic devices. However, the extent of functional improvement resulting from such training remains unclear, and the long-term efficacy is still uncertain.
Recent advancements in sensing technology for joint motion and actuator efficiency have led to the development of wearable assistive devices that are significantly more compact and lightweight compared to conventional robotic systems. This study aims to evaluate the effectiveness of a newly developed electrically powered orthopedic exercise device in patients with gait disorders by assessing changes in gait parameters upon wearing the device, thereby exploring its clinical feasibility.
Detailed description
(1) Overview of study design This investigator-initiated exploratory study is a pilot study designed to evaluate the effectiveness and safety of the Electrically Powered Orthopedic Exercise Device by measuring and analyzing gait function and balance ability in patients with gait disorders under both non-wearing and wearing conditions.
(2) Experimental Group and Evaluation Procedures
- Participant Selection: This study includes a single test group with a total of 30 participants. The selection of participants for the electrically powered orthopedic exercise device and the overall study process will be conducted under the prescription and guidance of a rehabilitation medicine specialist, and supervised by assistants (physicians and occupational therapists). The examiner will collect clinical information and conduct a screening assessment for each participant.
- Evaluation Phase Without Device: After the screening test, participants undergo assessments of walking ability and balance without wearing the motorized orthopedic exercise device. A 10-minute rest period is provided between each assessment. If the participant wishes, additional rest time is allowed and recorded in the case report form. The assessments include the 10-Meter Walk Test, the 6-Minute Walk Test, the Timed Up and Go Test, and the Berg Balance Scale. These evaluations are conducted in the rehabilitation function testing room on the second floor of the facility under the supervision of the research team (physician and either a physical or occupational therapist).
- Pre-Adaptation Phase: After the evaluations without the device, a total of four adaptation sessions are conducted, during which the participant wears the device and performs short-distance walking within 10 meters. These sessions are designed to help the participant become familiar with the operation and wearing method of the H10 device. Appropriate device settings are configured for each participant to minimize any potential inexperience or anxiety during use. Participants must complete all four adaptation sessions, and each session should be conducted within a two-week interval.
- Evaluation Phase:
After completing all four adaptation sessions, participants undergo assessments of walking ability and balance while wearing the motorized orthopedic exercise device. A 10-minute rest period is provided between each assessment. If the participant wishes, additional rest time is allowed and recorded in the case report form. The assessments include the 10-Meter Walk Test, the 6-Minute Walk Test, the Timed Up and Go Test, and the Berg Balance Scale. These evaluations are conducted in the rehabilitation function testing room on the second floor of the facility under the supervision of the research team (physician and either a physical or occupational therapist). After the evaluations are completed, a usability and satisfaction survey regarding the motorized orthopedic exercise device is conducted.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Researchers will compare non-wearing and wearing conditions of the electrically powered orthopedic exercise device walking speeds, spatiotemporal parameters, balance, and satisfaction survey in participants and does not establish a control group.
| Arm | Type | Receives |
|---|---|---|
| Wearing conditions of Electrically Powered Orthopedic Exercise Device | Experimental | Device: Electrically Powered Orthopedic Exercise DeviceParticipants will undergo gait and balance function tests under both non-wearing and wearing conditions of the electrically powered orthopedic exercise device |
Who may qualify
- Ages
- 19 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (6 listed)
- Adults aged 19 years or older
- Patients experiencing subjective gait or balance disorders
- Individuals who visited Yongin Severance Hospital, understood the study, voluntarily agreed to participate, and signed the consent form
- Patients with a Functional Ambulatory Category (FAC) score of less than 4
- Individuals who can sit on the edge of a bed without assistance and stand for 10 seconds with or without support
Key exclusion criteria (9 listed)
- Individuals with contraindications to weight-bearing in the lower extremities, such as severe lower extremity joint contractures, osteoporosis, or untreated fractures
- Individuals who cannot wear the device due to skin diseases or open wounds
- Individuals with a significant discrepancy in lower extremity length
- Individuals with severe lower extremity deformities or joint contractures
- Individuals unable to maintain a sitting or standing posture independently
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Electrically Powered Orthopedic Exercise DeviceParticipants who pass the screening undergo an evaluation of gait function and balance ability without wearing the Electrically Powered Orthopedic Exercise Device. Afterward, the patient wears the motorized orthopedic exercise device for a total of four adaptation sessions. In each session, the patient performs short-distance walking within 10 meters while wearing the device to explore the appropriate assistive mode and level of support that match their physical condition. No evaluations are conducted while wearing the device during sessions 1, 2, and 3. After the 4th session, an evaluation identical to the one conducted without the device is performed while wearing it, and a satisfaction survey is conducted. | Device | Wearing conditions of Electrically Powered Orthopedic Exercise Device |
Primary outcome
10-Meter Walk Test
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Patients are instructed to walk 14 m, including 2 m at both ends for acceleration and deceleration, at their comfortable speed. Gait speed was calculated by dividing the 10m distance by the time taken.
9 secondary outcomes
Timed Up and Go (TUG) Test
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
6-Minute Walk Test
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Berg balance scale (BBS)
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Total Step Count
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Cadence
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Self-Selected Walking Speed
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Distance
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Spatiotemporal Parameters of Gait : Stride Length
Time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4
Satisfaction evaluation
Time frame: Upon completion of the end-point assessment conducted on the same day as session 4
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 29 Aug 2025.
- Background: PubMed 16696738Perera S, Mody SH, Woodman RC, Studenski SA. Meaningful change and responsiveness in common physical performance measures in older adults. J Am Geriatr Soc. 2006 May;54(5):743-9. doi: 10.1111/j.1532-5415.2006.00701.x.
- Background: PubMed 1991946Podsiadlo D, Richardson S. The timed "Up & Go": a test of basic functional mobility for frail elderly persons. J Am Geriatr Soc. 1991 Feb;39(2):142-8. doi: 10.1111/j.1532-5415.1991.tb01616.x.
- BackgroundLee, Sang-Heon, Bong-Keun Jung, and So-Yeon Park. "Korean Translation and Psychometric Properties of Quebec User Evaluation of Satisfaction Assistive Technology 2.0." Journal of the Korea Academia-Industrial Cooperation Society. The Korea Academia-Industrial Cooperation Society, July 31, 2013.
- Background: PubMed 27061162Bang DH, Shin WS. Effects of robot-assisted gait training on spatiotemporal gait parameters and balance in patients with chronic stroke: A randomized controlled pilot trial. NeuroRehabilitation. 2016 Apr 6;38(4):343-9. doi: 10.3233/NRE-161325.
- Background: PubMed 23023812Godi M, Franchignoni F, Caligari M, Giordano A, Turcato AM, Nardone A. Comparison of reliability, validity, and responsiveness of the mini-BESTest and Berg Balance Scale in patients with balance disorders. Phys Ther. 2013 Feb;93(2):158-67. doi: 10.2522/ptj.20120171. Epub 2012 Sep 27.
- Background: PubMed 3978515Guyatt GH, Sullivan MJ, Thompson PJ, Fallen EL, Pugsley SO, Taylor DW, Berman LB. The 6-minute walk: a new measure of exercise capacity in patients with chronic heart failure. Can Med Assoc J. 1985 Apr 15;132(8):919-23.
- Background: PubMed 11194105Dolny DG, Collins MG, Wilson T, Germann ML, Davis HP. Validity of lower extremity strength and power utilizing a new closed chain dynamometer. Med Sci Sports Exerc. 2001 Jan;33(1):171-5. doi: 10.1097/00005768-200101000-00026.
- BackgroundKim Heon-tae, Moon Jun-bae, Ryu Seung-ho, and Kang Min-soo. Validity study of the Korean version of the International Physical Activity Questionnaire (IPAQ): Verification of construct-related validity. Korean Journal of Physical Education No. 2017;56
- Background: PubMed 3685114Gajdosik RL, Bohannon RW. Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity. Phys Ther. 1987 Dec;67(12):1867-72. doi: 10.1093/ptj/67.12.1867.
- Background: PubMed 17908575Mehrholz J, Wagner K, Rutte K, Meissner D, Pohl M. Predictive validity and responsiveness of the functional ambulation category in hemiparetic patients after stroke. Arch Phys Med Rehabil. 2007 Oct;88(10):1314-9. doi: 10.1016/j.apmr.2007.06.764.
- Background: PubMed 17341308Cuthbert SC, Goodheart GJ Jr. On the reliability and validity of manual muscle testing: a literature review. Chiropr Osteopat. 2007 Mar 6;15:4. doi: 10.1186/1746-1340-15-4.
- BackgroundKang Y, NA D-L, Hahn S. A validity study on the Korean Mini-Mental State Examination (K-MMSE) in dementia patients. Journal of the Korean neurological association 1997:300-308
- Individual participant dataSharing planned: No
Related trials for Gait Disorders
Not yet recruiting
Holistic Healing for Knee Osteoarthritis
Knee Osteoarthritis (Knee OA)
Not yet recruiting
Video-based Visual Feedback Combined With Task-oriented Physiotherapy Among Cerebral Palsy
Cerebral Palsy (CP)
Recruiting
Effects of Virtual Reality Environments on Walking in Adults With and Without Knee Osteoarthritis
Knee Osteoarthritis
Recruiting
Effects of Custom 3D Printed Insoles and Short Foot Exercises in Pes Planus
Pes Planus
Active, not recruiting
Effects of Individualized Preferred and Higher Treadmill Walking Speeds Followed by Cognitive Training on Heart Rate Variability, Gait Performance, and Motor-Cognitive Function in Older Adults With Type 2 Diabetes: A Randomized Controlled Trial With 4-Week Retention Follow-up
Diabetes Mellitus, Type 2
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Na Young Kim, MD, PhD principal investigator
Severance Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A Phase 4 study testing Electrically Powered Orthopedic Exercise Device in people with Gait Disorders, run by Yonsei University at 1 site in South Korea.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 29 Aug 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Na Young Kim, MD, PhD (+82 010 9127 4482, kny8452@yuhs.ac), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
10-Meter Walk Test (time frame: A baseline assessment without wearing the device will be conducted on the same day as session 1, and an end-point assessment while wearing the device will be conducted on the same day as session 4). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07147543, which also lists 21 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Aug 2025.