Labor PainNCT07167498
Continuous Remote Vital Sign Monitoring During Labour Analgesia With Remifentanil
An observational study of Labor Pain, run by Nordsjaellands Hospital at 1 site in Denmark.
Trial summary
Continuous remote vital sign monitoring during labour analgesia with remifentanil - a prospective observational study Remifentanil PCA represents a well-tolerated, effective and valuable option for labour analgesia, yet its wider implementation is still limited by concerns of opioid side-effects particularly the risk… Read more about this study
- Who is it for?
- Ages 18 to 50 years, women onlyHealthy volunteers can take part
- Conditions the study is for
- Labor Pain
- What is being tested?
- Intermittent midwife absence during remote monitoring of remifentanil PCA in labour
- Type of treatment
- Lifestyle or therapy programme
- How many people
- 80 participants
- Where
- 1 siteDenmark
- Study dates
- 1 Nov 2026to 30 Jun 2028
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 50 years
- Women only
- Healthy volunteers accepted
- Adult
Study population: The study will be conducted at the labour ward of North Zealand Hospital. All parturients who meet the eligibility criteria may be included, provided that qualified staff are available at the time of admission.
Who may be able to join
- Minimum 18 years of age
- Able to provide written informed consent
- Giving birth to a singleton, cephalic presenting, expected healthy child, gestational age > 37 weeks.
- In active labour
Who cannot join
- Respiratory or cardiac disease
- BMI ≥ 40 Other opioids within the last 4 hours.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Laura Fugmann, Cand. Soc contact
Denmark1 site
University Hospital of Copenhagen, Northern Zealand
Hillerød, 3400
About this study
Official title: Continuous Remote Vital Sign Monitoring During Labour Analgesia With Remifentanil - a Prospective Observational Study
Continuous remote vital sign monitoring during labour analgesia with remifentanil - a prospective observational study
Remifentanil PCA represents a well-tolerated, effective and valuable option for labour analgesia, yet its wider implementation is still limited by concerns of opioid side-effects particularly the risk of respiratory depression leading to desaturation, potentially affecting the foetus. Thus, continuous one-to-one observation and monitoring in the delivery room, with the midwife unable to leave the patient unattended, is recommended. Such constant one-to-one monitoring may be challenging in present health-care settings where staffing constraints may limit the implementation of remifentanil as routine obstetric care.
Read more
Continuous remote vital sign monitoring to display oxygen saturation (SpO₂), respiratory rate, and heart rate on a handheld device (smartphone), has the potential to address this barrier by allowing the midwife to leave the labour room for short, predefined intervals while maintaining continuous surveillance of maternal vital signs. Such an approach could free staff resources without compromising patient safety. While centralised foetal monitoring (CTG) is standard practice in many units, the application of continuous remote vital sign monitoring for women receiving remifentanil during labour has, to our knowledge, never been formally studied.
Objectives The aim is to study whether remote monitoring during remifentanil patient-controlled analgesia (PCA) for labour affects the incidence of maternal desaturation and other safety outcomes (bradypnoea, bradycardia, and neonatal outcomes, assessed via Apgar scores and umbilical cord pH.) The study will be conducted in a setting where remifentanil PCA is administered for labour analgesia and the midwife is permitted to leave the labour room for intervals of up to 10 minutes while the woman is remotely monitored using a handheld device carried by the midwife. Predefined criteria for when the woman must be accompanied (e.g., if SpO₂ < 94%, supplemental oxygen >2L/min., or decreased consciousness). Outcomes in this group will be compared with a control group where the midwife remains continuously present in the labour room.
Read the detailed description
Introduction Remifentanil, a potent, ultra-short-acting opioid, administered intravenously via patient-controlled analgesia (PCA) has been used for more than a decade in several countries, particularly in Switzerland and at the Ulster Hospital in Ireland. In 2024, remifentanil was formally included as a standard option for labour analgesia in the United Kingdom and incorporated into the guidelines from the National Institute for Health and Care Excellence (NICE). The REMIPCA SAFE Network collaboration has further demonstrated that remifentanil PCA is a safe and effective method for labour analgesia, offering rapid onset, patient autonomy, and high maternal satisfaction (remiPCA.org).
In many European and Anglophone countries, nitrous oxide and epidural analgesia remain the most commonly used pharmacological methods for labour analgesia, while the use of remifentanil is not yet widespread in all settings. Nitrous oxide cause nausea and is under increasing scrutiny due to environmental concerns, while epidural analgesia, although highly effective for pain relief, is more invasive, resource intensive and associated with rare but severe complications.
Remifentanil PCA represents a well-tolerated, effective and valuable option for labour analgesia, yet its wider implementation is still limited by concerns of opioid side-effects particularly the risk of respiratory depression leading to desaturation, potentially affecting the foetus. Thus, continuous one-to-one observation and monitoring in the delivery room, with the midwife unable to leave the patient unattended, is recommended. Such constant one-to-one monitoring may be challenging in present health-care settings where staffing constraints may limit the implementation of remifentanil as routine obstetric care.
Continuous remote vital sign monitoring to display oxygen saturation (SpO₂), respiratory rate, and heart rate on a handheld device (smartphone), has the potential to address this barrier by allowing the midwife to leave the labour room for short, predefined intervals while maintaining continuous surveillance of maternal vital signs. Such an approach could free staff resources without compromising patient safety. While centralised foetal monitoring (CTG) is standard practice in many units, the application of continuous remote vital sign monitoring for women receiving remifentanil during labour has, to our knowledge, never been formally studied.
Objectives The aim is to study whether remote monitoring during remifentanil for labour analgesia affects the incidence of maternal desaturation and other safety outcomes (bradypnoea, bradycardia, and neonatal outcomes, assessed via Apgar scores and umbilical cord pH.) This will be assessed in a setup where remifentanil PCA for labour analgesia is given and the midwife is allowed maximum absence intervals of 10 minutes with predefined criteria for when the woman must be accompanied (e.g., if SpO₂ < 94%, supplemental oxygen >2L/min., or decreased consciousness) and compared with a control group where the midwife is in the labour room continuously.
Methods
Ethics The study will be conducted in compliance with the Declaration of Helsinki. Participation will be voluntary, and written informed consent will be obtained prior to inclusion. Participants may withdraw their consent at any time without consequences for their further treatment. Approval for data collection, processing, and storage will be sought from the Data Protection Authority for the Capital Region of Denmark prior to study initiation. The National committee on health research ethics, Denmark has approved the study in accordance with Danish legislation (ID: 2203648, date: 2024-06-25). All collected data will be handled in strict confidence and anonymised prior to analysis. The study protocol will be registered at ClinicalTrials.gov before inclusion of the first patient.
Study design A single centre before and after prospective observational study. Based on maternal and neonatal physiological parameters in parturients giving birth with remifentanil PCA for labour analgesia, using continuous remote vital sign monitoring, while the attending midwife is either continuously present in the labour room (group 1) or intermittently present, with absence intervals of up to 10 minutes (group 2)
Setting Location The study will be conducted at the labour ward of North Zealand Hospital. Recruitment period Recruitment is expected to be completed between 1 October 2025 and 31 December 2026.
Data collection Continuous monitoring of oxygen saturation (SpO₂), cardiotocography (CTG), respiratory rate, and heart rate during labour will be registered for analysis. Oxygen saturation (SpO₂), respiratory rate, and heart rate will be collected using the WARD technology (WARD247 Aps, Copenhagen, Denmark) and consists of threadless body-sensors which monitor oxygen saturation (SpO₂), ECG and respiratory rate every minute. These data are then electronically transferred to the WARD monitoring application on a handheld mobile device (smartphone). The adhesive body sensors are applied using a bracelet for the wrist and two ECG electrodes on the chest allowing considerable freedom of movement. CTG will be collected with Umbilical cord pH will be measured in all participants. Additional maternal and neonatal physiological parameters will be obtained from health records from the birth admission. The midwife will register when they are absent from the labour room, including frequency and duration of absences.
Remifentanil administration for labour analgesia Remifentanil is administered as patient-controlled analgesia (PCA) via an intravenous line. When the parturient presses the PCA button, a bolus of 20 µg remifentanil (corresponding to 1 mL) is delivered; the bolus dose may be adjusted between 10 µg and 30 µg. The lockout interval is 2 minutes. Administration must be discontinued around 10 minutes prior to delivery. The parturient is monitored for oxygen saturation (SpO₂), respiratory rate, cardiotocography (CTG), and heart rate. Each parturient will receive one-to-one midwifery care, as is standard practice in Denmark. The use of labour analgesia will be adapted to the individual course of labour, and medical pain management during active labour may include nitrous oxide, remifentanil, and epidural analgesia.
In the department's standard operating procedure, adapted from remipca.org, the target oxygen saturation (SpO₂) during the use of remifentanil is > 93%. If SpO₂ is < 94% for more than two minutes supplemental oxygen should be administered, either via face mask for short desaturation episodes or via nasal cannula.
When the parturients are receiving remifentanil for labour analgesia in the study protokol:
Group 1: The midwife stays in the labour room Group 2: the midwife is permitted to leave the labour room for intervals of up to 10 minutes while carrying a personal handheld device that displays continuous SpO₂, respiratory rate, and heart rate for remote monitoring. The monitoring system presents SpO₂, HR and RR continuously on the screen (updated every minute), and the midwife is responsible for continuous observation via the remote monitoring system and must respond immediately if SpO₂ falls below 94% or RR are below 10. As a safety precaution, an alarm is triggered after 10 minutes if SpO2 falls below 88%, after 5 minutes if SpO₂ falls below 85%, and immediately if SpO₂ falls below 80% and immediately if RR falls to ≤5 brpm.
The midwife is only permitted to leave the labour room if the parturient receiving remifentanil is awake, responsive, and accompanied by a partner who is capable and instructed to call for assistance if SpO₂ drops below 94% or if the parturient becomes unconscious. CTG will be centrally monitored at the ward level by the ward responsible midwife, who maintains an overview of CTG tracings from all delivery rooms.
As an extra safety precaution during this study, the ward-responsible midwife will also be informed if the attending midwife leaves the room and will be able to monitor the SpO₂ together with the CTG via the central monitoring system connected to all delivery rooms.
- Conditions
- Labor Pain
- Being tested
- Intermittent midwife absence during remote monitoring of remifentanil PCA in labour
- Keywords
- remifentanil, labour analgesia, remote monitoring, safety
- Medical subject headings
- Labor Pain
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Intermittent midwife absence during remote monitoring of remifentanil PCA in labourBehavioural
Midwife absence during remifentanil PCA for labour analgesia.
We aim to include a total of 80 participants. All will receive remifentanil PCA for labour analgesia and be monitored with remote monitoring equipment. First a group of 40 parturients will be included, and the attending midwife will not be allowed to leave the parturient (Group 1). A following group of 40 parturients will then be included and the attending midwife can leave the room in intervals up to 10 minutes (Group 2).
| Study group | Role | What they receive |
|---|---|---|
| Group 1: The midwife stays in the labour room during remifentanil PCA for labour analgesia | Group 1: The midwife stays in the labour room while the parturient are having remifentanil for labour analgesia. Receives: Behavioral: Intermittent midwife absence during remote monitoring of remifentanil PCA in labour | |
| Group 2: The midwife can leave the labour room during remifentanil PCA for labour analgesia | Group 2: the midwife is permitted to leave the labour room for intervals of up to 10 minutes while carrying a personal handheld device that displays continuous SpO₂, respiratory rate, and heart rate for remote monitoring. Receives: Behavioral: Intermittent midwife absence during remote monitoring of remifentanil PCA in labour |
What is being measured
The primary outcome is the main question the study is designed to answer.
Incidence of SpO₂ 90-93% lasting more than 2 minutes
During the use of remifentanil for labour analgesia.
Measured: During labour
Secondary outcomes (4)
Incidence of SpO2 89-85% lasting more than one minute
During the use of remifentanil for labour analgesia.
Measured: During labour
Any incidence of SpO2 < 85%
During the use of remifentanil for labour analgesia.
Measured: During labour
Incidence of RR < 9 for ≥5 minutes
During the use of remifentanil for labour analgesia.
Measured: During labour
Incidence of neonates with Apgar score < 7
During the use of remifentanil for labour analgesia.
Measured: measured 5 minutes after birth
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Sep 2025
- Study start1 Nov 2026 (estimated)
- Primary completion30 Dec 2027 (estimated)
- Study completion30 Jun 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Labor PainStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 80 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Nordsjaellands Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Patricia Duch, Nordsjaellands Hospital
- Investigators
- Patricia Duch, MD, Principal investigator, Nordsjaellands Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07167498
- Sponsor's protocol ID
- 104
- Status last verified
- Sep 2025
- First submitted
- 2 Sep 2025
- Last updated
- 8 Apr 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Continuous Remote Vital Sign Monitoring During Labour Analgesia With Remifentanil - a Prospective Observational Study
- ClinicalTrials.gov ID
- NCT07167498
- Acronym / sponsor ID
- 104
- Conditions
- Labor Pain
- Keywords
- remifentanil, labour analgesia, remote monitoring, safety
- Study type
- Observational
- Recruitment status
- Not yet recruiting
- Enrolment
- 80 participants (estimated)
- Lead sponsor
- Nordsjaellands HospitalUniversity, hospital or other
- Study start
- 1 Nov 2026 (estimated)
- Primary completion
- 30 Dec 2027 (estimated)
- Study completion
- 30 Jun 2028 (estimated)
- First posted
- 11 Sep 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Continuous remote vital sign monitoring during labour analgesia with remifentanil - a prospective observational study
Remifentanil PCA represents a well-tolerated, effective and valuable option for labour analgesia, yet its wider implementation is still limited by concerns of opioid side-effects particularly the risk of respiratory depression leading to desaturation, potentially affecting the foetus. Thus, continuous one-to-one observation and monitoring in the delivery room, with the midwife unable to leave the patient unattended, is recommended. Such constant one-to-one monitoring may be challenging in present health-care settings where staffing constraints may limit the implementation of remifentanil as routine obstetric care.
Continuous remote vital sign monitoring to display oxygen saturation (SpO₂), respiratory rate, and heart rate on a handheld device (smartphone), has the potential to address this barrier by allowing the midwife to leave the labour room for short, predefined intervals while maintaining continuous surveillance of maternal vital signs. Such an approach could free staff resources without compromising patient safety. While centralised foetal monitoring (CTG) is standard practice in many units, the application of continuous remote vital sign monitoring for women receiving remifentanil during labour has, to our knowledge, never been formally studied.
Objectives The aim is to study whether remote monitoring during remifentanil patient-controlled analgesia (PCA) for labour affects the incidence of maternal desaturation and other safety outcomes (bradypnoea, bradycardia, and neonatal outcomes, assessed via Apgar scores and umbilical cord pH.) The study will be conducted in a setting where remifentanil PCA is administered for labour analgesia and the midwife is permitted to leave the labour room for intervals of up to 10 minutes while the woman is remotely monitored using a handheld device carried by the midwife. Predefined criteria for when the woman must be accompanied (e.g., if SpO₂ < 94%, supplemental oxygen >2L/min., or decreased consciousness). Outcomes in this group will be compared with a control group where the midwife remains continuously present in the labour room.
Detailed description
Introduction Remifentanil, a potent, ultra-short-acting opioid, administered intravenously via patient-controlled analgesia (PCA) has been used for more than a decade in several countries, particularly in Switzerland and at the Ulster Hospital in Ireland. In 2024, remifentanil was formally included as a standard option for labour analgesia in the United Kingdom and incorporated into the guidelines from the National Institute for Health and Care Excellence (NICE). The REMIPCA SAFE Network collaboration has further demonstrated that remifentanil PCA is a safe and effective method for labour analgesia, offering rapid onset, patient autonomy, and high maternal satisfaction (remiPCA.org).
In many European and Anglophone countries, nitrous oxide and epidural analgesia remain the most commonly used pharmacological methods for labour analgesia, while the use of remifentanil is not yet widespread in all settings. Nitrous oxide cause nausea and is under increasing scrutiny due to environmental concerns, while epidural analgesia, although highly effective for pain relief, is more invasive, resource intensive and associated with rare but severe complications.
Remifentanil PCA represents a well-tolerated, effective and valuable option for labour analgesia, yet its wider implementation is still limited by concerns of opioid side-effects particularly the risk of respiratory depression leading to desaturation, potentially affecting the foetus. Thus, continuous one-to-one observation and monitoring in the delivery room, with the midwife unable to leave the patient unattended, is recommended. Such constant one-to-one monitoring may be challenging in present health-care settings where staffing constraints may limit the implementation of remifentanil as routine obstetric care.
Continuous remote vital sign monitoring to display oxygen saturation (SpO₂), respiratory rate, and heart rate on a handheld device (smartphone), has the potential to address this barrier by allowing the midwife to leave the labour room for short, predefined intervals while maintaining continuous surveillance of maternal vital signs. Such an approach could free staff resources without compromising patient safety. While centralised foetal monitoring (CTG) is standard practice in many units, the application of continuous remote vital sign monitoring for women receiving remifentanil during labour has, to our knowledge, never been formally studied.
Objectives The aim is to study whether remote monitoring during remifentanil for labour analgesia affects the incidence of maternal desaturation and other safety outcomes (bradypnoea, bradycardia, and neonatal outcomes, assessed via Apgar scores and umbilical cord pH.) This will be assessed in a setup where remifentanil PCA for labour analgesia is given and the midwife is allowed maximum absence intervals of 10 minutes with predefined criteria for when the woman must be accompanied (e.g., if SpO₂ < 94%, supplemental oxygen >2L/min., or decreased consciousness) and compared with a control group where the midwife is in the labour room continuously.
Methods
Ethics The study will be conducted in compliance with the Declaration of Helsinki. Participation will be voluntary, and written informed consent will be obtained prior to inclusion. Participants may withdraw their consent at any time without consequences for their further treatment. Approval for data collection, processing, and storage will be sought from the Data Protection Authority for the Capital Region of Denmark prior to study initiation. The National committee on health research ethics, Denmark has approved the study in accordance with Danish legislation (ID: 2203648, date: 2024-06-25). All collected data will be handled in strict confidence and anonymised prior to analysis. The study protocol will be registered at ClinicalTrials.gov before inclusion of the first patient.
Study design A single centre before and after prospective observational study. Based on maternal and neonatal physiological parameters in parturients giving birth with remifentanil PCA for labour analgesia, using continuous remote vital sign monitoring, while the attending midwife is either continuously present in the labour room (group 1) or intermittently present, with absence intervals of up to 10 minutes (group 2)
Setting Location The study will be conducted at the labour ward of North Zealand Hospital. Recruitment period Recruitment is expected to be completed between 1 October 2025 and 31 December 2026.
Data collection Continuous monitoring of oxygen saturation (SpO₂), cardiotocography (CTG), respiratory rate, and heart rate during labour will be registered for analysis. Oxygen saturation (SpO₂), respiratory rate, and heart rate will be collected using the WARD technology (WARD247 Aps, Copenhagen, Denmark) and consists of threadless body-sensors which monitor oxygen saturation (SpO₂), ECG and respiratory rate every minute. These data are then electronically transferred to the WARD monitoring application on a handheld mobile device (smartphone). The adhesive body sensors are applied using a bracelet for the wrist and two ECG electrodes on the chest allowing considerable freedom of movement. CTG will be collected with Umbilical cord pH will be measured in all participants. Additional maternal and neonatal physiological parameters will be obtained from health records from the birth admission. The midwife will register when they are absent from the labour room, including frequency and duration of absences.
Remifentanil administration for labour analgesia Remifentanil is administered as patient-controlled analgesia (PCA) via an intravenous line. When the parturient presses the PCA button, a bolus of 20 µg remifentanil (corresponding to 1 mL) is delivered; the bolus dose may be adjusted between 10 µg and 30 µg. The lockout interval is 2 minutes. Administration must be discontinued around 10 minutes prior to delivery. The parturient is monitored for oxygen saturation (SpO₂), respiratory rate, cardiotocography (CTG), and heart rate. Each parturient will receive one-to-one midwifery care, as is standard practice in Denmark. The use of labour analgesia will be adapted to the individual course of labour, and medical pain management during active labour may include nitrous oxide, remifentanil, and epidural analgesia.
In the department's standard operating procedure, adapted from remipca.org, the target oxygen saturation (SpO₂) during the use of remifentanil is > 93%. If SpO₂ is < 94% for more than two minutes supplemental oxygen should be administered, either via face mask for short desaturation episodes or via nasal cannula.
When the parturients are receiving remifentanil for labour analgesia in the study protokol:
Group 1: The midwife stays in the labour room Group 2: the midwife is permitted to leave the labour room for intervals of up to 10 minutes while carrying a personal handheld device that displays continuous SpO₂, respiratory rate, and heart rate for remote monitoring. The monitoring system presents SpO₂, HR and RR continuously on the screen (updated every minute), and the midwife is responsible for continuous observation via the remote monitoring system and must respond immediately if SpO₂ falls below 94% or RR are below 10. As a safety precaution, an alarm is triggered after 10 minutes if SpO2 falls below 88%, after 5 minutes if SpO₂ falls below 85%, and immediately if SpO₂ falls below 80% and immediately if RR falls to ≤5 brpm.
The midwife is only permitted to leave the labour room if the parturient receiving remifentanil is awake, responsive, and accompanied by a partner who is capable and instructed to call for assistance if SpO₂ drops below 94% or if the parturient becomes unconscious. CTG will be centrally monitored at the ward level by the ward responsible midwife, who maintains an overview of CTG tracings from all delivery rooms.
As an extra safety precaution during this study, the ward-responsible midwife will also be informed if the attending midwife leaves the room and will be able to monitor the SpO₂ together with the CTG via the central monitoring system connected to all delivery rooms.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Group 1: The midwife stays in the labour room during remifentanil PCA for labour analgesia | – | Behavioral: Intermittent midwife absence during remote monitoring of remifentanil PCA in labourGroup 1: The midwife stays in the labour room while the parturient are having remifentanil for labour analgesia. |
| Group 2: The midwife can leave the labour room during remifentanil PCA for labour analgesia | – | Behavioral: Intermittent midwife absence during remote monitoring of remifentanil PCA in labourGroup 2: the midwife is permitted to leave the labour room for intervals of up to 10 minutes while carrying a personal handheld device that displays continuous SpO₂, respiratory rate, and heart rate for remote monitoring. |
Who may qualify
- Ages
- 18 to 50 years
- Sex
- Female only
- Healthy volunteers
- Accepted
- Age groups
- Adult
- Study population
- The study will be conducted at the labour ward of North Zealand Hospital. All parturients who meet the eligibility criteria may be included, provided that qualified staff are available at the time of admission.
Key inclusion criteria (4 listed)
- Minimum 18 years of age
- Able to provide written informed consent
- Giving birth to a singleton, cephalic presenting, expected healthy child, gestational age > 37 weeks.
- In active labour
Key exclusion criteria (2 listed)
- Respiratory or cardiac disease
- BMI ≥ 40 Other opioids within the last 4 hours.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Intermittent midwife absence during remote monitoring of remifentanil PCA in labourMidwife absence during remifentanil PCA for labour analgesia. We aim to include a total of 80 participants. All will receive remifentanil PCA for labour analgesia and be monitored with remote monitoring equipment. First a group of 40 parturients will be included, and the attending midwife will not be allowed to leave the parturient (Group 1). A following group of 40 parturients will then be included and the attending midwife can leave the room in intervals up to 10 minutes (Group 2). | Behavioural | Group 1: The midwife stays in the labour room during remifentanil PCA for labour analgesia, Group 2: The midwife can leave the labour room during remifentanil PCA for labour analgesia |
Primary outcome
Incidence of SpO₂ 90-93% lasting more than 2 minutes
Time frame: During labour
During the use of remifentanil for labour analgesia.
4 secondary outcomes
Incidence of SpO2 89-85% lasting more than one minute
Time frame: During labour
Any incidence of SpO2 < 85%
Time frame: During labour
Incidence of RR < 9 for ≥5 minutes
Time frame: During labour
Incidence of neonates with Apgar score < 7
Time frame: measured 5 minutes after birth
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Apr 2026.
- Individual participant dataSharing planned: No
Related trials for Labor Pain
RecruitingPhase 4
Analgesic Efficacy and Obstetric Effects of Tramadol, Paracetamol and Placebo in Active Labor
Labor Pain
Recruiting
The Effect Of Partner-Assısted Rebozo Technıque On Labor Paın And Satısfactıon In Prımary Pregnant Women
Labor Pains
Recruiting
Pain Neuroscience-Based Education for Labor Pain in Pregnant Women
Labor Pain and Anxiety
Not yet recruiting
The 90% Effective Initial Volume for Labor Analgesia Under Double Dural Puncture Epidural Technique
Labor Pain
Not yet recruiting
Initiation Ropivacaine Dose for Labor Analgesia Via Double Dural Puncture Epidural Technique
Labor Pain
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Laura Fugmann, Cand. Soc contact
Patricia Duch, MD principal investigator
Nordsjaellands Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Labor Pain, run by Nordsjaellands Hospital at 1 site in Denmark.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 8 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Patricia Duch, MD (+45 48292504, Patricia.duch@regionh.dk), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Incidence of SpO₂ 90-93% lasting more than 2 minutes (time frame: During labour). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Apr 2026; AzTrials last refreshed its copy on 8 Nov 2026.