AzTrials
AzTrials

MicroemboliMESOMEGANCT07172165

A Multicenter Study to Optimize Microembolic Signal Classification Based on Double--Blind Multiparametric Assessment by Human Experts Using an Universal Graphical Interface [MESOMEGA]

An observational study of Microemboli and Stroke, run by Universidade do Porto at 1 site in Portugal.

Enrolling by invitation

Enrolling by invitation. The study team selects and invites participants, usually from an existing group of patients.

Sites and contacts
Official record
Search all trials

Trial summary

Microembolic signals (MES) is a powerful predictor of future embolic events. This study aims to develop and validate a accurate model of classification of MES obtained by transcranial Doppler. monitoring of However, MES detection is technically demanding and requires expert interpretation. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Expert double-blind evaluation
How many people
850 participants
Where
1 sitePortugal
Study dates
15 May 2025to 15 Mar 2026
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Clips of Transcranial Doppler monitoring either MES or non-MES high intensity transient signals (e.g. artifacts, speckle).

Who may be able to join

  • MES of presumed solid form or non-MES high intensity transient signals
  • Obtained from on a human subject with age equal to or more than 18years old
  • Obtained from proximal middle cerebral artery (M1 segment)
  • Clip with 20 seconds duration with clearly event of interest marked using TCDPlayer
  • With an overall background spectrum of reasonable quality to be analyzed

Who cannot join

  • MES in gaseous form
  • Use of ultrasound contrast agent or agitated saline in the previous 24 hours
  • Obtained from patients with mechanical valve
  • Obtained from patient during any cardiac surgery or endovascular procedure1
  • Obtained from patient with recent severe trauma
  • Clips with multiples inseparable MES (e.g. curtain)

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Portugal1 site
  • Faculty of Medicine University Porto

    Porto, 4200-319

Other trials in Portugal

About this study

Microembolic signals (MES) is a powerful predictor of future embolic events. This study aims to develop and validate a accurate model of classification of MES obtained by transcranial Doppler. monitoring of However, MES detection is technically demanding and requires expert interpretation. By providing a reproducible framework for MES interpretation, this work aims to facilitate MES integration into future clinical trials and decision-making.

Read the detailed description

Rationale

The presence of microembolic signals (MES) is a powerful predictor of future embolic events. However, MES detection is technically demanding and requires expert interpretation.

Aim We aim to develop and validate a supervised prediction model for MES classification using features extracted from transcranial Doppler (TCD) signals. The model is intended to support expert consensus and enhance classification concordance by utilizing standardized, pre-specified signal features.

Sample size estimates Sample size was estimated using the pmsampsize R package. Based on five predictors, a 1:1 proportion of MES in final dataset, a maximum Nagelkerke R² of 0.75, a shrinkage factor of 90% (to minimize overfitting), and a mean absolute error in predicted probabilities ≤ 0.05, the required sample size is 850 clips. The calculations included an 80:20 training/testing split and a 10% dropout rate.

Methods and Design The "Multicenter Study to Optimize Microembolic Signal Classification Based on Double-blind Multiparametric Assessment by Human Experts Using a Universal Graphical Interface" (MESOMEGA trial) is a prospective, randomized, double-blind, diagnostic validation study. All members of World Organization of Neurosonology, their national affiliated societies, and worldwide TCD users in the medical community will be invited to submit TCD monitoring 20-second clips of presumed solid MES or non-MES high-intensity transient signals recorded using a 2 MHz transducer from the proximal middle cerebral artery. Exclusion criteria include inseparable multiple MES (e.g., curtain) or any gaseous embolic form. Each clip will be independently assessed by two randomly allocated experts. Expert reading will be using TCDPlayer and will be blinded to clinical data, source information, and other assessments. They will manually annotate six predefined signal features: characteristic audible signal increase, characteristic wave-like of raw Doppler signals, Emboli-to-Background Ratio, Emboli-to-Mirror Ratio, signal duration, and average velocity of maximum intensity. Analysis will be completed within 90 days. A supervised decision tree model will be developed on the training dataset and validation set. Performance will be assessed using stratified k-fold cross-validation, reporting accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). Following model development, a Delphi consensus process will be used to evaluate and validate model outputs, aiming for expert agreement on model acceptability and readiness for clinical application. The study will be conducted under appropriate ethical approval and in accordance with international report standards. The study will be conducted under ethical guidelines and approval.

Study Outcomes The primary outcome is the classification of clips as MES or non-MES, using expert consensus as ground truth. The model will aim for ≥ 90% classification accuracy. Secondary outcomes include model performance without auditory parameter, interrater concordance and variability, and Delphi consensus strength.

Discussion This study will assess the performance of a supervised decision tree model for MES classification and benchmark it against prior MES detection approaches. By providing a reproducible framework for MES interpretation, this work aims to facilitate MES integration into future clinical trials and decision-making.

Being tested
Expert double-blind evaluation
Keywords
microembolic signals (MES), decision tree, stroke, microemboli, transcranial Doppler, diagnostic standard, prediction model
Medical subject headings
Stroke

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Expert double-blind evaluationDiagnostic test

    Expert reading will be using TCDPlayer and will be blinded to clinical data, source information, and other assessments. They will manually annotate six predefined signal features: characteristic audible signal increase, characteristic wave-like of raw Doppler signals, Emboli-to-Background Ratio, Emboli-to-Mirror Ratio, signal duration, and average velocity of maximum intensity. Analysis will be completed within 90 days.

Study groups in NCT07172165
Study groupRoleWhat they receive
Transcranial Doppler clips databaseClips of MES and non-MES events. Each clip will be 20 seconds (-10 and +10 seconds in reference to the marked event). The data presented will not be modified from its original form. The final database that will be used for expert evaluation will include the necessary clips and proportions to ensure maximum reproducibility and generalization of the data. Clips will be obtained from at least 3 different types or brands of TCD machines. A single machine cannot be the source of more than 50% of the final data set. MES will be from a variety of sources including patients with atherosclerotic disease, cardioembolic stroke, or embolic stroke of unknown source.
Receives: Diagnostic Test: Expert double-blind evaluation

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Classification of each signal as MES or Non-MES

    A MES or non-MES will be considered as such the two experts agree. If the two experts do not agree, a special board (RA, WM) will decide on classification. "Recordings that remain undetermined, or those classified as undetermined by both experts, will be excluded from the primary analysis of this study. All experts will be blinded to each other, any identification tag or clinical information. We will include five predictors in the primary analysis which are: the presence of characteristic audible signal increase, characteristic wave-like raw Doppler signals, the Emboli-to-Background Ratio (EBR), Emboli-to-mirror-ratio (EMR), time length and average velocity of maximum intensity. The calculation and definition of each predictor is detailed in table 3 and in supplemental information (Proposal for a systematic analysis and reporting of microembolic signal detection of the Microembolic Signal Detection Working Groups of the World Organization of Neurosonology).

    Measured: From enrollment until December of 2026

Secondary outcomes (4)
  1. Trimmed version of the model

    To compare the model performance with and without auditory parameter To compare the subgroups of exclude MES vs non-MES how model performance

    Measured: From enrollment until December of 2026

  2. Model with extra-features

    To compare the model performance with and without a derived Embolus Distance parameter as calculated by the formula: Embolus Distance (mm) = Time length x average velocity of maximum intensity

    Measured: From enrollment until December of 2026

  3. Inter-expert variability in feature extraction.

    Measured: From enrollment until December of 2026

  4. Delphi process

    Strength of the Delphi process

    Measured: From enrollment until December of 2026

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted15 Sep 2025
  2. Study start15 May 2025
  3. Primary completion15 Dec 2025 (estimated)
  4. Study completion15 Mar 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
850 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07172165
Sponsor's protocol ID
MESOMEGA
Acronym
MESOMEGA
Status last verified
May 2025
First submitted
27 Jun 2025
Last updated
10 Dec 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: Publication of protocol and associate report sheets

Publications

  • Collins GS, Moons KGM, Dhiman P, Riley RD, Beam AL, Van Calster B, Ghassemi M, Liu X, Reitsma JB, van Smeden M, Boulesteix AL, Camaradou JC, Celi LA, Denaxas S, Denniston AK, Glocker B, Golub RM, Harvey H, Heinze G, Hoffman MM, Kengne AP, Lam E, Lee N, Loder EW, Maier-Hein L, Mateen BA, McCradden MD, Oakden-Rayner L, Ordish J, Parnell R, Rose S, Singh K, Wynants L, Logullo P. TRIPOD+AI statement: updated guidance for reporting clinical prediction models that use regression or machine learning methods. BMJ. 2024 Apr 16;385:e078378. doi: 10.1136/bmj-2023-078378.

    PubMed 38626948
  • Riley RD, Ensor J, Snell KIE, Harrell FE Jr, Martin GP, Reitsma JB, Moons KGM, Collins G, van Smeden M. Calculating the sample size required for developing a clinical prediction model. BMJ. 2020 Mar 18;368:m441. doi: 10.1136/bmj.m441. No abstract available.

    PubMed 32188600
  • Wong KS, Chen C, Fu J, Chang HM, Suwanwela NC, Huang YN, Han Z, Tan KS, Ratanakorn D, Chollate P, Zhao Y, Koh A, Hao Q, Markus HS; CLAIR study investigators. Clopidogrel plus aspirin versus aspirin alone for reducing embolisation in patients with acute symptomatic cerebral or carotid artery stenosis (CLAIR study): a randomised, open-label, blinded-endpoint trial. Lancet Neurol. 2010 May;9(5):489-97. doi: 10.1016/S1474-4422(10)70060-0. Epub 2010 Mar 22.

    PubMed 20335070
  • Markus HS, Droste DW, Kaps M, Larrue V, Lees KR, Siebler M, Ringelstein EB. Dual antiplatelet therapy with clopidogrel and aspirin in symptomatic carotid stenosis evaluated using doppler embolic signal detection: the Clopidogrel and Aspirin for Reduction of Emboli in Symptomatic Carotid Stenosis (CARESS) trial. Circulation. 2005 May 3;111(17):2233-40. doi: 10.1161/01.CIR.0000163561.90680.1C. Epub 2005 Apr 25.

    PubMed 15851601
  • Castro P, Ferreira J, Malojcic B, Bazadona D, Baracchini C, Pieroni A, Skoloudik D, Azevedo E, Kaps M. Detection of microemboli in patients with acute ischaemic stroke and atrial fibrillation suggests poor functional outcome. Eur Stroke J. 2024 Jun;9(2):409-417. doi: 10.1177/23969873231220508. Epub 2023 Dec 27.

    PubMed 38149620
  • Das AS, Regenhardt RW, LaRose S, Monk AD, Castro PM, Sheriff FG, Sorond FA, Vaitkevicius H. Microembolic Signals Detected by Transcranial Doppler Predict Future Stroke and Poor Outcomes. J Neuroimaging. 2020 Nov;30(6):882-889. doi: 10.1111/jon.12749. Epub 2020 Jul 10.

    PubMed 32648610
  • Sheriff F, Diz-Lopes M, Khawaja A, Sorond F, Tan CO, Azevedo E, Franceschini MA, Vaitkevicius H, Li K, Monk AD, Michaud SL, Feske SK, Castro P. Microemboli After Successful Thrombectomy Do Not Affect Outcome but Predict New Embolic Events. Stroke. 2020 Jan;51(1):154-161. doi: 10.1161/STROKEAHA.119.025856. Epub 2019 Dec 4.

    PubMed 31795906
  • Padayachee TS, Parsons S, Theobold R, Linley J, Gosling RG, Deverall PB. The detection of microemboli in the middle cerebral artery during cardiopulmonary bypass: a transcranial Doppler ultrasound investigation using membrane and bubble oxygenators. Ann Thorac Surg. 1987 Sep;44(3):298-302. doi: 10.1016/s0003-4975(10)62077-2.

    PubMed 2957966
  • Farina F, Palmieri A, Favaretto S, Viaro F, Cester G, Causin F, Baracchini C. Prognostic Role of Microembolic Signals After Endovascular Treatment in Anterior Circulation Ischemic Stroke Patients. World Neurosurg. 2018 Feb;110:e882-e889. doi: 10.1016/j.wneu.2017.11.120. Epub 2017 Nov 28.

    PubMed 29191539
  • Spencer MP, Thomas GI, Nicholls SC, Sauvage LR. Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography. Stroke. 1990 Mar;21(3):415-23. doi: 10.1161/01.str.21.3.415.

    PubMed 2408197

Questions about this trial

What is this clinical trial studying?

An observational study of Microemboli and Stroke, run by Universidade do Porto at 1 site in Portugal.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: enrolling by invitation, as of the sponsor's last update on 10 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Portugal. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Classification of each signal as MES or Non-MES (time frame: From enrollment until December of 2026). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07172165, which also lists 10 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Dec 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in