AzTrials
AzTrials

Respiratory FailureINFLATE-ICUNCT07188038

The Impact of Low Versus High Positive End-expiratory Pressure on Diaphragm Function, Ventilation Efficiency, and Lung Mechanics

A study testing Low positive end-expiratory pressure, Medium positive end-expiratory pressure and High positive end-expiratory pressure in people with Respiratory Failure and ARDS (Acute Respiratory Distress Syndrome), run by Vastra Gotaland Region at 2 sites in Sweden.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record

Search all trials

Trial summary

The goal of this interventional study is to evaluate the effect of different positive end-expiratory pressures (PEEP) on lung and diaphragm function in patients mechanically ventilated with pressure support ventilation in the intensive care unit. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Low positive end-expiratory pressure, Medium positive end-expiratory pressure and High positive end-expiratory pressure
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
2 sitesSweden
Study dates
31 Aug 2026to 31 Dec 2027
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Mechanical ventilation with pressure support or mechanical ventilation with possibility to transition to pressure support
  • Oxygen requirement ≤ 50%
  • Pressure support ≤ 12 cmH2O
  • PEEP ≤ 12 cmH2O
  • Age ≥ 18 years
  • Adequate intravascular volume status

Who cannot join

  • Circulatory instability
  • Brain death diagnosis/brain death evaluation
  • Norepinephrine dose > 0.4 µg/kg/min
  • Muscle relaxation administered within 2 hours
  • Pregnancy
  • Contraindication to esophageal catheterization (e.g., esophageal varices)
Show all 17Show fewer
  • Conditions with increased risk of pneumothorax (such as severe COPD (Chronic Obstructive Pulmonary Disease) or extensive emphysema)
  • Untreated pneumothorax
  • Symptomatic airway obstruction
  • Discontinuation criteria during ongoing study intervention:
  • Heart rate > 120 beats/min
  • Systolic blood pressure > 180 mmHg
  • Inspired oxygen fraction > 70%
  • Respiratory rate > 35/min
  • RASS (Richmond Agitation Sedation Scale) ≥ 2
  • Doubling of norepinephrine dose or increase of norepinephrine dose to > 0.5 µg/kg/min to maintain mean arterial pressure
  • Bradycardia < 45 beats/min

Trial locations and contacts

2 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Per Persson contact

per.persson@gregion.se

Sweden2 sites, 2 recruiting
  • Central intensivvårdsavdelning, Sahlgrenska University Hospital

    Gothenburg, Västra Götaland County, 413 45

    Hannes Widing, 0046703957374, hannes.widing@vgregion.se

    Hannes Widing

    Recruiting
  • Thorax intensivvårdsavdelning, Område 6, Sahlgrenska University Hospital, Västra Götalandsregionen

    Gothenburg, Västra Götaland County, 413 45

    Viktor Erbring, 0046706456664, viktor.erbring@vgregion.se

    Not yet recruiting

Other trials in Sweden

About this study

Official title: The Impact of Low Versus High Positive End-Expiratory Pressure on Diaphragm Function, Ventilation Efficiency, and Lung Mechanics During Pressure Support Ventilation: A Randomized Interventional Crossover Study

The goal of this interventional study is to evaluate the effect of different positive end-expiratory pressures (PEEP) on lung and diaphragm function in patients mechanically ventilated with pressure support ventilation in the intensive care unit. The main questions aim to answer:

Does higher PEEP level affect diaphragm contractions and ventilatory efficiency? Does higher PEEP level limit inspiratory efforts? Does higher PEEP level affect lung compliance?

Read more

The participants will be subjected to three different PEEP levels during pressure support ventilation:

Low PEEP (4 cmH2O), Medium PEEP (10 cmH2O), High PEEP (16 cmH2O).

The lung and diaphragm function will be evaluated using high-resolution esophageal manometry, electrical activity of the diaphragm, external diaphragm ultrasound and spirometric ventilator data.

Being tested
Low positive end-expiratory pressure, Medium positive end-expiratory pressure, High positive end-expiratory pressure
Keywords
Positive end-expiratory pressure, PEEP, pressure support ventilation, assisted breathing, Inspiratory effort, Inspiratory drive, Ventilation efficiency, Diaphragm
Medical subject headings
Respiratory Insufficiency, Acute Lung Injury, Pneumonia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Low positive end-expiratory pressureProcedure or surgery

    Low (4 cmH2O) positive end-expiratory pressure (PEEP) will be applied during pressure support ventilation. The PEEP level will be kept for 10 minutes prior to data acquisition.

  • Medium positive end-expiratory pressureProcedure or surgery

    Medium (10 cmH2O) positive end-expiratory pressure (PEEP) will be applied during pressure support ventilation. The PEEP level will be kept for 10 minutes prior to data acquisition.

  • High positive end-expiratory pressureProcedure or surgery

    High(16 cmH2O) positive end-expiratory pressure (PEEP) will be applied during pressure support ventilation. The PEEP level will be kept for 10 minutes prior to data acquisition.

Study groups in NCT07188038
Study groupRoleWhat they receive
Low PEEPExperimentalLow positive end-expiratory pressure (4 cmH2O)
Receives: Procedure: Low positive end-expiratory pressure
Medium PEEPExperimentalMedium positive end-expiratory pressure (10 cmH2O)
Receives: Procedure: Medium positive end-expiratory pressure
High PEEPExperimentalHigh positive end-expiratory pressure (16 cmH2O)
Receives: Procedure: High positive end-expiratory pressure

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Inspiratory effort

    Inspiratory effort will be measured by the tidal change in esophageal pressure (in cmH2O) during assisted breathing. The esophageal pressure will be measured using a high-resolution manometry catheter. The change from expiratory to inspiratory esophageal pressure will represent the tidal change and be used to estimate the inspiratory effort.

    Measured: Measured during 5 uninterrupted breaths 10 minutes after application of interventional PEEP level

  2. Inspiratory drive

    The electric activity of the diaphragm (Eadi) will be measured using a NAVA (neurally adjusted ventilatory assist) catheter. The change from end-expiratory to inspiratory Eadi will be calculated. This represents the inspiratory drive. The Eadi will be measured in Voltage.

    Measured: Measured during 5 uninterrupted breaths 10 minutes after application of interventional PEEP level

  3. Effort-to-drive ratio

    The effort-to-drive ratio (EDR) will be calculated as the inspiratory effort (tidal change in esophageal pressure) divided by the inspiratory drive (tidal change in electric activity of the diaphragm).

    Measured: Calculated from the measures collected 10 minutes after application of interventional PEEP level

  4. Neuromechanical efficiency

    The neuromechanical efficiency will be calculated as the change in airway pressure during an occlusion test (Pocc) (measured from end-expiration to maximum negative pressure during the occlusion manoeuvre) divided by the inspiratory change in electric activity of the diaphragm (from end-expiration to inspiration).

    Measured: Calculated from the measures collected during the occlusion manoeuvre performed 10-15 minutes after application of interventional PEEP level

  5. Thickening fraction of the diaphragm (TFdi)

    Measured by ultrasound at the right hemidiaphragm. The thickening fraction of the diaphragm (TFdi) will be calculated as [ (end-inspiratory diaphragm thickness - end-expiratory diaphragm thickness) / end-expiratory diaphragm thickness) ].

    Measured: Measured 10 minutes after application of interventional PEEP level

  6. Transpulmonary driving pressure

    Change in transpulmonary pressure ( airway pressure - esophageal pressure) from end-expiration to end-inspiration will be calculated using ventilator data and high-resolution manometry

    Measured: Measured during 5 breaths 10 minutes after application of interventional PEEP level

  7. Occlusion pressure

    The airway pressure drop from end-expiration to minimum pressure during an occlusion manoeuvre will be measured using the ventilator. The pressure drop indicates the inspiratory effort. It will be measured in cmH2O.

    Measured: The occlusion pressure will be measured during an occlusion manoeuvre performed 10-15 minutes after application of interventional PEEP level.

Secondary outcomes (5)
  1. Airway driving pressure

    Difference in airway pressure between end-expiration and during an inspiratory hold will be calculated from the ventilator data.

    Measured: Measured during an inspiratory hold performed 10-15 minutes after application of interventional PEEP level

  2. Lung compliance

    Lung compliance will be calculated as the tidal volume divided by the change in transpulmonary pressure from end-expiration to end-inspiration.

    Measured: Measured during an inspiratory hold performed 10 - 15 minutes after application of interventional PEEP level

  3. Thickening fraction of the expiratory abdominal muscles (TFabd)

    The abdominal muscles will be visualized by ultrasound in the anterior axillary line, midway between the inferior border of the ribcage and the iliac crest. The thickening fraction will be calculated as [(expiratory thickness - end-inspiratory thickness) / end-inspiratory thickness ].

    Measured: Measured 10 minutes after application of interventional PEEP level

  4. Oxygenation

    The PFI (PaO2/FiO2 ratio) will be calculated as arterial PaO2 (partial pressure of oxygen) divided by the FiO2 (fraction of inspired oxygen)

    Measured: The blood gas will be collected 10 minutes after application of interventional PEEP level

  5. Respiratory system compliance

    The respiratory system compliance will be calculated as the tidal volume divided by the airway driving pressure during an inspiratory hold.

    Measured: Measured during an inspiratory hold manoeuvre performed 10-15 minutes after the application of interventional PEEP level.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Sep 2025
  2. Study start31 Aug 2026
  3. Primary completion31 Jul 2027 (estimated)
  4. Study completion31 Dec 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Supportive care
Allocation
Randomised
Intervention model
Crossover
Model description
Randomized interventional crossover study
Masking
Single blind
Who is masked
Participant
Enrolment
25 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07188038
Sponsor's protocol ID
2025-01286-01
Other IDs
2025
Acronym
INFLATE-ICU
Status last verified
Sep 2026
First submitted
1 Sep 2025
Last updated
2 Sep 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: The acquired swedish ethical permit does not allow for the sharing of data to international researcher without a confidentiality review or the application of a new ethical permit

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in