AzTrials
AzTrials

Device ReplacementNCT07197411

A Comparative Study of Portable Patch-type Carotid Ultrasound CADFlow and Desktop Ultrasound Machines

An observational study of Device Replacement, run by Xuzhou Medical University Affiliated Suqian Hospital at 1 site in China.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

observational study The purpose of this observational study is to clarify the consistency, accuracy, and reproducibility of portable patch carotid ultrasound (CADFlow) compared to desktop ultrasound machines in detecting cardiac output (CO), peak velocity (Vmax), and minimum velocity (Vmin) in healthy volunteers. Read more about this study

Who is it for?
Ages 18 to 79 yearsHealthy volunteers can take part
Conditions the study is for
Device Replacement
What is being tested?
Evaluating the Consistency and Accuracy of Two Devices in Monitoring Hemodynamic Parameters and Hemodynamic monitoring
Type of treatment
Medical device
How many people
140 participants
Where
1 siteChina
Study dates
1 Oct 2025to 31 Dec 2025
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 79 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: Include healthy individuals aged 18 to 79

Who may be able to join

  • Age between 18 and 79 years; No abnormalities found in physical examination; Signed informed consent form.

Who cannot join

  • Previous or current cardiovascular or cerebrovascular diseases; Carotid intima-media thickness (IMT) ≥ 1.0 mm or plaque; Arrhythmia; ④ BMI > 35 kg/m²; Pregnancy.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

China1 site
  • Xuzhou Medical University Affiliated Suqian Hospital

    Suqian, Jiangsu, 223800

    Ming Sun, Doctor, 86-15951299800, sunming103674@yzu.edu.cn

Other trials in China

About this study

observational study The purpose of this observational study is to clarify the consistency, accuracy, and reproducibility of portable patch carotid ultrasound (CADFlow) compared to desktop ultrasound machines in detecting cardiac output (CO), peak velocity (Vmax), and minimum velocity (Vmin) in healthy volunteers.

Read the detailed description

Parameters including cardiac output (CO), peak carotid artery velocity (Vmax), and minimum velocity (Vmin) were monitored in healthy subjects using a portable patch-type carotid ultrasound device (CADFlow). The subjects were placed in a supine position with the head rotated 30° to the contralateral side and the neck slightly extended. The dual-patch probe was then attached to the sites of the most prominent bilateral carotid artery pulsations. The automatic measurement mode was initiated to record blood flow waveforms for 60 seconds. After 30 minutes, the same subjects underwent reassessment of the aforementioned parameters using a conventional ultrasound system. The distal internal diameters of the bilateral common carotid arteries were measured in two-dimensional mode (mean of three measurements). Using pulsed-wave Doppler with an insonation angle ≤60°, Vmax and Vmin were recorded over three consecutive cardiac cycles. The probe was subsequently switched to a transthoracic cardiac probe for CO measurement at the left ventricular outflow tract (LVOT) (mean of three consecutive measurements). The order in which the subjects were monitored with the two devices was randomized.

Being tested
Evaluating the Consistency and Accuracy of Two Devices in Monitoring Hemodynamic Parameters, Hemodynamic monitoring

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Evaluating the Consistency and Accuracy of Two Devices in Monitoring Hemodynamic ParametersDiagnostic test

    This portable patch-type carotid ultrasound has not yet been used in clinical settings.

  • Hemodynamic monitoringDevice

    Whether the parameters monitored by portable patch-based ultrasound devices agree with the gold standard has not yet been thoroughly validated

Study groups in NCT07197411
Study groupRoleWhat they receive
cohort of healthy adultsMonitoring hemodynamic parameters in healthy subjects using two distinct devices
Receives: Diagnostic Test: Evaluating the Consistency and Accuracy of Two Devices in Monitoring Hemodynamic Parameters; Device: Hemodynamic monitoring

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Evaluation of Consistency Between Two Devices

    Hemodynamic parameters, including cardiac output (CO), peak carotid artery velocity (Vmax), and minimum velocity (Vmin), were monitored in healthy subjects using both a portable patch-based ultrasound device and a conventional console ultrasound machine. The agreement and accuracy between the two devices were evaluated by comparing the correlation coefficients of the parameters and analyzing the mean bias using Bland-Altman plots

    Measured: through study completion, an average of six months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Sep 2025
  2. Study start1 Oct 2025 (estimated)
  3. Primary completion31 Dec 2025 (estimated)
  4. Study completion31 Dec 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case-control
Time perspective
Prospective
Enrolment
140 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07197411
Sponsor's protocol ID
202509141301
Status last verified
Sep 2025
First submitted
14 Sep 2025
Last updated
29 Sep 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Device Replacement, run by Xuzhou Medical University Affiliated Suqian Hospital at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 29 Sep 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact MPH (86-15051314834, zhshqin@outlook.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Evaluation of Consistency Between Two Devices (time frame: through study completion, an average of six months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Sep 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in