Evaluation of the Scanning Accuracy of Scanners Operating With Different Scanning Technologies in Mandibular and Maxillary Edentulous Ridges

A study testing Trios 5, iTero Lumina and Medit i700 in people with Accuracy and Measurement Reliability, run by Ege University at 1 site in Turkey (Türkiye).

Active, not recruiting

Under way, not looking for participants. Everyone needed has enrolled. The study is still running.

Official record
Search all trials

Trial summary

This study aims to evaluate the scanning accuracy of scanners equipped with Active Triangulation, Confocal Microscopy, and Multi-Direct-Capture technologies. Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University , 30 patients who applied for a complete removable denture and met the inclusion… Read more about this study

Who is it for?
Ages 18 to 80 years
Conditions the study is for
Accuracy, Measurement Reliability
What is being tested?
Trios 5, iTero Lumina and Medit i700
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteTurkey (Türkiye)
Study dates
10 Apr 2025to Feb 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Individuals aged 18 to 80
  • Upper and lower edentulous ridges
  • Individuals who have not received radiation therapy or chemotherapy
  • Individuals who have not been diagnosed with dry mouth
  • Individuals without active mouth sores due to systemic diseases
  • Patients who accept the study conditions will be included in the study.

Who cannot join

  • Patients whose extraction site has not yet healed or whose last tooth extraction was less than 2 months ago
  • Individuals who have undergone radiation therapy and chemotherapy
  • Individuals diagnosed with dry mouth
  • Individuals with active mouth sores due to systemic diseases
  • Patients who do not agree to the study conditions will not be included in the study.

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Ege University,Faculty of Dentistry,Department of Prosthodontics,Izmir

    Izmir

Other trials in Turkey (Türkiye)

About this study

Official title: In Vivo Evaluation of the Scanning Accuracy of Scanners Operating With Different Scanning Technologies in Mandibular and Maxillary Edentulous Ridges

This study aims to evaluate the scanning accuracy of scanners equipped with Active Triangulation, Confocal Microscopy, and Multi-Direct-Capture technologies.

Department of Prosthetic Dentistry, Faculty of Dentistry, Ege University , 30 patients who applied for a complete removable denture and met the inclusion criteria will have conventional impressions taken. The resulting master model (reference scan) will be scanned using an industrial scanner with high scanning accuracy (E4 lab scanner, 3shape, Denmark) to obtain digital data. Edentulous ridges; Active Triangulation (Medit i700, Seoul, South Korea), Confocal Microscopy (Trios 5, Henry Schein Dental, Gillingham, Kent, UK), and Multi-Direct-Capture technologies (iTero Lumina, Align Technologies, San Jose, California, USA) will be scanned three times using the scanning protocols recommended by the manufacturers and digitized. All digital data obtained will be evaluated using Geomagic (Studio 2015; 3D Systems Inc., Darmstadt, Germany) 3D analysis software to match the reference data and verify its accuracy according to the accepted reference measurement.

Read the detailed description

At Ege University Faculty of Dentistry Department of Prosthodontics, Type 4 (hard) plaster will be used to obtain models by taking impressions with Type A silicone impression material from 30 patients undergoing treatment for lower and/or upper complete (total) dentures who meet the inclusion criteria for the study. The model will be scanned using an industrial EOS scanner (E4 lab scanner, 3shape, Denmark). Three digital scans will be taken from each patient using three different IOS scanners (Trios 5 (Henry Schein Dental, Gillingham, Kent, UK), Medit i700 (Seoul, South Korea), and iTero Lumina (Align Technologies, San Jose, California, USA)), with each patient scanned three times using each scanner. The obtained data will be evaluated with a 3D analysis software program (Geomagic Studio 2015; 3D Systems Inc., Darmstadt, Germany) to match the traditional plaster model (reference) data.

For normally distributed data, one-way ANOVA and post hoc Bonferroni test will be performed; for non-normally distributed data, Bonferroni and Kruskal-Wallis tests will be performed. Intergroup comparisons will be tested using the Tukey HSD test. All statistical analyses will be performed using statistical software (IBM SPSS Statistics, v22.0; IBM Corp., USA). It will be investigated whether there is a statistically significant difference in scanning accuracy between the three intraoral scanners.

The study will evaluate three different scanning technologies: Active Triangulation (Medit i700, Seoul, South Korea), Confocal Microscopy technologies (Trios 5, Henry Schein Dental, Gillingham, Kent, UK), and Multi-unit-capture technologies (iTero Lumina, Align Technologies, San Jose, California, USA). A review of the literature reveals that there are few studies evaluating scanners with different technologies in terms of scanning technologies. The aim of this study is to evaluate the accuracy of scanners with different scanning technologies in completely edentulous arches.

Being tested
Trios 5, iTero Lumina, Medit i700, E4 Lab Scanner
Keywords
intra-oral scanner, digital impression, Complete Edentulism

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Trios 5Other

    Each patient's edentulous ridges are planned to be scanned three times with Trios 5.To ensure optimum accuracy, scans were performed in a standard dark environment in accordance with the manufacturer's scanning protocols.

  • iTero LuminaOther

    Each patient's edentulous ridges are planned to be scanned three times with iTero Lumina.To ensure optimum accuracy, scans were performed in a standard dark environment in accordance with the manufacturer's scanning protocols.

  • Medit i700Other

    Each patient's edentulous ridges are planned to be scanned three times with Medit i700.To ensure optimum accuracy, scans were performed in a standard dark environment in accordance with the manufacturer's scanning protocols.

  • E4 Lab ScannerOther

    Conventional measurements will be taken from each patient, and the resulting master model (reference scan) will be scanned using an industrial scanner with high scanning accuracy (E4 lab scanner, 3shape, Denmark) to obtain digital data.

Study groups in NCT07209826
Study groupRoleWhat they receive
Trios 5 Intra-oral scannerExperimentalIt is an intraoral scanner that works with confocal microscopy scanning technology. The purpose of using the intraoral scanner in our work is to take intraoral digital measurements by scanning edentulous ridges. They record the patient's intraoral images in high resolution.
Receives: Other: iTero Lumina; Other: Medit i700; Other: E4 Lab Scanner
Medit i700 Intra-oral ScannerExperimentalIt is an intraoral scanner that works with active triangulation scanning technology. In our study, the purpose of using the intraoral scanner is to take intraoral digital measurements by scanning edentulous ridges. They record the patient's intraoral images in high resolution.
Receives: Other: Trios 5; Other: iTero Lumina; Other: E4 Lab Scanner
iTero Lumina Intra-oral ScannerExperimentalIt is an intraoral scanner that works with multi-unit-capture scanning technology. In this study, using the new generation digital scanning technology of iTero Lumina, intraoral digital measurements are taken by scanning edentulous ridges. They record the patient's intraoral images in high resolution.
Receives: Other: Trios 5; Other: Medit i700; Other: E4 Lab Scanner
E4 Lab Scanner Extra-oral ScannerActive comparatorThe 3Shape E4 laboratory scanner (EOS) is a desktop laboratory scanner with an indirect scanning procedure. It features fast and accurate scanning technology. With 3Shape E4 scanners, the scanning process begins as soon as you place the model inside the scanner. It records the digital measurement data of the model. In our study, the primary model (reference scan) obtained by taking conventional measurements from the patient is scanned using a laboratory scanner, and digital data is obtained.
Receives: Other: Trios 5; Other: iTero Lumina; Other: Medit i700

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of Intraoral Scanners Compared With Reference Extraoral Scanner

    The primary outcome is the trueness (accuracy) of three intraoral scanners (Trios 5, Medit i700, iTero Lumina) in capturing edentulous maxillary and mandibular arches. Accuracy will be assessed by comparing the surface deviation of intraoral scan data to the reference dataset obtained from the extraoral laboratory scanner of a conventional stone cast. Mean root-mean-square (RMS) error values (measured in micrometers, µm) will be calculated for each scanner relative to the reference to quantify the deviation.

    Measured: Two months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Oct 2025
  2. Study start10 Apr 2025
  3. Primary completionJan 2026 (estimated)
  4. Study completionFeb 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Non-randomised
Intervention model
Factorial
Masking
None (open label)
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07209826
Sponsor's protocol ID
Ege-DHF-ASN-01
Status last verified
Apr 2025
First submitted
30 Sep 2025
Last updated
7 Oct 2025
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Trios 5, iTero Lumina and Medit i700 in people with Accuracy and Measurement Reliability, run by Ege University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: under way, not looking for participants, as of the sponsor's last update on 7 Oct 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of Intraoral Scanners Compared With Reference Extraoral Scanner (time frame: Two months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Oct 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in