Accuracy and Precision of Noninvasive MeasurementNCT07252869

Evaluation of Impression Accuracy: Digital Scanner Versus Analog Technique

An observational study of Accuracy and Precision of Noninvasive Measurement, run by University of Milan at 1 site in Italy.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this study is to evaluate the accuracy of intraoral impressions obtained using the Trios 3Shape® and Carestream CS 3600™ scanners, as well as traditional analog impressions using polyvinyl siloxane (PVS), in comparison to a gold standard represented by a laboratory scanner in 51 dental models from 42… Read more about this study

Who is it for?
Ages 18 to 80 yearsHealthy volunteers can take part
What is being tested?
impression and Digital impression
How many people
51 participants
Where
1 siteItaly
Study dates
15 Jul 2017to 15 Dec 2022
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: The study population consisted of patients seeking implant treatment at the Implantology and Prosthodontics Department of the Giorgio Vogel Odontostomatological Clinic, ASST Santi Paolo e Carlo, Milan.

Who may be able to join

  • Age between 18 and 80 years;
  • Implant placement in healed bone sites (at least 8 weeks post-tooth extraction or at least 6 months after regenerative procedures), allowing guided implant insertion of at least 3.3 mm in diameter or 8.5 mm in length;
  • Implant site without ongoing infections or dental extraction residues;
  • Good systemic health conditions and adequate oral hygiene;
  • Periapical and periodontal health of opposing teeth/implants in occlusion;
  • Edentulism of at least two adjacent dental elements.

Who cannot join

  • Ongoing diseases requiring prolonged use of corticosteroids;
  • Leukocyte dysfunction or deficiencies;
  • Severe hemophilia;
  • Current pregnancy;
  • Past and/or current head/neck radiotherapy and/or chemotherapy;
  • Renal insufficiency;
Show all 22Show fewer
  • Past and/or current use of bisphosphonates;
  • Uncompensated endocrine disorders;
  • Physical disabilities preventing adequate oral hygiene;
  • Alcohol abuse and drug use;
  • Smokers (>10 cigarettes/day);
  • Untreated periodontitis;
  • Mucosal diseases (e.g., erosive Lichen Planus);
  • Severe parafunctional habits (e.g., bruxism or clenching);
  • Persistent intraoral infections;
  • Allergies or adverse reactions to restorative materials;
  • Completely edentulous arches;
  • Limited mouth opening;
  • Inadequate oral hygiene or lack of motivation for self-care;
  • Uncontrolled systemic diseases;
  • Untreated or chronic oral cavity diseases;
  • Fully edentulous arches.

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • Clinica Odontoiatrica Giorgio Vogel (Università degli studi di Milano)

    Milan, Italy

Other trials in Italy

About this study

Official title: Evaluation of the Accuracy of Intraoral Scanner Versus Analog Impression in Implant Supported Rehabilitations Performed With Flapless Computer-Guided Implantology

The goal of this study is to evaluate the accuracy of intraoral impressions obtained using the Trios 3Shape® and Carestream CS 3600™ scanners, as well as traditional analog impressions using polyvinyl siloxane (PVS), in comparison to a gold standard represented by a laboratory scanner in 51 dental models from 42 patients affected by partial edentulism who required at least two implants.

Researchers compare Trios 3Shape®, Carestream CS 3600™ and polyvinyl siloxane (PVS) to see if there is a different accuracy.

Being tested
impression, Digital impression

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • impressionOther

    A Comparative Study of Digital Versus Analog Impressions

  • Digital impressionOther

    impression taken by intraoral scanner

Study groups in NCT07252869
Study groupRoleWhat they receive
TRIOS®-3Shape GroupParticipants whose models were scanned using the TRIOS®-3Shape intraoral digital scanner. The deviation from the reference model was calculated to assess the accuracy of this technique.
Receives: Other: Digital impression
CS 3600® Carestream GroupParticipants whose models were scanned using the CS 3600® Carestream Dental intraoral scanner. The deviation from the reference model was analyzed to evaluate the technique's precision.
Receives: Other: Digital impression
PVS Analog Impression GroupParticipants whose impressions were taken using conventional polyvinylsiloxane (PVS) material. Cast models were scanned and compared to the reference to determine the accuracy of analog impressions.
Receives: Other: impression

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Clinical and radiological evaluation of soft tissues and bone level in implant supported rehabilitations performed with Flapless Computer-Guided implantology. A prospective clinical study.

    The statistical analyses were performed using AnalystSoft StatPlus®. Using GOM Inspect by Zeiss®, the mean deviation values from the reference file were calculated for each model. They were expressed in absolute terms. In our study, for each of the three test techniques (TRIOS®-3Shape, CS 3600® Carestream Dental, and PVS), the average of the values obtained from the superimpositions of 51 models was calculated, resulting in the mean deviation of each method from the reference.

    For data analysis, a one-way ANOVA test and a two-sample Z-test were applied, with a significance level (α) set at 0.05. These tests were used both to compare the mean distances and to assess the standard deviations of the deviations. Each technique was considered accurate if its mean deviation was less than 30 μm.

    Measured: Patients included in this prospective study were recruited from 2017 to 2022

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Nov 2025
  2. Study start15 Jul 2017
  3. Primary completion15 Dec 2022
  4. Study completion15 Dec 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case-control
Time perspective
Cross-sectional
Enrolment
51 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07252869
Sponsor's protocol ID
1361
Status last verified
May 2025
First submitted
21 May 2025
Last updated
28 Nov 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

An observational study of Accuracy and Precision of Noninvasive Measurement, run by University of Milan at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 22 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 28 Nov 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Clinical and radiological evaluation of soft tissues and bone level in implant supported rehabilitations performed with Flapless Computer-Guided implantology. A prospective clinical study. (time frame: Patients included in this prospective study were recruited from 2017 to 2022). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Nov 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in