AzTrials
AzTrials

Clear Aligner TherapyNCT07261735

Clinical Evaluation of Customized Attachment Composites in Clear Aligner Therapy

An observational study of Clear Aligner Therapy and Aligner Attachment Wear, run by Saglik Bilimleri Universitesi at 1 site in Turkey (Türkiye).

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

This prospective observational clinical study aims to evaluate the three-dimensional surface wear and clinical survival of orthodontic attachments fabricated with customized composite materials used in clear aligner therapy. Read more about this study

Who is it for?
Any ageHealthy volunteers can take part
What is being tested?
GC G-ænial A'Chord Universal Composite, Spectra ST HV (High Viscosity) and Spectra ST LV (Low Viscosity)
Type of treatment
Medical device
How many people
24 participants
Where
1 siteTurkey (Türkiye)
Study dates
25 Aug 2025to Dec 2026
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Study population: The study population consists of individuals with fully erupted permanent dentition who are beginning clear aligner treatment at the Gülhane Faculty of Dentistry. Participants are enrolled prospectively after providing written informed consent for participation and for additional follow-up intraoral scans used for attachment wear analysis. Eligible patients present with mild-to-moderate crowding or spacing, show adequate oral hygiene and periodontal health, and have no prosthetic restorations or history of fixed orthodontic treatment. Patients with bruxism, high caries activity, generalized periodontal disease, poor cooperation, or buccal-surface restorations are excluded. As part of routine orthodontic care, all participants receive standardized oral hygiene instructions, including a daily tooth-brushing protocol and recommendations for toothbrush and toothpaste selection. No invasive or non-routine procedures are performed.

Who may be able to join

  • Fully erupted permanent dentition.
  • No existing prosthetic restorations.
  • Mild-to-moderate dental crowding or spacing (2-6 mm).
  • Patients who are scheduled to undergo clear aligner therapy at the Department of Orthodontics, Gülhane Faculty of Dentistry, between 01.08.2025 and 01.08.2026.
  • Patients who agree to participate and provide informed consent.

Who cannot join

  • History of previous fixed orthodontic treatment.
  • Patients with poor predicted compliance or low cooperation.
  • Presence of severe or generalized periodontal disease.
  • High caries incidence or untreated caries.
  • Poor oral hygiene
  • Habitual consumption of hard foods.
Show all 10Show fewer
  • Bruxism
  • Congenitally missing permanent teeth.
  • Dental developmental anomalies.
  • Teeth with existing composite resin restorations or ceramic crowns on buccal surfaces (which may interfere with attachment bonding or wear analysis)

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Gizem Boztaş Demir, Asst. Prof. contact

+905331518464

gizem.demir@sbu.edu.tr

Kübra Gülnur Topsakal, Assoc. Prof. Dr. contact

+905369759013

kubra.topsakal@sbu.edu.tr

Turkey (Türkiye)1 site, 1 recruiting
  • University of Health Sciences, Gülhane Faculty of Dental Medicine

    Ankara, Ankara

    Gizem Demir, Assistant Professor, +905331518464, gizem.demir@sbu.edu.tr

    Kübra Gülnur Topsakal, Associate Professor, +905369759013, kubragulnur.topsakal@sbu.edu.tr

    Recruiting

Other trials in Turkey (Türkiye)

About this study

Official title: Three-Dimensional Evaluation of Wear and Clinical Survival of Attachments Reproduced With Customized Composites for Clear Aligner Therapy: A Prospective Observational Clinical Study

This prospective observational clinical study aims to evaluate the three-dimensional surface wear and clinical survival of orthodontic attachments fabricated with customized composite materials used in clear aligner therapy. Attachments play a critical role in the biomechanical efficiency of aligner treatment by facilitating planned tooth movements. However, the mechanical and surface properties of the composites used for attachment fabrication may affect their wear behavior and long-term stability.

In this study, four different composite materials will be tested using a split-mouth design in patients treated with clear aligners. Each quadrant will receive a different composite, including both customized and universal types. All attachments will be fabricated using standardized digital templates and bonded under identical clinical conditions. Surface wear will be evaluated using three-dimensional optical scanning and metrology software at baseline, 1 week, 1 month, 3 months, and 6 months. Lost attachments will be replaced and recorded but excluded from wear analysis.

The results of this study are expected to provide valuable insights into the optimal material selection for clear aligner attachments, improving treatment accuracy and clinical durability.

Read the detailed description

The study is a prospective, observational, split-mouth clinical investigation conducted at the University of Health Sciences, Gülhane Faculty of Dentistry, Department of Orthodontics. It aims to compare the surface wear resistance and clinical performance of attachments fabricated with different composite resins used in clear aligner therapy.

Four composite materials will be evaluated: GC G-ænial A'Chord (control), Spectra ST HV, Spectra ST LV, and GC Aligner Connect. Each patient will receive four different materials applied to separate quadrants following a randomized split-mouth allocation. The study planning and randomization were performed by a single researcher to ensure methodological consistency. All attachments will be fabricated using standardized digital templates based on the virtual treatment plan. The bonding procedure will be carried out by one investigator using Transbond XT adhesive and 37% phosphoric acid etching for 15 seconds.

Intraoral scanning will be performed at baseline, 1 week, 1 month, 3 months, and 6 months. The scanned data will be analyzed using Zeiss Inspect software to quantify volumetric and surface wear. All 3D alignments and superimpositions will be performed by a blinded evaluator to ensure objectivity. Lost or fractured attachments will be recorded and replaced but excluded from quantitative wear analysis.

All participants will be followed for six months. Statistical analysis will include repeated-measures ANOVA and post-hoc testing with a significance level of p < 0.05. Reliability will be evaluated using the intraclass correlation coefficient (ICC).

This study has been approved by the Gülhane Scientific Research Ethics Committee of the University of Health Sciences (Approval No: 2024/015, August 19, 2025). The findings are expected to enhance understanding of how different composite materials influence attachment wear and longevity in clear aligner therapy, thereby improving the accuracy and clinical predictability of treatment outcomes.

Being tested
GC G-ænial A'Chord Universal Composite, Spectra ST HV (High Viscosity), Spectra ST LV (Low Viscosity), GC Aligner Connect Composite
Keywords
Clear aligner therapy, Orthodontic attachments, Split-mouth design, Customized composites, Surface wear, Clinical survival

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • GC G-ænial A'Chord Universal CompositeDevice

    Universal composite resin used as the control material for attachment reproduction.

  • Spectra ST HV (High Viscosity)Device

    High-viscosity universal composite resin clinically used for clear aligner attachment reproduction.

  • Spectra ST LV (Low Viscosity)Device

    Low-viscosity universal composite resin clinically used for clear aligner attachment reproduction.

  • GC Aligner Connect CompositeDevice

    Customized composite resin specifically developed for clear aligner attachments.

Study groups in NCT07261735
Study groupRoleWhat they receive
Group 1: All ParticipantsAll participants receive four different composite materials using a randomized split-mouth design. Each quadrant is assigned one composite for attachment reproduction
Receives: Device: GC G-ænial A'Chord Universal Composite; Device: Spectra ST HV (High Viscosity); Device: Spectra ST LV (Low Viscosity); Device: GC Aligner Connect Composite

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. 3D Surface Wear of Orthodontic Attachments

    The three-dimensional surface wear of attachments will be evaluated using Zeiss Inspect software (Zeiss GmbH) by comparing baseline (T0) and follow-up scans (T1: 1 week, T2: 1 month, T3: 3 months, T4: 6 months). Wear will be quantified as total surface deviation (sigma) across the entire attachment surface and as point deviations measured at predefined corner and mid-surface points. All 3D alignments and analyses will be performed by an independent, blinded examiner who is unaware of the composite allocation for each quadrant.

    Measured: Baseline to 6 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Dec 2025
  2. Study start25 Aug 2025
  3. Primary completionDec 2026 (estimated)
  4. Study completionDec 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
24 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07261735
Sponsor's protocol ID
SBU-GULHANE-ORTHO-ATTACH-2025
Status last verified
Sep 2026
First submitted
21 Nov 2025
Last updated
22 Sep 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data (IPD) will not be shared due to the inclusion of identifiable intraoral scans, photographs, radiographs, and clinical records that cannot be fully de-identified. In addition, national data protection regulations prohibit the external sharing of personal health information. Only aggregated study results will be made available through scientific publications.

Questions about this trial

What is this clinical trial studying?

An observational study of Clear Aligner Therapy and Aligner Attachment Wear, run by Saglik Bilimleri Universitesi at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 22 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Gizem Boztaş Demir, Asst. Prof. (+905331518464, gizem.demir@sbu.edu.tr), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

3D Surface Wear of Orthodontic Attachments (time frame: Baseline to 6 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Sep 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in