Clinical Effectiveness of a Patient-tailored Orthosis Based on 3-dimensional (3D) Scanner Modeling and 3D Printing Technology for Microstomia Caused by Burns : Pilot Study
A study testing patient's tailored mouthpiece fitting in people with Burn and 3D Printing, run by Hangang Sacred Heart Hospital at 1 site in South Korea.
Trial summary
Mircostomia is not clearly defined in terms of size, but is diagnosed when it causes difficulty in eating, pronounciation, or maintaining oral hygiene. Although various treatments have been applied to microstomia caused by mouth contracture after facial burns, there is no established protocol yet. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Burn, 3D Printing, Microstomia
- What is being tested?
- patient's tailored mouthpiece fitting
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteSouth Korea
- Study dates
- 5 Jul 2025to 30 Jan 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- who underwent skin grafting after suffering from deep second- or third degree burns around the mouth
- who complained of difficulties in daily life such as difficulty in eating, pronunciation, and oral hygine care due to microstomia
Who cannot join
- diagnosed with limited temporomandibular joint movement after or before burn injury
- at risk of skin damage when wearing an open mouthpiece
- with bleeding at the scar site or scar at risk of epidermal damage
- with peripheral vascular diseases with reduced blood circulation
- who withdrew consent.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
About this study
Mircostomia is not clearly defined in terms of size, but is diagnosed when it causes difficulty in eating, pronounciation, or maintaining oral hygiene. Although various treatments have been applied to microstomia caused by mouth contracture after facial burns, there is no established protocol yet. This study aimed to confirm the clinical usefulness of patient-customized mouthpiece using 3D scanner modeling and printing technology.Each participant's mouths were scanned using a 3D scanner (Peel 3, Peel 3D, Canada). The scanned model was imported into the modeling software (Geomagic Design X, 3D Systems, USA). After modeling the mouthpiece to fit the maximum horizontal and vertical length of the mouth and the thickness of the lips, it was manufactured using a 3D printer (Form 4B Medical, Formlabs, USA). The participant was advised to wear the appliance throughout the day except during meals. As a primary outcome, the vertical and horizontal distances of the mouth were measured before and after wearing the patient-customized mouthpiece for 2 months. As secondary outcomes, the biological scar properties, the Vancouver Scar Scale (VSS), and the Patient and Observer Scar Assessment Scale (POSAS) scores were evaluated.
Read the detailed description
Introduction Microstomia is defined as a mouth size that becomes so small that it interferes with oral functions such as oral hygiene care, eating, and speaking with oral function after trauma, facial burns, or surgical procedures for skin cancer, although the exact definition is ambiguous due to cultural differences and standards in each country. Therfore, the diagnosis is defined by functional decline and patient-reported discomfort (1). The cause of microstomia are divided into intraoral and perioral causes. Damage to the sphincter action of the orbicularis oris muscles due to perioral causes, such as burns or trauma, causes contracture which limits lip movement when eating or specking. In the cases of burns around the mouth, the degree of functional impairment varies depending on the extent and depth of the scar. Hypertrophic scars occur in deep second burns or more, and the scar increases as it undergoes the inflammatory, proliferative, and remodeling stages of scar healing. Scar formation increases for several months after burn injury, causing abnormal movement of the surrounding tissue and the scar sites (2). There are various causes of microtomia and various symptoms depending on the severity of the damage, so various attempts are being made to improve the symptoms (3). Conservative treatment generally includes physical therapy and massage to improve facial muscle movement and the use of orthosis to prevent the progression of microstomia. To prevent the progression of microstomia during the healing process of scars after trauma or burns, it is recommended to apply a brace within 10 to 14 days after the injury, but ready-made orthosises are difficult to apply to mouth that are too small, children, or those with severe deformities. The creating of a mouthpiece applied to patient with microstomia in the acute phase is a challenging task tha must be realized to improve clinical outcomes.
Optical three-dimensional (3D) scanning and 3D printing are being used for medical applications such as accurate visualization, precise preoperative anatomical measurements, and patient-specific guides (4). These technologies can be used to manufacture patient-specific orthosis for preventing post burn contractures (5). The technologies have the advantage of saving time and cost in the production of personalized devices and of being able to accurately measure the paricipant's body (6, 7). 3D scanning and printing technology is used for patient-specific body measurements on curved body parts such as the face, hands, and neck, which are difficult to apply with ready-made orthosis (5, 6, 8, 9). The ideal personalized 3D orthosis wound be created by scanning to get the most realistic and accurate outline of the body (10).
There has been little research on the use of 3D scanning modeling technology to produce mouthpiece for patients with microstomia caused by surgery including split thickness skin grafting after burns or cancer operations. This study aimed to confirm the clinical effectiveness of applying patient-tailored mouthpiece using 3D scanning and 3D printing technology to microstomia caused by burns.
Material and Methods Study design This was a pilot study. The protocol was approved by out institution's research ethics committee and registered in ClinicalTrials. The study adhered to the principles of the Declaration of Helsinki, and informed consent was obtained from all participants prior to enrollment. This was conducted in compliance with the TITAN Guidelines 2025 (11).
Participants All participants were admitted to the Department of Rehabilitation Medicine for the first time after complete epithelialization of the wound. Eligible inclusion criteria are defined as participants who underwent skin grafting after suffering from deep second- or third degree burns around the mouth, and who complained of difficulties in daily life such as difficulty in eating, pronunciation, and oral hygine care due to microstomia (Figure 1). Exclusion criteria included patients diagnosed with limited temporomandibular joint movement after or before burn injury, at risk of skin damage when wearing an open mouthpiece, with bleeding at the scar site or scar at risk of epidermal damage, with peripheral vascular diseases with reduced blood circulation, and who withdrew consent.
Manufacturing patient-tailored mouthpiece using 3D modeling technology Each participant's mouths were scanned using a 3D scanner (Peel 3, Peel 3D, Canada) with a mesh resolution of 0.25 mm to create the mouthpiece model. Optical 3D scanning took 15 minutes, including setup. The scanned model was exported in (STL file) format. The model was imported into the modeling software (Geomagic Design X, 3D Systems, USA), in which sculpt mode was selected for further processing. 'Mouthpiece' tool was then selected followed by manual highlighting of the area of interest which included the following zones; the longest horizontal and vertical length of the mouth, and lip thickness. Computer-aided design (CAD) was completed in approximately 2 hours by using CAD model creation software Geomagic Design X®. The resulting mouthpiece was exported as .STL file. The STL file was imported into PreForm software, oriented and support was generated, and the print job was sent to the 3D printer. The mouthpiece part was printed using a Stereo Lithography Apparatus(SLA) 3D printer (Form 4B Medical, Formlabs, USA) that uses a light source to cure liquid resin, and the material was a high-strength biocompatible photopolymer resin (BioMed Clear Resin) (12). 3D printing of the mouthpiece took approximately 1 hour and 30 minutes. The printed part was placed in a Formlabs-validated wash unit (Form Wash, Formlabs, USA) containing 99% isopropyl alcohol for 15 minutes or until clean. Remove the part from the wash unit and soak in fresh isopropyl alcohol for 5 minutes. Remove the part and let it air dry at room temperature for at least 30 minutes. Place the dried part in a Formlabs-validated post-curing unit (Form Cure, Formlabs, USA) and cure at 60°C for 60 minutes. After the support of the cured mouthpiece was removed with a part removal tool or by hand, and then sanded smooth with sandpaper to improve the surface finish (Figure 2).
Intervention The participant was advised to wear the appliance throughout the day except during meals. The maximaum horizontal and vertical distances were measured every two weeks to assess whether the mouthpiece had the ability to stretch against the scar. If the patient found it easy to wear or there was no stretching effect, the patient-tailored mouthpiece was remade.
All participants had the same daily schedule and performed their daily routine, including eating, showering, rehabilitation therapy, and scar management such as using moisturizing cream. Nonsurgical treatments such as intralesional steroid injection, moisturization, massage, silicone apply, and compression garment were maintained to suppress hypertrophic scars during the period of wearing the mouthpiece.
Outcome measurements A clinical researcher conducted a blind assessment of scar biological properties before applying the mouthpiece and after application. As a primary outcome, the vertical and horizontal lengths of the mouth were measured before and after wearing the patient-customized mouthpiece for 2 months. As defined previously in the article, vertical mouth opening range wea recorded as the measurement in millimeters from the inner border of the medial top lip to the inner border of the medial lower lip whilist in the stretched position. Horizontal mouth opening range was recorded as the measurement in millimeters from one lateral oral commissure to the other lateral oral commissure whilst in the stretched position (Figure 3) (13). As secondary outcomes, the biological scar properties, the Vancouver Scar Scale (VSS), and the Patient and Observer Scar Assessment Scale (POSAS) scores were evaluated before and after applying the mouthpiece for 2 months. The VSS was used to assess and evaluate scar severity. Scar evaluation involved individual assessment of four factors; pigmentation, vascularity, pliability, and scar height (thickness). Each parameter was scored on a scale from 0 to3 or 0 to 5, with 0 representing normal skin and higher scores indicating increased severity or deviation from normality. The total score was calculated by summing the individual scores for each parameter, providing an overall assessment of scar severity (14). The POSAS is a consistent and reliable tool designed to assess scars, particularly burn scars, from both the patient's and observer's perspectives. It consists of two numeric scale; one for patients, encompassing six parameters, and the other for observers, comprising five parameters (15).
The space for skin examination was maintained at 40~50% humidity and 20~25'C (16). Scar thickness was quantified using ultrasonography (128 BW1 US system, Medison, Korea) (8). The Mexameter® (MX18, Courage-Khazaka Electronics GmbH, Köln, Germany) was used to measure melanin levels and erythema severity. Higher values indicated greater pigmentation and redness. Trans-epidermal water loss (TEWL) was measured using a Tewameter® (Courage-Khazaka Electronic GmbH, Köln, Germany) to evaluate water evaporation. Possible complications, including pain, ecchymosis, skin abrasion, and swelling, were also monitored.
Statistical analysis Statistical analysis was performed using SPSS 23.0 (IBM Corporation, Armonk, NY, USA). Due to the small sample size, nonparametric methods were applied. The Wilcoxon signed-rank test was used for in-group comparisons of the variables. Statistical significance was set at P < 0.05.
- Conditions
- Burn, 3D Printing, Microstomia, Split Thickness Skin Graft
- Being tested
- patient's tailored mouthpiece fitting
- Keywords
- microstomia, mouth, split thickness skin graft, burn, 3D scanner modeling
- Medical subject headings
- Burns, Microstomia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
patient's tailored mouthpiece fittingOther
Manufacturing patient-tailored mouthpiece using 3D modeling technology. The participant was advised to wear the appliance throughout the day except during meals. The maximaum horizontal and vertical distances were measured every two weeks to assess whether the mouthpiece had the ability to stretch against the scar. If the patient found it easy to wear or there was no stretching effect, the patient-tailored mouthpiece was remade.
| Study group | Role | What they receive |
|---|---|---|
| The participant was advised to wear the appliance throughout the day . | Experimental | The participant was advised to wear the appliance throughout the day Receives: Other: patient's tailored mouthpiece fitting |
What is being measured
The primary outcome is the main question the study is designed to answer.
mouth size measurement
vertical mouth opening range wea recorded as the measurement in millimeters from the inner border of the medial top lip to the inner border of the medial lower lip whilist in the stretched position. Horizontal mouth opening range was recorded as the measurement in millimeters from one lateral oral commissure to the other lateral oral commissure whilst in the stretched position
Measured: 2 month
Secondary outcomes (1)
Vancouver Scar Scale (VSS)
The VSS was used to assess and evaluate scar severity. Scar evaluation involved individual assessment of four factors; pigmentation, vascularity, pliability, and scar height (thickness). Each parameter was scored on a scale from 0 to3 or 0 to 5, with 0 representing normal skin and higher scores indicating increased severity or deviation from normality. The total score was calculated by summing the individual scores for each parameter, providing an overall assessment of scar severity
Measured: 2 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 Dec 2025
- Study start5 Jul 2025
- Primary completion30 Dec 2025 (estimated)
- Study completion30 Jan 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for BurnStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Manufacturing patient-tailored mouthpiece using 3D modeling technology. The participant was advised to wear the appliance throughout the day except during meals.
- Masking
- None (open label)
- Enrolment
- 10 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Hangang Sacred Heart Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, So Young Joo, Hangang Sacred Heart Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07264218
- Sponsor's protocol ID
- HangangSHH-21
- Status last verified
- Oct 2025
- First submitted
- 24 Nov 2025
- Last updated
- 4 Dec 2025
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Publications
Singounas EG. Posttraumatic brainstem damage. Surg Neurol. 1986 Sep;26(3):311. doi: 10.1016/0090-3019(86)90171-0. No abstract available.
PubMed 3738730Joo SY, Lee SY, Cho YS, Yi S, Seo CH. Clinical Utility of an Exoskeleton Robot Using Three-Dimensional Scanner Modeling in Burn Patient: A Case Report. J Burn Care Res. 2021 Sep 30;42(5):1030-1034. doi: 10.1093/jbcr/irab060.
PubMed 33881533Ki SH, Jo GY, Yoon J, Choi MSS. Reconstruction of microstomia considering their functional status. Arch Craniofac Surg. 2020 Jun;21(3):161-165. doi: 10.7181/acfs.2020.00220. Epub 2020 Jun 29.
PubMed 32630987Lee SY, Seo CH, Cho YS, Seo J, Bae YD, Joo SY. Clinical effectiveness of a patient-tailored mouthpiece based on 3-dimensional (3D) scanner modeling and 3D printing technology for microstomia caused by burns: A pilot study. Burns. 2026 Jun;52(5):107987. doi: 10.1016/j.burns.2026.107987. Epub 2026 Mar 27.
PubMed 41946292
Study at a glance
From the registry record, last updated by the sponsor on 4 Dec 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Effectiveness of a Patient-tailored Orthosis Based on 3-dimensional (3D) Scanner Modeling and 3D Printing Technology for Microstomia Caused by Burns : Pilot Study
- ClinicalTrials.gov ID
- NCT07264218
- Acronym / sponsor ID
- HangangSHH-21
- Conditions
- Burn, 3D Printing, Microstomia, Split Thickness Skin Graft
- Keywords
- microstomia, mouth, split thickness skin graft, burn, 3D scanner modeling
- Study type
- Interventional
- Recruitment status
- Enrolling by invitation
- Enrolment
- 10 participants (estimated)
- Lead sponsor
- Hangang Sacred Heart HospitalUniversity, hospital or other
- Study start
- 5 Jul 2025 (actual)
- Primary completion
- 30 Dec 2025 (estimated)
- Study completion
- 30 Jan 2026 (estimated)
- First posted
- 4 Dec 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Mircostomia is not clearly defined in terms of size, but is diagnosed when it causes difficulty in eating, pronounciation, or maintaining oral hygiene. Although various treatments have been applied to microstomia caused by mouth contracture after facial burns, there is no established protocol yet. This study aimed to confirm the clinical usefulness of patient-customized mouthpiece using 3D scanner modeling and printing technology.Each participant's mouths were scanned using a 3D scanner (Peel 3, Peel 3D, Canada). The scanned model was imported into the modeling software (Geomagic Design X, 3D Systems, USA). After modeling the mouthpiece to fit the maximum horizontal and vertical length of the mouth and the thickness of the lips, it was manufactured using a 3D printer (Form 4B Medical, Formlabs, USA). The participant was advised to wear the appliance throughout the day except during meals. As a primary outcome, the vertical and horizontal distances of the mouth were measured before and after wearing the patient-customized mouthpiece for 2 months. As secondary outcomes, the biological scar properties, the Vancouver Scar Scale (VSS), and the Patient and Observer Scar Assessment Scale (POSAS) scores were evaluated.
Detailed description
Introduction Microstomia is defined as a mouth size that becomes so small that it interferes with oral functions such as oral hygiene care, eating, and speaking with oral function after trauma, facial burns, or surgical procedures for skin cancer, although the exact definition is ambiguous due to cultural differences and standards in each country. Therfore, the diagnosis is defined by functional decline and patient-reported discomfort (1). The cause of microstomia are divided into intraoral and perioral causes. Damage to the sphincter action of the orbicularis oris muscles due to perioral causes, such as burns or trauma, causes contracture which limits lip movement when eating or specking. In the cases of burns around the mouth, the degree of functional impairment varies depending on the extent and depth of the scar. Hypertrophic scars occur in deep second burns or more, and the scar increases as it undergoes the inflammatory, proliferative, and remodeling stages of scar healing. Scar formation increases for several months after burn injury, causing abnormal movement of the surrounding tissue and the scar sites (2). There are various causes of microtomia and various symptoms depending on the severity of the damage, so various attempts are being made to improve the symptoms (3). Conservative treatment generally includes physical therapy and massage to improve facial muscle movement and the use of orthosis to prevent the progression of microstomia. To prevent the progression of microstomia during the healing process of scars after trauma or burns, it is recommended to apply a brace within 10 to 14 days after the injury, but ready-made orthosises are difficult to apply to mouth that are too small, children, or those with severe deformities. The creating of a mouthpiece applied to patient with microstomia in the acute phase is a challenging task tha must be realized to improve clinical outcomes.
Optical three-dimensional (3D) scanning and 3D printing are being used for medical applications such as accurate visualization, precise preoperative anatomical measurements, and patient-specific guides (4). These technologies can be used to manufacture patient-specific orthosis for preventing post burn contractures (5). The technologies have the advantage of saving time and cost in the production of personalized devices and of being able to accurately measure the paricipant's body (6, 7). 3D scanning and printing technology is used for patient-specific body measurements on curved body parts such as the face, hands, and neck, which are difficult to apply with ready-made orthosis (5, 6, 8, 9). The ideal personalized 3D orthosis wound be created by scanning to get the most realistic and accurate outline of the body (10).
There has been little research on the use of 3D scanning modeling technology to produce mouthpiece for patients with microstomia caused by surgery including split thickness skin grafting after burns or cancer operations. This study aimed to confirm the clinical effectiveness of applying patient-tailored mouthpiece using 3D scanning and 3D printing technology to microstomia caused by burns.
Material and Methods Study design This was a pilot study. The protocol was approved by out institution's research ethics committee and registered in ClinicalTrials. The study adhered to the principles of the Declaration of Helsinki, and informed consent was obtained from all participants prior to enrollment. This was conducted in compliance with the TITAN Guidelines 2025 (11).
Participants All participants were admitted to the Department of Rehabilitation Medicine for the first time after complete epithelialization of the wound. Eligible inclusion criteria are defined as participants who underwent skin grafting after suffering from deep second- or third degree burns around the mouth, and who complained of difficulties in daily life such as difficulty in eating, pronunciation, and oral hygine care due to microstomia (Figure 1). Exclusion criteria included patients diagnosed with limited temporomandibular joint movement after or before burn injury, at risk of skin damage when wearing an open mouthpiece, with bleeding at the scar site or scar at risk of epidermal damage, with peripheral vascular diseases with reduced blood circulation, and who withdrew consent.
Manufacturing patient-tailored mouthpiece using 3D modeling technology Each participant's mouths were scanned using a 3D scanner (Peel 3, Peel 3D, Canada) with a mesh resolution of 0.25 mm to create the mouthpiece model. Optical 3D scanning took 15 minutes, including setup. The scanned model was exported in (STL file) format. The model was imported into the modeling software (Geomagic Design X, 3D Systems, USA), in which sculpt mode was selected for further processing. 'Mouthpiece' tool was then selected followed by manual highlighting of the area of interest which included the following zones; the longest horizontal and vertical length of the mouth, and lip thickness. Computer-aided design (CAD) was completed in approximately 2 hours by using CAD model creation software Geomagic Design X®. The resulting mouthpiece was exported as .STL file. The STL file was imported into PreForm software, oriented and support was generated, and the print job was sent to the 3D printer. The mouthpiece part was printed using a Stereo Lithography Apparatus(SLA) 3D printer (Form 4B Medical, Formlabs, USA) that uses a light source to cure liquid resin, and the material was a high-strength biocompatible photopolymer resin (BioMed Clear Resin) (12). 3D printing of the mouthpiece took approximately 1 hour and 30 minutes. The printed part was placed in a Formlabs-validated wash unit (Form Wash, Formlabs, USA) containing 99% isopropyl alcohol for 15 minutes or until clean. Remove the part from the wash unit and soak in fresh isopropyl alcohol for 5 minutes. Remove the part and let it air dry at room temperature for at least 30 minutes. Place the dried part in a Formlabs-validated post-curing unit (Form Cure, Formlabs, USA) and cure at 60°C for 60 minutes. After the support of the cured mouthpiece was removed with a part removal tool or by hand, and then sanded smooth with sandpaper to improve the surface finish (Figure 2).
Intervention The participant was advised to wear the appliance throughout the day except during meals. The maximaum horizontal and vertical distances were measured every two weeks to assess whether the mouthpiece had the ability to stretch against the scar. If the patient found it easy to wear or there was no stretching effect, the patient-tailored mouthpiece was remade.
All participants had the same daily schedule and performed their daily routine, including eating, showering, rehabilitation therapy, and scar management such as using moisturizing cream. Nonsurgical treatments such as intralesional steroid injection, moisturization, massage, silicone apply, and compression garment were maintained to suppress hypertrophic scars during the period of wearing the mouthpiece.
Outcome measurements A clinical researcher conducted a blind assessment of scar biological properties before applying the mouthpiece and after application. As a primary outcome, the vertical and horizontal lengths of the mouth were measured before and after wearing the patient-customized mouthpiece for 2 months. As defined previously in the article, vertical mouth opening range wea recorded as the measurement in millimeters from the inner border of the medial top lip to the inner border of the medial lower lip whilist in the stretched position. Horizontal mouth opening range was recorded as the measurement in millimeters from one lateral oral commissure to the other lateral oral commissure whilst in the stretched position (Figure 3) (13). As secondary outcomes, the biological scar properties, the Vancouver Scar Scale (VSS), and the Patient and Observer Scar Assessment Scale (POSAS) scores were evaluated before and after applying the mouthpiece for 2 months. The VSS was used to assess and evaluate scar severity. Scar evaluation involved individual assessment of four factors; pigmentation, vascularity, pliability, and scar height (thickness). Each parameter was scored on a scale from 0 to3 or 0 to 5, with 0 representing normal skin and higher scores indicating increased severity or deviation from normality. The total score was calculated by summing the individual scores for each parameter, providing an overall assessment of scar severity (14). The POSAS is a consistent and reliable tool designed to assess scars, particularly burn scars, from both the patient's and observer's perspectives. It consists of two numeric scale; one for patients, encompassing six parameters, and the other for observers, comprising five parameters (15).
The space for skin examination was maintained at 40~50% humidity and 20~25'C (16). Scar thickness was quantified using ultrasonography (128 BW1 US system, Medison, Korea) (8). The Mexameter® (MX18, Courage-Khazaka Electronics GmbH, Köln, Germany) was used to measure melanin levels and erythema severity. Higher values indicated greater pigmentation and redness. Trans-epidermal water loss (TEWL) was measured using a Tewameter® (Courage-Khazaka Electronic GmbH, Köln, Germany) to evaluate water evaporation. Possible complications, including pain, ecchymosis, skin abrasion, and swelling, were also monitored.
Statistical analysis Statistical analysis was performed using SPSS 23.0 (IBM Corporation, Armonk, NY, USA). Due to the small sample size, nonparametric methods were applied. The Wilcoxon signed-rank test was used for in-group comparisons of the variables. Statistical significance was set at P < 0.05.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Manufacturing patient-tailored mouthpiece using 3D modeling technology. The participant was advised to wear the appliance throughout the day except during meals.
| Arm | Type | Receives |
|---|---|---|
| The participant was advised to wear the appliance throughout the day . | Experimental | Other: patient's tailored mouthpiece fittingThe participant was advised to wear the appliance throughout the day |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (2 listed)
- who underwent skin grafting after suffering from deep second- or third degree burns around the mouth
- who complained of difficulties in daily life such as difficulty in eating, pronunciation, and oral hygine care due to microstomia
Key exclusion criteria (5 listed)
- diagnosed with limited temporomandibular joint movement after or before burn injury
- at risk of skin damage when wearing an open mouthpiece
- with bleeding at the scar site or scar at risk of epidermal damage
- with peripheral vascular diseases with reduced blood circulation
- who withdrew consent.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| patient's tailored mouthpiece fittingManufacturing patient-tailored mouthpiece using 3D modeling technology. The participant was advised to wear the appliance throughout the day except during meals. The maximaum horizontal and vertical distances were measured every two weeks to assess whether the mouthpiece had the ability to stretch against the scar. If the patient found it easy to wear or there was no stretching effect, the patient-tailored mouthpiece was remade. | Other | The participant was advised to wear the appliance throughout the day . |
Primary outcome
mouth size measurement
Time frame: 2 month
vertical mouth opening range wea recorded as the measurement in millimeters from the inner border of the medial top lip to the inner border of the medial lower lip whilist in the stretched position. Horizontal mouth opening range was recorded as the measurement in millimeters from one lateral oral commissure to the other lateral oral commissure whilst in the stretched position
1 secondary outcome
Vancouver Scar Scale (VSS)
Time frame: 2 months
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 4 Dec 2025.
- Results publication: PubMed 3738730Singounas EG. Posttraumatic brainstem damage. Surg Neurol. 1986 Sep;26(3):311. doi: 10.1016/0090-3019(86)90171-0. No abstract available.
- Results publication: PubMed 33881533Joo SY, Lee SY, Cho YS, Yi S, Seo CH. Clinical Utility of an Exoskeleton Robot Using Three-Dimensional Scanner Modeling in Burn Patient: A Case Report. J Burn Care Res. 2021 Sep 30;42(5):1030-1034. doi: 10.1093/jbcr/irab060.
- Results publication: PubMed 32630987Ki SH, Jo GY, Yoon J, Choi MSS. Reconstruction of microstomia considering their functional status. Arch Craniofac Surg. 2020 Jun;21(3):161-165. doi: 10.7181/acfs.2020.00220. Epub 2020 Jun 29.
- Derived from this study: PubMed 41946292Lee SY, Seo CH, Cho YS, Seo J, Bae YD, Joo SY. Clinical effectiveness of a patient-tailored mouthpiece based on 3-dimensional (3D) scanner modeling and 3D printing technology for microstomia caused by burns: A pilot study. Burns. 2026 Jun;52(5):107987. doi: 10.1016/j.burns.2026.107987. Epub 2026 Mar 27.
- Individual participant dataSharing planned: Undecided
Related trials for Burn
RecruitingObservational study
Early Detection and Kinetics of Sepsis-Induced Coagulopathy in Severe Burn Patients
Sepsis, Sepsis-induced Coagulopathy
Not yet recruitingObservational study
Hypertrophic Scar Prosthetic Pressure in Burn Amputee
Amputation Stump, Burn Injury
Not yet recruiting
Effect of Short-Video Distraction During Burn Dressing on Anxiety, Pain, and Fear in Children
Burn Injury, Procedural Anxiety
RecruitingObservational study
Early Detection and Kinetics of Sepsis-Induced Coagulopathy in Severe Burn Patients
Peer Bullying Intervention, Vodcast
RecruitingPhase 2
Dupixent in Adults With Refractory Post-Burn Pruritus in an Ambulatory Clinic
Pruritis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing patient's tailored mouthpiece fitting in people with Burn and 3D Printing, run by Hangang Sacred Heart Hospital at 1 site in South Korea.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: enrolling by invitation, as of the sponsor's last update on 4 Dec 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
mouth size measurement (time frame: 2 month). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07264218, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Dec 2025.