Medical ImagingNR SpectralNCT07305103
Defining Dosimetric Reference Levels in Computed Tomography Spectral Scanning
An observational study of Medical Imaging, run by Centre Hospitalier Universitaire de Nīmes at 1 site in France.
Trial summary
Spectral computed tomography or dual-energy CT imaging can overcome the limitations of conventional CT in differentiating between two materials with equivalent total attenuation. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Medical Imaging
- What is being tested?
- Spectral ComputedTomography
- Type of treatment
- Injection or infusion, Surgery or procedure
- How many people
- 9,600 participants
- Where
- 1 siteFrance
- Study dates
- 1 Sep 2025to 30 Jun 2027
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: All adult patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.
Who may be able to join
- Adult male/female patient (≥ 18 years old)
- Body Mass Index (BMI) between 18 and 35 kg/m²
- Patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.
Who cannot join
- Pregnant women
Trial locations and contacts
1 site in 1 country.
About this study
Spectral computed tomography or dual-energy CT imaging can overcome the limitations of conventional CT in differentiating between two materials with equivalent total attenuation. It can generate several types of images, such as virtual monochromatic images, which improve the contrast-to-noise ratio for low energy levels and reduce artifacts for high energy levels. It also allows for quantitative image analysis and thus better characterization of lesions and tissues through material mapping (e.g., iodinated contrast agent mapping). This technique is increasingly used in routine clinical practice thanks to improvements in image flow management and technological advances. It also involves exposing patients to ionizing radiation, as with conventional CT but, unlike conventional CT scans, for which dosimetric reference levels (RLs) are defined for the most common examinations in France (RL decree dated 2019), there are currently no dosimetric reference levels for examinations performed using this technique. Yet RLs are an important and effective tools for optimizing patient exposure to ionizing radiation. Several articles were published between 2012 and 2017 when the first dual-energy scanners arrived in clinics. However, the results presented in these studies are now far removed from recent practices, as they do not take into account the latest technological developments used in dual-energy scanners, which reduce X-ray doses.
The main objective of the study is to define dosimetric reference levels for the most commonly performed spectral computed tomography examinations in France.
Read the detailed description
Spectral computed tomography (CT) (or dual-energy CT) imaging can overcome the limitations of conventional CT in differentiating between two materials with equivalent total attenuation. It can generate several types of images, such as virtual monochromatic images, which improve the contrast-to-noise ratio for low energy levels and reduce artifacts for high energy levels. It also allows for quantitative image analysis and thus better characterization of lesions and tissues through material mapping (e.g., iodinated contrast agent mapping). This technique is increasingly used in routine clinical practice thanks to improvements in image flow management and technological advances. It also involves exposing patients to ionizing radiation, as with conventional CT.
However, unlike conventional CT scans, for which dosimetric reference levels (RLs) are defined for the most common examinations in France (RL decree dated 2019), there are currently no dosimetric reference levels for examinations performed using this technique. Yet the RL is an important and effective tool in optimizing patient exposure to ionizing radiation. In fact, a number of articles were published between 2012 and 2017, when the first dual-energy scanners arrived in clinics. However, the results presented in these studies are now far removed from recent practices, as they do not take into account the latest technological developments used in dual-energy scanners, which reduce X-ray doses.
The main objective of the study is to define dosimetric reference levels for the most frequently performed spectral computed tomography examinations in France:
- Chest CT for pulmonary embolism
- Chest CT for other indications
- Coronary CT with contrast injection and retrospective gating
- Coronary CT with contrast injection and prospective gating
- Cranial CT with contrast injection
- Supra-aortic trunk CT
- Neck and ear,nose and throat sphere CT with contrast injection
- Oncological abdomen-pelvis CT scan
- Abdomen-pelvis CT scan to check for kidney stones
- Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones
- Oncological chest-abdomen-pelvis CT scan
- Non-oncological chest-abdomen-pelvis CT scan
- Oncological chest-abdomen CT scan
- Non-oncological chest-abdomen CT scan
- Lower limb angiography
- Cervical spine CT scan
- Thoracic spine CT scan
- Lumbar spine CT scan
- Pelvis CT scan,
- Extremities CT scan
The secondary objectives of the study are to evaluate, for each examination performed:
- the impact of the spectral acquisition/detection technique on the dose delivered to patients.
- the impact of patients' BMI on the dose delivered to patients.
- the impact of reconstruction algorithms on the dose delivered to patients.
- Conditions
- Medical Imaging
- Being tested
- Spectral ComputedTomography
- Keywords
- Radiation dose, Reference levels, Radiology, Spectral Computed Tomography Imaging
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Spectral ComputedTomographyRadiation
Commonly performed spectral computed tomography examinations in France
| Study group | Role | What they receive |
|---|---|---|
| Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below | Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below:
1. Chest CT for pulmonary embolism
2. Chest CT for other indications
3. Coronary CT with contrast injection and retrospective gating
4. Coronary CT with contrast injection and prospective gating
5. Cranial CT with contrast injection
6. Supra-aortic trunk CT
7. Neck and ear,nose and throat sphere CT with contrast injection
8. Oncological abdomen-pelvis CT scan
9. Abdomen-pelvis CT scan to check for kidney stones
10. Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones
11. Oncological chest-abdomen-pelvis CT scan
12. Non-oncological chest-abdomen-pelvis CT scan
13. Oncological chest-abdomen CT scan
14. Non-oncological chest-abdomen CT scan
15. Lower limb angiography
16. Cervical spine CT scan
17. Thoracic spine CT scan
18. Lumbar spine CT scan
19. Pelvis CT scan,
20. Extremities CT scan Receives: Radiation: Spectral ComputedTomography |
What is being measured
The primary outcome is the main question the study is designed to answer.
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and retrospective gating. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and prospective gating. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. DLP
Dose length product (DLP) expressed in mGy.cm
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. CTDIvol
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Measured: Periprocedural
Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. DLP
Dose length product (DLP) expressed in mGy.cm will be recorded
Measured: Periprocedural
Secondary outcomes (183)
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. DLP
Dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters, kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters, mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Chest CT for pulmonary embolism. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, helical pitch
Helical pitch time will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Chest CT for other indications. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. DLP
The dose length product (DLP) will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Acquisition parameters, kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Acquisition parameters, mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. DLP
Dose length product (DLP) will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Acquisition parameters, kV
Acquisition parameters (kV)will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Acquisition parameters, mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Cranial CT with contrast injection. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Supra-aortic trunk CT. Acquisition type
The type of acquisition will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Supra-aortic trunk CT. Number of acquisitions
The number of acquisitions will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Supra-aortic trunk CT. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Supra-aortic trunk CT. DLP
The dose (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Supra-aortic trunk CT. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Supra-aortic trunk CT. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Supra-aortic trunk CT. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Supra-aortic trunk CT. Acquisition parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Supra-aortic trunk CT. Acquisition parameters. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Neck and ear, nose and throat sphere CT with contrast injection. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Neck and ear, nose and throat sphere CT with contrast injection. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Neck and ear, nose and throat sphere CT with contrast injection. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Neck and ear, nose and throat sphere CT with contrast injection. DLP
The dose (DLP) expressed in mGy.cm will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Neck and ear, nose and throat sphere CT with contrast injection. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Neck and ear, nose and throat sphere CT with contrast injection. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological abdomen-pelvis CT scan. Acquisition type
The type of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological abdomen-pelvis CT scan. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological abdomen-pelvis CT scan. CTDIvol
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological abdomen-pelvis CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological abdomen-pelvis CT scan. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological abdomen-pelvis CT scan. Acquisition parameters (kV)
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological abdomen-pelvis CT scan. Acquisition parameters (mAs)
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological abdomen-pelvis CT scan. Acquisition parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological abdomen-pelvis CT scan. Acquisition parameters. Helical pitch
Helical pitch will be recorded will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients: Oncological abdomen-pelvis CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan to check for kidney stones. Acquisition type an
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan to check for kidney stones. Number of acquisitions an
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan to check for kidney stones. CTDIvol an
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan to check for kidney stones. DLP an
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan to check for kidney stones. BMI an
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan to check for kidney stones. Acquisition parameters. Kv an
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan to check for kidney stones. Acquisition parameters. mAs an
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan to check for kidney stones. Rotation time an
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan to check for kidney stones. Helical pitch an
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Abdomen-pelvis CT scan to check for kidney stones. Type of reconstruction algorithm an
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen-pelvis CT scan. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen-pelvis CT scan. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen-pelvis CT scan. CTDIvol
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen-pelvis CT scan. DLP
The dose (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen-pelvis CT scan. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen-pelvis CT scan. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen-pelvis CT scan. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen-pelvis CT scan. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen-pelvis CT scan. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Oncological chest-abdomen-pelvis CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen-pelvis CT scan. Acquisition type.
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen-pelvis CT scan. Number of acquisitions.
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen-pelvis CT scan. CDTIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen-pelvis CT scan. CDTIvol. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen-pelvis CT scan. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen-pelvis CT scan. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen-pelvis CT scan. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen-pelvis CT scan. Acquisition parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen-pelvis CT scan. Acquisition parameters. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Non-oncological chest-abdomen-pelvis CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen CT scan. Aquisition type
The type of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen CT scan. Number of aquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen CT scan. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Oncological chest-abdomen CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen CT scan. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen CT scan. Acquisition parameters (kV)
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen CT scan. Acquisition parameters (mAs)
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen CT scan. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Oncological chest-abdomen CT scan. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Oncological chest-abdomen CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen CT scan. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen CT scan. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen CT scan. CTDIvol
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Non-oncological chest-abdomen CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen CT scan
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen CT scan. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Non-oncological chest-abdomen CT scan. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients: Non-oncological chest-abdomen CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lower limb angiography. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lower limb angiography. Number of acquitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lower limb angiography. CTDIvol
The dose CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lower limb angiography. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lower limb angiography. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lower limb angiography. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lower limb angiography. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lower limb angiography. Rotation time
Rotation time will be recorded in seconds.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lower limb angiography. Helical pitch
Helical pitch will be recorded as a ratio.This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lower limb angiography. Type of reconstruction algorithm
Type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cervical spine CT scan. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cervical spine CT scan. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cervical spine CT scan. CDTIvol
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cervical spine CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Cervical spine CT scan. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Cervical spine CT scan. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Cervical spine CT scan. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Cervical spine CT scan. Acquisition parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Cervical spine CT scan. Acquisition parameters. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Cervical spine CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Thoracic spine CT scan. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Thoracic spine CT scan. Number of acquisitions
The number of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Thoracic spine CT scan. CTDIvol
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Thoracic spine CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Thoracic spine CT scan. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Thoracic spine CT scan. Acquisition parameters (kV)
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Thoracic spine CT scan. Acquisition parameters (mAs)
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Thoracic spine CT scan. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Thoracic spine CT scan. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Thoracic spine CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lumbar spine CT scan. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lumbar spine CT scan. Number of acquisitions
The number of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lumbar spine CT scan. CTDIvol
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Lumbar spine CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lumbar spine CT scan. BMI
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lumbar spine CT scan. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lumbar spine CT scan. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lumbar spine CT scan. Acquisition parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Lumbar spine CT scan. Acquisition parameters. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients: Lumbar spine CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Pelvis CT scan. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Pelvis CT scan. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Pelvis CT scan. CTDIvol
The dose (CDTIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Pelvis CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded.
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Pelvis CT scan. BMI.
Weight and height will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Pelvis CT scan. Acquistion parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Pelvis CT scan. Acquistion parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Pelvis CT scan. Acquistion parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Pelvis CT scan. Acquistion parameters. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Pelvis CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Extremities CT scan. Acquisition type
The type of acquisition will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Extremities CT scan. Number of acquisitions
The number of acquisitions will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Extremities CT scan. CTDIvol
The dose (CTDIvol) will be recorded.
Measured: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Extremities CT scan. DLP
The dose length product (DLP) expressed in mGy.cm will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Extremities CT scan. BMI
Weight in kg and height in cm in will be combined to report BMI in kg/m^2
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Extremities CT scan. Acquisition parameters. kV
Acquisition parameters (kV) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Extremities CT scan. Acquisition parameters. mAs
Acquisition parameters (mAs) will be recorded
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Extremities CT scan. Acquisition parameters. Rotation time
Rotation time will be recorded in seconds
Measured: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Extremities CT scan. Acquisition parameters. Helical pitch
Helical pitch will be recorded as a ratio. This represents the relationship between patient couch movement and X-ray beam width. It is the distance travelled by the table during one 360 degree gantry rotation divided by the collimated section thickness
Measured: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients: Extremities CT scan. Type of reconstruction algorithm
The type of reconstruction algorithm (iterative or deep learning) will be recorded
Measured: Periprocedural
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Dec 2025
- Study start1 Sep 2025
- Primary completion31 Dec 2026 (estimated)
- Study completion30 Jun 2027 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (9)Papers the sponsor has linked to this study.
- Other trials for Medical ImagingStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Retrospective
- Enrolment
- 9,600 participants (actual)
Sponsor and investigators
- Lead sponsor
- Centre Hospitalier Universitaire de Nīmes
- Sponsor type
- University, hospital or other
- Collaborators
- Institut Paoli Calmettes, Marseille, Hôpital Necker-Enfants Malades, University Hospital, Lille, Hopital Lariboisière, Centre Hospitalier Universitaire de Saint Etienne, Saint-Louis Hospital, Paris, France, Bichat Hospital, Hôpital Louis Mourier, 92700 Colombes, Centre Hospitalier de Valenciennes, Hopital Louis Pradel, Centre Léon Bérard, Lyon, University Hospital, Bordeaux, Centre Hospitalier Lyon Sud, Institut Curie, Amiens University Hospital, Poitiers University Hospital, Henri Mondor Hospital, Créteil, Saint Antoine University Hospital, Nord Ardennes Intercommunal Hospital, Centre Antoine Lacassagne, Nice, Hôpital Edouard Herriot (GH Centre), Lyon
- Responsible party
- Sponsor
- Investigators
- Joël GREFFIER, Study chair, Nîmes University Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07305103
- Sponsor's protocol ID
- NIMAO/2024-1/DD-01
- Acronym
- NR Spectral
- Status last verified
- Oct 2026
- First submitted
- 10 Sep 2025
- Last updated
- 21 Oct 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Publications
Henzler T, Fink C, Schoenberg SO, Schoepf UJ. Dual-energy CT: radiation dose aspects. AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S16-25. doi: 10.2214/AJR.12.9210.
PubMed 23097163Ghasemi Shayan R, Oladghaffari M, Sajjadian F, Fazel Ghaziyani M. Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT). Radiol Res Pract. 2020 Apr 20;2020:1403957. doi: 10.1155/2020/1403957. eCollection 2020.
PubMed 32373363Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S. Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging. 2023 Apr;104(4):167-177. doi: 10.1016/j.diii.2022.11.003. Epub 2022 Nov 19.
PubMed 36414506Dabli D, Frandon J, Belaouni A, Akessoul P, Addala T, Berny L, Beregi JP, Greffier J. Optimization of image quality and accuracy of low iodine concentration quantification as function of dose level and reconstruction algorithm for abdominal imaging using dual-source CT: A phantom study. Diagn Interv Imaging. 2022 Jan;103(1):31-40. doi: 10.1016/j.diii.2021.08.004. Epub 2021 Oct 6.
PubMed 34625394Si-Mohamed SA, Boccalini S, Villien M, Yagil Y, Erhard K, Boussel L, Douek PC. First Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype. Invest Radiol. 2023 Jul 1;58(7):459-471. doi: 10.1097/RLI.0000000000000965. Epub 2023 Feb 22.
PubMed 36822663Wortman JR, Shyu JY, Dileo J, Uyeda JW, Sodickson AD. Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality. Emerg Radiol. 2020 Feb;27(1):45-50. doi: 10.1007/s10140-019-01733-9. Epub 2019 Nov 1.
PubMed 31673838Noda Y, Kawai N, Kawamura T, Kobori A, Miyase R, Iwashima K, Kaga T, Miyoshi T, Hyodo F, Kato H, Matsuo M. Radiation and iodine dose reduced thoraco-abdomino-pelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction. Br J Radiol. 2022 Jun 1;95(1134):20211163. doi: 10.1259/bjr.20211163. Epub 2022 Mar 4.
PubMed 35230135Etard C, Bigand E, Salvat C, Vidal V, Beregi JP, Hornbeck A, Greffier J. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France. Eur Radiol. 2017 Oct;27(10):4281-4290. doi: 10.1007/s00330-017-4780-5. Epub 2017 Mar 13.
PubMed 28289939Greffier J, Ferretti G, Rousseau J, Andreani O, Alonso E, Rauch A, Gillet R, Le Roy J, Cabrol-Faivre L, Douane F, David A, Henry S, Jacques T, Stefanovic X, Decoux E, Lafay F, Pilleul F, Couzon F, Boutet C, Woerly B, Baur P, Sans N, Faruch M, Moussier-Lherm A, Tselikas L, Jacquier A, Bigand E, Pessis E, Teriitehau C, Magnier F, Cassagnes L, Haberlay M, Boutteau D, De Kerviler E, Majorel-Gouthain C, Defez D, Vuillod A, Rouviere O, Hennequin L, Fohlen A, Alwan R, Malakhia A, Aubry S, Dohan A, Eresue-Bony M, Gautier R, Dal R, Dabli D, Hebert T, Kovacs R, Hadid-Beurrier L, Bousson V, Potel M, Barbotteau Y, Michel C, Habib-Geryes B, Andre M, Arnaud T, Bestion N, Ernst O, Monfraix S, Brillet PY, Guiu B, Boussel L, Demonchy M, Beregi JP, Frandon J. National dose reference levels in computed tomography-guided interventional procedures-a proposal. Eur Radiol. 2020 Oct;30(10):5690-5701. doi: 10.1007/s00330-020-06903-9. Epub 2020 May 2.
PubMed 32361774
Study at a glance
From the registry record, last updated by the sponsor on 21 Oct 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Defining Dosimetric Reference Levels in Computed Tomography Spectral Scanning
- ClinicalTrials.gov ID
- NCT07305103
- Acronym / sponsor ID
- NR Spectral / NIMAO/2024-1/DD-01
- Conditions
- Medical Imaging
- Keywords
- Radiation dose, Reference levels, Radiology, Spectral Computed Tomography Imaging
- Study type
- Observational
- Recruitment status
- Active, not recruiting
- Enrolment
- 9,600 participants (actual)
- Lead sponsor
- Centre Hospitalier Universitaire de NīmesUniversity, hospital or other
- Collaborators
- Institut Paoli Calmettes, Marseille, Hôpital Necker-Enfants Malades, University Hospital, Lille, Hopital Lariboisière, Centre Hospitalier Universitaire de Saint Etienne, Saint-Louis Hospital, Paris, France, Bichat Hospital, Hôpital Louis Mourier, 92700 Colombes, Centre Hospitalier de Valenciennes, Hopital Louis Pradel, Centre Léon Bérard, Lyon, University Hospital, Bordeaux, Centre Hospitalier Lyon Sud, Institut Curie, Amiens University Hospital, Poitiers University Hospital, Henri Mondor Hospital, Créteil, Saint Antoine University Hospital, Nord Ardennes Intercommunal Hospital, Centre Antoine Lacassagne, Nice, Hôpital Edouard Herriot (GH Centre), Lyon
- Study start
- 1 Sep 2025 (actual)
- Primary completion
- 31 Dec 2026 (estimated)
- Study completion
- 30 Jun 2027 (estimated)
- First posted
- 26 Dec 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Spectral computed tomography or dual-energy CT imaging can overcome the limitations of conventional CT in differentiating between two materials with equivalent total attenuation. It can generate several types of images, such as virtual monochromatic images, which improve the contrast-to-noise ratio for low energy levels and reduce artifacts for high energy levels. It also allows for quantitative image analysis and thus better characterization of lesions and tissues through material mapping (e.g., iodinated contrast agent mapping). This technique is increasingly used in routine clinical practice thanks to improvements in image flow management and technological advances. It also involves exposing patients to ionizing radiation, as with conventional CT but, unlike conventional CT scans, for which dosimetric reference levels (RLs) are defined for the most common examinations in France (RL decree dated 2019), there are currently no dosimetric reference levels for examinations performed using this technique. Yet RLs are an important and effective tools for optimizing patient exposure to ionizing radiation. Several articles were published between 2012 and 2017 when the first dual-energy scanners arrived in clinics. However, the results presented in these studies are now far removed from recent practices, as they do not take into account the latest technological developments used in dual-energy scanners, which reduce X-ray doses.
The main objective of the study is to define dosimetric reference levels for the most commonly performed spectral computed tomography examinations in France.
Detailed description
Spectral computed tomography (CT) (or dual-energy CT) imaging can overcome the limitations of conventional CT in differentiating between two materials with equivalent total attenuation. It can generate several types of images, such as virtual monochromatic images, which improve the contrast-to-noise ratio for low energy levels and reduce artifacts for high energy levels. It also allows for quantitative image analysis and thus better characterization of lesions and tissues through material mapping (e.g., iodinated contrast agent mapping). This technique is increasingly used in routine clinical practice thanks to improvements in image flow management and technological advances. It also involves exposing patients to ionizing radiation, as with conventional CT.
However, unlike conventional CT scans, for which dosimetric reference levels (RLs) are defined for the most common examinations in France (RL decree dated 2019), there are currently no dosimetric reference levels for examinations performed using this technique. Yet the RL is an important and effective tool in optimizing patient exposure to ionizing radiation. In fact, a number of articles were published between 2012 and 2017, when the first dual-energy scanners arrived in clinics. However, the results presented in these studies are now far removed from recent practices, as they do not take into account the latest technological developments used in dual-energy scanners, which reduce X-ray doses.
The main objective of the study is to define dosimetric reference levels for the most frequently performed spectral computed tomography examinations in France:
- Chest CT for pulmonary embolism
- Chest CT for other indications
- Coronary CT with contrast injection and retrospective gating
- Coronary CT with contrast injection and prospective gating
- Cranial CT with contrast injection
- Supra-aortic trunk CT
- Neck and ear,nose and throat sphere CT with contrast injection
- Oncological abdomen-pelvis CT scan
- Abdomen-pelvis CT scan to check for kidney stones
- Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones
- Oncological chest-abdomen-pelvis CT scan
- Non-oncological chest-abdomen-pelvis CT scan
- Oncological chest-abdomen CT scan
- Non-oncological chest-abdomen CT scan
- Lower limb angiography
- Cervical spine CT scan
- Thoracic spine CT scan
- Lumbar spine CT scan
- Pelvis CT scan,
- Extremities CT scan
The secondary objectives of the study are to evaluate, for each examination performed:
- the impact of the spectral acquisition/detection technique on the dose delivered to patients.
- the impact of patients' BMI on the dose delivered to patients.
- the impact of reconstruction algorithms on the dose delivered to patients.
Study design
- Observational model
- Cohort
- Time perspective
- Retrospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below | – | Radiation: Spectral ComputedTomographyPatients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below: 1. Chest CT for pulmonary embolism 2. Chest CT for other indications 3. Coronary CT with contrast injection and retrospective gating 4. Coronary CT with contrast injection and prospective gating 5. Cranial CT with contrast injection 6. Supra-aortic trunk CT 7. Neck and ear,nose and throat sphere CT with contrast injection 8. Oncological abdomen-pelvis CT scan 9. Abdomen-pelvis CT scan to check for kidney stones 10. Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones 11. Oncological chest-abdomen-pelvis CT scan 12. Non-oncological chest-abdomen-pelvis CT scan 13. Oncological chest-abdomen CT scan 14. Non-oncological chest-abdomen CT scan 15. Lower limb angiography 16. Cervical spine CT scan 17. Thoracic spine CT scan 18. Lumbar spine CT scan 19. Pelvis CT scan, 20. Extremities CT scan |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- All adult patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.
Key inclusion criteria (3 listed)
- Adult male/female patient (≥ 18 years old)
- Body Mass Index (BMI) between 18 and 35 kg/m²
- Patients who underwent a spectral CT scan between January 1, 2023, and August 31, 2024, as part of their treatment.
Key exclusion criteria (1 listed)
- Pregnant women
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Spectral ComputedTomographyCommonly performed spectral computed tomography examinations in France | Radiation | Patients undergoing a maximum number of 18 spectral CT scans among the examinations mentioned below |
Primary outcome
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for other indications. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and retrospective gating. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Coronary CT with contrast injection and prospective gating. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Cranial CT with contrast injection. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Supra-aortic trunk CT. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Neck and ear,nose and throat sphere CT with contrast injection. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological abdomen-pelvis CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan to check for kidney stones. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Abdomen-pelvis CT scan for non-oncological purposes and to check for kidney stones. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen-pelvis CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen-pelvis CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Oncological chest-abdomen CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Non-oncological chest-abdomen CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Lower limb angiography. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Cervical spine CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Thoracic spine CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Lumbar spine CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Pelvis CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm
Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. CTDIvol
Time frame: Periprocedural
Computed tomography dose index (CTDIvol) per acquisition expressed in milligray (mGy).
Dosimetric reference levels for spectral computed tomography examinations in France: Extremities CT scan. DLP
Time frame: Periprocedural
Dose length product (DLP) expressed in mGy.cm will be recorded
183 secondary outcomes
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition type
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. Number of acquisitions
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. CTDIvol
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for pulmonary embolism. DLP
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. BMI
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters, kV
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters, mAs
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters. Rotation time
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for pulmonary embolism. Acquisition parameters. Helical pitch
Time frame: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Chest CT for pulmonary embolism. Type of reconstruction algorithm
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. Acquisition type
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. Number of acquisitions
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. CTDIvol
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Chest CT for other indications. DLP
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. BMI
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, kV
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, mAs
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, rotation time
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Chest CT for other indications. Acquisition parameters, helical pitch
Time frame: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Chest CT for other indications. Type of reconstruction algorithm
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. Acquisition type
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. Number of acquisitions
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. CTDIvol
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Coronary CT with contrast injection and retrospective gating. DLP
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. BMI
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Acquisition parameters, kV
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Acquisition parameters, mAs
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Rotation time
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Helical pitch
Time frame: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Coronary CT with contrast injection and retrospective gating. Type of reconstruction algorithm
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. Acquisition type
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. Number of acquisitions
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. CTDIvol
Time frame: Periprocedural
Impact of the spectral acquisition/detection technique on the dose delivered to patients: Cranial CT with contrast injection. DLP
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. BMI
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Acquisition parameters, kV
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Acquisition parameters, mAs
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Rotation time
Time frame: Periprocedural
Impact of patients' BMI on the dose delivered to patients: Cranial CT with contrast injection. Helical pitch
Time frame: Periprocedural
Impact of reconstruction algorithms on the dose delivered to patients : Cranial CT with contrast injection. Type of reconstruction algorithm
Time frame: Periprocedural
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 21 Oct 2026.
- Background: PubMed 23097163Henzler T, Fink C, Schoenberg SO, Schoepf UJ. Dual-energy CT: radiation dose aspects. AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S16-25. doi: 10.2214/AJR.12.9210.
- Background: PubMed 32373363Ghasemi Shayan R, Oladghaffari M, Sajjadian F, Fazel Ghaziyani M. Image Quality and Dose Comparison of Single-Energy CT (SECT) and Dual-Energy CT (DECT). Radiol Res Pract. 2020 Apr 20;2020:1403957. doi: 10.1155/2020/1403957. eCollection 2020.
- Background: PubMed 36414506Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S. Spectral CT imaging: Technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging. 2023 Apr;104(4):167-177. doi: 10.1016/j.diii.2022.11.003. Epub 2022 Nov 19.
- Background: PubMed 34625394Dabli D, Frandon J, Belaouni A, Akessoul P, Addala T, Berny L, Beregi JP, Greffier J. Optimization of image quality and accuracy of low iodine concentration quantification as function of dose level and reconstruction algorithm for abdominal imaging using dual-source CT: A phantom study. Diagn Interv Imaging. 2022 Jan;103(1):31-40. doi: 10.1016/j.diii.2021.08.004. Epub 2021 Oct 6.
- Background: PubMed 36822663Si-Mohamed SA, Boccalini S, Villien M, Yagil Y, Erhard K, Boussel L, Douek PC. First Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype. Invest Radiol. 2023 Jul 1;58(7):459-471. doi: 10.1097/RLI.0000000000000965. Epub 2023 Feb 22.
- Background: PubMed 31673838Wortman JR, Shyu JY, Dileo J, Uyeda JW, Sodickson AD. Dual-energy CT for routine imaging of the abdomen and pelvis: radiation dose and image quality. Emerg Radiol. 2020 Feb;27(1):45-50. doi: 10.1007/s10140-019-01733-9. Epub 2019 Nov 1.
- Background: PubMed 35230135Noda Y, Kawai N, Kawamura T, Kobori A, Miyase R, Iwashima K, Kaga T, Miyoshi T, Hyodo F, Kato H, Matsuo M. Radiation and iodine dose reduced thoraco-abdomino-pelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction. Br J Radiol. 2022 Jun 1;95(1134):20211163. doi: 10.1259/bjr.20211163. Epub 2022 Mar 4.
- Background: PubMed 28289939Etard C, Bigand E, Salvat C, Vidal V, Beregi JP, Hornbeck A, Greffier J. Patient dose in interventional radiology: a multicentre study of the most frequent procedures in France. Eur Radiol. 2017 Oct;27(10):4281-4290. doi: 10.1007/s00330-017-4780-5. Epub 2017 Mar 13.
- Background: PubMed 32361774Greffier J, Ferretti G, Rousseau J, Andreani O, Alonso E, Rauch A, Gillet R, Le Roy J, Cabrol-Faivre L, Douane F, David A, Henry S, Jacques T, Stefanovic X, Decoux E, Lafay F, Pilleul F, Couzon F, Boutet C, Woerly B, Baur P, Sans N, Faruch M, Moussier-Lherm A, Tselikas L, Jacquier A, Bigand E, Pessis E, Teriitehau C, Magnier F, Cassagnes L, Haberlay M, Boutteau D, De Kerviler E, Majorel-Gouthain C, Defez D, Vuillod A, Rouviere O, Hennequin L, Fohlen A, Alwan R, Malakhia A, Aubry S, Dohan A, Eresue-Bony M, Gautier R, Dal R, Dabli D, Hebert T, Kovacs R, Hadid-Beurrier L, Bousson V, Potel M, Barbotteau Y, Michel C, Habib-Geryes B, Andre M, Arnaud T, Bestion N, Ernst O, Monfraix S, Brillet PY, Guiu B, Boussel L, Demonchy M, Beregi JP, Frandon J. National dose reference levels in computed tomography-guided interventional procedures-a proposal. Eur Radiol. 2020 Oct;30(10):5690-5701. doi: 10.1007/s00330-020-06903-9. Epub 2020 May 2.
Related trials for Medical Imaging
Not yet recruiting
Positron Emission Tomography and Organ-Specific Changes in Participants Co-Enrolled in NIH Studies of Plasmodium Vivax Controlled Human Malaria Infection
Healthy Volunteer, Malaria
Enrolling by invitation
Development and Evaluation of Magnetic Resonance Imaging Acquisition and Analysis Methods
Healthy
Not yet recruiting
Cardiac CT Angiography in Acute Stroke Imaging (SCOPE-CT)
Acute Ischemic Stroke and Transient Ischemic Attacks
RecruitingPhase 1
PET Imaging of Phosphodiesterase-4B (PDE4B) in Alcohol Use Disorder
Alcohol Use Disorder
RecruitingPhase 1/2
PET/CT Imaging of Small Cell Lung Cancer Using 89Zr-DFO-SC16.56
Small Cell Lung Cancer, Small Cell Lung Carcinoma
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Joël GREFFIER study chair
Nîmes University Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Medical Imaging, run by Centre Hospitalier Universitaire de Nīmes at 1 site in France.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 21 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Dosimetric reference levels for spectral computed tomography examinations in France: Chest CT for pulmonary embolism. CTDIvol (time frame: Periprocedural). The study lists 38 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07305103, which also lists 9 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Oct 2026.