Coronary Artery DiseaseAIM-FFRNCT07329699
Artificial Intelligence-Driven Medipixel Fractional Flow Reserve Versus Invasive Fractional Flow Reserve-Guided PCI Trial (AIM-FFR Trial)
A study testing MPFFR or Invasive FFR in people with Coronary Artery Disease and Chronic Coronary Syndrome, run by Samsung Medical Center at 23 sites in South Korea.
Trial summary
The AIM-FFR trial is a prospective, multi-center, open-label, randomized controlled, non-inferiority trial. The current trial will evaluate non-inferiority of MPFFR-guided PCI, compared with invasive FFR-guided PCI in patients with coronary artery disease. Read more about this study
- Who is it for?
- Ages 19 years and older
- Conditions the study is for
- Coronary Artery Disease, Chronic Coronary Syndrome, Acute Coronary Syndrome
- What is being tested?
- MPFFR or Invasive FFR
- Type of treatment
- Injection or infusion
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 2,100 participants
- Where
- 23 sitesSouth Korea
- Study dates
- 18 Mar 2026to 31 Dec 2029
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 19 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Subject must be at least 19 years of age
- Eligible for coronary angiography and/or percutaneous coronary intervention.
- Chronic coronary syndrome or acute coronary syndrome (non-culprit vessels only)
- Coronary artery disease in one or more native major epicardial vessels or their branches with reference vessel diameter of at least 2.5mm and with visually assessed coronary stenosis in which the physiological severity of the lesion is questionable (typically 40-90% diameter stenosis).
- Subject who is able to understand risks, benefits and treatment alternatives and sign informed consent voluntarily.
Who cannot join
- Patients unable to provide informed consent
- Patients with known intolerance to aspirin, P2Y12 inhibitors, or components of drug-eluting stents and drug-coated balloons
- Patients with coronary artery bypass grafting
- Patients who have non-cardiac co-morbid conditions with life expectancy <1 year
- Patients with cardiogenic shock or cardiac arrest
- Patients with severe left ventricular systolic dysfunction (ejection fraction <30%)
Show all 15Show fewer
- Patients with severe valvular heart disease requiring open heart surgery
- Pregnant or lactating women
- Angiographic exclusion criteria
- Culprit vessel of patients with ST-elevation myocardial infarction (target lesions in non-culprit vessel can be enrolled)
- Chronic total occlusion (target lesions in vessels without chronic total occlusion can be enrolled)
- Ostial stenosis in left man coronary artery or right coronary artery
- Severe tortuosity of any target vessel
- Severe overlap in the stenosed segment
- Poor image quality precluding identification of vessel contours
Trial locations and contacts
23 sites in 1 country. Contact the study team or a site near you to ask about taking part.
23 sites in 1 country
South Korea23 sites, 23 recruiting
- Recruiting
Inje University Haeundae Paik Hospital
Busan
Dong Ki Kim, MD, PhD, imnpymd@gmail.com
Dong Ki Kim, MD, PhD
- Recruiting
Changwon Fatima Hospital
Changwon
Jae Kwang Lee, MD, PhD, 2707wc@hanmail.net
Jae Kwang Lee, MD, PhD
- Recruiting
Gyeongsang National University Changwon Hospital
Changwon
Jong Hwa Ahn, MD, PhD, jonghwaahn@naver.com
Jong Hwa Ahn, MD, PhD
- Recruiting
Keimyung University Dongsan Hospital
Daegu
Hyuck-Jun Yoon, MD, PhD, hippsons@gmail.com
Hyuck-Jun Yoon, MD, PhD
- Recruiting
Kyungpook National University Hospital
Daegu
Namkyun Kim, MD, PhD, namkyun.kim@knu.ac.kr
Namkyun Kim, MD, PhD
- Recruiting
Chonnam National University Hospital, Chonnam National University Medical School
Gwangju
Young Joon Hong, MD, PhD, hyj200@hanmail.net
Seung Hun Lee, MD, PhD, 82-10-6413-7449, lsh8602@naver.com
- Recruiting
Chung-Ang University Gwangmyeong Hospital
Gwangmyeong
Sang Yeub Lee, MD, PhD, louisahj@gmail.com
Sang Yeub Lee, MD, PhD
- Recruiting
CHA Bundang Medical Center
Gyeonggi-do
Seung Yul Lee, MD, PhD, seungyul79@gmail.com
Seung Yul Lee, MD, PhD
- Recruiting
Wonkwang University Hospital
Iksan
Kyeong Ho Yun, MD, PhD, ards7210@wku.ac.kr
Kyeong Ho Yun, MD, PhD
- Recruiting
Inje University College of Medicine, Ilsan Paik Hospital
Ilsan
Sung Woo Cho, MD, PhD, drswcho@hanmail.net
Sung Woo Cho, MD, PhD
- Recruiting
Gachon University Gil Medical Center
Incheon
Albert Youngwoo Jang, MD, PhD, albert.jang.md@gmail.com
Albert Youngwoo Jang, MD, PhD
- Recruiting
International St. Mary's Hospital
Incheon
Hyung Bok Park, MD, PhD, hyungbok7@gmail.com
Hyung Bok Park, MD, PhD
- Recruiting
Gyeongsang National University Hospital
Jinju
Jin Sin Koh, MD, PhD, kjs0175@gmail.com
Jin Sin Koh, MD, PhD
- Recruiting
Seoul National University Bundang Hospital
Seongnam
Ki-Hyun Jeon, MD, imcardio@gmail.com
Ki-Hyun Jeon, MD
- Recruiting
Korea University Anam Hospital
Seoul, Select State
Jung-Joon Cha, MD, PhD, joonletter@hanmail.net
Jung-Joon Cha, MD, PhD
- Recruiting
Samsung Medical Center
Seoul, 06351
Joo Myung Lee, MD, MPH, PhD, 0234102575, drone80@hanmail.net
Joo Myung Lee, MD, MPH, PhD
- Recruiting
Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine
Seoul
Seung-Jae Lee, MD, PhD, sjjy1028@daum.net
Woochan Kwon, MD, PhD, danced1@naver.com
- Recruiting
Korea University Guro Hospital
Seoul
Dong-Oh Kang, MD, PhD, gelly9@naver.com
Dong-Oh Kang, MD, PhD
- Recruiting
Seoul National University Boramae Medical Center
Seoul
Hyun Sung Joh, MD, PhD, wingx4@naver.com
Hyun Sung Joh, MD, PhD
- Recruiting
Ajou University Hospital
Suwon
Hong-Seok Lim, MD,PhD, hslimmd@hanmail.net
Hong-Seok Lim, MD,PhD
- Recruiting
Uijeongbu ST. Mary's Hospital
Uijeongbu-si
Chan Joon Kim, MD, PhD, godandsci@naver.com
Chan Joon Kim, MD, PhD
- Recruiting
Ulsan University Hospital
Ulsan
Eun-Seok Shin, MD, PhD, sesim1989@gmail.com
Eun-Seok Shin, MD, PhD
- Recruiting
Wonju Severance Christian Hospital
Wŏnju
Sung Gyun Ahn, MD, PhD, sgahn@yonsei.ac.kr
Jung-Hee Lee, MD, PhD
About this study
Official title: Artificial Intelligence-Driven Angiography-Based Fractional Flow Reserve Versus Invasive Fractional Flow Reserve-Guided PCI
The AIM-FFR trial is a prospective, multi-center, open-label, randomized controlled, non-inferiority trial. The current trial will evaluate non-inferiority of MPFFR-guided PCI, compared with invasive FFR-guided PCI in patients with coronary artery disease.
Read the detailed description
Fractional Flow Reserve (FFR) has been established as the gold standard for determining the functional significance of coronary artery stenosis. Current guidelines have classified FFR as a Class IA recommendation for the assessment of intermediate coronary artery lesions. However, FFR remains underused in daily clinical practice, due to requirement for pressure wire use, hyperemia induction, or prolonged procedural time.
To overcome these limitations, angiography-derived computation of FFR have been widely adopted as wire-free alternatives. These technologies enable functional assessment of coronary stenosis without pressure wires, providing a less invasive and more comfortable alternative to wire-based FFR. Multiple modalities have shown reasonable diagnostic accuracy to predict FFR≤0.80. Among them, Quantitative Flow Ratio (QFR)-guided percutaneous coronary intervention (PCI) demonstrated superior clinical outcome than angiography-guided PCI. Based on these results, QFR-guided PCI is supported by class 1B recommendation from European Society of Cardiology guideline. Nevertheless, angiography-derived FFR also has limitations, primarily related to the technical and workflow demands of the process. Computation of angiography-derived FFR typically requires vessel segmentation, correspondence marking, and 3-dimensional reconstruction from angiographic images, which are time-consuming and subject to operator-dependent variability.
Indeed, recent data shows limitations of angiography-based FFR computation. Study by Ninomiya et al. evaluated five different angiography-derived FFR methods (QFR, vFFR from Pie Medical Imaging, caFFR from Rainmed Ltd, 2D-µFR, and 3D-µFR from Pulse Medical Imaging Technology). Although these angiography-derived FFR methods provided higher discrimination than angiographic stenosis severity to discriminate functionally significant stenosis defined by FFR≤0.80 or instantaneous wave-free ratio≤0.89, the AUC ranged from 0.65 to 0.75. Furthermore, recent FAVOR III Europe trial showed that QFR-guided strategy did not meet non-inferiority to FFR-guided strategy in terms of a composite of death, myocardial infarction, and unplanned revascularization at 12 months. These results support invasive FFR-guided strategy is gold standard method.
Recent advances in Artificial Intelligence (AI) have led to development of automated tools for cardiovascular diagnostics, improving both accuracy and workflow efficiency. The AI-driven angiography-based FFR (Medipixel FFR [MPFFR]) has been developed utilizing AI-based fully automated quantitative coronary angiography (AI-QCA). MPFFR utilizes automated frame selection, AI-based contouring, and real-time modeling, allowing for rapid and accurate physiological assessment without manual segmentation. In previous validation study conducted in Korea (599 vessels from 452 patients who underwent clinically indicated FFR measurement from 5 university hospitals in Korea), Mean analysis time of MPFFR was 12.5±1.7 seconds and manual correction was needed in 32 vessels (5.3%). MPFFR showed similar diagnostic performance with QFR (correlation with FFR; MPFFR vs. QFR: R=0.885 vs. R=0.860, P for comparison=0.011; area under curve to predict FFR≤0.80; 0.949 vs. 0.953, P for comparison=0.631). At a median follow-up of 2 years (interquartile range, 1.6 to 2.6 years), patients with MPFFR≤0.80 had higher risk of target vessel failure than those with MPFFR>0.80 (4.5% vs. 0.8%; adjusted HR, 5.94; 95% CI, 1.27-27.91; P=0.024). C-index to predict target vessel failure was comparable between MPFFR and QFR (0.770 vs. 0.753, P for comparison=0.469).
However, whether MPFFR-guided PCI can be used in daily practice still needs to be validated by randomized controlled trial using invasive FFR-guided PCI as reference standard. On this background, the current trial aims to compare clinical outcomes between MPFFR-guided PCI and invasive FFR-guided PCI in patients with coronary artery disease.
- Being tested
- MPFFR or Invasive FFR
- Keywords
- Coronary artery stenosis, Fractional flow reserve, Prognosis
- Medical subject headings
- Coronary Artery Disease, Acute Coronary Syndrome, Coronary Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
MPFFR or Invasive FFRDiagnostic test
Functionally significant stenosis will be defined as MPFFR≤0.80 or FFR≤0.80. For lesions with MPFFR≤0.80 or FFR≤0.80, PCI will be recommended under current guidelines, however, final decision regarding PCI will be at the discretion of operators. In the MPFFR-guided PCI group, on-site MPFFR value will be used in decision making of revascularization. If PCI is not performed for lesions with MPFFR≤0.80 or FFR≤0.80, the specific reasons will be collected in electronic case report form. For lesions with MPFFR>0.80 or FFR>0.80, PCI will be deferred.
| Study group | Role | What they receive |
|---|---|---|
| MPFFR-guided PCI group | Experimental | In patients randomized to artificial intelligence-driven angiography-based fractional flow reserve (MPFFR)-guided PCI group, MPFFR analysis will be performed using MPFFR-1000 version 2.1.0 (Medipixel Inc., Seoul, Korea). Manual correction can be applied when necessary, however, it will be strongly discouraged by the study protocols. Treatment decisions will be made based on site-measured MPFFR value.
Functionally significant stenosis will be defined as MPFFR≤0.80. For lesions with MPFFR≤0.80, PCI will be recommended under current guidelines, however, final decision regarding PCI will be at the discretion of operators. In the MPFFR-guided PCI group, on-site MPFFR value will be used in decision making of revascularization. If PCI is not performed for lesions with MPFFR≤0.80, the specific reasons will be collected in electronic case report form. For lesions with MPFFR>0.80, PCI will be deferred. Receives: Diagnostic Test: MPFFR or Invasive FFR |
| Invasive FFR-guided PCI group | Active comparator | All invasive FFR measurements will be performed after diagnostic coronary angiography according to a standardized protocol as previously described. A pressure-temperature sensor guide wire (Abbott Vascular, Santa Clara, CA, USA) is positioned at the distal segment of the target lesion. To induce maximal hyperemia state, intravenous infusion of adenosine (140μg/kg/min through a peripheral vein) or intracoronary injection of nicorandil (2mg) will be used. In the presence of drift greater than 0.03 FFR unit, pressure wire will be re-equalized and FFR will be measured again.
Functionally significant stenosis will be defined as FFR≤0.80. For lesions with FFR≤0.80, PCI will be recommended under current guidelines, however, final decision regarding PCI will be at the discretion of operators. If PCI is not performed for lesions with FFR≤0.80, the specific reasons will be collected in electronic case report form. For lesions with FFR>0.80, PCI will be deferred. Receives: Diagnostic Test: MPFFR or Invasive FFR |
What is being measured
The primary outcome is the main question the study is designed to answer.
Major adverse cardiac events (MACE)
a composite of death from any causes, non-fatal myocardial infarction [MI], and clinically indicated unplanned revascularization
Measured: 1 year after last patient enrollment
Secondary outcomes (18)
All-cause death
All-cause death (defined by Academic Research Consortium [ARC] II definition)
Measured: 1 year after last patient enrollment
Cardiovascular death
Cardiovascular death (defined by Academic Research Consortium [ARC] II definition)
Measured: 1 year after last patient enrollment
Non-fatal myocardial infarction (MI)
Non-fatal MI (according to the Fourth universal definition of MI)
Measured: 1 year after last patient enrollment
Target vessel-related MI
Target vessel-related MI (Target vessel denotes vessels with initially interrogated by MPFFR or invasive FFR)
Measured: 1 year after last patient enrollment
Non-target vessel-related MI
Non-target vessel-related MI (Target vessel denotes vessels with initially interrogated by MPFFR or invasive FFR)
Measured: 1 year after last patient enrollment
Clinically indicated unplanned revascularization
Clinically indicated unplanned revascularization (defined by Academic Research Consortium [ARC] II definition)
Measured: 1 year after last patient enrollment
Clinically indicated target vessel revascularization
Clinically indicated target vessel revascularization (Target vessel denotes vessels with initially interrogated by MPFFR or invasive FFR)
Measured: 1 year after last patient enrollment
Clinically indicated non-target vessel repeat revascularization
Clinically indicated non-target vessel repeat revascularization (Target vessel denotes vessels with initially interrogated by MPFFR or invasive FFR)
Measured: 1 year after last patient enrollment
Vessel or Stent thrombosis
Vessel or Stent thrombosis (definite thrombosis defined by Academic Research Consortium [ARC] II definition)
Measured: 1 year after last patient enrollment
Cardiovascular death or target vessel-related MI
A composite of Cardiovascular death or target vessel-related MI
Measured: 1 year after last patient enrollment
Target vessel failure
Target vessel failure (TVF, a composite of cardiovascular death, target vessel-related MI, and clinically indicated target vessel revascularization)
Measured: 1 year after last patient enrollment
Bleeding according to BARC definition
Bleeding according to BARC definition
Measured: 1 year after last patient enrollment
Cerebrovascular accident (CVA)
Cerebrovascular accident (CVA) including ischemic stroke, hemorrhagic stroke, or transient ischemic attack (TIA)
Measured: 1 year after last patient enrollment
Contrast volume (including both diagnostic angiography and PCI)
Contrast volume (including both diagnostic angiography and PCI)
Measured: immediately after the intervention/procedure
Procedure time of MPFFR or invasive FFR measurement
Procedure time of MPFFR or invasive FFR measurement
Measured: immediately after the intervention/procedure
Procedure time including the decision-making time for PCI following coronary angiography
Procedure time including the decision-making time for PCI following coronary angiography
Measured: immediately after the intervention/procedure
Number of lesions interrogated
Number of lesions interrogated by MPFFR or invasive FFR
Measured: immediately after the intervention/procedure
Number of used stents or drug-coated balloons
Number of used stents or drug-coated balloons
Measured: immediately after the intervention/procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Jan 2026
- Study start18 Mar 2026
- Primary completion31 Dec 2028 (estimated)
- Study completion31 Dec 2029 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Coronary Artery DiseaseStudies of the same condition, open and under way.
- More trials run by Samsung Medical CenterThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- A prospective, multi-center, open-label, randomized controlled, non-inferiority trial.
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 2,100 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Samsung Medical Center
- Sponsor type
- University, hospital or other
- Collaborators
- Chonnam National University Hospital, Seoul National University Bundang Hospital, Chung-Ang University Gwangmyeong Hospital, The Catholic University of Korea, Keimyung University Dongsan Medical Center, Wonju Severance Christian Hospital, SMG-SNU Boramae Medical Center, Kangbuk Samsung Hospital, Sungkyunkwan University, Korea University Guro Hospital, Inje University Ilsan Paik Hospital, International St. Mary's Hospital, Kyungpook National University Hospital, Korea University Anam Hospital, Ajou University School of Medicine, Changwon Patima Hospital, Bundang CHA Hospital, Ulsan University Hospital, Gachon University Gil Medical Center, Inje University Haeundae Paik Hospital, Gyeongsang National University Changwon Hospital, Wonkwang University Hospital
- Responsible party
- Principal investigator, Joo Myung Lee, Samsung Medical Center
- Investigators
- Joo Myung Lee, MD, MPH, PhD, Principal investigator, Samsung Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07329699
- Sponsor's protocol ID
- SMC19810222
- Acronym
- AIM-FFR
- Status last verified
- Apr 2026
- First submitted
- 23 Dec 2025
- Last updated
- 23 Apr 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: Reseanable request will be reviwed by the Executive Committee.
Study at a glance
From the registry record, last updated by the sponsor on 23 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Artificial Intelligence-Driven Angiography-Based Fractional Flow Reserve Versus Invasive Fractional Flow Reserve-Guided PCI
- ClinicalTrials.gov ID
- NCT07329699
- Acronym / sponsor ID
- AIM-FFR / SMC19810222
- Keywords
- Coronary artery stenosis, Fractional flow reserve, Prognosis
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 2,100 participants (estimated)
- Lead sponsor
- Samsung Medical CenterUniversity, hospital or other
- Collaborators
- Chonnam National University Hospital, Seoul National University Bundang Hospital, Chung-Ang University Gwangmyeong Hospital, The Catholic University of Korea, Keimyung University Dongsan Medical Center, Wonju Severance Christian Hospital, SMG-SNU Boramae Medical Center, Kangbuk Samsung Hospital, Sungkyunkwan University, Korea University Guro Hospital, Inje University Ilsan Paik Hospital, International St. Mary's Hospital, Kyungpook National University Hospital, Korea University Anam Hospital, Ajou University School of Medicine, Changwon Patima Hospital, Bundang CHA Hospital, Ulsan University Hospital, Gachon University Gil Medical Center, Inje University Haeundae Paik Hospital, Gyeongsang National University Changwon Hospital, Wonkwang University Hospital
- Study start
- 18 Mar 2026 (actual)
- Primary completion
- 31 Dec 2028 (estimated)
- Study completion
- 31 Dec 2029 (estimated)
- First posted
- 9 Jan 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The AIM-FFR trial is a prospective, multi-center, open-label, randomized controlled, non-inferiority trial. The current trial will evaluate non-inferiority of MPFFR-guided PCI, compared with invasive FFR-guided PCI in patients with coronary artery disease.
Detailed description
Fractional Flow Reserve (FFR) has been established as the gold standard for determining the functional significance of coronary artery stenosis. Current guidelines have classified FFR as a Class IA recommendation for the assessment of intermediate coronary artery lesions. However, FFR remains underused in daily clinical practice, due to requirement for pressure wire use, hyperemia induction, or prolonged procedural time.
To overcome these limitations, angiography-derived computation of FFR have been widely adopted as wire-free alternatives. These technologies enable functional assessment of coronary stenosis without pressure wires, providing a less invasive and more comfortable alternative to wire-based FFR. Multiple modalities have shown reasonable diagnostic accuracy to predict FFR≤0.80. Among them, Quantitative Flow Ratio (QFR)-guided percutaneous coronary intervention (PCI) demonstrated superior clinical outcome than angiography-guided PCI. Based on these results, QFR-guided PCI is supported by class 1B recommendation from European Society of Cardiology guideline. Nevertheless, angiography-derived FFR also has limitations, primarily related to the technical and workflow demands of the process. Computation of angiography-derived FFR typically requires vessel segmentation, correspondence marking, and 3-dimensional reconstruction from angiographic images, which are time-consuming and subject to operator-dependent variability.
Indeed, recent data shows limitations of angiography-based FFR computation. Study by Ninomiya et al. evaluated five different angiography-derived FFR methods (QFR, vFFR from Pie Medical Imaging, caFFR from Rainmed Ltd, 2D-µFR, and 3D-µFR from Pulse Medical Imaging Technology). Although these angiography-derived FFR methods provided higher discrimination than angiographic stenosis severity to discriminate functionally significant stenosis defined by FFR≤0.80 or instantaneous wave-free ratio≤0.89, the AUC ranged from 0.65 to 0.75. Furthermore, recent FAVOR III Europe trial showed that QFR-guided strategy did not meet non-inferiority to FFR-guided strategy in terms of a composite of death, myocardial infarction, and unplanned revascularization at 12 months. These results support invasive FFR-guided strategy is gold standard method.
Recent advances in Artificial Intelligence (AI) have led to development of automated tools for cardiovascular diagnostics, improving both accuracy and workflow efficiency. The AI-driven angiography-based FFR (Medipixel FFR [MPFFR]) has been developed utilizing AI-based fully automated quantitative coronary angiography (AI-QCA). MPFFR utilizes automated frame selection, AI-based contouring, and real-time modeling, allowing for rapid and accurate physiological assessment without manual segmentation. In previous validation study conducted in Korea (599 vessels from 452 patients who underwent clinically indicated FFR measurement from 5 university hospitals in Korea), Mean analysis time of MPFFR was 12.5±1.7 seconds and manual correction was needed in 32 vessels (5.3%). MPFFR showed similar diagnostic performance with QFR (correlation with FFR; MPFFR vs. QFR: R=0.885 vs. R=0.860, P for comparison=0.011; area under curve to predict FFR≤0.80; 0.949 vs. 0.953, P for comparison=0.631). At a median follow-up of 2 years (interquartile range, 1.6 to 2.6 years), patients with MPFFR≤0.80 had higher risk of target vessel failure than those with MPFFR>0.80 (4.5% vs. 0.8%; adjusted HR, 5.94; 95% CI, 1.27-27.91; P=0.024). C-index to predict target vessel failure was comparable between MPFFR and QFR (0.770 vs. 0.753, P for comparison=0.469).
However, whether MPFFR-guided PCI can be used in daily practice still needs to be validated by randomized controlled trial using invasive FFR-guided PCI as reference standard. On this background, the current trial aims to compare clinical outcomes between MPFFR-guided PCI and invasive FFR-guided PCI in patients with coronary artery disease.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 2
- Model description
- A prospective, multi-center, open-label, randomized controlled, non-inferiority trial.
| Arm | Type | Receives |
|---|---|---|
| MPFFR-guided PCI group | Experimental | Diagnostic Test: MPFFR or Invasive FFRIn patients randomized to artificial intelligence-driven angiography-based fractional flow reserve (MPFFR)-guided PCI group, MPFFR analysis will be performed using MPFFR-1000 version 2.1.0 (Medipixel Inc., Seoul, Korea). Manual correction can be applied when necessary, however, it will be strongly discouraged by the study protocols. Treatment decisions will be made based on site-measured MPFFR value. Functionally significant stenosis will be defined as MPFFR≤0.80. For lesions with MPFFR≤0.80, PCI will be recommended under current guidelines, however, final decision regarding PCI will be at the discretion of operators. In the MPFFR-guided PCI group, on-site MPFFR value will be used in decision making of revascularization. If PCI is not performed for lesions with MPFFR≤0.80, the specific reasons will be collected in electronic case report form. For lesions with MPFFR>0.80, PCI will be deferred. |
| Invasive FFR-guided PCI group | Active comparator | Diagnostic Test: MPFFR or Invasive FFRAll invasive FFR measurements will be performed after diagnostic coronary angiography according to a standardized protocol as previously described. A pressure-temperature sensor guide wire (Abbott Vascular, Santa Clara, CA, USA) is positioned at the distal segment of the target lesion. To induce maximal hyperemia state, intravenous infusion of adenosine (140μg/kg/min through a peripheral vein) or intracoronary injection of nicorandil (2mg) will be used. In the presence of drift greater than 0.03 FFR unit, pressure wire will be re-equalized and FFR will be measured again. Functionally significant stenosis will be defined as FFR≤0.80. For lesions with FFR≤0.80, PCI will be recommended under current guidelines, however, final decision regarding PCI will be at the discretion of operators. If PCI is not performed for lesions with FFR≤0.80, the specific reasons will be collected in electronic case report form. For lesions with FFR>0.80, PCI will be deferred. |
Who may qualify
- Ages
- 19 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Subject must be at least 19 years of age
- Eligible for coronary angiography and/or percutaneous coronary intervention.
- Chronic coronary syndrome or acute coronary syndrome (non-culprit vessels only)
- Coronary artery disease in one or more native major epicardial vessels or their branches with reference vessel diameter of at least 2.5mm and with visually assessed coronary stenosis in which the physiological severity of the lesion is questionable (typically 40-90% diameter stenosis).
- Subject who is able to understand risks, benefits and treatment alternatives and sign informed consent voluntarily.
Key exclusion criteria (15 listed)
- Patients unable to provide informed consent
- Patients with known intolerance to aspirin, P2Y12 inhibitors, or components of drug-eluting stents and drug-coated balloons
- Patients with coronary artery bypass grafting
- Patients who have non-cardiac co-morbid conditions with life expectancy <1 year
- Patients with cardiogenic shock or cardiac arrest
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| MPFFR or Invasive FFRFunctionally significant stenosis will be defined as MPFFR≤0.80 or FFR≤0.80. For lesions with MPFFR≤0.80 or FFR≤0.80, PCI will be recommended under current guidelines, however, final decision regarding PCI will be at the discretion of operators. In the MPFFR-guided PCI group, on-site MPFFR value will be used in decision making of revascularization. If PCI is not performed for lesions with MPFFR≤0.80 or FFR≤0.80, the specific reasons will be collected in electronic case report form. For lesions with MPFFR>0.80 or FFR>0.80, PCI will be deferred. | Diagnostic test | Invasive FFR-guided PCI group, MPFFR-guided PCI group |
Primary outcome
Major adverse cardiac events (MACE)
Time frame: 1 year after last patient enrollment
a composite of death from any causes, non-fatal myocardial infarction [MI], and clinically indicated unplanned revascularization
18 secondary outcomes
All-cause death
Time frame: 1 year after last patient enrollment
Cardiovascular death
Time frame: 1 year after last patient enrollment
Non-fatal myocardial infarction (MI)
Time frame: 1 year after last patient enrollment
Target vessel-related MI
Time frame: 1 year after last patient enrollment
Non-target vessel-related MI
Time frame: 1 year after last patient enrollment
Clinically indicated unplanned revascularization
Time frame: 1 year after last patient enrollment
Clinically indicated target vessel revascularization
Time frame: 1 year after last patient enrollment
Clinically indicated non-target vessel repeat revascularization
Time frame: 1 year after last patient enrollment
Vessel or Stent thrombosis
Time frame: 1 year after last patient enrollment
Cardiovascular death or target vessel-related MI
Time frame: 1 year after last patient enrollment
Target vessel failure
Time frame: 1 year after last patient enrollment
Bleeding according to BARC definition
Time frame: 1 year after last patient enrollment
Cerebrovascular accident (CVA)
Time frame: 1 year after last patient enrollment
Contrast volume (including both diagnostic angiography and PCI)
Time frame: immediately after the intervention/procedure
Procedure time of MPFFR or invasive FFR measurement
Time frame: immediately after the intervention/procedure
Procedure time including the decision-making time for PCI following coronary angiography
Time frame: immediately after the intervention/procedure
Number of lesions interrogated
Time frame: immediately after the intervention/procedure
Number of used stents or drug-coated balloons
Time frame: immediately after the intervention/procedure
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 23 Apr 2026.
- Individual participant dataSharing planned: Yes. Reseanable request will be reviwed by the Executive Committee.
Related trials for Coronary Artery Disease
RecruitingPhase 4
Efficacy and Safety of a Half-dose Bolus of r-SAK Prior to Primary PCI in ST-elevation Myocardial Infarction
ST Elevation Myocardial Infarction
Active, not recruitingPhase 4
Women's IschemiA TRial to Reduce Events In Non-ObstRuctive CAD
Coronary Artery Disease
RecruitingPhase 4
CCTA Evaluation of SGLT2i-related Pericoronary Fat Changes Patients With Stage 4 CKM Syndrome
ACS (Acute Coronary Syndrome), SGLT2 Inhibitors
Not yet recruiting
Effect of Propionic Acid Supplementation on Endothelial Function
Cardiovascular Diseases, Endothelial Dysfunction
Recruiting
Intracoronary Cryotherapy Effect on Stabilization of Vulnerable Plaque in Patients With Stable Angina or ACS - A Traditional Feasibility Study
Coronary Arterial Disease (CAD), Plaque
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Joo Myung Lee, MD, MPH, PhD principal investigator
Samsung Medical Center
23 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing MPFFR or Invasive FFR in people with Coronary Artery Disease and Chronic Coronary Syndrome, run by Samsung Medical Center at 23 sites in South Korea.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 15 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 23 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 23 sites in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Joo Myung Lee, MD, MPH, PhD (0234102575, drone80@hanmail.net), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Major adverse cardiac events (MACE) (time frame: 1 year after last patient enrollment). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Apr 2026.