AzTrials
AzTrials

We Evaluated CT-guided Localization of the Right Phrenic Nerve to Enhance Safety in Transcatheter AblationNCT07330791

Right Phrenic Nerve Localization on CT for Ablation

An observational study of We Evaluated CT-guided Localization of the Right Phrenic Nerve to Enhance Safety in Transcatheter Ablation, run by Centro Medico Teknon at 1 site in Spain.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The anatomical location of the right phrenic nerve (RPN) in close proximity to the right pulmonary veins has become a critical consideration for electrophysiologists performing pulmonary vein isolation, the cornerstone treatment for atrial fibrillation. Read more about this study

Who is it for?
Ages 18 years and older
How many people
80 participants
Where
1 siteSpain
Study dates
1 Apr 2025to 29 Sep 2025
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: All patients underwent an electrocardiography-gated cardiovascular CT using a 64-slice multidetector row CT scanner (Revolution CT, GE Healthcare Global Diagnostic Imaging) prior to the ablation procedure. The position line was set at 0.5 cm below the tracheal bifurcation to the cardiac diaphragmatic surface. The acquisition was performed within a single breath- hold. The gantry rotation time was 0.35 s, and the tube current was 350-750 mA at 120 kV. Iodinated contrast material (60 mL; Omnipaque 300 mg/mL), was injected at a rate of 4-5 mL/s, followed by 20 mL of saline solution. A second acquisition immediately after is performed to study the venous phase. Original images at 75% or 45% R-R intervals were transferred to post-processing Workstation, with a section thickness of 0.625 mm. If motion artifacts appeared, the electrocardiographic editing technique was used and the reconstructed window was moved forward or backward for 5% R-R interval until the motion artifacts disappeared.

Who may be able to join

  • Ability to provide informed consent
  • Patients who have undergone or will undergo transcatheter AF ablation or CNA
  • Availability of 64-slice contrast-enhanced MDCT with RPN segmentation using ADAS® software prior to ablation
  • Age ≥ 18 years

Who cannot join

  • Inability to provide informed consent
  • Inability to perform contrast-enhanced CT before transcatheter AF ablation or CNA
  • Age < 18 years

Trial locations and contacts

1 site in 1 country.

Spain1 site
  • Antonio Berruezo

    Barcelona, Barcelona, 08022

Other trials in Spain

About this study

Official title: Right Phrenic Nerve Localization Using CT Scanning: Implications for Radiofrequency Ablation Procedures

The anatomical location of the right phrenic nerve (RPN) in close proximity to the right pulmonary veins has become a critical consideration for electrophysiologists performing pulmonary vein isolation, the cornerstone treatment for atrial fibrillation. Although radiofrequency ablation in this region is rarely associated with complications-unlike cryoballoon ablation-the proximity of the RPN to the ablation site is considered the most widely accepted mechanism of nerve injury. Therefore, accurately defining its anatomical course is essential to prevent complications.

This concern extends to any ablation procedure performed near the RPN, including those targeting the lateral-posterior region of the right atrium, particularly during atrial tachycardia ablation or cardioneuroablation. Several methods have been used to precisely localize the RPN. The most commonly employed technique is phrenic nerve stimulation; however, there is growing interest in the use of computed tomography (CT) to identify structures running parallel to the nerve-such as the pericardiophrenic artery and vein-enhanced with contrast. Three-dimensional reconstruction through image segmentation has proven useful in defining the anatomy of cardiac chambers and adjacent extracardiac structures.

This study aims to compare two approaches for visualizing the course of the right phrenic nerve: one based on computed tomography imaging and the other on the nerve's response to stimulation during the procedure. This comparison will allow us to assess the concordance between imaging findings and intra-procedural observations, ultimately contributing to improved procedural safety.

Keywords
Right Phrenic Nerve, Phrenic Nerve Localization, Computed Tomography, CT-Guided Imaging, Radiofrequency Ablation, Catheter Ablation, Transcatheter Ablation Safety, Cardiac Ablation Complications, Ablation Procedures, Phrenic Nerve Injury

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

Study groups in NCT07330791
Study groupRoleWhat they receive
This study will enroll patients undergoing two distinct types of ablative procedures gA total of 80 consecutive patients will be included: * 60 patients will be enrolled using a single electric stimulation output set at 20 mA, 2 ms amplitude width and 1000 ms cycle length * 20 patients will be enrolled using a double electric stimulation output set respectively at 10 mA and 20 mA (2 ms amplitude width and 1000 ms cycle length)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. analyse the anatomy of the RPN

    The primary endpoint of this study is to analyse the anatomy of the RPN using three-dimensional (3D) imaging and iso-distance mapping with ADAS® software, and to validate its accuracy through traditional pace mapping.

    Measured: From January 2021 to April 2025

  2. Accuracy of Imaging-Guided Anatomical Localization of the Phrenic Nerve with ADAS® software Compared With Conventional Pacemapping

    The positions as observed by the 2 different methods are compared and the correlation was expressed as a percentage. Global image correlation is computed as the mean correlation between methods.

    Measured: from the procedure to 12 months later

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Jan 2026
  2. Study start1 Apr 2025
  3. Primary completion20 Sep 2025
  4. Study completion29 Sep 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
80 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07330791
Sponsor's protocol ID
Phrenic nerve CT-Localization
Status last verified
Sep 2025
First submitted
10 Dec 2025
Last updated
9 Jan 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Questions about this trial

What is this clinical trial studying?

An observational study of We Evaluated CT-guided Localization of the Right Phrenic Nerve to Enhance Safety in Transcatheter Ablation, run by Centro Medico Teknon at 1 site in Spain.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 9 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

analyse the anatomy of the RPN (time frame: From January 2021 to April 2025). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Jan 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in