CataractVIVITY-KCONUSNCT07338708
Visual Outcomes and Quality of Life After Vivity EDOF IOL Implantation in Early-Stage Keratoconus
A study testing Extended Depth of Focus Intraocular Lens Implantation in people with Cataract and Keratoconic Subjects, run by Azienda Ospedaliera Universitaria Integrata Verona at 1 site in Italy.
Trial summary
The goal of this clinical trial is to learn if the Vivity Extended Depth of Focus intraocular lens works to improve vision in adults with cataracts and early-stage keratoconus. It will also learn about the safety and tolerance of this premium lens in patients with mild corneal irregularities. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Cataract, Keratoconic Subjects
- What is being tested?
- Extended Depth of Focus Intraocular Lens Implantation
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteItaly
- Study dates
- 17 Sep 2024to 13 May 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adults requiring bilateral cataract surgery
- Mild bilateral keratoconus defined as stage 0-1 according to the ABCD classification system
- Keratoconus stability defined as maximum keratometry (K) changes less than 1 diopter and maximum pachymetry reduction less than 2% within the previous 5 years
- Pre-cataract spectacle distance-corrected visual acuity of 0.1 to 0.0 LogMAR (Snellen 20/25 to 20/20)
- Agreement to bilateral implantation of AcrySof IQ Vivity Extended Depth of Focus intraocular lens
- Willingness to undergo second-eye surgery within 7 days after first-eye procedure
- Ability and willingness to attend all scheduled follow-up visits as per study protocol
- Provision of written informed consent to participate in the study
Who cannot join
- Any ocular comorbidities other than cataract and keratoconus, or history of any disease that could affect visual results (e.g., glaucoma, retinal disorders)
- Corneal opacity including any corneal scarring
- Advanced or progressive keratoconus
- Any previous ocular surgery other than corneal cross-linking performed at least 5 years prior to enrollment
- Corneal cross-linking performed within 5 years prior to enrollment
- Amblyopia
- Pseudoexfoliation syndrome or zonular laxity
- History of uveitis
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Assessment of Tolerance and Visual Outcomes After Bilateral Implantation of a Premium Type Intraocular Lens (Acrysof IQ Vivity IOL) in Patients With Cataract and Mild Keratoconus
The goal of this clinical trial is to learn if the Vivity Extended Depth of Focus intraocular lens works to improve vision in adults with cataracts and early-stage keratoconus. It will also learn about the safety and tolerance of this premium lens in patients with mild corneal irregularities. The main questions it aims to answer are:
- Does the Vivity EDOF lens provide good distance vision (20/25 or better) in the dominant eye at 3 months after surgery?
- Does it improve vision at intermediate and near distances compared to before surgery?
- Does it preserve contrast sensitivity and optical quality despite mild corneal irregularities?
- What is the patient-reported quality of life and satisfaction after implantation?
- What visual disturbances (such as halos) do participants experience?
Read more
All participants will:
- Receive the Vivity EDOF intraocular lens (or its toric version if astigmatism is present) in both eyes during standard cataract surgery, with the second eye operated within 7 days;
- Undergo comprehensive eye examinations before surgery including vision testing, corneal imaging, and optical quality measurements;
- Attend a follow-up visit at 3 months after surgery for detailed vision testing at multiple distances, contrast sensitivity testing under different lighting conditions, halo assessment, and quality-of-life questionnaires.
Read the detailed description
Background and Rationale Keratoconus (KC) is a progressive, non-inflammatory corneal ectasia characterized by stromal thinning and irregular astigmatism, often resulting in significant higher-order aberrations (HOAs) that impair visual quality. Due to these optical limitations, the use of premium intraocular lenses (pIOLs) has traditionally been considered contraindicated in these patients. However, in patients with early-stage keratoconus, corneal shape and optical quality can be relatively well preserved, with HOAs remaining within acceptable limits. These patients may thus benefit from carefully selected premium IOL technologies.
Extended-depth-of-focus (EDOF) IOLs, in contrast to traditional multifocal lenses, not only provide significantly fewer visual disturbances but, thanks to their elongated focus, they could mitigate HOAs and coma-like distortions characteristic of early keratoconus. Unlike monofocal or multifocal lenses, which rely on a single, sharp focal point or discrete focal planes, EDOF lenses are inherently designed to maintain functional retinal image quality across an extended focal range, offering greater tolerance to minor defocus and wavefront aberrations. While EDOF lenses do not correct such aberrations, their extended focal range may reduce the impact of this distortion on functional vision. This is especially true for non-diffractive EDOF lenses, which preserve high levels of contrast sensitivity by not splitting light energy into multiple focal points.
The AcrySof IQ Vivity IOL (Alcon, Fort Worth, TX, USA) is a non-diffractive EDOF IOL that uses wavefront-shaping technology to elongate the focal range. Previous studies have already demonstrated good outcomes in patients with other challenging ocular conditions such as glaucoma, macular degeneration, and epiretinal membrane. The present pilot study aims to evaluate the visual performance, tolerance, and optical quality outcomes following implantation of the Vivity IOL in patients with cataract and stable, early-stage keratoconus. This investigation explores the clinical viability of premium IOLs in a population traditionally excluded from such refractive options.
Study Design This is a prospective, interventional, single-center pilot study conducted in Italy. The study has been approved by the local ethics committee (protocol number 22546) and adheres to the principles of the Declaration of Helsinki. A total of 10 patients (20 eyes) with cataracts and mild bilateral keratoconus will be enrolled and followed for 3 months after bilateral implantation of the AcrySof IQ Vivity EDOF IOL.
Study Objectives
Primary Objective:
- To evaluate monocular distance-corrected visual acuity (DCVA) in the dominant eye at 3 months after surgery.
Secondary Objectives:
- To assess monocular and binocular uncorrected and distance-corrected visual acuity at distance (4 meters), intermediate (66 cm), and near (40 cm)
- To evaluate binocular defocus curves from +1.50 D to -3.50 D in 0.50 D increments;
- To measure monocular and binocular contrast sensitivity under photopic (80 cd/m²), mesopic (6 cd/m²), and scotopic (3 cd/m²) lighting conditions;
- To assess ocular optical quality including root mean square (RMS) wavefront error and point spread function (PSF) Strehl ratio at 3 mm and 4 mm pupil diameters;
- To evaluate binocular halo perception using standardized halometry;
- To assess patient-reported quality of life using the National Eye Institute Refractive Error Quality of Life Instrument-42 (NEI-RQL-42) questionnaire;
- To evaluate the safety profile including intra- and postoperative complications and adverse events;
- To assess toric IOL rotational stability in eyes receiving the toric version.
Eligibility criteria such as inclusion and exclusion criteria are reported separately.
Preoperative Assessment:
All patients will receive a comprehensive ophthalmologic evaluation prior to surgery, including:
- Measurement of monocular and binocular uncorrected and corrected visual acuity for distance (4 meters) and near (40 cm) using CSO Vision Charts software version 14.0
- Corneal tomography using MS-39 anterior segment optical coherence tomography (CSO, Florence, Italy)
- Ocular optical quality analysis using Pyramidal WaveFront-based sensor aberrometer (Osiris T Aberrometer, CSO, Florence, Italy) to assess higher-order aberrations including coma and coma-like aberrations
- Optical biometry using Lenstar 900 (Haag-Streit Diagnostics, Koeniz, Switzerland) for axial length and IOL power calculation
- Intraocular pressure measurement
- Slit-lamp examination of the anterior segment
- Dilated fundoscopy
- Macular evaluation through spectral-domain optical coherence tomography (Spectralis OCT, Heidelberg Engineering GmbH, Germany)
- Ocular dominance determination using the Miles test
Surgical Procedure:
All patients will undergo standard phacoemulsification cataract surgery performed by the same experienced surgeon using a 2.2 mm phaco probe under topical anesthesia. The AcrySof IQ Vivity EDOF IOL will be implanted in the capsular bag with a target of emmetropia bilaterally. IOL power calculation will be performed using the Kane formula. In eyes with regular corneal astigmatism equal to or greater than 1.00 diopter, the toric version of the Vivity IOL (AcrySof IQ Vivity Toric) will be implanted to optimize postoperative refractive outcomes. The second eye will be operated within 7 days of the first eye surgery.
Postoperative Follow-up:
Toric IOL rotational stability will be assessed on postoperative days 1 and 7 to account for early positional shifts and to allow for re-centering if necessary. The IOL will be deemed stable if the angular deviation is less than 5 degrees and if it induces a residual cylindrical error of 0.75 diopters or less, as estimated using the Toric IOL Assistant feature of the Osiris T Aberrometer.
Complete ophthalmological examination will be performed at the 3-month follow-up visit and outcome measures are measured as explained in the outcome measures section.
The Vivity IOL Technology The AcrySof IQ Vivity is a single-piece, hydrophobic acrylic EDOF IOL that utilizes a non-diffractive wavefront-shaping mechanism to enhance intermediate and near vision. The optic is 6.0 mm in diameter with an overall length of 13.0 mm and features a C-loop haptic design. The lens material incorporates both ultraviolet and blue light-filtering chromophores and has a refractive index of 1.55 at 35°C.
The lens design is based on a monofocal aspheric platform with an aberration-neutral anterior surface. The central optical zone incorporates X-WAVE technology, which integrates two subtle anterior surface transition elements: a slightly elevated central plateau (approximately 1 micrometer) that stretches the wavefront to extend the focus, and a surrounding curvature modulation that shifts the wavefront, ensuring efficient retinal energy delivery across the extended range.
The spherical model is available in powers ranging from +15.0 diopters to +25.0 diopters in 0.5 diopter increments, with additional availability up to +30.0 diopters in selected markets. The toric version, AcrySof IQ Vivity Toric, incorporates the same non-diffractive EDOF design and is offered in cylinder powers from 1.03 diopters to 4.11 diopters at the IOL plane.
Statistical Analysis All statistical analyses will be performed using STATA software, version 13.0 (StataCorp, College Station, TX, USA). The distribution of continuous variables will be assessed with the Shapiro-Wilk test. When data are normally distributed, results will be reported as mean ± standard deviation.
To evaluate the safety profile of the implanted IOL, both absolute and relative frequencies of intra- and postoperative complications, as well as any adverse events, will be recorded and analyzed at each follow-up. Paired t-tests will be conducted between preoperative and postoperative DCVA, DCNVA, UDVA, UNVA, and total RMS to assess postoperative functional improvement.
The primary endpoint is the evaluation of DCVA in the dominant eye at 3 months. A formal sample-size calculation was performed based on a previous pilot series reporting a standard deviation of 0.01 logMAR for monocular DCVA in eyes with stable keratoconus and cataract implanted with a premium IOL. A single-group design was used to estimate a 95% confidence interval for one standard deviation via the chi-square method. Assuming a standard deviation of 0.017 logMAR, 10 subjects (10 eyes) are required to yield a confidence interval half-width no greater than 0.02 logMAR (equivalent to one ETDRS letter). Sample-size calculations were carried out with PASS 2023, version 23.0.2.
Safety Considerations All participants will be carefully monitored for any adverse events or complications related to the surgical procedure or the implanted IOL. Standard cataract surgery risks include infection (endophthalmitis), inflammation, bleeding, increased intraocular pressure, lens dislocation, posterior capsule rupture, cystoid macular edema, and retinal detachment. Additional considerations specific to premium IOLs include the potential for visual disturbances such as glare, halos, starbursts, reduced contrast sensitivity, and in rare cases, dissatisfaction requiring IOL exchange.
In the specific context of keratoconus patients, there is theoretical concern that residual corneal irregularities and higher-order aberrations might interact with the IOL optics in unpredictable ways, potentially limiting visual quality or increasing photic phenomena. However, by carefully selecting only patients with early-stage, stable keratoconus and relatively preserved corneal morphology, this study aims to minimize these risks while exploring the potential benefits of EDOF technology in this population.
Any serious adverse events will be immediately reported to the ethics committee and appropriate medical management will be provided. Participants are free to withdraw from the study at any time without affecting their medical care.
Expected Outcomes and Significance This pilot study will provide preliminary evidence regarding the safety, efficacy, and patient satisfaction associated with Vivity EDOF IOL implantation in patients with early-stage keratoconus. If successful, the results may challenge the traditional view that premium IOLs are contraindicated in keratoconus and open new treatment options for carefully selected patients who wish to reduce spectacle dependence after cataract surgery.
The non-diffractive EDOF design of the Vivity lens, with its extended focal range and preserved contrast sensitivity, may be particularly well-suited to tolerating the mild corneal irregularities present in early keratoconus. By extending the depth of focus rather than creating discrete focal points, the lens may maintain functional vision despite minor wavefront aberrations.
Results from this study will inform larger, multicenter, randomized controlled trials and may ultimately contribute to updated clinical guidelines for IOL selection in keratoconus patients
- Conditions
- Cataract, Keratoconic Subjects
- Being tested
- Extended Depth of Focus Intraocular Lens Implantation
- Keywords
- EDOF IOL, Cataract, Vivity IOL, Early keratoconous, spectacle independence, optical quality, quality of life
- Medical subject headings
- Cataract
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Extended Depth of Focus Intraocular Lens ImplantationDevice
Bilateral implantation of the AcrySof IQ Vivity (Alcon, Fort Worth, TX, USA) Extended Depth of Focus (EDOF) intraocular lens during phacoemulsification cataract surgery. The Vivity is a single-piece hydrophobic acrylic IOL (6.0 mm optic, 13.0 mm overall length) featuring non-diffractive X-WAVE wavefront-shaping technology with a slightly elevated central plateau (~1 µm) and surrounding curvature modulation to extend focal range. It incorporates UV and blue light filtering with refractive index 1.55 at 35°C. The spherical model (powers +15.0 D to +25.0 D) or toric model (cylinder 1.03 D to 4.11 D at IOL plane) is selected based on corneal astigmatism. IOL power calculated using Kane formula targeting emmetropia. Surgery performed with 2.2 mm incision under topical anesthesia, with second-eye surgery within 7 days. This study specifically evaluates performance in patients with early-stage stable keratoconus.
| Study group | Role | What they receive |
|---|---|---|
| Vivity EDOF IOL in Early Keratoconus | Experimental | Adults with cataracts and mild, stable bilateral keratoconus (ABCD stage 0-1) undergo bilateral implantation of the AcrySof IQ Vivity Extended Depth of Focus (EDOF) intraocular lens during standard phacoemulsification cataract surgery. The toric version is used in eyes with regular corneal astigmatism ≥1.00 D. Surgery is performed under topical anesthesia by the same surgeon, targeting bilateral emmetropia using Kane formula for IOL power calculation. The second eye is operated within 7 days of the first. The Vivity IOL is a non-diffractive EDOF lens utilizing X-WAVE wavefront-shaping technology to extend focal range without splitting light, designed to reduce visual disturbances while providing functional vision at distance, intermediate (66 cm), and near (40 cm). Comprehensive visual, optical quality, contrast sensitivity, and patient-reported outcomes are assessed at 3 months postoperatively Receives: Device: Extended Depth of Focus Intraocular Lens Implantation |
What is being measured
The primary outcome is the main question the study is designed to answer.
Distance-Corrected Visual Acuity in the Dominant Eye
Monocular distance-corrected visual acuity (DCVA) measured in the dominant eye at 4 meters using CSO Vision Charts software version 14.0, recorded in logMAR units. Lower logMAR values indicate better visual acuity (e.g., 0.0 logMAR = Snellen 20/20; 0.1 logMAR = Snellen 20/25). Visual acuity is measured with best spectacle correction to assess the maximum visual performance achievable with the implanted IOL. The target outcome is DCVA of 0.1 logMAR (20/25) or better, indicating clinically excellent visual function. This primary endpoint evaluates whether the Vivity EDOF IOL can maintain high-quality distance vision despite the presence of mild corneal irregularities characteristic of early keratoconus
Measured: 3 months after surgery
Secondary outcomes (11)
Monocular and Binocular Uncorrected Distance Visual Acuity
Uncorrected distance visual acuity (UDVA) measured at 4 meters without spectacles using CSO Vision Charts version 14.0, recorded in logMAR units for each eye separately (monocular) and both eyes together (binocular). Lower logMAR values indicate better visual acuity. This outcome assesses spectacle independence for distance vision tasks such as driving and watching television. Results will be compared to preoperative values to determine visual improvement.
Measured: Baseline (preoperative) and 3 months after surgery
Monocular and Binocular Uncorrected and Distance-Corrected Near Visual Acuity
Near visual acuity measured at 40 cm both without spectacles (UNVA) and with distance correction (DCNVA), using CSO Vision Charts version 14.0, recorded in logMAR units monocularly and binocularly. Lower logMAR values indicate better near vision. This outcome evaluates the EDOF lens's ability to provide functional near vision for reading and smartphone use, both with and without glasses, assessing spectacle independence for near tasks. Results will be compared to preoperative values
Measured: Baseline (preoperative) and 3 months after surgery
Monocular and Binocular Uncorrected and Distance-Corrected Intermediate Visual Acuity
Intermediate visual acuity measured at 66 cm both without spectacles (UI66VA) and with distance correction (DCI66VA), using CSO Vision Charts version 14.0, recorded in logMAR units monocularly and binocularly. Lower logMAR values indicate better intermediate vision. This outcome evaluates functional vision for computer work, dashboard viewing, and other arm's-length tasks, which is a key advantage of EDOF IOLs, both with and without spectacle correction.
Measured: 3 months after surgery
Binocular Defocus Curve Visual Acuity Profile
Visual acuity measured binocularly across a range of defocus from +1.50 diopters to -3.50 diopters in 0.50 diopter increments, relative to best distance correction, using CSO Vision Charts version 14.0 with randomized letter sequences. Results plotted as logMAR visual acuity versus defocus level; lower logMAR values at each defocus level indicate better performance. This outcome characterizes the continuous range of functional vision provided by the EDOF lens from distance through intermediate to near. Positive defocus simulates hyperopia (distance blur); negative defocus simulates near viewing distances.
Measured: 3 months after surgery
Monocular and Binocular Contrast Sensitivity Under Photopic, Mesopic, and Scotopic Conditions
Contrast sensitivity measured monocularly and binocularly at multiple spatial frequencies (3, 6, 12, and 18 cycles per degree) under three lighting conditions using CSV-1000 HGT testing (Vector Vision, Greenville, OH), recorded in log units: photopic (bright light, 80 cd/m²), mesopic (dim light, 6 cd/m²), and scotopic (dark-adapted, 3 cd/m²). Higher log values indicate better contrast sensitivity. This outcome evaluates the ability to detect contrast and fine detail across different lighting environments, bright daylight, twilight/indoor low-light, and nighttime conditions, which is critical for reading, face recognition, driving, and overall visual quality. Contrast sensitivity under reduced lighting is often compromised with multifocal IOLs but may be preserved with non-diffractive EDOF designs.
Measured: 3 months after surgery
Total Root Mean Square (RMS) Wavefront Error
Total ocular higher-order aberrations measured using Pyramidal WaveFront-based aberrometer (Osiris T Aberrometer, CSO, Florence, Italy), recorded as RMS in micrometers. Lower RMS values indicate better optical quality with fewer aberrations. This objective measure evaluates whether the IOL implantation reduces the overall optical irregularities present preoperatively in keratoconus eyes. Results will be compared between preoperative and postoperative measurements
Measured: 3 months after surgery
Root Mean Square Wavefront Error at 3 mm and 4 mm Pupil Diameters
Root mean square (RMS) wavefront error measured at both 3 mm and 4 mm pupil diameters using Osiris T Aberrometer, recorded in micrometers. Lower RMS values indicate fewer optical aberrations and better optical quality. These metrics characterize optical performance under photopic conditions (3 mm pupil, naturally constricted) and mesopic conditions (4 mm pupil, moderate dilation), which may reveal greater interaction between corneal irregularities and IOL optics as pupil size increases.
Measured: 3 months after surgery
Point Spread Function Strehl Ratio at 3 mm and 4 mm Pupil Diameters
Point spread function (PSF) Strehl ratio measured at both 3 mm and 4 mm pupil diameters using Osiris T Aberrometer. The Strehl ratio ranges from 0 to 1, with higher values indicating better retinal image quality and values closer to 1.0 representing diffraction-limited optical performance. These metrics quantify how efficiently light is focused onto the retina under photopic (3 mm pupil) and mesopic (4 mm pupil) conditions, providing objective assessment of functional optical quality in keratoconus eyes with EDOF IOLs.
Measured: 3 months after surgery
Binocular Halo Perception Using Aston Halometer
Subjective halo size and intensity measured binocularly using the Aston Halometer, which displays a standardized central LED glare source (5000 K) on an iPad4. Participants indicate the perceived halo size on a radial scale. Smaller halo measurements indicate less photic disturbance. This outcome assesses one of the most common visual complaints with premium IOLs, particularly relevant for night driving and assessing tolerance in keratoconus eyes with residual aberrations.
Measured: 3 months after surgery
NEI-RQL-42 Quality of Life Scores
Patient-reported quality of life measured using the National Eye Institute Refractive Error Quality of Life Instrument-42 (NEI-RQL-42) questionnaire, consisting of 13 subscales with 42 items across 16 question/response formats. Each item is converted to a 0-100 scale, with higher scores indicating better vision-related quality of life. Subscales include clarity of vision, expectations, near vision, far vision, diurnal fluctuations, activity limitations, glare, symptoms, dependence on correction, worry, suboptimal correction, appearance, and satisfaction with correction. This validated instrument captures patient-centered functional outcomes and satisfaction.
Measured: 3 months after surgery
Incidence of Intraoperative and Postoperative Adverse Events
All intraoperative complications (e.g., posterior capsule rupture, zonular dehiscence, vitreous loss) and postoperative adverse events (e.g., endophthalmitis, increased intraocular pressure, cystoid macular edema, retinal detachment, persistent inflammation, IOL dislocation) recorded as absolute and relative frequencies. This outcome evaluates the safety profile of premium IOL implantation specifically in the keratoconus population. Lower frequencies indicate better safety.
Measured: From surgery through 3 months postoperatively
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Jan 2026
- Study start17 Sep 2024
- Primary completion13 May 2025
- Study completion13 May 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (14)Papers the sponsor has linked to this study.
- Other trials for CataractStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- This is a single-arm, prospective pilot study evaluating bilateral implantation of the AcrySof IQ Vivity Extended Depth of Focus (EDOF) intraocular lens (IOL) in patients with cataracts and early-stage, stable keratoconus. All participants receive the same intervention (Vivity EDOF IOL in both eyes, or its toric version if corneal astigmatism ≥1.00 D is present), with surgery on the second eye performed within 7 days of the first. There is no control or comparison group. The study explores whether this non-diffractive EDOF technology, which uses wavefront-shaping to extend focal range while preserving contrast sensitivity, can safely provide functional vision at multiple distances in a population (early keratoconus) traditionally considered unsuitable for premium IOLs due to corneal irregularities and higher-order aberrations. Outcomes are assessed at 3 months postoperatively.
- Masking
- None (open label)
- Enrolment
- 10 participants (actual)
Sponsor and investigators
- Lead sponsor
- Azienda Ospedaliera Universitaria Integrata Verona
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Emilio Pedrotti, Azienda Ospedaliera Universitaria Integrata Verona
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07338708
- Sponsor's protocol ID
- prot. n. 22546
- Acronym
- VIVITY-KCONUS
- Status last verified
- Jan 2026
- First submitted
- 4 Jan 2026
- Last updated
- 15 Jan 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Farideh D, Azad S, Feizollah N, Sana N, Cyrus A, Mohammad G, Alireza BR. Clinical outcomes of new toric trifocal diffractive intraocular lens in patients with cataract and stable keratoconus: Six months follow-up. Medicine (Baltimore). 2017 Mar;96(12):e6340. doi: 10.1097/MD.0000000000006340.
PubMed 28328814Rampat R, Gatinel D. Multifocal and Extended Depth-of-Focus Intraocular Lenses in 2020. Ophthalmology. 2021 Nov;128(11):e164-e185. doi: 10.1016/j.ophtha.2020.09.026. Epub 2020 Sep 25.
PubMed 32980397Pedrotti E, Chierego C, Talli PM, Selvi F, Galzignato A, Neri E, Barosco G, Montresor A, Rodella A, Marchini G. Extended Depth of Focus Versus Monofocal IOLs: Objective and Subjective Visual Outcomes. J Refract Surg. 2020 Apr 1;36(4):214-222. doi: 10.3928/1081597X-20200212-01.
PubMed 32267951Palomino-Bautista C, Sanchez-Jean R, Carmona-Gonzalez D, Pinero DP, Molina-Martin A. Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses. Int Ophthalmol. 2020 Feb;40(2):351-359. doi: 10.1007/s10792-019-01186-6. Epub 2019 Oct 3.
PubMed 31583551Gillmann K, Mermoud A. Visual Performance, Subjective Satisfaction and Quality of Life Effect of a New Refractive Intraocular Lens with Central Extended Depth of Focus. Klin Monbl Augenheilkd. 2019 Apr;236(4):384-390. doi: 10.1055/a-0799-9700. Epub 2019 Feb 14.
PubMed 30763956Pedrotti E, Mastropasqua R, Passilongo M, Parisi G, Marchesoni I, Marchini G. Comparison of two multifocal intraocular lens designs that differ only in near add. J Refract Surg. 2014 Nov;30(11):754-60. doi: 10.3928/1081597X-20141021-07.
PubMed 25375848Alio JL, Pinero DP, Plaza-Puche AB, Amparo F, Jimenez R, Rodriguez-Prats JL, Javaloy J. Visual and optical performance with two different diffractive multifocal intraocular lenses compared to a monofocal lens. J Refract Surg. 2011 Aug;27(8):570-81. doi: 10.3928/1081597X-20101223-01. Epub 2011 Jan 3.
PubMed 21210572Gil MA, Varon C, Cardona G, Vega F, Buil JA. Comparison of far and near contrast sensitivity in patients symmetrically implanted with multifocal and monofocal IOLs. Eur J Ophthalmol. 2014 Jan-Feb;24(1):44-52. doi: 10.5301/ejo.5000335. Epub 2013 Jun 24.
PubMed 23813113Buckhurst PJ, Naroo SA, Davies LN, Shah S, Drew T, Wolffsohn JS. Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses. BMJ Open Ophthalmol. 2017 Jun 19;1(1):e000064. doi: 10.1136/bmjophth-2016-000064. eCollection 2017.
PubMed 29354708de Silva SR, Evans JR, Kirthi V, Ziaei M, Leyland M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2016 Dec 12;12(12):CD003169. doi: 10.1002/14651858.CD003169.pub4.
PubMed 27943250Flockerzi E, Vinciguerra R, Belin MW, Vinciguerra P, Ambrosio R Jr, Seitz B. Combined biomechanical and tomographic keratoconus staging: Adding a biomechanical parameter to the ABCD keratoconus staging system. Acta Ophthalmol. 2022 Aug;100(5):e1135-e1142. doi: 10.1111/aos.15044. Epub 2021 Oct 16.
PubMed 34655452Vandevenne MMS, Webers VSC, Segers MHM, Berendschot TTJM, Zadok D, Dickman MM, Nuijts RMMA, Abulafia A. Accuracy of intraocular lens calculations in eyes with keratoconus. J Cataract Refract Surg. 2023 Mar 1;49(3):229-233. doi: 10.1097/j.jcrs.0000000000001088. Epub 2022 Oct 28.
PubMed 36314969Haigis W. Challenges and approaches in modern biometry and IOL calculation. Saudi J Ophthalmol. 2012 Jan;26(1):7-12. doi: 10.1016/j.sjopt.2011.11.007.
PubMed 23960962Hashemi H, Heydarian S, Hooshmand E, Saatchi M, Yekta A, Aghamirsalim M, Valadkhan M, Mortazavi M, Hashemi A, Khabazkhoob M. The Prevalence and Risk Factors for Keratoconus: A Systematic Review and Meta-Analysis. Cornea. 2020 Feb;39(2):263-270. doi: 10.1097/ICO.0000000000002150.
PubMed 31498247
Study at a glance
From the registry record, last updated by the sponsor on 15 Jan 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Assessment of Tolerance and Visual Outcomes After Bilateral Implantation of a Premium Type Intraocular Lens (Acrysof IQ Vivity IOL) in Patients With Cataract and Mild Keratoconus
- ClinicalTrials.gov ID
- NCT07338708
- Acronym / sponsor ID
- VIVITY-KCONUS / prot. n. 22546
- Conditions
- Cataract, Keratoconic Subjects
- Keywords
- EDOF IOL, Cataract, Vivity IOL, Early keratoconous, spectacle independence, optical quality, quality of life
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 10 participants (actual)
- Lead sponsor
- Azienda Ospedaliera Universitaria Integrata VeronaUniversity, hospital or other
- Study start
- 17 Sep 2024 (actual)
- Primary completion
- 13 May 2025 (actual)
- Study completion
- 13 May 2025 (actual)
- First posted
- 14 Jan 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal of this clinical trial is to learn if the Vivity Extended Depth of Focus intraocular lens works to improve vision in adults with cataracts and early-stage keratoconus. It will also learn about the safety and tolerance of this premium lens in patients with mild corneal irregularities. The main questions it aims to answer are:
- Does the Vivity EDOF lens provide good distance vision (20/25 or better) in the dominant eye at 3 months after surgery?
- Does it improve vision at intermediate and near distances compared to before surgery?
- Does it preserve contrast sensitivity and optical quality despite mild corneal irregularities?
- What is the patient-reported quality of life and satisfaction after implantation?
- What visual disturbances (such as halos) do participants experience?
All participants will:
- Receive the Vivity EDOF intraocular lens (or its toric version if astigmatism is present) in both eyes during standard cataract surgery, with the second eye operated within 7 days;
- Undergo comprehensive eye examinations before surgery including vision testing, corneal imaging, and optical quality measurements;
- Attend a follow-up visit at 3 months after surgery for detailed vision testing at multiple distances, contrast sensitivity testing under different lighting conditions, halo assessment, and quality-of-life questionnaires.
Detailed description
Background and Rationale Keratoconus (KC) is a progressive, non-inflammatory corneal ectasia characterized by stromal thinning and irregular astigmatism, often resulting in significant higher-order aberrations (HOAs) that impair visual quality. Due to these optical limitations, the use of premium intraocular lenses (pIOLs) has traditionally been considered contraindicated in these patients. However, in patients with early-stage keratoconus, corneal shape and optical quality can be relatively well preserved, with HOAs remaining within acceptable limits. These patients may thus benefit from carefully selected premium IOL technologies.
Extended-depth-of-focus (EDOF) IOLs, in contrast to traditional multifocal lenses, not only provide significantly fewer visual disturbances but, thanks to their elongated focus, they could mitigate HOAs and coma-like distortions characteristic of early keratoconus. Unlike monofocal or multifocal lenses, which rely on a single, sharp focal point or discrete focal planes, EDOF lenses are inherently designed to maintain functional retinal image quality across an extended focal range, offering greater tolerance to minor defocus and wavefront aberrations. While EDOF lenses do not correct such aberrations, their extended focal range may reduce the impact of this distortion on functional vision. This is especially true for non-diffractive EDOF lenses, which preserve high levels of contrast sensitivity by not splitting light energy into multiple focal points.
The AcrySof IQ Vivity IOL (Alcon, Fort Worth, TX, USA) is a non-diffractive EDOF IOL that uses wavefront-shaping technology to elongate the focal range. Previous studies have already demonstrated good outcomes in patients with other challenging ocular conditions such as glaucoma, macular degeneration, and epiretinal membrane. The present pilot study aims to evaluate the visual performance, tolerance, and optical quality outcomes following implantation of the Vivity IOL in patients with cataract and stable, early-stage keratoconus. This investigation explores the clinical viability of premium IOLs in a population traditionally excluded from such refractive options.
Study Design This is a prospective, interventional, single-center pilot study conducted in Italy. The study has been approved by the local ethics committee (protocol number 22546) and adheres to the principles of the Declaration of Helsinki. A total of 10 patients (20 eyes) with cataracts and mild bilateral keratoconus will be enrolled and followed for 3 months after bilateral implantation of the AcrySof IQ Vivity EDOF IOL.
Study Objectives
Primary Objective:
- To evaluate monocular distance-corrected visual acuity (DCVA) in the dominant eye at 3 months after surgery.
Secondary Objectives:
- To assess monocular and binocular uncorrected and distance-corrected visual acuity at distance (4 meters), intermediate (66 cm), and near (40 cm)
- To evaluate binocular defocus curves from +1.50 D to -3.50 D in 0.50 D increments;
- To measure monocular and binocular contrast sensitivity under photopic (80 cd/m²), mesopic (6 cd/m²), and scotopic (3 cd/m²) lighting conditions;
- To assess ocular optical quality including root mean square (RMS) wavefront error and point spread function (PSF) Strehl ratio at 3 mm and 4 mm pupil diameters;
- To evaluate binocular halo perception using standardized halometry;
- To assess patient-reported quality of life using the National Eye Institute Refractive Error Quality of Life Instrument-42 (NEI-RQL-42) questionnaire;
- To evaluate the safety profile including intra- and postoperative complications and adverse events;
- To assess toric IOL rotational stability in eyes receiving the toric version.
Eligibility criteria such as inclusion and exclusion criteria are reported separately.
Preoperative Assessment:
All patients will receive a comprehensive ophthalmologic evaluation prior to surgery, including:
- Measurement of monocular and binocular uncorrected and corrected visual acuity for distance (4 meters) and near (40 cm) using CSO Vision Charts software version 14.0
- Corneal tomography using MS-39 anterior segment optical coherence tomography (CSO, Florence, Italy)
- Ocular optical quality analysis using Pyramidal WaveFront-based sensor aberrometer (Osiris T Aberrometer, CSO, Florence, Italy) to assess higher-order aberrations including coma and coma-like aberrations
- Optical biometry using Lenstar 900 (Haag-Streit Diagnostics, Koeniz, Switzerland) for axial length and IOL power calculation
- Intraocular pressure measurement
- Slit-lamp examination of the anterior segment
- Dilated fundoscopy
- Macular evaluation through spectral-domain optical coherence tomography (Spectralis OCT, Heidelberg Engineering GmbH, Germany)
- Ocular dominance determination using the Miles test
Surgical Procedure:
All patients will undergo standard phacoemulsification cataract surgery performed by the same experienced surgeon using a 2.2 mm phaco probe under topical anesthesia. The AcrySof IQ Vivity EDOF IOL will be implanted in the capsular bag with a target of emmetropia bilaterally. IOL power calculation will be performed using the Kane formula. In eyes with regular corneal astigmatism equal to or greater than 1.00 diopter, the toric version of the Vivity IOL (AcrySof IQ Vivity Toric) will be implanted to optimize postoperative refractive outcomes. The second eye will be operated within 7 days of the first eye surgery.
Postoperative Follow-up:
Toric IOL rotational stability will be assessed on postoperative days 1 and 7 to account for early positional shifts and to allow for re-centering if necessary. The IOL will be deemed stable if the angular deviation is less than 5 degrees and if it induces a residual cylindrical error of 0.75 diopters or less, as estimated using the Toric IOL Assistant feature of the Osiris T Aberrometer.
Complete ophthalmological examination will be performed at the 3-month follow-up visit and outcome measures are measured as explained in the outcome measures section.
The Vivity IOL Technology The AcrySof IQ Vivity is a single-piece, hydrophobic acrylic EDOF IOL that utilizes a non-diffractive wavefront-shaping mechanism to enhance intermediate and near vision. The optic is 6.0 mm in diameter with an overall length of 13.0 mm and features a C-loop haptic design. The lens material incorporates both ultraviolet and blue light-filtering chromophores and has a refractive index of 1.55 at 35°C.
The lens design is based on a monofocal aspheric platform with an aberration-neutral anterior surface. The central optical zone incorporates X-WAVE technology, which integrates two subtle anterior surface transition elements: a slightly elevated central plateau (approximately 1 micrometer) that stretches the wavefront to extend the focus, and a surrounding curvature modulation that shifts the wavefront, ensuring efficient retinal energy delivery across the extended range.
The spherical model is available in powers ranging from +15.0 diopters to +25.0 diopters in 0.5 diopter increments, with additional availability up to +30.0 diopters in selected markets. The toric version, AcrySof IQ Vivity Toric, incorporates the same non-diffractive EDOF design and is offered in cylinder powers from 1.03 diopters to 4.11 diopters at the IOL plane.
Statistical Analysis All statistical analyses will be performed using STATA software, version 13.0 (StataCorp, College Station, TX, USA). The distribution of continuous variables will be assessed with the Shapiro-Wilk test. When data are normally distributed, results will be reported as mean ± standard deviation.
To evaluate the safety profile of the implanted IOL, both absolute and relative frequencies of intra- and postoperative complications, as well as any adverse events, will be recorded and analyzed at each follow-up. Paired t-tests will be conducted between preoperative and postoperative DCVA, DCNVA, UDVA, UNVA, and total RMS to assess postoperative functional improvement.
The primary endpoint is the evaluation of DCVA in the dominant eye at 3 months. A formal sample-size calculation was performed based on a previous pilot series reporting a standard deviation of 0.01 logMAR for monocular DCVA in eyes with stable keratoconus and cataract implanted with a premium IOL. A single-group design was used to estimate a 95% confidence interval for one standard deviation via the chi-square method. Assuming a standard deviation of 0.017 logMAR, 10 subjects (10 eyes) are required to yield a confidence interval half-width no greater than 0.02 logMAR (equivalent to one ETDRS letter). Sample-size calculations were carried out with PASS 2023, version 23.0.2.
Safety Considerations All participants will be carefully monitored for any adverse events or complications related to the surgical procedure or the implanted IOL. Standard cataract surgery risks include infection (endophthalmitis), inflammation, bleeding, increased intraocular pressure, lens dislocation, posterior capsule rupture, cystoid macular edema, and retinal detachment. Additional considerations specific to premium IOLs include the potential for visual disturbances such as glare, halos, starbursts, reduced contrast sensitivity, and in rare cases, dissatisfaction requiring IOL exchange.
In the specific context of keratoconus patients, there is theoretical concern that residual corneal irregularities and higher-order aberrations might interact with the IOL optics in unpredictable ways, potentially limiting visual quality or increasing photic phenomena. However, by carefully selecting only patients with early-stage, stable keratoconus and relatively preserved corneal morphology, this study aims to minimize these risks while exploring the potential benefits of EDOF technology in this population.
Any serious adverse events will be immediately reported to the ethics committee and appropriate medical management will be provided. Participants are free to withdraw from the study at any time without affecting their medical care.
Expected Outcomes and Significance This pilot study will provide preliminary evidence regarding the safety, efficacy, and patient satisfaction associated with Vivity EDOF IOL implantation in patients with early-stage keratoconus. If successful, the results may challenge the traditional view that premium IOLs are contraindicated in keratoconus and open new treatment options for carefully selected patients who wish to reduce spectacle dependence after cataract surgery.
The non-diffractive EDOF design of the Vivity lens, with its extended focal range and preserved contrast sensitivity, may be particularly well-suited to tolerating the mild corneal irregularities present in early keratoconus. By extending the depth of focus rather than creating discrete focal points, the lens may maintain functional vision despite minor wavefront aberrations.
Results from this study will inform larger, multicenter, randomized controlled trials and may ultimately contribute to updated clinical guidelines for IOL selection in keratoconus patients
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- This is a single-arm, prospective pilot study evaluating bilateral implantation of the AcrySof IQ Vivity Extended Depth of Focus (EDOF) intraocular lens (IOL) in patients with cataracts and early-stage, stable keratoconus. All participants receive the same intervention (Vivity EDOF IOL in both eyes, or its toric version if corneal astigmatism ≥1.00 D is present), with surgery on the second eye performed within 7 days of the first. There is no control or comparison group. The study explores whether this non-diffractive EDOF technology, which uses wavefront-shaping to extend focal range while preserving contrast sensitivity, can safely provide functional vision at multiple distances in a population (early keratoconus) traditionally considered unsuitable for premium IOLs due to corneal irregularities and higher-order aberrations. Outcomes are assessed at 3 months postoperatively.
| Arm | Type | Receives |
|---|---|---|
| Vivity EDOF IOL in Early Keratoconus | Experimental | Device: Extended Depth of Focus Intraocular Lens ImplantationAdults with cataracts and mild, stable bilateral keratoconus (ABCD stage 0-1) undergo bilateral implantation of the AcrySof IQ Vivity Extended Depth of Focus (EDOF) intraocular lens during standard phacoemulsification cataract surgery. The toric version is used in eyes with regular corneal astigmatism ≥1.00 D. Surgery is performed under topical anesthesia by the same surgeon, targeting bilateral emmetropia using Kane formula for IOL power calculation. The second eye is operated within 7 days of the first. The Vivity IOL is a non-diffractive EDOF lens utilizing X-WAVE wavefront-shaping technology to extend focal range without splitting light, designed to reduce visual disturbances while providing functional vision at distance, intermediate (66 cm), and near (40 cm). Comprehensive visual, optical quality, contrast sensitivity, and patient-reported outcomes are assessed at 3 months postoperatively |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (8 listed)
- Adults requiring bilateral cataract surgery
- Mild bilateral keratoconus defined as stage 0-1 according to the ABCD classification system
- Keratoconus stability defined as maximum keratometry (K) changes less than 1 diopter and maximum pachymetry reduction less than 2% within the previous 5 years
- Pre-cataract spectacle distance-corrected visual acuity of 0.1 to 0.0 LogMAR (Snellen 20/25 to 20/20)
- Agreement to bilateral implantation of AcrySof IQ Vivity Extended Depth of Focus intraocular lens
Key exclusion criteria (8 listed)
- Any ocular comorbidities other than cataract and keratoconus, or history of any disease that could affect visual results (e.g., glaucoma, retinal disorders)
- Corneal opacity including any corneal scarring
- Advanced or progressive keratoconus
- Any previous ocular surgery other than corneal cross-linking performed at least 5 years prior to enrollment
- Corneal cross-linking performed within 5 years prior to enrollment
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Extended Depth of Focus Intraocular Lens ImplantationBilateral implantation of the AcrySof IQ Vivity (Alcon, Fort Worth, TX, USA) Extended Depth of Focus (EDOF) intraocular lens during phacoemulsification cataract surgery. The Vivity is a single-piece hydrophobic acrylic IOL (6.0 mm optic, 13.0 mm overall length) featuring non-diffractive X-WAVE wavefront-shaping technology with a slightly elevated central plateau (~1 µm) and surrounding curvature modulation to extend focal range. It incorporates UV and blue light filtering with refractive index 1.55 at 35°C. The spherical model (powers +15.0 D to +25.0 D) or toric model (cylinder 1.03 D to 4.11 D at IOL plane) is selected based on corneal astigmatism. IOL power calculated using Kane formula targeting emmetropia. Surgery performed with 2.2 mm incision under topical anesthesia, with second-eye surgery within 7 days. This study specifically evaluates performance in patients with early-stage stable keratoconus. | Device | Vivity EDOF IOL in Early Keratoconus |
Primary outcome
Distance-Corrected Visual Acuity in the Dominant Eye
Time frame: 3 months after surgery
Monocular distance-corrected visual acuity (DCVA) measured in the dominant eye at 4 meters using CSO Vision Charts software version 14.0, recorded in logMAR units. Lower logMAR values indicate better visual acuity (e.g., 0.0 logMAR = Snellen 20/20; 0.1 logMAR = Snellen 20/25). Visual acuity is measured with best spectacle correction to assess the maximum visual performance achievable with the implanted IOL. The target outcome is DCVA of 0.1 logMAR (20/25) or better, indicating clinically excellent visual function. This primary endpoint evaluates whether the Vivity EDOF IOL can maintain high-quality distance vision despite the presence of mild corneal irregularities characteristic of early keratoconus
11 secondary outcomes
Monocular and Binocular Uncorrected Distance Visual Acuity
Time frame: Baseline (preoperative) and 3 months after surgery
Monocular and Binocular Uncorrected and Distance-Corrected Near Visual Acuity
Time frame: Baseline (preoperative) and 3 months after surgery
Monocular and Binocular Uncorrected and Distance-Corrected Intermediate Visual Acuity
Time frame: 3 months after surgery
Binocular Defocus Curve Visual Acuity Profile
Time frame: 3 months after surgery
Monocular and Binocular Contrast Sensitivity Under Photopic, Mesopic, and Scotopic Conditions
Time frame: 3 months after surgery
Total Root Mean Square (RMS) Wavefront Error
Time frame: 3 months after surgery
Root Mean Square Wavefront Error at 3 mm and 4 mm Pupil Diameters
Time frame: 3 months after surgery
Point Spread Function Strehl Ratio at 3 mm and 4 mm Pupil Diameters
Time frame: 3 months after surgery
Binocular Halo Perception Using Aston Halometer
Time frame: 3 months after surgery
NEI-RQL-42 Quality of Life Scores
Time frame: 3 months after surgery
Incidence of Intraoperative and Postoperative Adverse Events
Time frame: From surgery through 3 months postoperatively
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Jan 2026.
- Background: PubMed 28328814Farideh D, Azad S, Feizollah N, Sana N, Cyrus A, Mohammad G, Alireza BR. Clinical outcomes of new toric trifocal diffractive intraocular lens in patients with cataract and stable keratoconus: Six months follow-up. Medicine (Baltimore). 2017 Mar;96(12):e6340. doi: 10.1097/MD.0000000000006340.
- Background: PubMed 32980397Rampat R, Gatinel D. Multifocal and Extended Depth-of-Focus Intraocular Lenses in 2020. Ophthalmology. 2021 Nov;128(11):e164-e185. doi: 10.1016/j.ophtha.2020.09.026. Epub 2020 Sep 25.
- Background: PubMed 32267951Pedrotti E, Chierego C, Talli PM, Selvi F, Galzignato A, Neri E, Barosco G, Montresor A, Rodella A, Marchini G. Extended Depth of Focus Versus Monofocal IOLs: Objective and Subjective Visual Outcomes. J Refract Surg. 2020 Apr 1;36(4):214-222. doi: 10.3928/1081597X-20200212-01.
- Background: PubMed 31583551Palomino-Bautista C, Sanchez-Jean R, Carmona-Gonzalez D, Pinero DP, Molina-Martin A. Subjective and objective depth of field measures in pseudophakic eyes: comparison between extended depth of focus, trifocal and bifocal intraocular lenses. Int Ophthalmol. 2020 Feb;40(2):351-359. doi: 10.1007/s10792-019-01186-6. Epub 2019 Oct 3.
- Background: PubMed 30763956Gillmann K, Mermoud A. Visual Performance, Subjective Satisfaction and Quality of Life Effect of a New Refractive Intraocular Lens with Central Extended Depth of Focus. Klin Monbl Augenheilkd. 2019 Apr;236(4):384-390. doi: 10.1055/a-0799-9700. Epub 2019 Feb 14.
- Background: PubMed 25375848Pedrotti E, Mastropasqua R, Passilongo M, Parisi G, Marchesoni I, Marchini G. Comparison of two multifocal intraocular lens designs that differ only in near add. J Refract Surg. 2014 Nov;30(11):754-60. doi: 10.3928/1081597X-20141021-07.
- Background: PubMed 21210572Alio JL, Pinero DP, Plaza-Puche AB, Amparo F, Jimenez R, Rodriguez-Prats JL, Javaloy J. Visual and optical performance with two different diffractive multifocal intraocular lenses compared to a monofocal lens. J Refract Surg. 2011 Aug;27(8):570-81. doi: 10.3928/1081597X-20101223-01. Epub 2011 Jan 3.
- Background: PubMed 23813113Gil MA, Varon C, Cardona G, Vega F, Buil JA. Comparison of far and near contrast sensitivity in patients symmetrically implanted with multifocal and monofocal IOLs. Eur J Ophthalmol. 2014 Jan-Feb;24(1):44-52. doi: 10.5301/ejo.5000335. Epub 2013 Jun 24.
- Background: PubMed 29354708Buckhurst PJ, Naroo SA, Davies LN, Shah S, Drew T, Wolffsohn JS. Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses. BMJ Open Ophthalmol. 2017 Jun 19;1(1):e000064. doi: 10.1136/bmjophth-2016-000064. eCollection 2017.
- Background: PubMed 27943250de Silva SR, Evans JR, Kirthi V, Ziaei M, Leyland M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst Rev. 2016 Dec 12;12(12):CD003169. doi: 10.1002/14651858.CD003169.pub4.
- Background: PubMed 34655452Flockerzi E, Vinciguerra R, Belin MW, Vinciguerra P, Ambrosio R Jr, Seitz B. Combined biomechanical and tomographic keratoconus staging: Adding a biomechanical parameter to the ABCD keratoconus staging system. Acta Ophthalmol. 2022 Aug;100(5):e1135-e1142. doi: 10.1111/aos.15044. Epub 2021 Oct 16.
- Background: PubMed 36314969Vandevenne MMS, Webers VSC, Segers MHM, Berendschot TTJM, Zadok D, Dickman MM, Nuijts RMMA, Abulafia A. Accuracy of intraocular lens calculations in eyes with keratoconus. J Cataract Refract Surg. 2023 Mar 1;49(3):229-233. doi: 10.1097/j.jcrs.0000000000001088. Epub 2022 Oct 28.
- Individual participant dataSharing planned: No
Related trials for Cataract
Recruiting
Implementing AI-based Glaucoma Screening Within Federally Qualified Health Centers
Glaucoma, Ocular Hypertension
Not yet recruiting
Trial to Investigate the Safety and Effectiveness of the KI-362-US1 (YP2.2VM) Intraocular Lens (IOL) in Adult Participants for Correction of Aphakia Following Cataract Extraction
Aphakia, Postcataract
Not yet recruiting
Effects of Oxygen Cage Support During Cataract Surgery
Cataract
Active, not recruitingObservational study
Age-Related Eye Disease Study (AREDS) Follow-Up
Age-Related Macular Degeneration, Cataract
RecruitingObservational study
Objective Depth-of-Focus Changes During Light Adjustable Lens UV Adjustments
Light Adjustable Lens, Objective Depth of Focus
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Extended Depth of Focus Intraocular Lens Implantation in people with Cataract and Keratoconic Subjects, run by Azienda Ospedaliera Universitaria Integrata Verona at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 8 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 15 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Distance-Corrected Visual Acuity in the Dominant Eye (time frame: 3 months after surgery). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07338708, which also lists 14 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jan 2026.