AzTrials
AzTrials

Intraoperative HemodynamicsPRAM-ZTOTNCT07340333

Physiological Reference Values of Total Arterial Impedance Derived From PRAM Monitoring

An observational study of Intraoperative Hemodynamics, run by Ataturk University at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Total arterial impedance (Ztot) is an advanced hemodynamic parameter that reflects the global arterial load opposing ventricular ejection by integrating both steady and pulsatile components of the arterial system. Read more about this study

Who is it for?
Ages 18 to 75 years
Conditions the study is for
Intraoperative Hemodynamics
How many people
437 participants
Where
1 siteTurkey (Türkiye)
Study dates
30 Jan 2026to 2 Feb 2026
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 75 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: The study population consists of adult surgical patients who underwent routine intraoperative invasive arterial monitoring, from whom PRAM-based hemodynamic data were retrospectively analyzed during predefined hemodynamically stable intraoperative periods.

Who may be able to join

  • Adult patients (≥18 years) who underwent surgery with invasive arterial catheterization.
  • Availability of intraoperative hemodynamic data recorded using PRAM-based arterial waveform monitoring.
  • Presence of predefined hemodynamically stable intraoperative periods meeting physiological stability criteria.
  • Adequate arterial waveform signal quality for PRAM-derived parameter analysis.

Who cannot join

  • Age <18 years.
  • Inadequate arterial waveform signal quality or missing PRAM-derived data.
  • Absence of intraoperative periods fulfilling predefined hemodynamic stability criteria.
  • Incomplete or corrupted intraoperative monitoring records.

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Ataturk University

    Erzurum, 25240

Other trials in Turkey (Türkiye)

About this study

Official title: Reference Values and Hemodynamic Associations of Total Arterial Impedance Derived From PRAM Monitoring During Hemodynamically Stable Intraoperative Periods

Total arterial impedance (Ztot) is an advanced hemodynamic parameter that reflects the global arterial load opposing ventricular ejection by integrating both steady and pulsatile components of the arterial system. Although Ztot can be continuously derived from Pressure Recording Analytical Method (PRAM)-based monitoring, physiological reference values under stable clinical conditions are not well established.

This observational study aims to define patient-level physiological reference values for Ztot using intraoperative hemodynamic data obtained from PRAM-based arterial waveform analysis during hemodynamically stable periods. In addition, the study evaluates the associations between Ztot and key hemodynamic variables reflecting arterial load and cardiovascular performance.

High-resolution intraoperative data routinely recorded during standard clinical care are retrospectively analyzed. The findings of this study are intended to improve the interpretability of Ztot in advanced hemodynamic monitoring and to support future clinical and research applications.

Read the detailed description

Total arterial impedance (Ztot) is a comprehensive descriptor of arterial load that integrates resistive, compliant, and pulsatile components of the arterial system. Unlike conventional pressure-based parameters, Ztot provides a more physiologically meaningful representation of the opposition encountered by ventricular ejection. Although Ztot can be continuously estimated using Pressure Recording Analytical Method (PRAM)-based arterial waveform analysis, standardized physiological reference values applicable to routine clinical practice are lacking.

This single-center, observational study is designed to establish patient-level reference values for PRAM-derived Ztot during hemodynamically stable intraoperative periods. The study retrospectively analyzes high-resolution intraoperative hemodynamic data obtained during routine clinical care. Adult surgical patients monitored with an invasive arterial catheter and PRAM-based hemodynamic monitoring are included in the analysis.

Hemodynamic stability is defined according to predefined physiological criteria, including ranges of mean arterial pressure, cardiac index, heart rate, stroke volume variation, cardiac cycle efficiency, and arterial waveform quality indicators. Only measurements meeting all stability criteria are considered eligible for analysis.

To account for repeated measurements within individuals, patient-level median values are used for all primary analyses. The physiological reference interval for Ztot is estimated using a non-parametric percentile-based approach. In addition, associations between Ztot and key hemodynamic variables related to arterial load and cardiovascular performance are explored using correlation analyses.

This study does not involve any interventions, treatment assignments, or changes to standard clinical management. The primary objective is descriptive and physiological, aiming to provide a reference framework that may enhance the clinical interpretability of Ztot in advanced hemodynamic monitoring. The results are expected to support future prospective and outcome-oriented research evaluating the role of Ztot in perioperative and critical care settings.

Keywords
Total arterial impedance, PRAM monitoring, Arterial load, Advanced hemodynamic monitoring, Pressure waveform analysis, Physiological reference values, Intraoperative hemodynamics

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

Study groups in NCT07340333
Study groupRoleWhat they receive
Intraoperative PRAM Monitoring CohortAdult surgical patients with invasive arterial monitoring whose intraoperative hemodynamic data were retrospectively analyzed during predefined hemodynamically stable periods using PRAM-based waveform analysis.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Physiological reference interval of total arterial impedance (Ztot)

    Patient-level physiological reference interval (2.5th-97.5th percentiles) of PRAM-derived total arterial impedance (Ztot) calculated from intraoperative hemodynamic measurements obtained during predefined hemodynamically stable periods.

    Measured: Intraoperative period

Secondary outcomes (2)
  1. Association between total arterial impedance and arterial load-related hemodynamic variables

    Correlation between patient-level total arterial impedance (Ztot) and arterial load-related hemodynamic variables, including effective arterial elastance and systemic vascular resistance.

    Measured: Intraoperative period

  2. Association between total arterial impedance and cardiovascular performance indices

    Association between patient-level total arterial impedance (Ztot) and indices of cardiovascular performance, including cardiac output, stroke volume, cardiac power output, and cardiac cycle efficiency.

    Measured: Intraoperative period

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Jan 2026
  2. Study start30 Jan 2026
  3. Primary completion2 Feb 2026
  4. Study completion2 Feb 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Retrospective
Enrolment
437 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07340333
Sponsor's protocol ID
ATAUNI-PRAM-ZTOT-2026
Other IDs
2026/1
Acronym
PRAM-ZTOT
Status last verified
Feb 2026
First submitted
6 Jan 2026
Last updated
4 Feb 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data will not be shared due to institutional and ethical restrictions related to patient privacy and the retrospective nature of the study. The analyzed data consist of anonymized intraoperative monitoring records collected during routine clinical care. Aggregated and summary-level results are reported in publications, and additional information may be made available upon reasonable request and with appropriate institutional approval.

Publications

  • Vlachopoulos C, O'Rourke M, Nichols WW. McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles. 6 ed. Boca Raton, FL: CRC Press; 2011.

  • Kelly RP, Ting CT, Yang TM, Liu CP, Maughan WL, Chang MS, Kass DA. Effective arterial elastance as index of arterial vascular load in humans. Circulation. 1992 Aug;86(2):513-21. doi: 10.1161/01.cir.86.2.513.

    PubMed 1638719
  • Kass DA. Ventricular arterial stiffening: integrating the pathophysiology. Hypertension. 2005 Jul;46(1):185-93. doi: 10.1161/01.HYP.0000168053.34306.d4. Epub 2005 May 23.

    PubMed 15911741
  • Sunagawa K, Sagawa K, Maughan WL. Ventricular interaction with the loading system. Ann Biomed Eng. 1984;12(2):163-89. doi: 10.1007/BF02584229.

    PubMed 6507965
  • Westerhof N, Lankhaar JW, Westerhof BE. The arterial Windkessel. Med Biol Eng Comput. 2009 Feb;47(2):131-41. doi: 10.1007/s11517-008-0359-2. Epub 2008 Jun 10.

    PubMed 18543011
  • O'Rourke M, Adji A, Nichols WW, Vlachopoulos C, Edelman ER. Application of Arterial Hemodynamics to Clinical Practice: A Testament to Medical Science in London. Artery Res. 2017 Jun;18:81-86. doi: 10.1016/j.artres.2017.03.003. No abstract available.

    PubMed 29861794
  • de Keijzer IN, Scheeren TWL. Perioperative Hemodynamic Monitoring: An Overview of Current Methods. Anesthesiol Clin. 2021 Sep;39(3):441-456. doi: 10.1016/j.anclin.2021.03.007. Epub 2021 Jul 12.

    PubMed 34392878
  • Pinsky MR. Functional hemodynamic monitoring. Crit Care Clin. 2015 Jan;31(1):89-111. doi: 10.1016/j.ccc.2014.08.005.

    PubMed 25435480

Questions about this trial

What is this clinical trial studying?

An observational study of Intraoperative Hemodynamics, run by Ataturk University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Physiological reference interval of total arterial impedance (Ztot) (time frame: Intraoperative period). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07340333, which also lists 8 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Feb 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in