EdentulismNCT07377890
Accuracy of Digital vs Conventional Denture Impressions: An In Vivo Study
A study testing Digital and conventional impressions in people with Edentulism and Complete Dentures, run by Mohammed Bin Rashid University of Medicine and Health Sciences at 1 site in United Arab Emirates.
Trial summary
The goal of this clinical trial is to compare the accuracy of two denture impression techniques, digital intraoral scanning and conventional border-molded impressions, in adults who have lost all their teeth (fully edentulous patients). Read more about this study
- Who is it for?
- Ages 18 to 85 years
- Conditions the study is for
- Edentulism, Complete Dentures, Digital Impression Accuracy
- What is being tested?
- Digital and conventional impressions
- Type of treatment
- Pill or oral medicine, Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteUnited Arab Emirates
- Study dates
- 1 Oct 2025to 1 Jun 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 85 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients attending DDH for complete dental prosthesis.
- Fully edentulous patients
- All alveolar ridge classifications of Cawood and Howell 1988 (Cawood and Howell, 1988)
- Above 18 years old
- Arabic and English-speaking patients
- Good physical health (ASA class 1 or 2)
- Willing to provide informed consent.
Who cannot join
- Dentate patients
- Implant-attachment-supported complete denture.
- Patients un-willing to participate (non-consented patients)
- Patients with severe gag reflex
- Patients who are mentally unstable, drug users or alcoholics
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
United Arab Emirates1 site, 1 recruiting
- Recruiting
Dubai Dental Hospital
Dubai, 505055
Khadeeja Abdul Rahiman, 00971050953219, khadeeja.abdul@dubaihealth.ae
About this study
Official title: Accuracy of Intraorally Scanned Denture Impressions Compared to Conventional Border-Molded Impressions: An In Vivo Study
The goal of this clinical trial is to compare the accuracy of two denture impression techniques, digital intraoral scanning and conventional border-molded impressions, in adults who have lost all their teeth (fully edentulous patients).
The main questions it aims to answer are:
Read more
Is a digital intraoral scan as accurate as a conventional impression for capturing the shape of the mouth, including movable gum areas? Are repeated digital scans consistent (precise) when taken multiple times on the same patient? Researchers will compare digital impressions taken with an intraoral scanner to conventional impressions made with custom trays and border molding to see if digital scans can match the accuracy of the traditional "gold standard" method.
Participants will:
Attend Dubai Dental Hospital for two study visits. Have their mouth scanned three times using a digital intraoral scanner. Have a conventional impression taken using a custom tray and high-accuracy material after border molding.
Provide informed consent and allow their impression data to be analyzed for accuracy.
- Being tested
- Digital and conventional impressions
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Digital and conventional impressionsProcedure or surgery
Also called intra-oral scanning, border-molded impression
Participants will first receive digital intraoral scanning of their fully edentulous upper and/or lower jaw using the TRIOS 5 intraoral scanner (3Shape). The scanning process follows a structured sequence to capture the entire arch, including the palate and ridge slopes. Each arch will be scanned three times during the same visit to assess precision (consistency of repeated scans). Then the same participants will also undergo a conventional impression procedure using a custom tray and border molding technique.
| Study group | Role | What they receive |
|---|---|---|
| Edentulous patients | Experimental | Arm Description:
Participants will first receive digital intraoral scanning of their fully edentulous upper and/or lower jaw using the TRIOS 5 intraoral scanner (3Shape). The scanning process follows a structured sequence to capture the entire arch, including the palate and ridge slopes. Each arch will be scanned three times during the same visit to assess precision (consistency of repeated scans). Then the same participants will also undergo a conventional impression procedure using a custom tray and border molding technique. Receives: Procedure: Digital and conventional impressions |
What is being measured
The primary outcome is the main question the study is designed to answer.
Trueness of Digital Impressions: Mean root mean square Deviation (mm) between intraoral scanner (IOS) digital impressions and conventional impression scans-per arch
Trueness will be checked by looking at the Root Mean Square (RMS) deviation (mm) after superimposing the IOS Standard Tessellation Language (STL) over the conventional impression scan STL (reference) using Geomagic Control X. The primary metric is the participant-level mean RMS over the full arch surface (edentulous maxilla and mandible analyzed separately). Lower RMS indicates greater trueness (higher accuracy). Region-specific RMS (static vs. dynamic tissues) will be recorded as prespecified analyses (see secondary outcomes).
Alignment: Initial + best-fit alignment; conventional scan = reference file. Reporting (participant level): Mean RMS (mm) per arch. Reporting (study level): Mean [Standard Deviation (SD)], RMS per arch; 95% CI; distribution plots as applicable.
Unit of Measure: millimeters (mm), RMS deviation Regions analyzed: Static (palatal rugae, ridge slopes, crest) and dynamic (labial, buccal, lingual sulci, hamular notch, posterior palatal seal).
Measured: 1 week
Precision of Digital Impressions: Within-Subject Mean Pairwise RMS Deviation (mm) Across Three IOS Scans (Precision)-per Arch
Precision will be quantified by pairwise deviation analysis between three repeated IOS scans per arch taken on the same day. STL files will be aligned (Initial + Best-Fit ICP) in Geomagic Control X. For each arch, the following pairs will be analyzed: (Scan1-Scan2), (Scan1-Scan3), and (Scan2-Scan3). Each pair will be aligned in both directions (each file alternately as reference), and all RMS values will be averaged to yield the participant-level mean pairwise RMS (mm) for that arch. Lower RMS indicates greater precision (repeatability).
Reporting (participant level): Mean of all pairwise RMS values per arch. Reporting (study level): Mean (SD) RMS per arch; 95% CI; distribution plots as applicable.
Unit of Measure: millimeters (mm), RMS deviation
Measured: 1 week
Secondary outcomes (2)
The difference (mm) in mean RMS trueness between the maxillary and mandibular arches is measured.
Compute mean RMS trueness (mm) per arch (as defined in Primary Outcome 1). The between-arch difference will be calculated as maxilla minus mandible (mm). Positive values indicate higher RMS (worse trueness) in the maxilla.
Reporting (study level): Mean (SD) difference; 95% CI; paired analysis. Unit of Measure: millimeters (mm), RMS deviation
Measured: 1 week
Difference (mm) in mean RMS trueness between static (attached) and dynamic (mobile) regions.
Within each arch, participant-level trueness RMS (mm) will be computed separately for prespecified static regions (palatal rugae; buccal and palatal/lingual slopes; ridge crest) and dynamic regions (labial, buccal, and lingual sulci; hamular notch; posterior palatal seal). The regional difference will be calculated as Dynamic minus Static (mm). Positive values indicate higher RMS (worse trueness) in mobile tissues.
Reporting (study level): Mean (SD) difference; 95% CI; by arch as applicable. Unit of Measure: millimeters (mm), RMS deviation
Measured: 1 week
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted30 Jan 2026
- Study start1 Oct 2025
- Primary completion1 May 2026 (estimated)
- Study completion1 Jun 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (3)Papers the sponsor has linked to this study.
- Other trials for EdentulismStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 10 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Mohammed Bin Rashid University of Medicine and Health Sciences
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Fatemeh Amir-Rad, Mohammed Bin Rashid University of Medicine and Health Sciences
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07377890
- Sponsor's protocol ID
- MBRU IRB-2024-107
- Status last verified
- Jan 2026
- First submitted
- 13 Jan 2026
- Last updated
- 30 Jan 2026
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Publications
Zarone F, Ruggiero G, Ferrari M, Mangano F, Joda T, Sorrentino R. Comparison of different intraoral scanning techniques on the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis. J Prosthet Dent. 2020 Dec;124(6):762.e1-762.e8. doi: 10.1016/j.prosdent.2020.07.017. Epub 2020 Oct 24.
PubMed 33289648Al Hamad KQ, Al-Kaff FT. Trueness of intraoral scanning of edentulous arches: A comparative clinical study. J Prosthodont. 2023 Jan;32(1):26-31. doi: 10.1111/jopr.13597. Epub 2022 Sep 6.
PubMed 35997079Casucci A, Mazzitelli C, Tsiplakis V, D'Arienzo LF, Breschi L, Ferrari M. Digital Impressions in Edentulous Patients: A Systematic Review for Clinical Evidence. Int J Prosthodont. 2023 Sep 12;36(4):486-497. doi: 10.11607/ijp.7483.
PubMed 37699190
Study at a glance
From the registry record, last updated by the sponsor on 30 Jan 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Accuracy of Intraorally Scanned Denture Impressions Compared to Conventional Border-Molded Impressions: An In Vivo Study
- ClinicalTrials.gov ID
- NCT07377890
- Acronym / sponsor ID
- MBRU IRB-2024-107
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 10 participants (estimated)
- Lead sponsor
- Mohammed Bin Rashid University of Medicine and Health SciencesUniversity, hospital or other
- Study start
- 1 Oct 2025 (actual)
- Primary completion
- 1 May 2026 (estimated)
- Study completion
- 1 Jun 2026 (estimated)
- First posted
- 30 Jan 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal of this clinical trial is to compare the accuracy of two denture impression techniques, digital intraoral scanning and conventional border-molded impressions, in adults who have lost all their teeth (fully edentulous patients).
The main questions it aims to answer are:
Is a digital intraoral scan as accurate as a conventional impression for capturing the shape of the mouth, including movable gum areas? Are repeated digital scans consistent (precise) when taken multiple times on the same patient? Researchers will compare digital impressions taken with an intraoral scanner to conventional impressions made with custom trays and border molding to see if digital scans can match the accuracy of the traditional "gold standard" method.
Participants will:
Attend Dubai Dental Hospital for two study visits. Have their mouth scanned three times using a digital intraoral scanner. Have a conventional impression taken using a custom tray and high-accuracy material after border molding.
Provide informed consent and allow their impression data to be analyzed for accuracy.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Edentulous patients | Experimental | Procedure: Digital and conventional impressionsArm Description: Participants will first receive digital intraoral scanning of their fully edentulous upper and/or lower jaw using the TRIOS 5 intraoral scanner (3Shape). The scanning process follows a structured sequence to capture the entire arch, including the palate and ridge slopes. Each arch will be scanned three times during the same visit to assess precision (consistency of repeated scans). Then the same participants will also undergo a conventional impression procedure using a custom tray and border molding technique. |
Who may qualify
- Ages
- 18 to 85 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (7 listed)
- Patients attending DDH for complete dental prosthesis.
- Fully edentulous patients
- All alveolar ridge classifications of Cawood and Howell 1988 (Cawood and Howell, 1988)
- Above 18 years old
- Arabic and English-speaking patients
Key exclusion criteria (5 listed)
- Dentate patients
- Implant-attachment-supported complete denture.
- Patients un-willing to participate (non-consented patients)
- Patients with severe gag reflex
- Patients who are mentally unstable, drug users or alcoholics
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Digital and conventional impressionsAlso: intra-oral scanning, border-molded impressionParticipants will first receive digital intraoral scanning of their fully edentulous upper and/or lower jaw using the TRIOS 5 intraoral scanner (3Shape). The scanning process follows a structured sequence to capture the entire arch, including the palate and ridge slopes. Each arch will be scanned three times during the same visit to assess precision (consistency of repeated scans). Then the same participants will also undergo a conventional impression procedure using a custom tray and border molding technique. | Procedure or surgery | Edentulous patients |
Primary outcome
Trueness of Digital Impressions: Mean root mean square Deviation (mm) between intraoral scanner (IOS) digital impressions and conventional impression scans-per arch
Time frame: 1 week
Trueness will be checked by looking at the Root Mean Square (RMS) deviation (mm) after superimposing the IOS Standard Tessellation Language (STL) over the conventional impression scan STL (reference) using Geomagic Control X. The primary metric is the participant-level mean RMS over the full arch surface (edentulous maxilla and mandible analyzed separately). Lower RMS indicates greater trueness (higher accuracy). Region-specific RMS (static vs. dynamic tissues) will be recorded as prespecified analyses (see secondary outcomes). Alignment: Initial + best-fit alignment; conventional scan = reference file. Reporting (participant level): Mean RMS (mm) per arch. Reporting (study level): Mean [Standard Deviation (SD)], RMS per arch; 95% CI; distribution plots as applicable. Unit of Measure: millimeters (mm), RMS deviation Regions analyzed: Static (palatal rugae, ridge slopes, crest) and dynamic (labial, buccal, lingual sulci, hamular notch, posterior palatal seal).
Precision of Digital Impressions: Within-Subject Mean Pairwise RMS Deviation (mm) Across Three IOS Scans (Precision)-per Arch
Time frame: 1 week
Precision will be quantified by pairwise deviation analysis between three repeated IOS scans per arch taken on the same day. STL files will be aligned (Initial + Best-Fit ICP) in Geomagic Control X. For each arch, the following pairs will be analyzed: (Scan1-Scan2), (Scan1-Scan3), and (Scan2-Scan3). Each pair will be aligned in both directions (each file alternately as reference), and all RMS values will be averaged to yield the participant-level mean pairwise RMS (mm) for that arch. Lower RMS indicates greater precision (repeatability). Reporting (participant level): Mean of all pairwise RMS values per arch. Reporting (study level): Mean (SD) RMS per arch; 95% CI; distribution plots as applicable. Unit of Measure: millimeters (mm), RMS deviation
2 secondary outcomes
The difference (mm) in mean RMS trueness between the maxillary and mandibular arches is measured.
Time frame: 1 week
Difference (mm) in mean RMS trueness between static (attached) and dynamic (mobile) regions.
Time frame: 1 week
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Jan 2026.
- Background: PubMed 33289648Zarone F, Ruggiero G, Ferrari M, Mangano F, Joda T, Sorrentino R. Comparison of different intraoral scanning techniques on the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis. J Prosthet Dent. 2020 Dec;124(6):762.e1-762.e8. doi: 10.1016/j.prosdent.2020.07.017. Epub 2020 Oct 24.
- Background: PubMed 35997079Al Hamad KQ, Al-Kaff FT. Trueness of intraoral scanning of edentulous arches: A comparative clinical study. J Prosthodont. 2023 Jan;32(1):26-31. doi: 10.1111/jopr.13597. Epub 2022 Sep 6.
- Background: PubMed 37699190Casucci A, Mazzitelli C, Tsiplakis V, D'Arienzo LF, Breschi L, Ferrari M. Digital Impressions in Edentulous Patients: A Systematic Review for Clinical Evidence. Int J Prosthodont. 2023 Sep 12;36(4):486-497. doi: 10.11607/ijp.7483.
- Related InfoLink provided by the sponsor.
- Related InfoLink provided by the sponsor.
- Related InfoLink provided by the sponsor.
- Individual participant dataSharing planned: Undecided
Related trials for Edentulism
Active, not recruiting
Influence of Implant Insertion Depth on Peri-implant Bone Changes Around Short Implants
Tooth Loss, Edentulism
Recruiting
Dental Implant Healing With TNF-Alpha Inhibitors
Dental Implants, TNF-alpha Inhibitors
Not yet recruitingObservational study
Russian Version of OHIP-EDENT-19 for Adults With Complete Tooth Loss
Edentulism
Not yet recruitingObservational study
Digital and Conventional Clasp-retained Partial Dentures (DIGICLASP)
Partial Edentulism
Recruiting
The Application of a Biphasic Calcium Sulfate Graft Material in Sinus Floor Elevation
Alveolar Bone Loss, Edentulism Nos
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Digital and conventional impressions in people with Edentulism and Complete Dentures, run by Mohammed Bin Rashid University of Medicine and Health Sciences at 1 site in United Arab Emirates.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 7 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 30 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Arab Emirates. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Each site lists its own contact: choose the nearest one under Trial locations. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Trueness of Digital Impressions: Mean root mean square Deviation (mm) between intraoral scanner (IOS) digital impressions and conventional impression scans-per arch (time frame: 1 week). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07377890, which also lists 3 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Jan 2026.