Non-valvular Atrial Fibrillation (NVAF)NCT07385599
FIM Study of the LAmbre™ II LAA Occluder in Non-Valvular AF Patients
A study testing LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System in people with Non-valvular Atrial Fibrillation (NVAF), run by Lifetech Scientific (Shenzhen) Co., Ltd. at 1 site in Hong Kong.
Trial summary
To evaluate the preliminary safety and feasibility of the LAmbreTM II Left Atrial Appendage Occluder and the Occluder Delivery System in patients with non-valvular atrial fibrillation who are at increased risk for stroke and systemic embolism. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Non-valvular Atrial Fibrillation (NVAF)
- What is being tested?
- LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteHong Kong
- Study dates
- 19 Jan 2026to 1 Mar 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- The patient age ≥18 years;
- The patient has documented paroxysmal, persistent, or permanent non-valvular atrial fibrillation;
- The patient has a CHA2DS2-VASc score of ≥ 2 in men and CHA2DS2-VASc score of ≥ 3 in women;
- The patient is recommended for oral anticoagulation therapy, but there is an appropriate rationale for seeking a non-pharmacologic alternative to oral anticoagulation;
- The patient is deemed suitable for LAA closure by the site investigator and a clinician not a part of the procedural team in the shared decision-making process, and this determination has been documented in the patient's medical record;
- The patient is willing and able to comply with the required medication post-procedure and follow-up evaluations;
- The patient (or his or her legally authorized representative) has been informed of the nature of the study, agrees to its provisions, and has been provided written informed consent approved by the appropriate Institutional Review Board (IRB) or Ethics Committee (EC)
Who cannot join
- Pregnant or nursing patients and those who plan pregnancy during the study period. Female patients of childbearing potential must have a negative pregnancy test (per site standard test) within 7 days prior to the index procedure;
- Patients with atrial fibrillation that is defined by a single occurrence, or that is transient or reversible (e.g., secondary to CABG, an interventional procedure, pneumonia, or hyperthyroidism);
- Patients who require long-term anticoagulation for a condition other than atrial fibrillation;
- Bleeding diathesis or coagulopathy;
- Patients with rheumatic mitral valve disease, known severe mitral stenosis requiring surgical or percutaneous valve replacement, or existing mechanical valve prosthesis;
- Active infection with bacteremia;
Show all 16Show fewer
- Known hypersensitivity or contraindication to aspirin, clopidogrel, heparin, any device material or component (nickel titanium, PET, polypropylene), and/or contrast sensitivity;
- Prior atrial septal defect (ASD) or patient foramen ovale (PFO) surgical repair or implantation of closure device;
- Left atrial appendage is obliterated and surgical ligated;
- Underwent any cardiac or non-cardiac interventional or surgical procedure within 30 days prior to the procedure or planned to have the interventional or surgical procedure within 60 days after implant procedure (e.g., cardioversion, ablation, percutaneous coronary intervention, cataract surgery, etc.);
- Recent (within 90 days prior to procedure) stroke, transient ischemic attack, or myocardial infarction;
- New York Heart Association Class IV;
- Patients with severe renal failure (estimated glomerular filtration rate<30 ml/min/1.73m2);
- Known asymptomatic carotid artery disease with>70% diameter stenosis OR symptomatic carotid disease (>50% diameter stenosis with ipsilateral stroke or TIA). Subjects with prior carotid endarterectomy or carotid stent placement may be enrolled, provided that known diameter stenosis is <50%;
- Life expectancy is less than 1 year;
- Current participation in another investigational drug or device study.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Hong Kong1 site, 1 recruiting
- Recruiting
Prince of Wales Hospital, Chinese University of Hong Kong, HKSAR
Shatin
Kent CY So, Professor, 0852-3505-1518, Scy309@ha.org.hk
About this study
Official title: A First-in-Man (FIM) Study of the LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System for Patients With Non-Valvular Atrial Fibrillation
To evaluate the preliminary safety and feasibility of the LAmbreTM II Left Atrial Appendage Occluder and the Occluder Delivery System in patients with non-valvular atrial fibrillation who are at increased risk for stroke and systemic embolism.
Read the detailed description
Worldwide, atrial fibrillation (AF) is the most common cardiac arrhythmia in adults. The prevalence of AF gradually increases with age; its prevalence is 0.5% ~ 0.8% among 45 ~ 59 year-olds, 1.8% ~ 5.9% among 60 ~ 69 year-olds, and 6.7% ~ 17.9% among > 79 year-olds. Thromboembolic complications are the leading cause of death and disability in patients with AF, with ischemic stroke being the most common complication. AF significantly increases the risk of stroke by 3- to 5-fold due to thrombosis caused by abnormal atrial beat. The overall risk of ischemic stroke in patients with AF is 20% ~ 30%, and strokes due to atrial fibrillation account for 20% of all strokes.
Oral anticoagulation (OAC) is the standard of care in the management of non-valvular atrial fibrillation for stroke prevention and is recommended in the USA and European guidelines. However, the use of warfarin, a traditional oral anticoagulant, requires frequent and careful monitoring to ensure adequate anticoagulation as well as to prevent over-anticoagulation. This necessitates frequent laboratory blood tests to maintain the International Normalization Ratio (INR), a measure of the efficacy of the warfarin regimen, which can lead to patient non-adherence. Sub-therapeutic INR does not prevent systemic embolization, and supratherapeutic INR is a risk for haemorrhage. Moreover, the impact of interactions with other drugs, diet, narrow therapeutic window, and other reasons limit the use of warfarin. Several studies have shown that in clinical practice anticoagulation is given to less than 50% ~ 60% of patients with indications and discontinuation rates of warfarin approach 33% per year. Non-vitamin K antagonist oral anticoagulants (NOAC) have been shown to have a non-inferiority or superior effect in stroke reduction compared to warfarin without the need for routine laboratory monitoring. However, due to the high cost of NOACs and the lack of stable and effective antagonists, treatment discontinuation rates of up to 20% have been reported, and there is still an absolute risk of bleeding of 2% to 3% per year. A safe and effective alternative to anticoagulation for the stroke prevention in AF is needed, as the bleeding risk of anticoagulation and the presence of patient refusal/non-adherence/intolerance to long-term anticoagulation.
For a majority of patients with atrial fibrillation, it appears that thrombus formation would be located in the Left atrial appendage (LAA). Previous studies have suggested that more than 90% of thrombi in patients with non-valvular atrial fibrillation (NVAF) are located in the LAA. Therefore, surgical and percutaneous techniques to occlude the LAA could be a solution to reduce the risk of ischemic stroke for patients with AF. Surgical ligation of the LAA during the mitral valve surgery can reduce the risk of stroke, however, it is difficult to completely close the LAA by surgical ligation. Studies evaluating the incidence of incomplete ligation of the LAA during mitral valve surgery have shown that TEE-detected incidence of incomplete LAA ligation is about 36%. The WATCHMAN device (Boston Scientific, Natick, Massachusetts) is the most studied percutaneous left atrial appendage closure (LAAC) device and has shown that safety and efficacy are non-inferior to warfarin. In the current 2023 ACC/AHA/ACCP/HRS Guideline, percutaneous LAAC has been classified as a Class 2a indication for stroke prevention in patients with AF, a moderate to high risk of stroke, and a contraindication to long-term oral anticoagulation due to a non-reversible cause. However, the implantation procedure does have adverse effects which include serious pericardial effusion, procedure-related ischemic stroke, and device embolization. Due to the anatomical diversity of the LAA, certain patients are not candidates for this device.
The LAmbre™ Left Atrial Appendage Closure System, manufactured by Lifetech Scientific (Shenzhen) Co. Ltd., is the first generation of LAmbre LAAO device which is CE-marked and is current approved in Hong Kong Hospital Authority for regular clinical use. It consists of a LAA Occluder and a Delivery System and is a percutaneous transcatheter device intended to prevent thrombus embolization from the left atrial appendage in patients who have nonvalvular atrial fibrillation. This self-expanding LAA Occluder consists of an umbrella and a cover connected by a central waist. Although the first generation of LAmbre LAAO device is associated with high implantation success rate of 99.7% and a relatively low major procedure-related complication rate of 2.9%, to better match the challenging anatomy of the LAA and to further improve procedural safety, the first generation of LAmbre LAA O device has been upgraded.
The LAmbre™ II Left Atrial Appendage Occluder is the second generation of LAmbre LAAO device which is used with the Occluder Delivery System to seal off the left atrial appendage to prevent thrombus embolization from the left atrial appendage (LAA) in patients who have non-valvular atrial fibrillation. As an upgraded version of the LAmbre™ Left Atrial Appendage Occluder, the LAmbre™ II Left Atrial Appendage Occluder has a number of modifications including: the connection of Umbrella and Cover has been changed from the welded connection to the snap connection, which allows the Umbrella and Cover to be freely combined; the PET Membrane of the Cover has been added with a PC coating; the shape of the Cover has been changed from conical shape to disc shape; the structure of the end of U-shaped hook has been changed from a single beam structure to a diamond shape structure; the material of the Cover changed from 72 NiTi wires to 144 NiTi wires This study is a first-in-man study aimed at preliminary assessing the safety and feasibility of the LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System. The results of this study will be the basis for the design of subsequent confirmatory studies.
- Conditions
- Non-valvular Atrial Fibrillation (NVAF)
- Being tested
- LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System
- Keywords
- Lifetech, FIM study, LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System, LAmbre™ II, LAmbre™ II Left Atrial Appendage Occluder, Left Atrial Appendage Occluder, LAmbre™ II LAAO
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery SystemDevice
To evaluate the preliminary safety and feasibility of the LAmbreTM II Left Atrial Appendage Occluder and the Occluder Delivery System in patients with non-valvular atrial fibrillation who are at increased risk for stroke and systemic embolism.
| Study group | Role | What they receive |
|---|---|---|
| LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System | Experimental | Not described Receives: Device: LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System |
What is being measured
The primary outcome is the main question the study is designed to answer.
The primary effective endpoint is closure success
Defined as complete LAA closure or peri-device residual leak ≤ 3 mm measured by TEE.
Measured: 12 months post-procedure.
The primary safety endpoint is major peri-procedural complications
Including cardiac perforation, pericardial effusion with tamponade or requiring drainage, device embolization, death, ischemic stroke, systemic embolism, and major vascular complications occurring within 7 days following the implant procedure or by hospital discharge, whichever is later.
Measured: Within 7 days following the implant procedure or by hospital discharge
Secondary outcomes (11)
Major adverse events
Defined as death, stroke, systemic embolism, pericardial effusion with tamponade or requiring drainage, device embolization, and major bleeding (BARC defined 3 or 5)
Measured: Evaluated within 7 days following the implant procedure or by hospital discharge and 30 days and 3, 6, 12 months post-procedure
Closure success
Assessed by TEE or cardiac computed tomography
Measured: Evaluated at 30 days and 3, 6 months post-procedure
Rate of bleeding complications
Evaluated as major bleeding (BARC Type 3 or 5) and minor bleeding (BARC type 2)
Measured: Evaluated within 7 days following the implant procedure or by hospital discharge, 30 days and 3, 6, 12 months post-procedure
Cardiovascular death
(cardiovascular and/or unexplained cause)
Measured: Evaluated within 7 days following the implant procedure or by hospital discharge, 30 days and 3, 6, 12 months post-procedure
Rate of ischemic stroke and systemic embolization
Measured: Evaluated within 7 days following the implant procedure or by hospital discharge, 30 days and 3, 6, 12 months post-procedure
Technical success rate
Defined as successful delivery and release of study device with acceptable device position and stability, and closure success
Measured: Evaluated immediately after the procedure
Procedural success rate
Defined as technical success without major peri-procedural complications
Measured: Evaluated at 7 days following the implant procedure or by hospital discharge, whichever comes later
Device-related thrombosis
Defined as the detection of thrombus adherent to the left atrial side of the device by TEE or cardiac computed tomography
Measured: Evaluated at 30 days and 3, 6, 12 months post-procedure
Occluder Delivery System related complication
Measured: Evaluated immediately after the procedure and within 7 days following the implant procedure or by hospital discharge
Performance Assessment of the Occluder Delivery System
Including accuracy, flexibility, pushability, withdrawal of delivery system (Grade I-V, V represents the best).
Measured: Evaluated during the procedure
Performance Assessment of the Occluder Delivery System: Puncture success
Defined as the successful puncture of the oval fossa region of the interatrial septum under fluoroscopy or TEE guidance, without changing the puncture needle or puncture site. The delivery sheath and dilator are then successfully advanced into the left atrium.
Measured: Evaluated during the procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted4 Feb 2026
- Study start19 Jan 2026
- Primary completion31 Dec 2027 (estimated)
- Study completion1 Mar 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Non-valvular Atrial Fibrillation (NVAF)Studies of the same condition, open and under way.
- More trials run by Lifetech Scientific (Shenzhen) Co., Ltd.The sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 10 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Lifetech Scientific (Shenzhen) Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
- Investigators
- Kent CY So, Professor, Principal investigator, Prince of Wales Hospital, Chinese University of Hong Kong, HKSAR
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07385599
- Sponsor's protocol ID
- LT-TS-154-2025-01
- Status last verified
- Jun 2026
- First submitted
- 21 Jul 2025
- Last updated
- 10 Jun 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 10 Jun 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A First-in-Man (FIM) Study of the LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System for Patients With Non-Valvular Atrial Fibrillation
- ClinicalTrials.gov ID
- NCT07385599
- Acronym / sponsor ID
- LT-TS-154-2025-01
- Conditions
- Non-valvular Atrial Fibrillation (NVAF)
- Keywords
- Lifetech, FIM study, LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System, LAmbre™ II, LAmbre™ II Left Atrial Appendage Occluder, Left Atrial Appendage Occluder, LAmbre™ II LAAO
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 10 participants (estimated)
- Lead sponsor
- Lifetech Scientific (Shenzhen) Co., Ltd.Industry (pharma, biotech, devices)
- Study start
- 19 Jan 2026 (actual)
- Primary completion
- 31 Dec 2027 (estimated)
- Study completion
- 1 Mar 2028 (estimated)
- First posted
- 4 Feb 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
To evaluate the preliminary safety and feasibility of the LAmbreTM II Left Atrial Appendage Occluder and the Occluder Delivery System in patients with non-valvular atrial fibrillation who are at increased risk for stroke and systemic embolism.
Detailed description
Worldwide, atrial fibrillation (AF) is the most common cardiac arrhythmia in adults. The prevalence of AF gradually increases with age; its prevalence is 0.5% ~ 0.8% among 45 ~ 59 year-olds, 1.8% ~ 5.9% among 60 ~ 69 year-olds, and 6.7% ~ 17.9% among > 79 year-olds. Thromboembolic complications are the leading cause of death and disability in patients with AF, with ischemic stroke being the most common complication. AF significantly increases the risk of stroke by 3- to 5-fold due to thrombosis caused by abnormal atrial beat. The overall risk of ischemic stroke in patients with AF is 20% ~ 30%, and strokes due to atrial fibrillation account for 20% of all strokes.
Oral anticoagulation (OAC) is the standard of care in the management of non-valvular atrial fibrillation for stroke prevention and is recommended in the USA and European guidelines. However, the use of warfarin, a traditional oral anticoagulant, requires frequent and careful monitoring to ensure adequate anticoagulation as well as to prevent over-anticoagulation. This necessitates frequent laboratory blood tests to maintain the International Normalization Ratio (INR), a measure of the efficacy of the warfarin regimen, which can lead to patient non-adherence. Sub-therapeutic INR does not prevent systemic embolization, and supratherapeutic INR is a risk for haemorrhage. Moreover, the impact of interactions with other drugs, diet, narrow therapeutic window, and other reasons limit the use of warfarin. Several studies have shown that in clinical practice anticoagulation is given to less than 50% ~ 60% of patients with indications and discontinuation rates of warfarin approach 33% per year. Non-vitamin K antagonist oral anticoagulants (NOAC) have been shown to have a non-inferiority or superior effect in stroke reduction compared to warfarin without the need for routine laboratory monitoring. However, due to the high cost of NOACs and the lack of stable and effective antagonists, treatment discontinuation rates of up to 20% have been reported, and there is still an absolute risk of bleeding of 2% to 3% per year. A safe and effective alternative to anticoagulation for the stroke prevention in AF is needed, as the bleeding risk of anticoagulation and the presence of patient refusal/non-adherence/intolerance to long-term anticoagulation.
For a majority of patients with atrial fibrillation, it appears that thrombus formation would be located in the Left atrial appendage (LAA). Previous studies have suggested that more than 90% of thrombi in patients with non-valvular atrial fibrillation (NVAF) are located in the LAA. Therefore, surgical and percutaneous techniques to occlude the LAA could be a solution to reduce the risk of ischemic stroke for patients with AF. Surgical ligation of the LAA during the mitral valve surgery can reduce the risk of stroke, however, it is difficult to completely close the LAA by surgical ligation. Studies evaluating the incidence of incomplete ligation of the LAA during mitral valve surgery have shown that TEE-detected incidence of incomplete LAA ligation is about 36%. The WATCHMAN device (Boston Scientific, Natick, Massachusetts) is the most studied percutaneous left atrial appendage closure (LAAC) device and has shown that safety and efficacy are non-inferior to warfarin. In the current 2023 ACC/AHA/ACCP/HRS Guideline, percutaneous LAAC has been classified as a Class 2a indication for stroke prevention in patients with AF, a moderate to high risk of stroke, and a contraindication to long-term oral anticoagulation due to a non-reversible cause. However, the implantation procedure does have adverse effects which include serious pericardial effusion, procedure-related ischemic stroke, and device embolization. Due to the anatomical diversity of the LAA, certain patients are not candidates for this device.
The LAmbre™ Left Atrial Appendage Closure System, manufactured by Lifetech Scientific (Shenzhen) Co. Ltd., is the first generation of LAmbre LAAO device which is CE-marked and is current approved in Hong Kong Hospital Authority for regular clinical use. It consists of a LAA Occluder and a Delivery System and is a percutaneous transcatheter device intended to prevent thrombus embolization from the left atrial appendage in patients who have nonvalvular atrial fibrillation. This self-expanding LAA Occluder consists of an umbrella and a cover connected by a central waist. Although the first generation of LAmbre LAAO device is associated with high implantation success rate of 99.7% and a relatively low major procedure-related complication rate of 2.9%, to better match the challenging anatomy of the LAA and to further improve procedural safety, the first generation of LAmbre LAA O device has been upgraded.
The LAmbre™ II Left Atrial Appendage Occluder is the second generation of LAmbre LAAO device which is used with the Occluder Delivery System to seal off the left atrial appendage to prevent thrombus embolization from the left atrial appendage (LAA) in patients who have non-valvular atrial fibrillation. As an upgraded version of the LAmbre™ Left Atrial Appendage Occluder, the LAmbre™ II Left Atrial Appendage Occluder has a number of modifications including: the connection of Umbrella and Cover has been changed from the welded connection to the snap connection, which allows the Umbrella and Cover to be freely combined; the PET Membrane of the Cover has been added with a PC coating; the shape of the Cover has been changed from conical shape to disc shape; the structure of the end of U-shaped hook has been changed from a single beam structure to a diamond shape structure; the material of the Cover changed from 72 NiTi wires to 144 NiTi wires This study is a first-in-man study aimed at preliminary assessing the safety and feasibility of the LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System. The results of this study will be the basis for the design of subsequent confirmatory studies.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System | Experimental | Device: LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (7 listed)
- The patient age ≥18 years;
- The patient has documented paroxysmal, persistent, or permanent non-valvular atrial fibrillation;
- The patient has a CHA2DS2-VASc score of ≥ 2 in men and CHA2DS2-VASc score of ≥ 3 in women;
- The patient is recommended for oral anticoagulation therapy, but there is an appropriate rationale for seeking a non-pharmacologic alternative to oral anticoagulation;
- The patient is deemed suitable for LAA closure by the site investigator and a clinician not a part of the procedural team in the shared decision-making process, and this determination has been documented in the patient's medical record;
Key exclusion criteria (16 listed)
- Pregnant or nursing patients and those who plan pregnancy during the study period. Female patients of childbearing potential must have a negative pregnancy test (per site standard test) within 7 days prior to the index procedure;
- Patients with atrial fibrillation that is defined by a single occurrence, or that is transient or reversible (e.g., secondary to CABG, an interventional procedure, pneumonia, or hyperthyroidism);
- Patients who require long-term anticoagulation for a condition other than atrial fibrillation;
- Bleeding diathesis or coagulopathy;
- Patients with rheumatic mitral valve disease, known severe mitral stenosis requiring surgical or percutaneous valve replacement, or existing mechanical valve prosthesis;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery SystemTo evaluate the preliminary safety and feasibility of the LAmbreTM II Left Atrial Appendage Occluder and the Occluder Delivery System in patients with non-valvular atrial fibrillation who are at increased risk for stroke and systemic embolism. | Device | LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System |
Primary outcome
The primary effective endpoint is closure success
Time frame: 12 months post-procedure.
Defined as complete LAA closure or peri-device residual leak ≤ 3 mm measured by TEE.
The primary safety endpoint is major peri-procedural complications
Time frame: Within 7 days following the implant procedure or by hospital discharge
Including cardiac perforation, pericardial effusion with tamponade or requiring drainage, device embolization, death, ischemic stroke, systemic embolism, and major vascular complications occurring within 7 days following the implant procedure or by hospital discharge, whichever is later.
11 secondary outcomes
Major adverse events
Time frame: Evaluated within 7 days following the implant procedure or by hospital discharge and 30 days and 3, 6, 12 months post-procedure
Closure success
Time frame: Evaluated at 30 days and 3, 6 months post-procedure
Rate of bleeding complications
Time frame: Evaluated within 7 days following the implant procedure or by hospital discharge, 30 days and 3, 6, 12 months post-procedure
Cardiovascular death
Time frame: Evaluated within 7 days following the implant procedure or by hospital discharge, 30 days and 3, 6, 12 months post-procedure
Rate of ischemic stroke and systemic embolization
Time frame: Evaluated within 7 days following the implant procedure or by hospital discharge, 30 days and 3, 6, 12 months post-procedure
Technical success rate
Time frame: Evaluated immediately after the procedure
Procedural success rate
Time frame: Evaluated at 7 days following the implant procedure or by hospital discharge, whichever comes later
Device-related thrombosis
Time frame: Evaluated at 30 days and 3, 6, 12 months post-procedure
Occluder Delivery System related complication
Time frame: Evaluated immediately after the procedure and within 7 days following the implant procedure or by hospital discharge
Performance Assessment of the Occluder Delivery System
Time frame: Evaluated during the procedure
Performance Assessment of the Occluder Delivery System: Puncture success
Time frame: Evaluated during the procedure
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Jun 2026.
Related trials for Non-valvular Atrial Fibrillation (NVAF)
Active, not recruiting
Combined Pulsed-field Ablation (PFA) and Left Atrial Appendage Occlusion Using Watchman Flx or Amulet
Combined Pulsed-field Ablation (PFA)
Not yet recruiting
Shared Decision Making to Address Racial Disparities in Oral Anticoagulation in NVAF
Atrial Fibrillation
Recruiting
Comparison of LAA-Closure vs Oral Anticoagulation in Patients With NVAF and Status Post Intracranial Bleeding.
Intracranial Hemorrhages, Atrial Fibrillation (AF)
Enrolling by invitationObservational study
Precision Antithrombotic Therapy
Non-valvular Atrial Fibrillation (NVAF), Venous Thromboembolism (VTE)
Not yet recruiting
Stepwise vs Standard Anticoagulation for AF Patients Undergoing CIED Implantation (STEP-AF)
Non-valvular Atrial Fibrillation (NVAF), Thromboembolism
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Kent CY So, Professor principal investigator
Prince of Wales Hospital, Chinese University of Hong Kong, HKSAR
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing LAmbre™ II Left Atrial Appendage Occluder and Occluder Delivery System in people with Non-valvular Atrial Fibrillation (NVAF), run by Lifetech Scientific (Shenzhen) Co., Ltd. at 1 site in Hong Kong.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 7 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 10 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Hong Kong. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Kent CY So, Professor (0852-3505-1518, Scy309@ha.org.hk), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The primary effective endpoint is closure success (time frame: 12 months post-procedure.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Jun 2026.