AzTrials
AzTrials

Mandibular Angle FracturePhase 4NCT07390734

Patient Specific 3d Titanium Plate Versus Standard Two Mini Plates in the Fixation of Mandibular Angle Fractures (a Randomized Controlled Clinical Trial)

A Phase 4 study testing custom-made 3D titanium plates and standared two mini plates in people with Mandibular Angle Fracture, run by Alexandria University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To compare the effectiveness of custom-made (3D) titanium plates to standard two titanium mini plates in fixation of mandibular angle fracture. Read more about this study

Who is it for?
Ages 20 to 50 years
Conditions the study is for
Mandibular Angle Fracture
What is being tested?
custom-made 3D titanium plates and standared two mini plates
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
16 participants
Where
1 siteEgypt
Study dates
1 Jan 2025to 30 Apr 2026
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 50 years
  • All sexes
  • No healthy volunteers
  • Adult

Who may be able to join

  • Patients suffering from mandibular angle fracture indicated for open reduction and fixation.
  • Non infected mandibular angle fractures present less than two weeks. 3. Good oral hygiene.

Who cannot join

  • Medically compromised patients contradicting operation (ASA III, IV \& V).
  • Patients receiving radiotherapy or chemotherapy. 3- Bone diseases (Osteoporosis, Osteopetrosis, Osteomalacia…etc.) 4- Pathological fracture. 5- Old untreated fracture.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Faculty of dentistry, Alexandria university

    Alexandria, 21523

Other trials in Egypt

About this study

To compare the effectiveness of custom-made (3D) titanium plates to standard two titanium mini plates in fixation of mandibular angle fracture.

Read the detailed description

16 patients with mandibular angle fractures will be selected. In 8 fractures, custom-made three dimensional titanium plates will be used for fracture fixation (study group); while in the other 8, conventional two mini plates will be used (control group),via intra oral approach (combined with transbuccal approach) for both groups. Patients will be evaluated clinically, and radiographically (immediate and four months post operative) to evaluate the bone density at the fracture line.

Being tested
custom-made 3D titanium plates, standared two mini plates
Keywords
three dimensional plates, mandibular angle fracture, patient specific plate

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • custom-made 3D titanium platesDevice

    custom-made 3D titanium plates through intaoral and transbuccal approach .

  • standared two mini platesDevice

    internal fixation with standared two mini plates through intaoral and transbuccal approach.

Study groups in NCT07390734
Study groupRoleWhat they receive
patients with recent mandibular angle fractures managed with custom-made 3D titanium platesExperimentalpatients that will undergo internal fixation with custom-made 3D titanium plates through intaoral and transbuccal approach .
Receives: Device: custom-made 3D titanium plates
patients with recent mandibular angle fractures managed with standared two mini platesExperimentalpatient that will undergo internal fixation with standared two mini plates through intaoral and transbuccal approach.
Receives: Device: standared two mini plates

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Maximal mouth opening

    measurement of inter incisal distance between maxillary and mandibular central incisors.

    Measured: This will be assessed at 1, 7, 14, 30 days postoperatively.

Secondary outcomes (6)
  1. Post operative pain

    • Post operative pain This will be subjectively evaluated with a visual analogue scale (VAS) with values from 0 (no pain) to 10 (strongest pain).

    Measured: 3 months

  2. Radiographic evaluation for the assessment of mean bone density at the fracture line

    Mean bone density at the fracture line was assessed using Computed Tomography (CT) scan in Hounsfield Units (HU)

    Measured: Immediately postopreative and at 4 months

  3. Postoperative occlusion

    By checking the maximal inter-cuspal position (centric occlusion) to ensure proper occlusal relationship including molar relation, canine relation and midline centralization. Any occlusal disturbance including open bite or improper tooth contact will be noted.

    Measured: This will be assessed at 1, 7, 14, 30 days postoperatively.

  4. Edema

    determined using a measuring tape. Three measurements were made between 5 reference points: tragus, soft tissue pogonion, lateral corner of the eye, angle of the mandible, and outer corner of the mouth, preoperatively, and on the 1 ,7 ,14,30 postoperative days.

    Measured: This will be assessed at 1, 7, 14, 30 days postoperatively.

  5. Wound healing

    The sutured wounds will be examined for signs and symptoms of infection including swelling, redness, hotness, pus discharge, and pain in addition to observation for any manifestations of wound healing disturbance, as wound dehiscence and hardware exposure, and the wound will be assessed according to Landry et al. index

    Measured: the wound will be assessed aat 1, 7 and 14,30 days postoperatively.

  6. Operative time

    Time form start of fracture reduction to fixation measured in minutes

    Measured: intra-opreative

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Feb 2026
  2. Study start1 Jan 2025
  3. Primary completion30 Dec 2025
  4. Study completion30 Apr 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Randomized controlled clinical trial
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
16 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07390734
Sponsor's protocol ID
1023-01/2025
Status last verified
Jan 2026
First submitted
29 Jan 2026
Last updated
28 Sep 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing custom-made 3D titanium plates and standared two mini plates in people with Mandibular Angle Fracture, run by Alexandria University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 28 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Maximal mouth opening (time frame: This will be assessed at 1, 7, 14, 30 days postoperatively.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Sep 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.