Obstructive Sleep ApneaROADS-1NCT07397780
RPMO2 Oximeter Accuracy During Sleep 1 Trial
An observational study of Obstructive Sleep Apnea, run by ProSomnus Sleep Technologies at 1 site in United States.
Trial summary
The goal of this observational study is to validate the accuracy of the RPMO2 OSA Device's oxygen desaturation index in individuals with obstructive sleep apnea versus the gold standard, in-lab polysomnography. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Obstructive Sleep Apnea
- What is being tested?
- RPMO2 OSA Device
- Type of treatment
- Pill or oral medicine, Medical device
- How many people
- 30 participants
- Where
- 1 siteUnited States
- Study dates
- 22 Jan 2026to 30 Jul 2026
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Adults with obstructive sleep apnea
Who may be able to join
- Provision of signed and dated informed consent form
- Stated willingness to comply with all study procedures and availability for the duration of the study
- Male or female, aged 18 years or older
- Diagnosed with obstructive sleep apnea (per American Academy of Sleep Medicine's definition)
- Adequate dentition for oral appliance therapy
- Ability to refrain from the use of OSA therapy other than the study device for the week prior to the in-lab sleep study
Who cannot join
- Non-respiratory sleep disorders or environmental or personal factors that preclude the accuracy, acquisition, or interpretation of in-lab polysomnography
- Pregnancy
- In the opinion of the principal investigator, unsuitable for participation in the study
Trial locations and contacts
1 site in 1 country.
About this study
The goal of this observational study is to validate the accuracy of the RPMO2 OSA Device's oxygen desaturation index in individuals with obstructive sleep apnea versus the gold standard, in-lab polysomnography.
Participants will receive an RPMO2 OSA Device and complete one night in a sleep lab using the device in addition to the standard montage used for polysomnography.
Read the detailed description
Monitoring of physiologic variables indicative of the presence and status of chronic disease have proven to be of considerable value in the clinical management and improvement of therapeutic outcomes. For instance, positive airway pressure (PAP) devices used in the treatment of obstructive sleep apnea (OSA) and pulmonary diseases provide nightly monitoring of therapeutic pressures and pulmonary disturbances. Sleep-related declines in the oxyhemoglobin saturation of arterial blood (SaO2) are a common and important pathophysiological occurrence and are associated with cardiovascular incidences and decreased survival in patients with sleep apnea. As well, such nocturnal hypoxia displays substantial night-to-night variability in respiratory status during sleep. Thus, the need for a comfortable, accurate oximeter capable of multi-night monitoring seems undeniable. Nonetheless, standard pulse oximeters are not commonly used for multi-night monitoring of SaO2 as the currently available devices are cumbersome and disturb sleep. An important consideration is that nightly monitoring must be convenient and inexpensive, features not present in currently available oximeters. The accuracy of conventional oximeters can be compromised by factors such as movement, poor perfusion, impaired thermoregulation, and ambient light interference. Importantly, SpO2 readings have been shown to be overestimated in individuals with darker skin, potentially leading to increased incidence of occult hypoxemia.
ProSomnus Sleep Technologies (Pleasanton, CA, USA) has developed a novel buccal mucosal oximeter (RPMO2 OSA Device). The oximeter is encapsulated in an overlay of the maxillary dentition and uses the mucosa of the buccal vestibule behind the upper lip as the reflective tissue. This device is suitable for long-term nightly monitoring as it is comfortable and rechargeable. Additionally, the site of the oximeter sensor, the buccal mucosa, has the advantages of being highly vascular, relatively void of melanin, and protected from ambient light. The device has been validated in a controlled desaturation study per ISO 80601-2-61, in which arterial blood samples from healthy, awake volunteers were collected and analyzed using co-oximetry while volunteers were desaturated from ~97% to ~72% SaO2. The RPMO2 device met the accuracy requirements stipulated by the United Stated Food and Drug Administration for reflectance pulse oximeters, i.e., ARMS ± 3.5% for SpO2 and ARMS ± 3bpm for pulse rate.
The purpose of the present investigation is to validate the accuracy of the RPMO2 device in adults with OSA during sleep versus the gold standard, in-lab polysomnography.
- Conditions
- Obstructive Sleep Apnea
- Being tested
- RPMO2 OSA Device
- Keywords
- obstructive sleep apnea, oral appliance therapy, mandibular advancement, oximetry
- Medical subject headings
- Sleep Apnea, Obstructive
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
RPMO2 OSA DeviceDevice
Buccal mucosal oximeter embedded into the upper dental arch of an oral appliance used to treat obstructive sleep apnea.
What is being measured
The primary outcome is the main question the study is designed to answer.
Agreement between 4% oxygen desaturation index between study device and polysomnography
The primary study endpoint is the paired difference in 4% ODI between the study device and polysomnography (PSG). A paired design will be used to test agreement of 4% ODI as measured using the study device and manually scored PSG simultaneously. The Bland-Altman 95% limits of agreement (LoA) and their 95% confidence intervals (CI) for the LoA will be calculated. The maximum absolute value of the CIs will be compared to the maximum allowable difference. Agreement will be concluded if the maximum absolute value of the CIs is < 19.
Measured: 1 week
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Feb 2026
- Study start22 Jan 2026
- Primary completion30 May 2026 (estimated)
- Study completion30 Jul 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Obstructive Sleep ApneaStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 30 participants (estimated)
Sponsor and investigators
- Lead sponsor
- ProSomnus Sleep Technologies
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07397780
- Sponsor's protocol ID
- SP-008
- Acronym
- ROADS-1
- Status last verified
- Feb 2026
- First submitted
- 26 Jan 2026
- Last updated
- 19 Feb 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 19 Feb 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- RPMO2 Oximeter Accuracy During Sleep 1 Trial
- ClinicalTrials.gov ID
- NCT07397780
- Acronym / sponsor ID
- ROADS-1 / SP-008
- Conditions
- Obstructive Sleep Apnea
- Keywords
- obstructive sleep apnea, oral appliance therapy, mandibular advancement, oximetry
- Study type
- Observational
- Recruitment status
- Active, not recruiting
- Enrolment
- 30 participants (estimated)
- Lead sponsor
- ProSomnus Sleep TechnologiesIndustry (pharma, biotech, devices)
- Study start
- 22 Jan 2026 (actual)
- Primary completion
- 30 May 2026 (estimated)
- Study completion
- 30 Jul 2026 (estimated)
- First posted
- 9 Feb 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal of this observational study is to validate the accuracy of the RPMO2 OSA Device's oxygen desaturation index in individuals with obstructive sleep apnea versus the gold standard, in-lab polysomnography.
Participants will receive an RPMO2 OSA Device and complete one night in a sleep lab using the device in addition to the standard montage used for polysomnography.
Detailed description
Monitoring of physiologic variables indicative of the presence and status of chronic disease have proven to be of considerable value in the clinical management and improvement of therapeutic outcomes. For instance, positive airway pressure (PAP) devices used in the treatment of obstructive sleep apnea (OSA) and pulmonary diseases provide nightly monitoring of therapeutic pressures and pulmonary disturbances. Sleep-related declines in the oxyhemoglobin saturation of arterial blood (SaO2) are a common and important pathophysiological occurrence and are associated with cardiovascular incidences and decreased survival in patients with sleep apnea. As well, such nocturnal hypoxia displays substantial night-to-night variability in respiratory status during sleep. Thus, the need for a comfortable, accurate oximeter capable of multi-night monitoring seems undeniable. Nonetheless, standard pulse oximeters are not commonly used for multi-night monitoring of SaO2 as the currently available devices are cumbersome and disturb sleep. An important consideration is that nightly monitoring must be convenient and inexpensive, features not present in currently available oximeters. The accuracy of conventional oximeters can be compromised by factors such as movement, poor perfusion, impaired thermoregulation, and ambient light interference. Importantly, SpO2 readings have been shown to be overestimated in individuals with darker skin, potentially leading to increased incidence of occult hypoxemia.
ProSomnus Sleep Technologies (Pleasanton, CA, USA) has developed a novel buccal mucosal oximeter (RPMO2 OSA Device). The oximeter is encapsulated in an overlay of the maxillary dentition and uses the mucosa of the buccal vestibule behind the upper lip as the reflective tissue. This device is suitable for long-term nightly monitoring as it is comfortable and rechargeable. Additionally, the site of the oximeter sensor, the buccal mucosa, has the advantages of being highly vascular, relatively void of melanin, and protected from ambient light. The device has been validated in a controlled desaturation study per ISO 80601-2-61, in which arterial blood samples from healthy, awake volunteers were collected and analyzed using co-oximetry while volunteers were desaturated from ~97% to ~72% SaO2. The RPMO2 device met the accuracy requirements stipulated by the United Stated Food and Drug Administration for reflectance pulse oximeters, i.e., ARMS ± 3.5% for SpO2 and ARMS ± 3bpm for pulse rate.
The purpose of the present investigation is to validate the accuracy of the RPMO2 device in adults with OSA during sleep versus the gold standard, in-lab polysomnography.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Adults with obstructive sleep apnea
Key inclusion criteria (6 listed)
- Provision of signed and dated informed consent form
- Stated willingness to comply with all study procedures and availability for the duration of the study
- Male or female, aged 18 years or older
- Diagnosed with obstructive sleep apnea (per American Academy of Sleep Medicine's definition)
- Adequate dentition for oral appliance therapy
Key exclusion criteria (3 listed)
- Non-respiratory sleep disorders or environmental or personal factors that preclude the accuracy, acquisition, or interpretation of in-lab polysomnography
- Pregnancy
- In the opinion of the principal investigator, unsuitable for participation in the study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| RPMO2 OSA DeviceBuccal mucosal oximeter embedded into the upper dental arch of an oral appliance used to treat obstructive sleep apnea. | Device | – |
Primary outcome
Agreement between 4% oxygen desaturation index between study device and polysomnography
Time frame: 1 week
The primary study endpoint is the paired difference in 4% ODI between the study device and polysomnography (PSG). A paired design will be used to test agreement of 4% ODI as measured using the study device and manually scored PSG simultaneously. The Bland-Altman 95% limits of agreement (LoA) and their 95% confidence intervals (CI) for the LoA will be calculated. The maximum absolute value of the CIs will be compared to the maximum allowable difference. Agreement will be concluded if the maximum absolute value of the CIs is < 19.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Feb 2026.
- Individual participant dataSharing planned: No
Related trials for Obstructive Sleep Apnea
RecruitingObservational study
Development and Validation of a Multimodal Deep Learning Model Using Peripheral Oxygen Saturation and Ballistocardiography Signals for Predicting Apnea-Hypopnea Index in Obstructive Sleep Apnea
Obstructive Sleep Apnea
RecruitingPhase 3
A Study to Learn About the Monthly Dosing Study Medicine Called Berobenatide in Adults With Breathing Problems During Sleep and Overweight or Obesity Who Do Not Use a Breathing Machine (PAP) (VESPER-OSA 2)
Apnea, Sleep Disorders
Not yet recruitingPhase 2
Supplemental Oxygen for Sleep-Disordered Breathing in Adults With Chronic Opioid Use.
Sleep-disordered Breathing, Chronic Opioid Use
Recruiting
Nightly Wearable Monitoring During Home-Based Submental Electrical Stimulation for Obstructive Sleep Apnea
Obstructive Sleep Apnea
RecruitingPhase 1/2
DRonabinol Treatment of OSA
Obstructive Sleep Apnea
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Obstructive Sleep Apnea, run by ProSomnus Sleep Technologies at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: under way, not looking for participants, as of the sponsor's last update on 19 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Agreement between 4% oxygen desaturation index between study device and polysomnography (time frame: 1 week). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Feb 2026.