Derivo 2 Heal vs Derivo 2: In-Stent Stenosis After Flow Diversion

A study testing Coated Flow Diverter and Uncoated Flow Diverter in people with Aneurysm Cerebral, run by Universität des Saarlandes at 1 site in Germany.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this clinical trial is to learn whether a coated flow diverter leads to fewer in-stent narrowings (in-stent stenosis) than an otherwise identical uncoated flow diverter when used to treat intracranial aneurysms in routine clinical care. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Aneurysm Cerebral
What is being tested?
Coated Flow Diverter and Uncoated Flow Diverter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
21 participants
Where
1 siteGermany
Study dates
9 Sep 2021to 1 Apr 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adults aged ≥18 years
  • Unruptured, saccular aneurysm of the internal carotid artery (ICA) suitable for single-device flow diverter treatment
  • Availability of angiographic follow-up imaging at both 3 and 9 months

Who cannot join

  • Fusiform or dissecting aneurysms
  • Requirement for multiple flow diverter implantation
  • Previous treatment of the target aneurysm
  • Contraindications to dual antiplatelet therapy

Trial locations and contacts

1 site in 1 country.

Germany1 site
  • Saarland University Hospital

    Homburg, Saarland, 66421

Other trials in Germany

About this study

Official title: Derivo-ISS: A Prospective Randomized Study Comparing In-Stent Stenosis After Treatment With a Coated Versus Uncoated Flow Diverter (Derivo 2 Heal vs Derivo 2) for Intracranial ICA Aneurysms

The goal of this clinical trial is to learn whether a coated flow diverter leads to fewer in-stent narrowings (in-stent stenosis) than an otherwise identical uncoated flow diverter when used to treat intracranial aneurysms in routine clinical care. The main questions it aims to answer are:

Does the coated flow diverter reduce the rate and severity of in-stent stenosis compared with the uncoated flow diverter?

Read more

Are there differences in angiographic aneurysm occlusion and procedure-related complications between the two devices?

Researchers will compare treatment with the coated flow diverter (Derivo 2 heal) to the uncoated flow diverter (Derivo 2).

Participants will:

Receive endovascular treatment of their intracranial aneurysm with one of the two flow diverters assigned by randomization

Receive standard antiplatelet medication and follow-up imaging as part of routine care

Read the detailed description

This investigator-initiated, prospective, single-center randomized clinical study compared a surface-modified flow diverter (Derivo 2 heal; Acandis, Germany) with the corresponding uncoated device (Derivo 2) in the endovascular treatment of unruptured saccular internal carotid artery (ICA) aneurysms in routine clinical care. After confirmation of eligibility and written informed consent, patients were randomized in a 1:1 ratio to receive either the coated or uncoated flow diverter using a computer-generated permuted block randomization scheme with variable block sizes. Allocation concealment was ensured using sequentially numbered, opaque, sealed envelopes prepared by an independent study coordinator. Device diameter and length were selected according to a predefined institutional sizing standard based on angiographic measurements, independent of treatment allocation.

All procedures were performed under general anesthesia via a transfemoral approach using standard technique. No adjunctive coiling and no balloon angioplasty were performed. All participants received dual antiplatelet therapy with aspirin 100 mg/day and clopidogrel 75 mg/day initiated at least 3 days before the procedure and continued for at least 12 months; platelet function testing was not routinely performed.

Angiographic follow-up was scheduled at 3 and 9 months using digital subtraction angiography (DSA). In-stent stenosis (ISS) was defined as a segmental reduction of the contrast-filled parent vessel lumen within the stented segment compared with the immediate post-procedural angiogram. Because absolute calibration is limited in 2D projection imaging, ISS severity was assessed using a standardized ratio-based approach: the vessel diameter at the site of maximal stenosis was related to a reference segment in the petrous ICA, and the resulting ratio was compared with the corresponding ratio on the immediate post-procedural angiogram to quantify relative luminal narrowing over time. For descriptive purposes, high-grade ISS (>50%) was recorded. In addition, ISS was morphologically categorized as stenosis associated with visible stent deformation (e.g., focal flattening, incomplete expansion, segmental collapse, fish-mouth configuration) versus stenosis without visible deformation, the latter interpreted as predominantly related to intimal hyperplasia.

Aneurysm occlusion was assessed on follow-up DSA using the O'Kelly-Marotta (OKM) grading scale. Complete occlusion was predefined as OKM grade D (no residual aneurysm filling). Clinical events and adverse events were prospectively recorded during the periprocedural period and follow-up visits.

The primary objective was to compare the incidence and severity of ISS between the coated and uncoated flow diverter groups over time. Secondary objectives included comparison of aneurysm occlusion rates and evaluation of relationships between angiographic outcomes and device- or vessel-related factors.

Being tested
Coated Flow Diverter, Uncoated Flow Diverter
Keywords
Aneurysm, Flow Diverter, In-Stent-Stenosis
Medical subject headings
Intracranial Aneurysm, Aneurysm

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Coated Flow DiverterDevice

    A surface-modified intracranial flow diverter stent with an anti-thrombogenic coating (Derivo 2 heal, Acandis, Germany) used for endovascular treatment of unruptured intracranial internal carotid artery aneurysms. Device diameter and length are selected individually based on angiographic measurements according to institutional routine practice.

  • Uncoated Flow DiverterDevice

    The corresponding uncoated intracranial flow diverter stent (Derivo 2, Acandis, Germany) used for endovascular treatment of unruptured intracranial internal carotid artery aneurysms. Device diameter and length are selected individually based on angiographic measurements according to institutional routine practice.

Study groups in NCT07420179
Study groupRoleWhat they receive
Coated Flow Diverter (Derivo 2 heal)ExperimentalParticipants receive endovascular treatment of an unruptured intracranial internal carotid artery aneurysm using the coated flow diverter (Derivo 2 heal). Device diameter and length are selected individually based on angiographic measurements according to institutional routine practice. Periprocedural care and follow-up imaging are performed as part of standard care.
Receives: Device: Coated Flow Diverter
Uncoated Flow Diverter (Derivo 2)Active comparatorParticipants receive endovascular treatment of an unruptured intracranial internal carotid artery aneurysm using the uncoated flow diverter (Derivo 2). Device diameter and length are selected individually based on angiographic measurements according to institutional routine practice. Periprocedural care and follow-up imaging are performed as part of standard care.
Receives: Device: Uncoated Flow Diverter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. In-Stent Stenosis Severity (Ratio-Based Luminal Narrowing)

    In-stent stenosis (ISS) quantified on follow-up digital subtraction angiography (DSA) using a standardized ratio-based approach: the diameter at maximal stenosis within the stented segment relative to a reference segment (petrous ICA), compared with the corresponding ratio on the immediate post-procedural angiogram to derive relative luminal narrowing over time. Higher values indicate greater luminal narrowing (ISS severity).

    Measured: 3 months and 9 months after the procedure (DSA follow-up)

Secondary outcomes (3)
  1. High-Grade In-Stent Stenosis (>50%)

    Proportion of participants with high-grade in-stent stenosis defined as >50% luminal narrowing within the stented segment on follow-up DSA.

    Measured: 3 months and 9 months after the procedure

  2. Complete Aneurysm Occlusion (OKM Grade D)

    Complete angiographic occlusion on follow-up DSA defined as O'Kelly-Marotta (OKM) grade D (no residual aneurysm filling).

    Measured: 3 months and 9 months after the procedure

  3. Procedure-Related Complications

    Occurrence of periprocedural complications related to the endovascular treatment (e.g., thromboembolic events, hemorrhagic complications, device-related adverse events) recorded prospectively.

    Measured: Periprocedural period through 9 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Feb 2026
  2. Study start9 Sep 2021
  3. Primary completion1 Apr 2025
  4. Study completion1 Apr 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
21 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07420179
Sponsor's protocol ID
90/21
Status last verified
Feb 2026
First submitted
12 Feb 2026
Last updated
19 Feb 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data will not be shared due to local data protection regulations and because participant consent did not include public sharing of individual-level clinical and imaging data. Aggregated results will be reported in publications.

Publications

  • Garner M, Fries F, Haussmann A, Kettner M, Bachhuber A, Reith W, Yilmaz U. Recurrent reversible in-stent-stenosis after flow diverter treatment. Neuroradiology. 2023 Jul;65(7):1173-1177. doi: 10.1007/s00234-023-03144-7. Epub 2023 Mar 28.

    PubMed 36973452
  • Muhl-Benninghaus R, Haussmann A, Simgen A, Tomori T, Reith W, Yilmaz U. Transient in-stent stenosis: a common finding after flow diverter implantation. J Neurointerv Surg. 2019 Feb;11(2):196-199. doi: 10.1136/neurintsurg-2018-013975. Epub 2018 Jul 3.

    PubMed 29970620

Questions about this trial

What is this clinical trial studying?

A study testing Coated Flow Diverter and Uncoated Flow Diverter in people with Aneurysm Cerebral, run by Universität des Saarlandes at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

In-Stent Stenosis Severity (Ratio-Based Luminal Narrowing) (time frame: 3 months and 9 months after the procedure (DSA follow-up)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07420179, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Feb 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in