Left Ventricle FunctionTRANSLATENCT07455292
Phenotyping Left Ventricle Failure With Hemodynamic Biomarkers From 4D Flow Magnetic Resonance Imaging
A study testing Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacement in people with Left Ventricle Function and Transcatheter Aortic Valve Replacement (TAVR), run by IRCCS Policlinico S. Donato at 2 sites in Italy.
Trial summary
This study aims to enhance and streamline intracardiac 4D Flow magnetic resonance imaging (MRI) processing by increasing automation for the quantitative and systematic assessment of left ventricular (LV) dysfunction. The study is designed to achieve the following three objectives. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Left Ventricle Function, Transcatheter Aortic Valve Replacement (TAVR), Aortic Valve Stenosis
- What is being tested?
- Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacement
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 190 participants
- Where
- 2 sitesItaly
- Study dates
- 13 Oct 2025to 30 Sep 2026
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adult patients (age > 18 years old);
- Diagnosis of severe AS defined according to ESC guidelines with indication to TAVR;
- Severe aortic stenosis both in normal/high flow status and in low flow status;
- Signed informed written consent.
Who cannot join
- Contraindication to cardiac MRI due to previous implant with ferromagnetic components;
- Poor MRI quality impairing image post-processing;
- Claustrophobia;
- Unwilling to sign the informed consent.
Trial locations and contacts
2 sites in 1 country. Contact the study team or a site near you to ask about taking part.
Italy2 sites, 2 recruiting
- Recruiting
IRCCS Policlinico San Donato
San Donato Milanese, 20097
Giandomenico Disabato, MD, +390252774804, giandomenico.disabato@grupposandonato.it
Francesco Sturla, PhD, +390252774353, francesco.sturla@grupposandonato.it
- Recruiting
IRCCS Policlinico San Donato
San Donato Milanese, 20097
Francesco Sturla, MD, +390252774353, francesco.sturla@grupposandonato.it
Riccardo Gorla, PhD
About this study
This study aims to enhance and streamline intracardiac 4D Flow magnetic resonance imaging (MRI) processing by increasing automation for the quantitative and systematic assessment of left ventricular (LV) dysfunction. The study is designed to achieve the following three objectives.
The primary objective is to develop a convolutional neural network (CNN)-based deep learning model for the automatic segmentation of the LV endocardial contour throughout the cardiac cycle using intracavitary MRI data. To support model training, a dataset of LV endocardial wall segmentations will be generated from balanced steady-state free precession (bSSFP) images. A purpose-built retrospective MRI database of bSSFP images will be retrieved to accelerate training set creation.
Read more
The secondary objective is to develop a numerical framework for non-invasive MRI-based pressure-volume (PV) loop reconstruction and calculation of simplified hemodynamic force descriptors (HDFs). A prospective cohort of patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) will be enrolled. Pre-procedural non-contrast 4D Flow MRI will be acquired, and non-invasive MRI-derived PV loops will be quantitatively compared with invasive catheter-based PV loop measurements. In addition, simplified HDFs will be compared with 4D Flow-derived HDFs to assess their agreement and their potential to elucidate specific features of heart failure-related LV dysfunction.
The tertiary objective is to establish the foundation for a unified, standalone, and clinically deployable framework for comprehensive, automated, and clinician-friendly analysis of LV hemodynamics based on 4D Flow MRI. Internal testing, benchmarking, and structured evaluation by clinical end-users with prior 4D Flow MRI research experience will be conducted to collect feedback and guide further development and clinical translation.
Read the detailed description
The study includes a retrospective and a prospective arm, addressing methodological development, clinical validation, and translational implementation of advanced MRI-based analysis tools.
Within the retrospective arm, a database of short-axis cine balanced steady-state free precession (bSSFP) images of the LV will be retrieved retrospectively and anonymized prior to analysis. The dataset will be divided into a training set (approximately 75% of cases) and a test set (approximately 25%).
For all MRI datasets included in the training set, LV endocardial contours will be delineated throughout the cardiac cycle, employing semi-automatic segmentation tools (Medviso Segment) with manual corrections applied as necessary to ensure accuracy.
The training dataset, together with the corresponding ground-truth LV endocardial segmentations, will be used to train a deep learning convolutional neural network (CNN), e.g., a ResNet architecture, for the automatic delineation of LV endocardial contours from short-axis cine images.
The remaining test set will be used to evaluate the performance of the trained CNN. Automatically generated LV endocardial contours will be compared with the corresponding manual segmentations to benchmark segmentation accuracy and robustness.
As part of the prospective arm of the study, enrolled patients will undergo non-contrast 4D Flow MRI acquisition prior to the scheduled intervention for transcatheter aortic valve replacement (TAVR).
MRI examinations will be acquired on a 1.5 Tesla scanner (MAGNETOM Aera, Siemens Healthcare, Erlangen, Germany). Standard bSSFP cine sequences with retrospective ECG gating will be used to acquire short-axis and long-axis LV views (slice thickness 8 mm, no inter-slice gap, 30 reconstructed cardiac phases). In the same imaging session, 4D Flow MRI data will be acquired using a prototype time-resolved three-dimensional gradient echo sequence with three-directional velocity encoding. A parasagittal-oriented field of view covering the entire LV will be employed. Acquisitions will be performed during free breathing with retrospective ECG triggering and adaptive respiratory gating. Scan parameters will comply with the 2023 update of the 4D Flow Cardiovascular Magnetic Resonance Consensus Statement. No contrast agent will be administered. Non-invasive continuous blood pressure and relevant hemodynamic parameters will be also recorded from the finger arterial pressure waveform using a clinical-grade device (e.g., Finapres® NOVA).
During the TAVR procedure, simultaneous invasive blood pressure measurements will be obtained in the ascending aorta and in the LV using two pigtail catheters, both before and after valve implantation, as required by standard clinical practice during TAVR, thus without impacting on the clinical workflow.
No variations in prophylaxis or follow-up procedures are expected compared with standard clinical practice. Therefore, no additional physical, psychological, or social risks or direct benefits are associated with participation in the study.
Post-processing of 4D Flow MRI data will be performed using a dedicated workflow incorporating in-house software written in Matlab (The MathWorks Inc., Natick, MA, USA), based on prior experience. Processing steps will include correction for eddy currents and velocity aliasing. Intracavitary LV velocity fields will be extracted using both an in-house semi-automatic segmentation tool and the automated deep learning-based LV masking tool developed in the retrospective arm.
Extracted velocity fields will be used to evaluate LV blood flow energetics, including kinetic energy and viscous energy dissipation, flow component subdivision, intraventricular pressure gradients, and intracavitary flow-mediated hemodynamic forces (HDFs). The resulting HDF vectors will be decomposed into basal-apical, septal-lateral, and inferior-anterior components, and their root mean square (RMS) values will be computed over the cardiac cycle.
Non-invasive continuous blood pressure signals derived from finger arterial waveforms will be combined with MRI-derived LV volumes to estimate non-invasive LV pressure-volume (PV) loops using an established methodology. In parallel, invasive LV pressure data acquired during the TAVR procedure via pigtail catheter will be used to generate catheter-based PV loops. Non-invasive MRI-based PV loop parameters will be quantitatively compared with catheter-based measurements using clinically relevant LV indices.
Intracavitary pressure gradients will be computed from the Navier-Stokes equations to derive HDF vectors for each cardiac frame by integrating pressure gradients over the entire LV volume. HDF vectors will be projected onto three orthogonal anatomical directions (basal-apical, septal-lateral, inferior-anterior), and root mean square (RMS) values of each component calculated over the cardiac cycle. Simplified HDFs will be computed using a recently developed method that does not require 4D Flow MRI data and they will be systematically compared with standard 4D Flow MRI-based HDFs on a patient-specific basis. For validation purposes, both simplified and 4D Flow-derived HDFs will also be compared with corresponding measurements obtained using the prototype HDF tool available in the commercial Medis Suite MR software.
Conventional MRI-derived parameters routinely used to assess LV function, including end-diastolic volume, end-systolic volume, and global longitudinal strain, will also be collected.
Demographic variables (e.g., age and sex), relevant clinical characteristics, administered medical therapy, procedural TAVR data, and concomitant medications will be collected and anonymized prior to analysis.
No follow-up visits or assessments are planned as part of this study.
A standalone application for intracardiac 4D Flow MRI analysis will be designed following an incremental build development model. The process will focus on defining the system requirements specification (SyRS), software requirements specification (SRS), and overall software architecture.
A critical evaluation of existing state-of-the-art 4D Flow MRI workflows used in clinical research and of prototype tools available in commercial software (e.g., Medis Suite MR) will be conducted to identify strengths and limitations. Development will proceed through successive stages, with each stage implementing a specific functional component of the overall framework.
The standalone application will build upon existing in-house Matlab-based algorithms but will be implemented in a compiled programming language, allowing execution without requiring pre-installed software on the end-user's system. Development will be supported by a specialized consulting service.
A preliminary version of the standalone application will undergo internal testing, benchmarking, and structured evaluation by a small group of clinical end-users with prior experience in 4D Flow MRI research. Users will independently test the software on predefined use cases. Clinical feedback, criticisms, and suggestions for further development will be collected through structured questionnaires or interviews and used to guide subsequent refinement and clinical translation.
- Conditions
- Left Ventricle Function, Transcatheter Aortic Valve Replacement (TAVR), Aortic Valve Stenosis
- Being tested
- Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacement
- Keywords
- 4D Flow MRI
- Medical subject headings
- Aortic Valve Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacementDiagnostic test
Also called transcatheter aortic valve implantation, 4D Flow MRI, intracardic invasive pressure, non-invasive blood pressure
Cardiac magnetic resonance imaging, including standard cine imaging and non-contrast 4D Flow MRI acquisition. In the prospective phase, invasive and non-invasive hemodynamic signals routinely collected during the transcatheter aortic valve replacement procedure are recorded for research analysis. No additional procedures beyond standard clinical practice are required.
This is a low-intervention interventional study in which all imaging acquisitions and hemodynamic measurements are performed according to standard clinical practice, with no modification of diagnostic or therapeutic pathways.
| Study group | Role | What they receive |
|---|---|---|
| TRANSLATE Study Population | Other | The retrospective phase includes adult patients who previously underwent clinically indicated cardiac MRI for left ventricular functional assessment. The prospective phase includes patients with severe aortic stenosis undergoing transcatheter aortic valve replacement, who undergo additional non-contrast 4D Flow MRI and standard invasive hemodynamic measurements as part of routine clinical care. Data from both phases are used for development and validation of automated MRI-based analysis methods. Receives: Diagnostic Test: Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacement |
What is being measured
The primary outcome is the main question the study is designed to answer.
Accuracy of Automatic Left Ventricular Endocardial Segmentation
Accuracy of a convolutional neural network (CNN)-based model for automatic delineation of the left ventricular (LV) endocardial contour from short-axis cine balanced steady-state free precession (bSSFP) MRI images throughout the cardiac cycle. Automatically generated contours will be compared with expert manual segmentations (ground truth). Segmentation performance will be quantified using the Dice Similarity Index (DICE) and Hausdorff Distance (HD). Inter- and intra-operator variability of manual segmentation and agreement between manual and automatic contours will also be assessed using Bland-Altman analysis.
Measured: Completion of the retrospective analysis of cardiac MRI datasets (6 months)
Secondary outcomes (4)
Agreement Between Non-Invasive MRI-Based and Invasive Pressure-Volume Loop Parameters
Quantitative agreement between non-invasive MRI-derived left ventricular pressure-volume (PV) loop parameters and invasive catheter-based PV loop measurements acquired during the transcatheter aortic valve replacement (TAVR) procedure. Agreement and correlation will be assessed for clinically relevant LV parameters using correlation analysis and limits of agreement.
Measured: Up to 1 week after TAVR
Agreement Between Simplified and 4D Flow MRI-Based Hemodynamic Forces
Level of agreement and correlation between simplified hemodynamic force descriptors (HDFs) and HDFs calculated using standard intracardiac 4D Flow MRI-based analysis (reference standard). Comparisons will be performed for basal-apical, septal-lateral, and inferior-anterior force components using correlation analysis and Bland-Altman methods. Validation will also include comparison with HDF measurements obtained using a commercial prototype software tool.
Measured: Up to 1 week after TAVR
Correlation Between Hemodynamic Forces and LV Volumes
Correlation between LV hemodynamic forces (quantified using 4D Flow MRI and a simplified cine MRI-based method) and LV volumes, namely LV end-diastolic volume (LVEDV, expressed in ml) and LV end-systolic volume (LVESV, expressed in ml). Separate correlations will be calculated for LVEDV and LVESV, respectively.
Measured: Up to 1 week after TAVR
Correlation Between Hemodynamic Forces and LV Global Longitudinal and Circumferential Strain
Correlation between LV hemodynamic forces (quantified using 4D Flow MRI and a simplified cine MRI-based method) and LV endocardial parameters of deformation, namely global longitudinal strain (GLS) and global circumferential strain (GCS). Strain values will be expressed as percentage (%) deformation with separate correlations calculated for GLS and GCS, respectively.
Measured: Up to 1 week after TAVR
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Mar 2026
- Study start13 Oct 2025
- Primary completion30 Sep 2026 (estimated)
- Study completion30 Sep 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Left Ventricle FunctionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Arm description (retrospective and prospective phases): * retrospective phase includes adult patients who previously underwent clinically indicated cardiac MRI for LV functional assessment; * prospective phase includes patients with severe aortic stenosis undergoing TAVR, who undergo additional non-contrast 4D Flow MRI and standard invasive hemodynamic measurements as part of routine clinical care. Approximately 150 participants will be included in the retrospective phase and up to 40 participants i Intervention Description (prospective phase, low-risk and observational in nature): * cardiac magnetic resonance imaging, including standard cine imaging and non-contrast 4D Flow MRI acquisition; * invasive and non-invasive hemodynamic signals routinely collected during TAVR procedure are recorded for research analys. .
- Masking
- None (open label)
- Enrolment
- 190 participants (estimated)
Sponsor and investigators
- Lead sponsor
- IRCCS Policlinico S. Donato
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Giandomenico Disabato, MD, Principal investigator, IRCCS Policlinico S. Donato
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07455292
- Sponsor's protocol ID
- TRANSLATE
- Acronym
- TRANSLATE
- Status last verified
- Jan 2026
- First submitted
- 20 Feb 2026
- Last updated
- 6 Mar 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 6 Mar 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Phenotyping Left Ventricle Failure With Hemodynamic Biomarkers From 4D Flow Magnetic Resonance Imaging
- ClinicalTrials.gov ID
- NCT07455292
- Acronym / sponsor ID
- TRANSLATE / TRANSLATE
- Conditions
- Left Ventricle Function, Transcatheter Aortic Valve Replacement (TAVR), Aortic Valve Stenosis
- Keywords
- 4D Flow MRI
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 190 participants (estimated)
- Lead sponsor
- IRCCS Policlinico S. DonatoUniversity, hospital or other
- Study start
- 13 Oct 2025 (actual)
- Primary completion
- 30 Sep 2026 (estimated)
- Study completion
- 30 Sep 2026 (estimated)
- First posted
- 6 Mar 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study aims to enhance and streamline intracardiac 4D Flow magnetic resonance imaging (MRI) processing by increasing automation for the quantitative and systematic assessment of left ventricular (LV) dysfunction. The study is designed to achieve the following three objectives.
The primary objective is to develop a convolutional neural network (CNN)-based deep learning model for the automatic segmentation of the LV endocardial contour throughout the cardiac cycle using intracavitary MRI data. To support model training, a dataset of LV endocardial wall segmentations will be generated from balanced steady-state free precession (bSSFP) images. A purpose-built retrospective MRI database of bSSFP images will be retrieved to accelerate training set creation.
The secondary objective is to develop a numerical framework for non-invasive MRI-based pressure-volume (PV) loop reconstruction and calculation of simplified hemodynamic force descriptors (HDFs). A prospective cohort of patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) will be enrolled. Pre-procedural non-contrast 4D Flow MRI will be acquired, and non-invasive MRI-derived PV loops will be quantitatively compared with invasive catheter-based PV loop measurements. In addition, simplified HDFs will be compared with 4D Flow-derived HDFs to assess their agreement and their potential to elucidate specific features of heart failure-related LV dysfunction.
The tertiary objective is to establish the foundation for a unified, standalone, and clinically deployable framework for comprehensive, automated, and clinician-friendly analysis of LV hemodynamics based on 4D Flow MRI. Internal testing, benchmarking, and structured evaluation by clinical end-users with prior 4D Flow MRI research experience will be conducted to collect feedback and guide further development and clinical translation.
Detailed description
The study includes a retrospective and a prospective arm, addressing methodological development, clinical validation, and translational implementation of advanced MRI-based analysis tools.
Within the retrospective arm, a database of short-axis cine balanced steady-state free precession (bSSFP) images of the LV will be retrieved retrospectively and anonymized prior to analysis. The dataset will be divided into a training set (approximately 75% of cases) and a test set (approximately 25%).
For all MRI datasets included in the training set, LV endocardial contours will be delineated throughout the cardiac cycle, employing semi-automatic segmentation tools (Medviso Segment) with manual corrections applied as necessary to ensure accuracy.
The training dataset, together with the corresponding ground-truth LV endocardial segmentations, will be used to train a deep learning convolutional neural network (CNN), e.g., a ResNet architecture, for the automatic delineation of LV endocardial contours from short-axis cine images.
The remaining test set will be used to evaluate the performance of the trained CNN. Automatically generated LV endocardial contours will be compared with the corresponding manual segmentations to benchmark segmentation accuracy and robustness.
As part of the prospective arm of the study, enrolled patients will undergo non-contrast 4D Flow MRI acquisition prior to the scheduled intervention for transcatheter aortic valve replacement (TAVR).
MRI examinations will be acquired on a 1.5 Tesla scanner (MAGNETOM Aera, Siemens Healthcare, Erlangen, Germany). Standard bSSFP cine sequences with retrospective ECG gating will be used to acquire short-axis and long-axis LV views (slice thickness 8 mm, no inter-slice gap, 30 reconstructed cardiac phases). In the same imaging session, 4D Flow MRI data will be acquired using a prototype time-resolved three-dimensional gradient echo sequence with three-directional velocity encoding. A parasagittal-oriented field of view covering the entire LV will be employed. Acquisitions will be performed during free breathing with retrospective ECG triggering and adaptive respiratory gating. Scan parameters will comply with the 2023 update of the 4D Flow Cardiovascular Magnetic Resonance Consensus Statement. No contrast agent will be administered. Non-invasive continuous blood pressure and relevant hemodynamic parameters will be also recorded from the finger arterial pressure waveform using a clinical-grade device (e.g., Finapres® NOVA).
During the TAVR procedure, simultaneous invasive blood pressure measurements will be obtained in the ascending aorta and in the LV using two pigtail catheters, both before and after valve implantation, as required by standard clinical practice during TAVR, thus without impacting on the clinical workflow.
No variations in prophylaxis or follow-up procedures are expected compared with standard clinical practice. Therefore, no additional physical, psychological, or social risks or direct benefits are associated with participation in the study.
Post-processing of 4D Flow MRI data will be performed using a dedicated workflow incorporating in-house software written in Matlab (The MathWorks Inc., Natick, MA, USA), based on prior experience. Processing steps will include correction for eddy currents and velocity aliasing. Intracavitary LV velocity fields will be extracted using both an in-house semi-automatic segmentation tool and the automated deep learning-based LV masking tool developed in the retrospective arm.
Extracted velocity fields will be used to evaluate LV blood flow energetics, including kinetic energy and viscous energy dissipation, flow component subdivision, intraventricular pressure gradients, and intracavitary flow-mediated hemodynamic forces (HDFs). The resulting HDF vectors will be decomposed into basal-apical, septal-lateral, and inferior-anterior components, and their root mean square (RMS) values will be computed over the cardiac cycle.
Non-invasive continuous blood pressure signals derived from finger arterial waveforms will be combined with MRI-derived LV volumes to estimate non-invasive LV pressure-volume (PV) loops using an established methodology. In parallel, invasive LV pressure data acquired during the TAVR procedure via pigtail catheter will be used to generate catheter-based PV loops. Non-invasive MRI-based PV loop parameters will be quantitatively compared with catheter-based measurements using clinically relevant LV indices.
Intracavitary pressure gradients will be computed from the Navier-Stokes equations to derive HDF vectors for each cardiac frame by integrating pressure gradients over the entire LV volume. HDF vectors will be projected onto three orthogonal anatomical directions (basal-apical, septal-lateral, inferior-anterior), and root mean square (RMS) values of each component calculated over the cardiac cycle. Simplified HDFs will be computed using a recently developed method that does not require 4D Flow MRI data and they will be systematically compared with standard 4D Flow MRI-based HDFs on a patient-specific basis. For validation purposes, both simplified and 4D Flow-derived HDFs will also be compared with corresponding measurements obtained using the prototype HDF tool available in the commercial Medis Suite MR software.
Conventional MRI-derived parameters routinely used to assess LV function, including end-diastolic volume, end-systolic volume, and global longitudinal strain, will also be collected.
Demographic variables (e.g., age and sex), relevant clinical characteristics, administered medical therapy, procedural TAVR data, and concomitant medications will be collected and anonymized prior to analysis.
No follow-up visits or assessments are planned as part of this study.
A standalone application for intracardiac 4D Flow MRI analysis will be designed following an incremental build development model. The process will focus on defining the system requirements specification (SyRS), software requirements specification (SRS), and overall software architecture.
A critical evaluation of existing state-of-the-art 4D Flow MRI workflows used in clinical research and of prototype tools available in commercial software (e.g., Medis Suite MR) will be conducted to identify strengths and limitations. Development will proceed through successive stages, with each stage implementing a specific functional component of the overall framework.
The standalone application will build upon existing in-house Matlab-based algorithms but will be implemented in a compiled programming language, allowing execution without requiring pre-installed software on the end-user's system. Development will be supported by a specialized consulting service.
A preliminary version of the standalone application will undergo internal testing, benchmarking, and structured evaluation by a small group of clinical end-users with prior experience in 4D Flow MRI research. Users will independently test the software on predefined use cases. Clinical feedback, criticisms, and suggestions for further development will be collected through structured questionnaires or interviews and used to guide subsequent refinement and clinical translation.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Arm description (retrospective and prospective phases): * retrospective phase includes adult patients who previously underwent clinically indicated cardiac MRI for LV functional assessment; * prospective phase includes patients with severe aortic stenosis undergoing TAVR, who undergo additional non-contrast 4D Flow MRI and standard invasive hemodynamic measurements as part of routine clinical care. Approximately 150 participants will be included in the retrospective phase and up to 40 participants i Intervention Description (prospective phase, low-risk and observational in nature): * cardiac magnetic resonance imaging, including standard cine imaging and non-contrast 4D Flow MRI acquisition; * invasive and non-invasive hemodynamic signals routinely collected during TAVR procedure are recorded for research analys. .
| Arm | Type | Receives |
|---|---|---|
| TRANSLATE Study Population | Other | Diagnostic Test: Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacementThe retrospective phase includes adult patients who previously underwent clinically indicated cardiac MRI for left ventricular functional assessment. The prospective phase includes patients with severe aortic stenosis undergoing transcatheter aortic valve replacement, who undergo additional non-contrast 4D Flow MRI and standard invasive hemodynamic measurements as part of routine clinical care. Data from both phases are used for development and validation of automated MRI-based analysis methods. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Adult patients (age > 18 years old);
- Diagnosis of severe AS defined according to ESC guidelines with indication to TAVR;
- Severe aortic stenosis both in normal/high flow status and in low flow status;
- Signed informed written consent.
Key exclusion criteria (4 listed)
- Contraindication to cardiac MRI due to previous implant with ferromagnetic components;
- Poor MRI quality impairing image post-processing;
- Claustrophobia;
- Unwilling to sign the informed consent.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacementAlso: transcatheter aortic valve implantation, 4D Flow MRI, intracardic invasive pressure, non-invasive blood pressureCardiac magnetic resonance imaging, including standard cine imaging and non-contrast 4D Flow MRI acquisition. In the prospective phase, invasive and non-invasive hemodynamic signals routinely collected during the transcatheter aortic valve replacement procedure are recorded for research analysis. No additional procedures beyond standard clinical practice are required. This is a low-intervention interventional study in which all imaging acquisitions and hemodynamic measurements are performed according to standard clinical practice, with no modification of diagnostic or therapeutic pathways. | Diagnostic test | TRANSLATE Study Population |
Primary outcome
Accuracy of Automatic Left Ventricular Endocardial Segmentation
Time frame: Completion of the retrospective analysis of cardiac MRI datasets (6 months)
Accuracy of a convolutional neural network (CNN)-based model for automatic delineation of the left ventricular (LV) endocardial contour from short-axis cine balanced steady-state free precession (bSSFP) MRI images throughout the cardiac cycle. Automatically generated contours will be compared with expert manual segmentations (ground truth). Segmentation performance will be quantified using the Dice Similarity Index (DICE) and Hausdorff Distance (HD). Inter- and intra-operator variability of manual segmentation and agreement between manual and automatic contours will also be assessed using Bland-Altman analysis.
4 secondary outcomes
Agreement Between Non-Invasive MRI-Based and Invasive Pressure-Volume Loop Parameters
Time frame: Up to 1 week after TAVR
Agreement Between Simplified and 4D Flow MRI-Based Hemodynamic Forces
Time frame: Up to 1 week after TAVR
Correlation Between Hemodynamic Forces and LV Volumes
Time frame: Up to 1 week after TAVR
Correlation Between Hemodynamic Forces and LV Global Longitudinal and Circumferential Strain
Time frame: Up to 1 week after TAVR
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Mar 2026.
Related trials for Left Ventricle Function
Not yet recruitingObservational study
Preoperative Gastric Ultrasound and Left Ventricular Function in Coronary Artery Bypass Surgery
Coronary Artery Disease, Left Ventricular Systolic Dysfunction
RecruitingPhase 3
A Study to Test Whether Vicadrostat (BI 690517) in Combination With Empagliflozin Helps People With Heart Failure and a Weak Pumping Function of the Left Side of the Heart
Heart Failure
Recruiting
Resistance Exercise With Blood Flow Restriction by Vascular Occlusion on Myocardial Function in Heart Failure With Reduced Ejection Fraction
Heart Failure, Ventricular Function, Left
RecruitingPhase 3
Cardiac Stem/Progenitor Cell Infusion in Univentricular Physiology (APOLLON Trial)
Hypoplastic Left Heart Syndrome, Single Ventricle
Not yet recruitingObservational study
Evaluation of the UltraTrac System as a Non-Invasive Monitor of Hemodynamic Parameters
Hemodynamic Monitoring
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Giandomenico Disabato, MD principal investigator
IRCCS Policlinico S. Donato
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Cardiac MRI with 4D Flow acquisition and invasive signal routinely collected during transcatheter aortic valve replacement in people with Left Ventricle Function and Transcatheter Aortic Valve Replacement (TAVR), run by IRCCS Policlinico S. Donato at 2 sites in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 6 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Giandomenico Disabato, MD (+390252774804, giandomenico.disabato@grupposandonato.it), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Accuracy of Automatic Left Ventricular Endocardial Segmentation (time frame: Completion of the retrospective analysis of cardiac MRI datasets (6 months)). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Mar 2026.