DysphagiaNCT07475091

Standardizing Swallow Pressure Measurements

A study testing Laborie LMT Pharyngeal System (3.7 mm catheter) and Medtronic ManoScan ESO HRM System (4.2 mm catheter) in people with Dysphagia, run by University of Wisconsin, Madison at 1 site in United States.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

This study aims to directly compare and contrast swallowing pressure and impedance measurements obtained from two high-resolution manometry (HRM) systems: the Laborie LMT Pharyngeal System and the Medtronic ManoScan ESO HRM System in healthy adult volunteers. Read more about this study

Who is it for?
Ages 18 to 99 yearsHealthy volunteers can take part
Conditions the study is for
Dysphagia
What is being tested?
Laborie LMT Pharyngeal System (3.7 mm catheter) and Medtronic ManoScan ESO HRM System (4.2 mm catheter)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
1 siteUnited States
Study dates
Oct 2026to Sep 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 99 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • without known swallowing disorders

Who cannot join

  • Known swallowing disorder
  • Allergy to topical anesthetic
  • Allergy to food relevant to study participation (e.g. lactose intolerance)
  • Inability to follow direction or remain calm during the experiment.

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Suzan Abdelhalim, MD contact

608-265-2470

abdelhalim@surgery.wisc.edu

United States1 site
  • University of Wisconsin

    Madison, Wisconsin, 53792

Other trials in United States

About this study

Official title: Pharyngeal High Resolution Manometry Standardization of Metrics

This study aims to directly compare and contrast swallowing pressure and impedance measurements obtained from two high-resolution manometry (HRM) systems: the Laborie LMT Pharyngeal System and the Medtronic ManoScan ESO HRM System in healthy adult volunteers. The primary objective is to determine how differences in catheter diameter, sensor configuration, and acquisition platforms influence measurement outcomes. Twenty-five healthy adults will participate in a single, approximately 2-hour visit; the study will be open for one year for data collection and two years for data analysis.

Read the detailed description

The primary objective is to obtain, compare, and contrast directly the measured swallow between the Laborie Pharyngeal HRM impedance system with the 3.7 mm catheter and the Medtronic HRM impedance system with the 4.2 mm catheter in the same setting with normal healthy volunteers.

Conditions
Dysphagia
Being tested
Laborie LMT Pharyngeal System (3.7 mm catheter), Medtronic ManoScan ESO HRM System (4.2 mm catheter)
Keywords
pharyngeal pressure events, swallowing, measurement, diagnosis
Medical subject headings
Deglutition Disorders, Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Laborie LMT Pharyngeal System (3.7 mm catheter)Device

    Also called Laborie HRM impedance system, Laborie Solar™ GI HRM Solid-State, Trolley System (G3-9), Laborie Solid State HRIM Catheter (K83659-E-1820-D)

    The Solar GI HRM system is intended to record, store, view, and analyze pressure, impedance, EMG, swallow and respiration, and various auxiliary input device data online anywhere in the gastrointestinal tract (pharynx; esophagus; stomach; duodenum; sphincter of Oddi; small bowel; colon and anorectal area, including rectum and pelvic floor) to assist in the diagnosis and evaluation of gastrointestinal and swallowing disorders. Used with 3.7 mm catheter.

  • Medtronic ManoScan ESO HRM System (4.2 mm catheter)Device

    Also called Medtronic HRM impedance system, Medtronic ManoScan™ ESO high resolution manometry system, Medtronic ManoScan360 HRM catheter

    The ManoScan™ ESO high resolution manometry system enables full evaluation of the motor functions of the esophagus. The system provides useful information to support diagnosis of conditions like dysphagia, achalasia, and hiatal hernia. A 36-channel circumferential solid-state catheter with 4.2 mm diameter, 1.0 cm spacing between adjacent sensors.

Study groups in NCT07475091
Study groupRoleWhat they receive
Laborie then MedtronicExperimentalThis study will include a data collection session that involves swallowing tasks during HRM.
Receives: Device: Laborie LMT Pharyngeal System (3.7 mm catheter); Device: Medtronic ManoScan ESO HRM System (4.2 mm catheter)
Medtronic then LaborieExperimentalThis study will include a data collection session that involves swallowing tasks during HRM.
Receives: Device: Laborie LMT Pharyngeal System (3.7 mm catheter); Device: Medtronic ManoScan ESO HRM System (4.2 mm catheter)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Base of tongue pressure

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  2. Hypopharyngeal peak pressure

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  3. Pharyngeal Contractile Integral (PhCI)

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  4. Pressure rise time

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  5. Contractile front velocity

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  6. Upper Esophageal Sphincter (UES) resting pressure

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  7. UES peak contraction pressure

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  8. UES relaxation nadir pressure

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  9. UES relaxation duration

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  10. Nadir impedance

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  11. Bolus presence time

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  12. Flow interval

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  13. Pressure-flow index component

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  14. Timing relationships (onset-to-peak intervals)

    Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.

    Measured: data collected during 1 study visit (up to 2 hours)

  15. Construction of Spatial pressure distribution maps

    Multi-level modeling for repeated measures across bolus types, volumes, and repetitions. Sensor-level and region-level analyses (BOT, hypopharynx, UES). Agreement thresholds and bias definitions added to facilitate interpretability and ensure clarity for cross-platform comparison. Map layers will be summarized as a proxy for this measure.

    Measured: data collected during 1 study visit (up to 2 hours)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Mar 2026
  2. Study startOct 2026 (estimated)
  3. Primary completionSep 2027 (estimated)
  4. Study completionSep 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Crossover
Model description
Each participant will complete two HRM procedures in a randomized cross-over design with a 1:1 allocation to determine the order of catheter use
Masking
None (open label)
Enrolment
25 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07475091
Sponsor's protocol ID
2025-1642
Other IDs
SMPH | Otolaryngology, Protocol Version 4/28/26
Status last verified
Aug 2026
First submitted
11 Mar 2026
Last updated
29 Sep 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Laborie LMT Pharyngeal System (3.7 mm catheter) and Medtronic ManoScan ESO HRM System (4.2 mm catheter) in people with Dysphagia, run by University of Wisconsin, Madison at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 29 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Suzan Abdelhalim, MD (608-265-2470, abdelhalim@surgery.wisc.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Base of tongue pressure (time frame: data collected during 1 study visit (up to 2 hours)). The study lists 15 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Sep 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in