Abdominal Aortic AneurysmPOWERNCT07476196
Poland-Italy Aortic Research Bridge Real World Registry
An observational study of Abdominal Aortic Aneurysm, run by American Heart of Poland at 26 sites in 2 countries.
Trial summary
Objective To pragmatically collect and analyze patient-level clinical, procedural, and outcome data from participating centers in Italy and Poland on the use of the PERCUTEK Tycheseal™ stent-graft system for the endovascular repair of abdominal aortic aneurysms. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Abdominal Aortic Aneurysm
- How many people
- 200 participants
- Where
- 26 sitesin 2 countries
- Study dates
- 1 Mar 2026to 31 Mar 2030
- How long will I take part?
- 24 Months
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients with abdominal aortic aneurysm
Who may be able to join
None listed.
Who cannot join
- Anatomical unsuitability
- Subject has a life expectancy < 1 year
- Circumferential thrombus in neck
- Ruptured aneurysm
- Renal arteries from aneurysm sac
- Dominant IMA with obstructed visceral vessels
Show all 12Show fewer
- Internal iliac artery aneurysms (unless pre-treated)
- Subject has a known contraindication dual antiplatelets therapy or contrast media,
- Selected patients with chronic kidney failure (CKF) can undergo EVAR using standard contrast or CO2 as contrast agent.
- Previous aortoiliac surgery or EVAR
- Recent stroke/MI (< 3 months)
- Allergy to device materials
Trial locations and contacts
26 sites in 2 countries. Contact the study team or a site near you to ask about taking part.
26 sites in 2 countries
Poland21 sites, 21 recruiting
- Recruiting
Uniwersytecki Szpital Kliniczny w Białymstoku
Bialystok
Jerzy Głowiński, Prof., jglow@wp.pl
- Recruiting
Szpital Wojewódzki w Bielsku-Białej
Bielsko-Biala
Krzysztof Pietrzak, Dr, kpietrza@mp.pl
- Recruiting
Wojewódzki Szpital Specjalistyczny nr 4
Bytom
Janusz Kuśmierz, Dr, januszk5@op.pl
- Recruiting
Małopolska Cardiovascular Center, Polish-American Heart Clinic in Chrzanów
Chrzanów
Przemysław Nowakowski, MD, PhD, Prof, (+48) 32 758 69 01, nowakowski.mcsn@gmail.com
- Recruiting
118 Szpital Wojskowy z Przychodnią SPZOZ
Ełk
Robert Tworus, Dr, rtworus@gmail.com
- Recruiting
Szpital im. Św. Wincentego a Paulo
Gdynia
Ryszard Zając, Dr, chirurgia.naczyn@gmail.com
- Recruiting
Wojewódzki Szpital Zespolony
Kielce
Jarosław Miszczuk, Dr, chirurgia.naczyniowa@wszzkielce.pl
- Recruiting
Bonifraterskie Centrum Medyczne
Krakow
Maciej Chwała, Dr, mchwla@poczta.fm
- Recruiting
Krakowski Szpital Specjalistyczny im. JPII
Krakow
Mariusz Trystuła, Dr hab., mrt@onet.pl
- Recruiting
Uniwersytecki Szpital Kliniczny nr 1 im. Norberta Barlickiego
Lublin
Piotr Terlecki, Prof., piotrterlecki@interia.pl
- Recruiting
Uniwersytecki Szpital Kliniczny Nr 4
Lublin
Michał Sojka, Dr hab, michal.sojka@usk4.lublin.pl
- Recruiting
Wojewódzki Szpital Specjalistyczny w Lublinie
Lublin
Marek Chrapko, Dr, chrapmar@wp.pl
- Recruiting
Uniwersytecki Szpital Kliniczny w Opolu
Opole
Grzegorz Oszkinis, Prof, goszkinis@gmail.com
- Recruiting
Uniwersytecki Szpital Kliniczny w Poznaniu
Poznan
Jerzy Kulesza, Dr, jerzykulesza@pro.onet.pl
- Recruiting
Wojewódzki Szpital im. Św. Ojca Pio
Przemyśl
Magdalena Biss-Mierzwińska, Dr, abiska55@gmail.com
- Recruiting
Uniwersytecki Szpital Kliniczny Nr 2 PUM
Szczecin
Arkadiusz Kazimierczak, Prof., biker2000@wp.pl
- Recruiting
Mazowiecki Szpital Bródnowski
Warsaw
Piotr Myrcha, Prof., piotrmyr@poczta.fm
- Recruiting
Narodowy Instytut Kardiologii
Warsaw
Piotr Szopiński, Prof., petszop@wp.pl
- Recruiting
Uniwersyteckie Centrum Kliniczne WUM
Warsaw
Zbigniew Gałązka, Prof., zbigniew.galazka@wum.edu.pl
- Recruiting
Wodzisławskie Centrum Medyczne
Wodzisław Śląski
Marek Kazibudzki, Dr, marekkaz@poczta.fm
- Recruiting
Szpital Uniwersytecki im. Karola Marcinkowskiego
Zielona Góra
Łukasz Dzieciuchowicz, Prof., L.Dzieciuchowicz@inm.uz.zgora.pl
Italy5 sites, 5 recruiting
- Not yet recruiting
Clinica Pineta Grande
Castel Volturno
Rosario Mancusi, Dr, + 3397987208, rosario.mancusimd@gmail.com
- Not yet recruiting
Centro Cuore Morgagni
Catania
Vincenzo Monaca, Dr
Daniele Sangrigoli, Dr
- Not yet recruiting
IRCCS Neuromed - Istituto Neurologico Mediterraneo
Pozzilli
Enrico Cappello, Dr, + 3492358308, enrico.cappello@yahoo.it
- Not yet recruiting
Arcispedale Santa Maria Nuova
Reggio Emilia
Nicola Tusini, Dr, tusini.nicola@smn.re.it
- Not yet recruiting
Policlinico San Donato
San Donato Milanese
Giovanni Nano, Prof., + 39 3389754423, giovanni.nano@libero.it
About this study
Official title: A Pragmatic, Observational, Multicenter Registry on the Implantation of the Tri Modular PERCUTEK Tycheseal™ Endograft System for the Treatment of Abdominal Aortic Aneurysm (AAA)
Objective To pragmatically collect and analyze patient-level clinical, procedural, and outcome data from participating centers in Italy and Poland on the use of the PERCUTEK Tycheseal™ stent-graft system for the endovascular repair of abdominal aortic aneurysms. The study aims to generate high-quality, real-world evidence on the technical success, safety, and mid-term outcomes of the device.
Study Design This is a pragmatic, observational, multicenter physician-initiated registry that will collect patient-level data for all eligible patients undergoing PERCUTEK Tycheseal™ device implantation. Each site will enter data into a standardized paper case report form (CRF), including demographic, anatomical, procedural, and follow-up variables. Sites will be expected to comply with data entry timelines and quality control checks. The total projected enrollment is 120-200 patients across all sites over an expected 18 month inclusion period.
The target enrollment is 120-200 patients across all participating sites.
Read the detailed description
Background and Rationale
Abdominal Aortic Aneurysm (AAA): Clinical Burden and Unmet Needs Abdominal aortic aneurysm (AAA) is a progressive and potentially fatal vascular disease defined as a localized dilatation of the abdominal aorta exceeding 1.5 times its normal diameter, typically ≥3.0 cm. The pathophysiology of AAA involves complex interplay between genetic predisposition, chronic inflammation, extracellular matrix degradation, and biomechanical wall stress. Risk factors for AAA include advanced age, male sex, smoking, hypertension, dyslipidemia, and family history. Notably, population based screening studies have shown that up to 5-8% of men over the age of 65 harbor asymptomatic AAAs, many of which are at risk of expansion and eventual rupture if left untreated. The clinical importance of timely diagnosis and treatment of AAA lies in its natural history: once the aneurysm reaches a critical threshold-commonly 5.5 cm in diameter in men or 5.0 cm in women-the risk of rupture increases substantially. Aneurysm rupture is associated with extremely high mortality, with up to 90% of patients dying before reaching the hospital or during emergency intervention. Consequently, elective repair is indicated in appropriately selected patients based on aneurysm size, growth rate, symptomatology, and anatomical feasibility.
Advances and Challenges in Endovascular Aneurysm Repair (EVAR) Over the past two decades, endovascular aneurysm repair (EVAR) has largely supplanted open surgical repair (OSR) as the preferred modality for treating infrarenal AAA in anatomically suitable patients. EVAR offers several perioperative advantages, including reduced operative blood loss, shorter procedure times, lower 30-day mortality rates, and faster postoperative recovery. These benefits make EVAR especially attractive for elderly patients and those with significant comorbidities who may not tolerate open surgery.
Despite these advantages, EVAR is not without limitations. Long-term surveillance is required due to risks of late complications such as graft migration, endoleak formation (particularly types I and III), aneurysm sac expansion, and device thrombosis. These complications may necessitate secondary interventions and contribute to long-term morbidity. Additionally, anatomical constraints such as short or highly angulated necks, calcification, thrombus burden, and tortuous iliac arteries may preclude the safeuse of some endograft systems. As a result, device selection plays a crucial role in procedural success and long-term outcomes.
The Poland-Italy Aortic Research Bridge Real World Registry (POWER) is a pragmatic, observational, multicenter registry designed to systematically collect real-world data on the use of the PERCUTEK Tycheseal™Tri-Modular Endograft System in patients undergoing endovascular repair of abdominal aortic aneurysms (AAA).
Study Type This is a non-randomized, open-label, post-market physician-initiated clinical investigation. It does not involve experimental treatments or random allocation of interventions, and no comparator arm is included.
Objectives
- To assess technical success and safety outcomes associated with the use of the PERCUTEK Tycheseal™system.
- To evaluate mid-term clinical outcomes, including aneurysm sac behavior, endoleak rates, and device-related complications over a follow-up period of up to 24 months.
Participating Countries and Sites
- Multicenter registry with sites in Poland and Italy.
- Sites must demonstrate documented experience in aortic endovascular repair.
- Each participating center must have local ethics approval and assign a trained data manager and a site principal investigator, unless a general (e.g. national or regional) ethics committee approval is applicable.
Estimated Enrollment
- A total of 120-200 patients will be enrolled consecutively over approximately 18 months.
Each subject will be followed for up to 24 months post-implantation, with assessments at baseline, discharge, 1 month, 12 months and 24 months.
The PERCUTEK Tycheseal™Endograft System: Design Rationale The PERCUTEK Tycheseal™ system is a tri-modular stent graft platform designed for the treatment of infrarenal AAA. It consists of a main body and two iliac limb components, each optimized for precision deployment, modular adaptability, and enhanced seal zone conformity. The device is intended to address common anatomical challenges by accommodating a wide range of aortic neck diameters (main body proximal graft diameters: 20-36 mm, with 10-20% of oversizing), tolerating moderate angulation (up to 75°), and facilitating reliable fixation and sealing even in anatomically complex patients.
The PERCUTEK Tycheseal™ system features a low-profile delivery system, radiopaque markers for fluoroscopic visibility, and graft materials engineered for biocompatibility and durability. Early use in single-center case series and preliminary feasibility studies suggests that the device offers favorable deliverability, short procedure duration, and high technical success. However, robust, pragmatic, multicenter data in real-world settings are still lacking, which limits broader confidence in its long-term safety and performance.
Rationale for the POWER Registry The Poland-Italy Aortic Research Bridge Real World Registry (POWER) has been established to pragmatically evaluate the use of the PERCUTEK Tycheseal™ stent graft system in a real-world clinical environment across multiple high-volume European centers. This physician-initiated registry aims to fill a critical evidence gap by generating longitudinal, patient-level data on technical feasibility, clinical outcomes, and device-related complications over a 12-24- month period.
Several compelling factors justify the need for this registry:
- Real-World Generalizability: Unlike tightly controlled randomized trials, the POWER Registry reflects actual clinical practice, encompassing diverse operator experience levels, institutional protocols, and patient anatomies.
- Post-Market Surveillance: As the PERCUTEK Tycheseal™ system expands into routine use, structured post-market follow-up becomes essential to detect rare adverse events and performance trends.
- Multinational Collaboration: By including centers from both Poland and Italy, the registry promotes transnational harmonization of endovascular standards and facilitates benchmarking of regional clinical outcomes.
- Clinical Decision Support: The findings from this registry will provide procedural insights and safety benchmarks that can inform clinical decision-making, guideline development, and payer evaluations.
Through detailed documentation of implantation success, early and mid-term complications, and follow-up imaging, the POWER Registry will support an evidencebased understanding of the PERCUTEK Tycheseal™system's performance. The use of standardized paper CRFs, centralized data coordination, and optional site-level aggregate submissions ensures a flexible yet rigorous data capture approach. Ultimately, the POWER Registry aligns with contemporary regulatory and clinical imperatives for post-market device surveillance, and its findings are expected to directly contribute to the refinement of EVAR indications, device iteration, and patient centered care in AAA management.
- Conditions
- Abdominal Aortic Aneurysm
- Keywords
- Abdominal aortic aneurysm, Endovascular Aneurysm Repair, PERCUTEK Tycheseal™, vascular disease, stent graft
- Medical subject headings
- Aortic Aneurysm, Abdominal, Vascular Diseases
What is being measured
The primary outcome is the main question the study is designed to answer.
Technical success of the PERCUTEK Tycheseal™ stent-graft implantation, defined as successful deployment at the intended site with the absence of immediate type I or III endoleaks and no requirement for unplanned conversion to open repair.
Measured: 12 months
Freedom from aneurysm sac enlargement, defined as no increase ≥5 mm in the maximum transverse aortic aneurysm diameter at 12 months compared to baseline imaging.
Measured: 12 month
Freedom from type I or III endoleaks, confirmed by Doppler ultrasound or angio CT at the 6- and 12-month follow-ups.
Measured: 6 and 12 months
Freedom from aneurysm rupture during the 12-month follow-up period.
Measured: 12 months
Freedom from stent-graft migration resulting in a serious adverse event or requiring secondary intervention.
Measured: 12 months
Freedom from any stent-graft occlusion at 12 months.
Measured: 12 months
Secondary outcomes (7)
Aneurysm-related mortality at 12 months
Measured: 12 months
All-cause mortality
Measured: 30 days; 12 months
Aneurysm sac regression >5 mm at 12 months compared to baseline.
Measured: 12 months
Major adverse events (MAEs) at 30 days, 12 months, and 24 months, including: Myocardial infarction, Stroke or transient ischemic attack, New-onset renal failure or dialysis requirement.
Measured: 30 days; 12 months; 24 months
All endoleaks (types I, II, III, or undefined origin) detected at 30 days, 12 months, and 24 months.
Measured: 30 days; 12 month; 24 months
Reinterventions, categorized as: For treatment of endoleaks, For stent-graft thrombosis or occlusion.
Measured: 24 months
Serious adverse device effects (SADEs) throughout the study period.
Measured: 24 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted17 Mar 2026
- Study start1 Mar 2026
- Primary completion31 Mar 2027 (estimated)
- Study completion31 Mar 2030 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (20)Papers the sponsor has linked to this study.
- Other trials for Abdominal Aortic AneurysmStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 200 participants (estimated)
- Target duration
- 24 Months
Sponsor and investigators
- Lead sponsor
- American Heart of Poland
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Przemysław Nowakowski, American Heart of Poland
- Investigators
- Przemysław Nowakowski, MD,PhD, Prof, Principal investigator, American Heart of Poland
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07476196
- Sponsor's protocol ID
- POWER-AAA-2025
- Acronym
- POWER
- Status last verified
- Mar 2026
- First submitted
- 12 Mar 2026
- Last updated
- 20 Mar 2026
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
Publications
Zong NC, Huang K, Yang X, Cai H. Expand the success of screening to reduce aortic aneurysm mortality: progress interpretation and new fronts. Trends Cardiovasc Med. 2025 May;35(4):221-229. doi: 10.1016/j.tcm.2024.12.004. Epub 2024 Dec 13.
PubMed 39675687Ziaja K, Nowakowski P, Simka M. [Repeated excision of abdominal aortic aneurysm--case report]. Wiad Lek. 2000;53(11-12):701-5. Polish.
PubMed 11247416Wierzejski W, Nowakowski P, Drobinski D. Ascending aortic dissection diagnosed with the use of point-of-care sonography. Case report. J Ultrason. 2014 Dec;14(59):428-34. doi: 10.15557/JoU.2014.0045. Epub 2014 Dec 30.
PubMed 26673414Wang S, Fu W, Wang L. First in man: PERCUTEK Tianyi(R) stent-graft greatly facilitated in situ fenestration during thoracic aortic aneurysm endovascular repair. Eur Heart J Case Rep. 2024 Dec 9;9(1):ytae638. doi: 10.1093/ehjcr/ytae638. eCollection 2025 Jan. No abstract available.
PubMed 39802051Troisi N, Pulli R, Donato G, Adami D, Bertagna G, Michelagnoli S, Berchiolli R; ALPHA Abdominal registry Collaborative Group *. Early and Midterm Outcomes of Endovascular Aneurysm Repair With Zenith Alpha Abdominal Stent-Graft: Results From a Multicenter Retrospective Tuscany Registry. J Endovasc Ther. 2025 Jun;32(3):794-801. doi: 10.1177/15266028231197151. Epub 2023 Aug 30.
PubMed 37646124Stokmans RA, Teijink JA, Forbes TL, Bockler D, Peeters PJ, Riambau V, Hayes PD, van Sambeek MR. Early results from the ENGAGE registry: real-world performance of the Endurant Stent Graft for endovascular AAA repair in 1262 patients. Eur J Vasc Endovasc Surg. 2012 Oct;44(4):369-75. doi: 10.1016/j.ejvs.2012.07.005. Epub 2012 Jul 24.
PubMed 22835762Sirignano P, Andreoli F, Gaggiano A, Accarino G, Tusini N, Benedetto F, Veroux P, Silingardi R, Taurino M, Speziale F; AFX2-LIVE Collaborative Study Group. Infrarenal Aortic Treatment With AFX2 Endograft: Results From a Multicentric, International, Non-Randomized, Prospective Registry-the AFX2-LIVE Study. J Endovasc Ther. 2026 Apr;33(2):940-950. doi: 10.1177/15266028241284364. Epub 2024 Oct 6.
PubMed 39369322Reyes Valdivia A, Pitoulias G, Criado FJ, Torsello G, Gandarias C, Austermann M, Pitoulias AG, Donas K. Multicenter European Registry for Patients with AAA Undergoing EVAR Evaluating the Performance of the 36-mm-Diameter Endurant Stent-Graft. Cardiovasc Intervent Radiol. 2017 Oct;40(10):1514-1521. doi: 10.1007/s00270-017-1665-6. Epub 2017 May 1.
PubMed 28462441Rastogi V, Summers SP, Yadavalli SD, Perrier J, Allievi S, Jabbour G, Stangenberg L, de Bruin JL, Jones D, Ferran CJ, Verhagen HJM, Schermerhorn ML. Association between diabetes status and long-term outcomes following open and endovascular repair of infrarenal abdominal aortic aneurysms. J Vasc Surg. 2024 Dec;80(6):1685-1696.e1. doi: 10.1016/j.jvs.2024.08.030. Epub 2024 Aug 23.
PubMed 39181338Nowakowski P, Uchto W, Stolinski J, Gubala M, Legut M. Endovascular treatment of infrarenal aortic aneurysm using the ANKURA stent graft - one-center case series. Postepy Kardiol Interwencyjnej. 2023 Mar;19(1):67-69. doi: 10.5114/aic.2023.124041. Epub 2023 Jan 11. No abstract available.
PubMed 37090207Meuli L, Zimmermann A, Petersen JK, Fosbol EL, Dabravolskaite V, Makaloski V, Eiberg JP, Kober LV, Resch TA. Risk Stratification and Treatment Selection in Patients With Asymptomatic Abdominal Aortic Aneurysms. JAMA Netw Open. 2025 Apr 1;8(4):e253559. doi: 10.1001/jamanetworkopen.2025.3559.
PubMed 40193076Marone EM, Rinaldi LF, Brioschi C, Bracale UM, Modugno P, Maione M, Curci R, Filippi F, Piffaretti G, Gaggiano A, Palasciano G, Angiletta D, Michelagnoli S, Forliti E, Ercolini L, Pulli R; TIGRE REGISTRY GROUP. Endovascular Aortic Repair With the E-Tegra Device: Preliminary Outcomes From a Multicenter National Registry. J Endovasc Ther. 2026 Apr;33(2):710-720. doi: 10.1177/15266028241270861. Epub 2024 Aug 27.
PubMed 39188184Kontopodis N, Gavalaki A, Galanakis N, Kantzas M, Ioannou C, Geroulakos G, Kakisis J, Antoniou GA. Systematic Review With Meta-Analysis of Endovascular Versus Open Repair of Abdominal Aortic Aneurysm Repair in the Young. J Endovasc Ther. 2025 Apr;32(2):276-289. doi: 10.1177/15266028231179419. Epub 2023 Jun 22.
PubMed 37350089Hoshina K. A Multifaceted Approach to Abdominal Aortic Aneurysm. Ann Vasc Dis. 2025;18(1):24-00137. doi: 10.3400/avd.ra.24-00137. Epub 2025 Jan 21.
PubMed 39877329Francisco-Azevedo J, Romana-Dias L, Ribeiro H, Dias-Neto M, Rocha-Neves J. Incidence of Myocardial Injury in Patients Submitted to Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis. Ann Vasc Surg. 2025 Nov;120:57-76. doi: 10.1016/j.avsg.2025.05.006. Epub 2025 May 10.
PubMed 40349833
Study at a glance
From the registry record, last updated by the sponsor on 20 Mar 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Pragmatic, Observational, Multicenter Registry on the Implantation of the Tri Modular PERCUTEK Tycheseal™ Endograft System for the Treatment of Abdominal Aortic Aneurysm (AAA)
- ClinicalTrials.gov ID
- NCT07476196
- Acronym / sponsor ID
- POWER / POWER-AAA-2025
- Conditions
- Abdominal Aortic Aneurysm
- Keywords
- Abdominal aortic aneurysm, Endovascular Aneurysm Repair, PERCUTEK Tycheseal™, vascular disease, stent graft
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 200 participants (estimated)
- Lead sponsor
- American Heart of PolandUniversity, hospital or other
- Study start
- 1 Mar 2026 (actual)
- Primary completion
- 31 Mar 2027 (estimated)
- Study completion
- 31 Mar 2030 (estimated)
- First posted
- 17 Mar 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Objective To pragmatically collect and analyze patient-level clinical, procedural, and outcome data from participating centers in Italy and Poland on the use of the PERCUTEK Tycheseal™ stent-graft system for the endovascular repair of abdominal aortic aneurysms. The study aims to generate high-quality, real-world evidence on the technical success, safety, and mid-term outcomes of the device.
Study Design This is a pragmatic, observational, multicenter physician-initiated registry that will collect patient-level data for all eligible patients undergoing PERCUTEK Tycheseal™ device implantation. Each site will enter data into a standardized paper case report form (CRF), including demographic, anatomical, procedural, and follow-up variables. Sites will be expected to comply with data entry timelines and quality control checks. The total projected enrollment is 120-200 patients across all sites over an expected 18 month inclusion period.
The target enrollment is 120-200 patients across all participating sites.
Detailed description
Background and Rationale
Abdominal Aortic Aneurysm (AAA): Clinical Burden and Unmet Needs Abdominal aortic aneurysm (AAA) is a progressive and potentially fatal vascular disease defined as a localized dilatation of the abdominal aorta exceeding 1.5 times its normal diameter, typically ≥3.0 cm. The pathophysiology of AAA involves complex interplay between genetic predisposition, chronic inflammation, extracellular matrix degradation, and biomechanical wall stress. Risk factors for AAA include advanced age, male sex, smoking, hypertension, dyslipidemia, and family history. Notably, population based screening studies have shown that up to 5-8% of men over the age of 65 harbor asymptomatic AAAs, many of which are at risk of expansion and eventual rupture if left untreated. The clinical importance of timely diagnosis and treatment of AAA lies in its natural history: once the aneurysm reaches a critical threshold-commonly 5.5 cm in diameter in men or 5.0 cm in women-the risk of rupture increases substantially. Aneurysm rupture is associated with extremely high mortality, with up to 90% of patients dying before reaching the hospital or during emergency intervention. Consequently, elective repair is indicated in appropriately selected patients based on aneurysm size, growth rate, symptomatology, and anatomical feasibility.
Advances and Challenges in Endovascular Aneurysm Repair (EVAR) Over the past two decades, endovascular aneurysm repair (EVAR) has largely supplanted open surgical repair (OSR) as the preferred modality for treating infrarenal AAA in anatomically suitable patients. EVAR offers several perioperative advantages, including reduced operative blood loss, shorter procedure times, lower 30-day mortality rates, and faster postoperative recovery. These benefits make EVAR especially attractive for elderly patients and those with significant comorbidities who may not tolerate open surgery.
Despite these advantages, EVAR is not without limitations. Long-term surveillance is required due to risks of late complications such as graft migration, endoleak formation (particularly types I and III), aneurysm sac expansion, and device thrombosis. These complications may necessitate secondary interventions and contribute to long-term morbidity. Additionally, anatomical constraints such as short or highly angulated necks, calcification, thrombus burden, and tortuous iliac arteries may preclude the safeuse of some endograft systems. As a result, device selection plays a crucial role in procedural success and long-term outcomes.
The Poland-Italy Aortic Research Bridge Real World Registry (POWER) is a pragmatic, observational, multicenter registry designed to systematically collect real-world data on the use of the PERCUTEK Tycheseal™Tri-Modular Endograft System in patients undergoing endovascular repair of abdominal aortic aneurysms (AAA).
Study Type This is a non-randomized, open-label, post-market physician-initiated clinical investigation. It does not involve experimental treatments or random allocation of interventions, and no comparator arm is included.
Objectives
- To assess technical success and safety outcomes associated with the use of the PERCUTEK Tycheseal™system.
- To evaluate mid-term clinical outcomes, including aneurysm sac behavior, endoleak rates, and device-related complications over a follow-up period of up to 24 months.
Participating Countries and Sites
- Multicenter registry with sites in Poland and Italy.
- Sites must demonstrate documented experience in aortic endovascular repair.
- Each participating center must have local ethics approval and assign a trained data manager and a site principal investigator, unless a general (e.g. national or regional) ethics committee approval is applicable.
Estimated Enrollment
- A total of 120-200 patients will be enrolled consecutively over approximately 18 months.
Each subject will be followed for up to 24 months post-implantation, with assessments at baseline, discharge, 1 month, 12 months and 24 months.
The PERCUTEK Tycheseal™Endograft System: Design Rationale The PERCUTEK Tycheseal™ system is a tri-modular stent graft platform designed for the treatment of infrarenal AAA. It consists of a main body and two iliac limb components, each optimized for precision deployment, modular adaptability, and enhanced seal zone conformity. The device is intended to address common anatomical challenges by accommodating a wide range of aortic neck diameters (main body proximal graft diameters: 20-36 mm, with 10-20% of oversizing), tolerating moderate angulation (up to 75°), and facilitating reliable fixation and sealing even in anatomically complex patients.
The PERCUTEK Tycheseal™ system features a low-profile delivery system, radiopaque markers for fluoroscopic visibility, and graft materials engineered for biocompatibility and durability. Early use in single-center case series and preliminary feasibility studies suggests that the device offers favorable deliverability, short procedure duration, and high technical success. However, robust, pragmatic, multicenter data in real-world settings are still lacking, which limits broader confidence in its long-term safety and performance.
Rationale for the POWER Registry The Poland-Italy Aortic Research Bridge Real World Registry (POWER) has been established to pragmatically evaluate the use of the PERCUTEK Tycheseal™ stent graft system in a real-world clinical environment across multiple high-volume European centers. This physician-initiated registry aims to fill a critical evidence gap by generating longitudinal, patient-level data on technical feasibility, clinical outcomes, and device-related complications over a 12-24- month period.
Several compelling factors justify the need for this registry:
- Real-World Generalizability: Unlike tightly controlled randomized trials, the POWER Registry reflects actual clinical practice, encompassing diverse operator experience levels, institutional protocols, and patient anatomies.
- Post-Market Surveillance: As the PERCUTEK Tycheseal™ system expands into routine use, structured post-market follow-up becomes essential to detect rare adverse events and performance trends.
- Multinational Collaboration: By including centers from both Poland and Italy, the registry promotes transnational harmonization of endovascular standards and facilitates benchmarking of regional clinical outcomes.
- Clinical Decision Support: The findings from this registry will provide procedural insights and safety benchmarks that can inform clinical decision-making, guideline development, and payer evaluations.
Through detailed documentation of implantation success, early and mid-term complications, and follow-up imaging, the POWER Registry will support an evidencebased understanding of the PERCUTEK Tycheseal™system's performance. The use of standardized paper CRFs, centralized data coordination, and optional site-level aggregate submissions ensures a flexible yet rigorous data capture approach. Ultimately, the POWER Registry aligns with contemporary regulatory and clinical imperatives for post-market device surveillance, and its findings are expected to directly contribute to the refinement of EVAR indications, device iteration, and patient centered care in AAA management.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Target follow-up
- 24 Months
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients with abdominal aortic aneurysm
Key inclusion criteria (0 listed)
Key exclusion criteria (12 listed)
- Anatomical unsuitability
- Subject has a life expectancy < 1 year
- Circumferential thrombus in neck
- Ruptured aneurysm
- Renal arteries from aneurysm sac
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Technical success of the PERCUTEK Tycheseal™ stent-graft implantation, defined as successful deployment at the intended site with the absence of immediate type I or III endoleaks and no requirement for unplanned conversion to open repair.
Time frame: 12 months
Freedom from aneurysm sac enlargement, defined as no increase ≥5 mm in the maximum transverse aortic aneurysm diameter at 12 months compared to baseline imaging.
Time frame: 12 month
Freedom from type I or III endoleaks, confirmed by Doppler ultrasound or angio CT at the 6- and 12-month follow-ups.
Time frame: 6 and 12 months
Freedom from aneurysm rupture during the 12-month follow-up period.
Time frame: 12 months
Freedom from stent-graft migration resulting in a serious adverse event or requiring secondary intervention.
Time frame: 12 months
Freedom from any stent-graft occlusion at 12 months.
Time frame: 12 months
7 secondary outcomes
Aneurysm-related mortality at 12 months
Time frame: 12 months
All-cause mortality
Time frame: 30 days; 12 months
Aneurysm sac regression >5 mm at 12 months compared to baseline.
Time frame: 12 months
Major adverse events (MAEs) at 30 days, 12 months, and 24 months, including: Myocardial infarction, Stroke or transient ischemic attack, New-onset renal failure or dialysis requirement.
Time frame: 30 days; 12 months; 24 months
All endoleaks (types I, II, III, or undefined origin) detected at 30 days, 12 months, and 24 months.
Time frame: 30 days; 12 month; 24 months
Reinterventions, categorized as: For treatment of endoleaks, For stent-graft thrombosis or occlusion.
Time frame: 24 months
Serious adverse device effects (SADEs) throughout the study period.
Time frame: 24 months
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Mar 2026.
- Background: PubMed 39675687Zong NC, Huang K, Yang X, Cai H. Expand the success of screening to reduce aortic aneurysm mortality: progress interpretation and new fronts. Trends Cardiovasc Med. 2025 May;35(4):221-229. doi: 10.1016/j.tcm.2024.12.004. Epub 2024 Dec 13.
- Background: PubMed 11247416Ziaja K, Nowakowski P, Simka M. [Repeated excision of abdominal aortic aneurysm--case report]. Wiad Lek. 2000;53(11-12):701-5. Polish.
- Background: PubMed 26673414Wierzejski W, Nowakowski P, Drobinski D. Ascending aortic dissection diagnosed with the use of point-of-care sonography. Case report. J Ultrason. 2014 Dec;14(59):428-34. doi: 10.15557/JoU.2014.0045. Epub 2014 Dec 30.
- Background: PubMed 39802051Wang S, Fu W, Wang L. First in man: PERCUTEK Tianyi(R) stent-graft greatly facilitated in situ fenestration during thoracic aortic aneurysm endovascular repair. Eur Heart J Case Rep. 2024 Dec 9;9(1):ytae638. doi: 10.1093/ehjcr/ytae638. eCollection 2025 Jan. No abstract available.
- Background: PubMed 37646124Troisi N, Pulli R, Donato G, Adami D, Bertagna G, Michelagnoli S, Berchiolli R; ALPHA Abdominal registry Collaborative Group *. Early and Midterm Outcomes of Endovascular Aneurysm Repair With Zenith Alpha Abdominal Stent-Graft: Results From a Multicenter Retrospective Tuscany Registry. J Endovasc Ther. 2025 Jun;32(3):794-801. doi: 10.1177/15266028231197151. Epub 2023 Aug 30.
- Background: PubMed 22835762Stokmans RA, Teijink JA, Forbes TL, Bockler D, Peeters PJ, Riambau V, Hayes PD, van Sambeek MR. Early results from the ENGAGE registry: real-world performance of the Endurant Stent Graft for endovascular AAA repair in 1262 patients. Eur J Vasc Endovasc Surg. 2012 Oct;44(4):369-75. doi: 10.1016/j.ejvs.2012.07.005. Epub 2012 Jul 24.
- Background: PubMed 39369322Sirignano P, Andreoli F, Gaggiano A, Accarino G, Tusini N, Benedetto F, Veroux P, Silingardi R, Taurino M, Speziale F; AFX2-LIVE Collaborative Study Group. Infrarenal Aortic Treatment With AFX2 Endograft: Results From a Multicentric, International, Non-Randomized, Prospective Registry-the AFX2-LIVE Study. J Endovasc Ther. 2026 Apr;33(2):940-950. doi: 10.1177/15266028241284364. Epub 2024 Oct 6.
- Background: PubMed 28462441Reyes Valdivia A, Pitoulias G, Criado FJ, Torsello G, Gandarias C, Austermann M, Pitoulias AG, Donas K. Multicenter European Registry for Patients with AAA Undergoing EVAR Evaluating the Performance of the 36-mm-Diameter Endurant Stent-Graft. Cardiovasc Intervent Radiol. 2017 Oct;40(10):1514-1521. doi: 10.1007/s00270-017-1665-6. Epub 2017 May 1.
- Background: PubMed 39181338Rastogi V, Summers SP, Yadavalli SD, Perrier J, Allievi S, Jabbour G, Stangenberg L, de Bruin JL, Jones D, Ferran CJ, Verhagen HJM, Schermerhorn ML. Association between diabetes status and long-term outcomes following open and endovascular repair of infrarenal abdominal aortic aneurysms. J Vasc Surg. 2024 Dec;80(6):1685-1696.e1. doi: 10.1016/j.jvs.2024.08.030. Epub 2024 Aug 23.
- Background: PubMed 37090207Nowakowski P, Uchto W, Stolinski J, Gubala M, Legut M. Endovascular treatment of infrarenal aortic aneurysm using the ANKURA stent graft - one-center case series. Postepy Kardiol Interwencyjnej. 2023 Mar;19(1):67-69. doi: 10.5114/aic.2023.124041. Epub 2023 Jan 11. No abstract available.
- Background: PubMed 40193076Meuli L, Zimmermann A, Petersen JK, Fosbol EL, Dabravolskaite V, Makaloski V, Eiberg JP, Kober LV, Resch TA. Risk Stratification and Treatment Selection in Patients With Asymptomatic Abdominal Aortic Aneurysms. JAMA Netw Open. 2025 Apr 1;8(4):e253559. doi: 10.1001/jamanetworkopen.2025.3559.
- Background: PubMed 39188184Marone EM, Rinaldi LF, Brioschi C, Bracale UM, Modugno P, Maione M, Curci R, Filippi F, Piffaretti G, Gaggiano A, Palasciano G, Angiletta D, Michelagnoli S, Forliti E, Ercolini L, Pulli R; TIGRE REGISTRY GROUP. Endovascular Aortic Repair With the E-Tegra Device: Preliminary Outcomes From a Multicenter National Registry. J Endovasc Ther. 2026 Apr;33(2):710-720. doi: 10.1177/15266028241270861. Epub 2024 Aug 27.
Related trials for Abdominal Aortic Aneurysm
Not yet recruitingObservational study
Pilot Study on the Effectiveness and Safety of OPTILENE® SILVER MESH ELASTIC in Prevention of Surgical Site Infection (SSI) and Incisional Hernia (IH)
Abdominal Aortic Aneurysm, Morbid Obesity
RecruitingPhase 4
Effect of Remimazolam Versus Propofol Total Intravenous Anesthesia on Intraoperative Hemodynamic Stability in Patients Undergoing Thoracic or Abdominal Endovascular Aortic Repair
Aortic Aneurysm, Thoracoabdominal, Aortic Aneurysm, Abdominal
Not yet recruitingObservational study
Aortic Size and Height Indices in Abdominal Aortic Aneurysms
Abdominal Aortic Aneurysm, Abdominal Aortic Aneurysm, Ruptured
Not yet recruitingObservational study
Real-World Data Collection of GORE Devices Used In the Endovascular Treatment of Aortic Aneurysms Which Incorporate Visceral Arteries.
Complex Aortic Aneurysms, Thoracoabdominal Aneurysm
Enrolling by invitation
Endovascular Treatment of Thoracic Aortic Disease
Thoracic Aortic Aneurysms, Dissecting, Aneurysm
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Przemysław Nowakowski, MD,PhD, Prof principal investigator
American Heart of Poland
26 sites in 2 countries: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Abdominal Aortic Aneurysm, run by American Heart of Poland at 26 sites in 2 countries.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 0 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 20 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 26 sites in Poland, Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Przemysław Nowakowski, MD, PhD, Prof ((+48) 32 758 69 01, nowakowski.mcsn@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Technical success of the PERCUTEK Tycheseal™ stent-graft implantation, defined as successful deployment at the intended site with the absence of immediate type I or III endoleaks and no requirement for unplanned conversion to open repair. (time frame: 12 months). The study lists 6 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07476196, which also lists 20 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Mar 2026.