Amyotrophic Lateral SclerosisNCT07502677
Diagnostic Accuracy of SleepImage Technology for Detecting Respiratory Failure in Patients With Amyotrophic Lateral Sclerosis
An observational study of Amyotrophic Lateral Sclerosis, run by Royal Brompton & Harefield NHS Foundation Trust at 1 site in United Kingdom.
Trial summary
The specific aim of this study is to try to discover the diagnostic accuracy of SleepImage technology for detecting respiratory failure in patients with MND. Importantly, this research project is not about NIV, it is about what method can most efficiently decide when to start NIV. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Amyotrophic Lateral Sclerosis
- What is being tested?
- SleepImage
- Type of treatment
- Medical device
- How many people
- 15 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- 24 Mar 2026to 24 Mar 2027
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Amyotrophic Lateral Sclerosis
Who may be able to join
- Patients aged 18 and over with a Neurologist confirmed diagnosis of ALS
Who cannot join
- Patients with known respiratory disease
- Unstable cardiac disease, stable hypertension or ischaemic heart disease
- Current NIV use
- Inability to give consent (expected ~15% due to frontotemporal dementia)
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Lucy Redmond contact
United Kingdom1 site, 1 recruiting
- Recruiting
Royal Brompton Hospital
London, sw3 6np
Lucy Redmond, Physiotherapy, 07752472282, lucy.redmond4@nhs.net
About this study
The specific aim of this study is to try to discover the diagnostic accuracy of SleepImage technology for detecting respiratory failure in patients with MND. Importantly, this research project is not about NIV, it is about what method can most efficiently decide when to start NIV.
To do this we'd like to collect data about you and your breathing from the SleepImage device when you come in for your routine overnight sleep study. We will compare this against the data that we would collect anyway.
Read the detailed description
In general, where lung mechanics are normal, oxygen (O2) levels are the reciprocal of carbon dioxide (CO2) levels. However, due to the sigmoid shape of the oxygen dissociation curve peripheral capillary measurement of O2 (SpO2) via pulse oximeter does not provide adequate warning of respiratory failure in ALS. Advancements in sleep diagnostic equipment has allowed for the SleepImage System in addition to measuring SpO2, to also use tonometry to assesses autonomic output during sleep. SleepImage is US Food and Drug Administration, FDA-cleared and European Union Medical Device Regulatory EU-MDR compliant (CE-marked medical device). Specifically, SleepImage determines sleep architecture based on the strength of synchronisation between signals from the cardiovascular system (pulse rate variability) and respiratory system (tidal volume variability), based on cardiopulmonary coupling (CPC) analysis. Three distinct patterns of CPC are detected; (1) stable sleep (high-frequency coupling, HFC;0.1-0.4Hz) including all electroencephalogram estimated NREM-3 and part of NREM-2 sleep, associated with periods of stable breathing, non-cyclic alternating pattern (CAP) on the EEG, increased delta power and blood pressure dipping, (2) unstable sleep (low-frequency coupling, LFC;0.01-0.1Hz) including all NREM-1 and portion of NREM-2 associated with sleep instability, characterized by variability in tidal volumes, blood pressure non-dipping and CAP on EEG, (3) Wake and rapid eye movement (REM) sleep (very low-frequency coupling characteristics, vLFC;0-0.01Hz). The device can identify potential sleep pathologies evidenced by activity in a subset of unstable sleep where two discernible bands emerge; (1) a broad-spectral-band e-LFC (eLFCBB), linked to sleep fragmentation and obstructive sleep apnoea and (2) a narrow-spectral-band e-LCC (eLFCNB) in the frequency range 0.0006 to 0.1Hz, indicative of putative central sleep apnoea, periodic breathing or complex sleep apnoea. These metrics are expressed as a percentage of analysis windows related to the total sleep period. Other SleepImage diagnostic parameters include the Sleep Quality Index (SQI) which is biomarker and objective score of overall sleep quality. SQI integrates sleep stability, fragmentation, sleep duration and sleep pathologies derived from CPC and is presented on a scale of 0-100, apnoea hypopnea index , hypoxic burden , sleep onset, sleep offset, sleep duration, total sleep time , wake after sleep onset and sleep efficiency. At a practical level, the SleepImage device is a single patient, multiple use device which can be posted to the patient's home. It thus permits a sleep study assessment on as frequent as a basis as the physician and patient wish within the home setting.
The aim of this feasibility study is to review the efficacy of the SleepImage diagnostic equipment as a predictor of ventilatory impairment. This will be determined by a sleep quality index SQI of <55 and Periodicity (eLFCNB) >2 showing an association with ventilatory failure.
The use of the SleepImage technology would not be to replace current diagnostic tests such as SNIP, VC, TcCO2 and blood gases, but instead used as an early screen tool. If a positive association can be made between SQI, Periodicity and ventilatory failure, then SleepImage technology could be used as a tool to expedite the process of hospital diagnostic tests to assess for ventilatory impairment. Furthermore, the SleepImage technology could be used once patients are established onto ventilation as a way of monitoring their ventilatory control on therapy.
- Conditions
- Amyotrophic Lateral Sclerosis
- Being tested
- SleepImage
- Medical subject headings
- Amyotrophic Lateral Sclerosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
SleepImageDevice
SleepImage Device
| Study group | Role | What they receive |
|---|---|---|
| Diagnosis of ALS without NIV | Not described Receives: Device: SleepImage |
What is being measured
The primary outcome is the main question the study is designed to answer.
SQI & e-LFCNB>2
We hypothesise that a SQI <55 and Periodicity e-LFCNB>2 has a positive association with an accepted indication for NIV initiation in ALS defined as:
- Daytime Carbon Dioxide >6.0kPa and a rise of >1kPa from baseline in a time course consistent with REM sleep
- Bicarbonate levels >32mmol/L
- SNIP <40cmH20 in patients with non-bulbar disease
- Supine fall in VC of 20% from erect in patient able to undertake the manoeuvre
Measured: 12 hours
Secondary outcomes (1)
Hypoxic burden, T90, Pulse rate variability
The secondary endpoints of the study are to evaluate additional outputs generated by the SleepImage device and determine their association with the same established clinical criteria for NIV initiation in ALS. Specifically, the secondary analyses will focus on:
- Hypoxic burden
- SpO₂ time below 90% (T90).
- Pulse rate variability
Measured: 12 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted31 Mar 2026
- Study start24 Mar 2026
- Primary completion1 Sep 2026 (estimated)
- Study completion24 Mar 2027 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Amyotrophic Lateral SclerosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 15 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Royal Brompton & Harefield NHS Foundation Trust
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07502677
- Sponsor's protocol ID
- SleepImage in ALS IRAS 365043
- Status last verified
- Feb 2026
- First submitted
- 24 Mar 2026
- Last updated
- 31 Mar 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 31 Mar 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Diagnostic Accuracy of SleepImage Technology for Detecting Respiratory Failure in Patients With Amyotrophic Lateral Sclerosis
- ClinicalTrials.gov ID
- NCT07502677
- Acronym / sponsor ID
- SleepImage in ALS IRAS 365043
- Conditions
- Amyotrophic Lateral Sclerosis
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 15 participants (estimated)
- Lead sponsor
- Royal Brompton & Harefield NHS Foundation TrustUniversity, hospital or other
- Study start
- 24 Mar 2026 (actual)
- Primary completion
- 1 Sep 2026 (estimated)
- Study completion
- 24 Mar 2027 (estimated)
- First posted
- 31 Mar 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The specific aim of this study is to try to discover the diagnostic accuracy of SleepImage technology for detecting respiratory failure in patients with MND. Importantly, this research project is not about NIV, it is about what method can most efficiently decide when to start NIV.
To do this we'd like to collect data about you and your breathing from the SleepImage device when you come in for your routine overnight sleep study. We will compare this against the data that we would collect anyway.
Detailed description
In general, where lung mechanics are normal, oxygen (O2) levels are the reciprocal of carbon dioxide (CO2) levels. However, due to the sigmoid shape of the oxygen dissociation curve peripheral capillary measurement of O2 (SpO2) via pulse oximeter does not provide adequate warning of respiratory failure in ALS. Advancements in sleep diagnostic equipment has allowed for the SleepImage System in addition to measuring SpO2, to also use tonometry to assesses autonomic output during sleep. SleepImage is US Food and Drug Administration, FDA-cleared and European Union Medical Device Regulatory EU-MDR compliant (CE-marked medical device). Specifically, SleepImage determines sleep architecture based on the strength of synchronisation between signals from the cardiovascular system (pulse rate variability) and respiratory system (tidal volume variability), based on cardiopulmonary coupling (CPC) analysis. Three distinct patterns of CPC are detected; (1) stable sleep (high-frequency coupling, HFC;0.1-0.4Hz) including all electroencephalogram estimated NREM-3 and part of NREM-2 sleep, associated with periods of stable breathing, non-cyclic alternating pattern (CAP) on the EEG, increased delta power and blood pressure dipping, (2) unstable sleep (low-frequency coupling, LFC;0.01-0.1Hz) including all NREM-1 and portion of NREM-2 associated with sleep instability, characterized by variability in tidal volumes, blood pressure non-dipping and CAP on EEG, (3) Wake and rapid eye movement (REM) sleep (very low-frequency coupling characteristics, vLFC;0-0.01Hz). The device can identify potential sleep pathologies evidenced by activity in a subset of unstable sleep where two discernible bands emerge; (1) a broad-spectral-band e-LFC (eLFCBB), linked to sleep fragmentation and obstructive sleep apnoea and (2) a narrow-spectral-band e-LCC (eLFCNB) in the frequency range 0.0006 to 0.1Hz, indicative of putative central sleep apnoea, periodic breathing or complex sleep apnoea. These metrics are expressed as a percentage of analysis windows related to the total sleep period. Other SleepImage diagnostic parameters include the Sleep Quality Index (SQI) which is biomarker and objective score of overall sleep quality. SQI integrates sleep stability, fragmentation, sleep duration and sleep pathologies derived from CPC and is presented on a scale of 0-100, apnoea hypopnea index , hypoxic burden , sleep onset, sleep offset, sleep duration, total sleep time , wake after sleep onset and sleep efficiency. At a practical level, the SleepImage device is a single patient, multiple use device which can be posted to the patient's home. It thus permits a sleep study assessment on as frequent as a basis as the physician and patient wish within the home setting.
The aim of this feasibility study is to review the efficacy of the SleepImage diagnostic equipment as a predictor of ventilatory impairment. This will be determined by a sleep quality index SQI of <55 and Periodicity (eLFCNB) >2 showing an association with ventilatory failure.
The use of the SleepImage technology would not be to replace current diagnostic tests such as SNIP, VC, TcCO2 and blood gases, but instead used as an early screen tool. If a positive association can be made between SQI, Periodicity and ventilatory failure, then SleepImage technology could be used as a tool to expedite the process of hospital diagnostic tests to assess for ventilatory impairment. Furthermore, the SleepImage technology could be used once patients are established onto ventilation as a way of monitoring their ventilatory control on therapy.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Diagnosis of ALS without NIV | – | Device: SleepImage |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Amyotrophic Lateral Sclerosis
Key inclusion criteria (1 listed)
- Patients aged 18 and over with a Neurologist confirmed diagnosis of ALS
Key exclusion criteria (4 listed)
- Patients with known respiratory disease
- Unstable cardiac disease, stable hypertension or ischaemic heart disease
- Current NIV use
- Inability to give consent (expected ~15% due to frontotemporal dementia)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| SleepImageSleepImage Device | Device | Diagnosis of ALS without NIV |
Primary outcome
SQI & e-LFCNB>2
Time frame: 12 hours
We hypothesise that a SQI <55 and Periodicity e-LFCNB>2 has a positive association with an accepted indication for NIV initiation in ALS defined as: * Daytime Carbon Dioxide >6.0kPa and a rise of >1kPa from baseline in a time course consistent with REM sleep * Bicarbonate levels >32mmol/L * SNIP <40cmH20 in patients with non-bulbar disease * Supine fall in VC of 20% from erect in patient able to undertake the manoeuvre
1 secondary outcome
Hypoxic burden, T90, Pulse rate variability
Time frame: 12 hours
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 31 Mar 2026.
- Individual participant dataSharing planned: Undecided
Related trials for Amyotrophic Lateral Sclerosis
RecruitingPhase 1/2
Study is to Assess the Safety and Tolerability of VTx-002 in Participants With ALS
Amyotrophic Lateral Sclerosis
Not yet recruiting
A Study on the Addition of Alsum30 for the Treatment of Amyotrophic Lateral Sclerosis
Amyotrophic Lateral Sclerosis (ALS), Bacillus Coagulans
Active, not recruiting
Functional Outcomes and Control Using Synchron BCI - Australia
Neurologic Disorder, Neurologic Diseases
Not yet recruitingPhase 1
Safety, Tolerability, and Pharmacodynamic Exploration of Orelabrutinib in Patients With Amyotrophic Lateral Sclerosis (ALS)
Amyotrophic Lateral Sclerosis (ALS)
Recruiting
Clinical Outcome Assessment for AT & BCI
Spinal Cord Injury, ALS (Amyotrophic Lateral Sclerosis)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Lucy Redmond contact
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Amyotrophic Lateral Sclerosis, run by Royal Brompton & Harefield NHS Foundation Trust at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 31 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Professor Michael Polkey (020 7352 8121, mike.polkey@nhs.net), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
SQI & e-LFCNB>2 (time frame: 12 hours). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 31 Mar 2026.