This exploratory interventional study investigates dynamic prosthetic fit in unilateral transtibial prosthesis users by objectively measuring socket-leg interface movements (SLMs) during functional activities. Read more about this study

Who is it for?
Ages 16 years and older
Conditions the study is for
Transtibial Amputation - Unilateral
What is being tested?
Pin-Lock Suspension System, Passive Vacuum Suspension System and Active Vacuum Suspension System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteNorway
Study dates
20 Apr 2026to 27 Dec 2029
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 16 years and older
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • Age ≥16 years
  • Unilateral transtibial amputation
  • Activity level K2-K4
  • Actively using a prosthesis for ≥12 months
  • Ability to understand and communicate in Norwegian (oral and written)
  • Digital file of current socket model available (required for test socket fabrication)

Who cannot join

  • Use of a thigh corset attached to the prosthesis
  • Requirement of a walker for ambulation
  • Open wounds, skin ulcers, or blisters on the residual limb
  • No liner
  • Missing digital socket model file
  • Medical advice to avoid physical activity similar to study tasks
  • Other medical conditions that may worsen with activity and have not been cleared by a healthcare professional

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Karin Roeleveld, PhD contact

+47 48177279

karin.roeleveld@ntnu.no

Maria J Lequerica, MSc contact

+47 48684299

maria.j.lequerica@ntnu.no

Norway1 site
  • NTNU's Movement analysis laboratory at Helgasetr

    Trondheim, 7030

    Maria J Lequerica, MSc - PhD candidate, +47 48684299, maria.j.lequerica@ntnu.no

    Karin Roeleveld, PhD, +47 48177279, karin.roeleveld@ntnu.no

Other trials in Norway

About this study

Official title: Socket-leg Interface Movements as a Measure of Dynamic Prosthetic Fit for Transtibial Amputees: An Exploratory Study

This exploratory interventional study investigates dynamic prosthetic fit in unilateral transtibial prosthesis users by objectively measuring socket-leg interface movements (SLMs) during functional activities. During one single study visit, participants complete standardized laboratory tasks using three different suspension systems (pin-lock, passive vacuum, and active vacuum) applied to a transparent replica of their current prosthetic socket. Motion capture, force measurements, and patient-reported outcomes are used to evaluate how suspension systems influence interface motion, rotation resistance, gait characteristics, and user comfort. The study aims to improve clinical understanding of prosthetic fit and support more informed prosthetic decision-making in routine care.

Read the detailed description

Transtibial prosthetic fit strongly influences user comfort, gait quality, and long term functional outcomes. Current clinical assessment methods rely primarily on subjective clinical observation and user feedback. Dynamic socket-leg interface motion (SLM) offers an objective biomechanical indicator of prosthetic fit, but existing studies are limited in sample size, measurement directions, and evaluation across different suspension systems.

This study evaluates SLMs using 3D motion capture, force sensors, and a dynamometer while participants perform three standardized task categories:

isometric rotation tasks to determine rotation resistance and torque thresholds for interface rotation; turning/rotational/pivoting walking tasks to assess functional performance and transverse plane dynamics; and treadmill walking at multiple speeds to quantify proximal-distal pistoning and gait kinematics.

Each participant is tested using three suspension system conditions (pin-lock, passive vacuum, active vacuum), starting with their preferred suspension system followed by a counterbalanced order to minimize bias. A transparent "test socket" replicating the participant's own socket allows interface visualization and marker tracking without altering the intended use of the prosthesis. The investigational device consists only of CE marked components used within their intended purpose.

Participants attend one study visit with a duration of approximately 4 to 5 hours, including prosthesis adjustment and placement, marker setup, data collection across all three task categories and with all three suspension system conditions.

The primary aim is to quantify the effects of suspension system and load conditions on SLMs and gait performance. Secondary aims assess relationships between objective SLM measures and patient reported comfort, functional ability with the prosthesis, and prosthesis satisfaction. Findings will support improved understanding of dynamic fit behavior, help characterize suspension system performance, and inform future development of objective prosthetic fitting assessment methods.

Being tested
Pin-Lock Suspension System, Passive Vacuum Suspension System, Active Vacuum Suspension System
Keywords
Transtibial amputation, Lower-limb prosthesis, Prosthetic socket fit, 3D motion capture, Prosthesis comfort, Prosthetic rotation resistance, Pistoning, Prosthetic suspension systems, Prosthetic alignment, gait

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Pin-Lock Suspension SystemDevice

    Participants perform all tasks using a pin-lock suspension system applied to their test socket.

  • Passive Vacuum Suspension SystemDevice

    Participants perform all tasks using a passive vacuum suspension system applied to their test socket.

  • Active Vacuum Suspension SystemDevice

    Participants perform all tasks using an active vacuum suspension system applied to their test socket.

Study groups in NCT07521891
Study groupRoleWhat they receive
Single Cohort: Three Suspension SystemsExperimentalParticipants with unilateral transtibial amputation will attend one study visit at the research site. During this visit, they will complete three movement tasks-treadmill walking, overground turning, and isometric leg rotation-while using three different prosthetic suspension systems in a partly randomized order (pin lock, passive vacuum, and active vacuum). Each of the three movement tasks will be performed with each of the three suspension systems. Biomechanical, performance, and patient-reported outcomes will be recorded for each suspension condition.
Receives: Device: Pin-Lock Suspension System; Device: Passive Vacuum Suspension System; Device: Active Vacuum Suspension System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Socket-Liner Motion [mm]

    Socket-liner motion is quantified using a 3D optical motion-capture system to measure the relative movement between the prosthetic socket and liner during functional activities. Motion is recorded in millimeters (mm).

    Typical motion values are expected to fall within the range of 0-20 mm.

    Measured: Within 1 hour after fitting the suspension system

  2. Proximal-distal Socket-Leg Motion [mm]

    Proximal-distal Socket-Leg Motion is quantified using a 3D motion-capture system to measure the relative movement between the prosthetic socket and the remaining leg during functional activities. Motion is recorded in millimeters (mm).

    Typical motion values are expected to fall within the range of 0-30 mm.

    Measured: Within 1 hour after fitting the suspension system

Secondary outcomes (7)
  1. Torque Required to Initiate Socket-Liner Rotation [Nm]

    This measure quantifies the torque at which transverse rotation begins between the prosthetic socket and liner. Torque is measured in Newton-meters (Nm) using a dynamometer.

    Measured: Within 1 hour after fitting the suspension system

  2. Step length [cm]

    Step length is quantified using a 3D motion-capture system during functional activities. Step length is recorded in centimeters (cm).

    Measured: Within 1 hour after fitting the suspension system

  3. Step length asymmetry index

    Step length asymmetry will be assessed using 3D motion analysis instrumentation. Asymmetry is computed on step length (cm) of the prosthetic and intact legs, by dividing the difference between legs by the average of both legs. 0 marks perfect symmetry and greater values higher asymmetry. There is no maximum limit, but most values are expected to be below 1.

    Measured: Within 1 hour after fitting the suspension system

  4. Gait velocity [m/s]

    Gait velocity is quantified using a 3D motion-capture system during functional activities. Gait velocity is recorded in meters per second (m/s).

    Measured: Within 1 hour after fitting the suspension system

  5. Patient-Reported Socket Comfort Score (SCS)

    The Socket Comfort Score is a patient-reported numerical rating scale used to assess prosthetic socket comfort. Participants rate their comfort on a 0-10 scale, where 0 represents the most uncomfortable socket imaginable and 10 represents the most comfortable socket imaginable.

    Comfort is evaluated for each of the three suspension conditions. For every condition, the participant provides the score immediately after completing the turning task and treadmill-walking task, both performed within 60 minutes of fitting the corresponding suspension system.

    Measured: Within 1 hour after fitting the suspension system

  6. Perceived Functional Ability

    Perceived functional ability is assessed using a patient-reported numerical rating scale that captures the participant's subjective evaluation of how well they are able to perform functional activities with the prosthesis. Participants rate their perceived functional ability on a 0-10 scale, where 0 indicates the lowest perceived functional ability and 10 indicates the highest perceived functional ability.

    For each of the three suspension conditions, participants provide this rating immediately after completing the turning task and treadmill-walking task, both performed within 60 minutes of fitting the respective suspension system.

    Measured: Within 1 hour after fitting the suspension system

  7. Prosthesis Satisfaction Score

    The Prosthesis Satisfaction Score is a patient-reported numerical rating scale used to assess overall satisfaction with the prosthetic limb. Participants rate their satisfaction on a 0-10 scale, where 0 represents the lowest possible satisfaction and 10 represents the highest possible satisfaction.

    For each of the three suspension conditions, participants provide this rating immediately after completing the turning task and treadmill-walking task, both performed within 60 minutes of fitting the corresponding suspension system.

    Measured: Within 1 hour after fitting the suspension system

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Apr 2026
  2. Study start20 Apr 2026 (estimated)
  3. Primary completion27 Feb 2027 (estimated)
  4. Study completion27 Dec 2029 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Model description
All participants complete the same set of laboratory tasks under three suspension system conditions (pin-lock, passive vacuum, active vacuum). The sequence of conditions is partly determined by the participant's current or preferred suspension system, which is always tested first, and partly counterbalanced for the remaining two suspension systems to reduce order effects. Each participant serves as their own control.
Masking
None (open label)
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07521891
Sponsor's protocol ID
938884
Acronym
SLMinTTA
Status last verified
Apr 2026
First submitted
5 Mar 2026
Last updated
13 Apr 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data (IPD) from this study cannot be shared because the data are not anonymous. According to REK regulations and GDPR requirements, the research team must retain the identification key for as long as the data are used for research purposes. As long as this key exists, the dataset is considered identifiable, and sharing identifiable or potentially re-identifiable data externally is not permitted. Therefore, IPD cannot be shared.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in