Complete EdentulismNCT07525011
Comparative Study of Denture Fabrication Techniques
A study testing Traditional Complete Denture Fabrication and Easdent Digital Complete Denture Fabrication in people with Complete Edentulism, run by Rutgers, The State University of New Jersey at 1 site in United States.
Trial summary
This study is a randomized, single-blinded clinical study conducted in the predoctoral clinic at Rutgers School of Dental Medicine. The purpose of this study is to compare a traditional complete denture fabrication technique with the Easdent digital complete denture workflow. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Complete Edentulism
- What is being tested?
- Traditional Complete Denture Fabrication and Easdent Digital Complete Denture Fabrication
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 20 participants
- Where
- 1 siteUnited States
- Study dates
- 30 Apr 2026to 30 May 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adults aged 18 years or older.
- Requiring new dual-arch complete dentures.
- Willing and able to attend for all required study appointments, including delivery and follow-up visits.
Who cannot join
- Requiring only single-arch complete dentures.
- Presence of severe medical conditions that would preclude attendance at multiple prosthodontic appointments.
- Active, untreated oral mucosal disease that would prevent impression making or denture fabrication.
- Severely resorbed edentulous ridges.
- Unable or unwilling to attend for all scheduled study visits or follow-up appointments.
- Unable to comply with instructions necessary for denture treatment or study procedures.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
United States1 site
Rutgers, School of Dental Medicine
Newark, New Jersey, 07103
Hua Zhu, DMD, PhD, MD, 9739724615, zhuhu1@sdm.rutgers.edu
Heba Elkassaby, BDS, DMD, MDSc, FACP, 973-972-6997, hte9@sdm.rutgers.edu
About this study
Official title: Comparative Study of Traditional Complete Denture Fabrication Technique and the Easdent Digital Complete Denture Fabrication Technique in a Predoctoral Dental Clinic
This study is a randomized, single-blinded clinical study conducted in the predoctoral clinic at Rutgers School of Dental Medicine. The purpose of this study is to compare a traditional complete denture fabrication technique with the Easdent digital complete denture workflow. The Easdent technique is a modification of the conventional method and utilizes FDA-approved materials and 3D-printed trays designed to record teeth position, jaw relations and impression information. Participants who require new dual-arch complete dentures will receive dentures fabricated using both techniques. The order of fabrication and delivery will be randomized. Clinical chair time, number of appointments, and total treatment time will be recorded. Patient-reported outcomes will be assessed using a modified OHIP-EDENT survey and preference questions after completion of both dentures. Student participants will also complete surveys evaluating learning experience and clinical usability. The study does not evaluate the safety or effectiveness of a drug or investigational device. All materials used are FDA-cleared and routinely used in clinical practice. The overall aim is to evaluate efficiency, patient satisfaction, and educational usability of the two denture fabrication workflows.
Read the detailed description
Complete dentures remain a common treatment for fully edentulous patients. The traditional complete denture fabrication workflow requires multiple clinical visits, including preliminary impressions, custom tray fabrication, border molding, final impressions, record base and wax rim fabrication, jaw relation records, tooth try-in, and final delivery. This process is technique-sensitive, time-intensive, and may require numerous patient appointments. In predoctoral dental education settings, the complexity of the workflow can also contribute to variability in clinical efficiency and student learning experience. The Easdent digital complete denture workflow is a modification of the conventional technique. It incorporates 3D-printed trays fabricated from FDA-cleared medical-grade denture tray or try-in denture materials. These trays are designed with features similar to try-in dentures, including standardized tooth positioning and idealized intercuspation between maxillary and mandibular arches. Retention holes are incorporated to allow the use of conventional impression materials in a manner similar to traditional stock trays. The trays are produced in multiple standardized sizes to accommodate variation in jaw dimensions. The workflow is intended to streamline the recording of esthetics (such as midline and horizontal reference lines), occlusal vertical dimension, and maxillomandibular relationships while maintaining compatibility with conventional denture processing techniques. This study is designed to compare the traditional complete denture workflow with the Easdent digital complete denture workflow in a predoctoral clinical environment. The investigation focuses on efficiency, patient-reported outcomes, and educational usability rather than safety or effectiveness of a drug or investigational device. All materials used in this study are FDA-cleared and routinely used in standard dental practice. Participants who require new dual-arch complete dentures will receive dentures fabricated using both workflows. The order of fabrication and delivery will be randomized to reduce sequencing bias. The study uses a single-blinded design in which participants are not informed which denture corresponds to which fabrication method at the time of evaluation. After completion and adjustment of both dentures, participants will complete standardized patient-reported surveys and indicate their preference. Clinical efficiency metrics include the number of appointments required, chair time per visit, and total treatment duration associated with each workflow. These data are recorded prospectively by trained student researchers under faculty supervision. Standardization procedures, including calibration sessions and training lectures, are implemented to reduce inter-operator variability. Patient-reported outcomes are assessed using a modified OHIP-EDENT 19 questionnaire, supplemented with additional items evaluating esthetic satisfaction and overall satisfaction. Surveys are administered after an adaptation period following delivery of both dentures to allow patients to assess comfort, function, and esthetics. Preference data are collected after participants have experienced both prostheses. In addition to patient outcomes, the study evaluates the educational impact of the two workflows. Student researchers complete structured surveys assessing perceived learning difficulty, procedural complexity, and overall workflow usability. This component is intended to evaluate feasibility and integration of the modified workflow within a predoctoral dental curriculum. The anticipated risks are consistent with routine complete denture treatment and include temporary mucosal soreness, minor discomfort during impression procedures, temporary speech adaptation, and the potential need for post-insertion adjustments. No additional risks beyond standard denture treatment are introduced by study participation. The study is considered minimal risk. The findings of this study may provide data regarding clinical efficiency, patient-centered outcomes, and educational feasibility of a modified denture fabrication workflow in an academic clinical setting. Results may inform decisions regarding curriculum design and clinical workflow optimization in complete denture therapy.
- Conditions
- Complete Edentulism
- Being tested
- Traditional Complete Denture Fabrication, Easdent Digital Complete Denture Fabrication
- Keywords
- Complete Denture, Conventional Complete Denture, Digital Complete Denture, Edentulous Patients, Dental Education, Denture Workflow, Removable Prosthodontics
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Traditional Complete Denture FabricationProcedure or surgery
Conventional complete denture fabrication performed using standard clinical procedures, including preliminary impressions, custom tray fabrication, border molding, final impressions, record base and wax rim fabrication for recording occlusal vertical dimension and maxillomandibular relationship, tooth try-in appointment, denture processing, delivery, and post-insertion adjustments. All materials used are FDA-cleared and routinely utilized in standard dental practice.
Easdent Digital Complete Denture FabricationProcedure or surgery
Complete denture fabrication performed using the Easdent digital complete denture workflow. This technique incorporates 3D-printed trays fabricated from FDA-cleared medical-grade denture tray or try-in denture materials. The trays are designed with standardized tooth positioning and retention features to facilitate recording of esthetics, occlusal vertical dimension, and maxillomandibular relationships using conventional impression materials. Subsequent clinical and laboratory procedures follow standard denture processing methods, including denture fabrication, delivery, and post-insertion adjustments.
| Study group | Role | What they receive |
|---|---|---|
| Traditional Complete Denture Fabrication | Experimental | Participants receive complete dentures fabricated using the conventional complete denture workflow. Receives: Procedure: Traditional Complete Denture Fabrication |
| Easdent Digital Complete Denture Fabrication | Experimental | Participants receive complete dentures fabricated using the Easdent digital complete denture workflow utilizing 3D-printed trays. Receives: Procedure: Easdent Digital Complete Denture Fabrication |
What is being measured
The primary outcome is the main question the study is designed to answer.
Total Clinical Chair Time per Denture Fabrication Method
Total accumulated clinical chair time (in minutes) required to complete denture fabrication for each workflow, measured from initial impression appointment through final delivery and necessary adjustments.
Measured: From initial impression appointment to final denture delivery (approximately 1-4 months)
Secondary outcomes (1)
Patient-Reported Oral Health-Related Quality of Life (Modified Oral Health Impact Profile for Edentulous Adults Score)
Patient-reported outcomes will be measured using a modified version of the Oral Health Impact Profile for Edentulous Adults 19 questionnaire. This modified instrument consists of 22 items: the original 19 OHIP-EDENT questions plus 3 additional items assessing esthetic and overall satisfaction.
Each item is rated on a 5-point Likert scale, where 1 represents the minimum (poorest) score and 5 represents the maximum (best) score. Total scores are calculated by summing the responses to all 22 items, resulting in a possible score range from 22 (minimum) to 110 (maximum). A higher score indicates a better outcome (higher quality of life). Domain-specific subscores will also be calculated and reported.
Measured: From enrollment to the end of treatment, an average of 4 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Apr 2026
- Study start30 Apr 2026 (estimated)
- Primary completion30 Apr 2028 (estimated)
- Study completion30 May 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Complete EdentulismStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Model description
- This study uses a randomized crossover design. Each enrolled participant will receive two sets of complete dentures fabricated using two different workflows: the conventional complete denture technique and the Easdent digital complete denture workflow. The order in which the dentures are fabricated and delivered will be randomized to minimize sequence effects. After both dentures are completed and delivered, participants will evaluate each prosthesis following an adaptation period. Outcomes related to clinical efficiency and participant-reported measures will be collected for both workflows within the same individual, allowing each participant to serve as their own control.
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 20 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Rutgers, The State University of New Jersey
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Heba Elkassaby, BDS, DMD, MDSc, FACP, Rutgers, The State University of New Jersey
- Investigators
- Heba Elkassaby, DMD, MDSc, FACP, Principal investigator, Rutgers, The State University of New Jersey
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07525011
- Sponsor's protocol ID
- Pro2025002520
- Status last verified
- Apr 2026
- First submitted
- 12 Mar 2026
- Last updated
- 13 Apr 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 13 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparative Study of Traditional Complete Denture Fabrication Technique and the Easdent Digital Complete Denture Fabrication Technique in a Predoctoral Dental Clinic
- ClinicalTrials.gov ID
- NCT07525011
- Acronym / sponsor ID
- Pro2025002520
- Conditions
- Complete Edentulism
- Keywords
- Complete Denture, Conventional Complete Denture, Digital Complete Denture, Edentulous Patients, Dental Education, Denture Workflow, Removable Prosthodontics
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 20 participants (estimated)
- Lead sponsor
- Rutgers, The State University of New JerseyUniversity, hospital or other
- Study start
- 30 Apr 2026 (estimated)
- Primary completion
- 30 Apr 2028 (estimated)
- Study completion
- 30 May 2028 (estimated)
- First posted
- 13 Apr 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study is a randomized, single-blinded clinical study conducted in the predoctoral clinic at Rutgers School of Dental Medicine. The purpose of this study is to compare a traditional complete denture fabrication technique with the Easdent digital complete denture workflow. The Easdent technique is a modification of the conventional method and utilizes FDA-approved materials and 3D-printed trays designed to record teeth position, jaw relations and impression information. Participants who require new dual-arch complete dentures will receive dentures fabricated using both techniques. The order of fabrication and delivery will be randomized. Clinical chair time, number of appointments, and total treatment time will be recorded. Patient-reported outcomes will be assessed using a modified OHIP-EDENT survey and preference questions after completion of both dentures. Student participants will also complete surveys evaluating learning experience and clinical usability. The study does not evaluate the safety or effectiveness of a drug or investigational device. All materials used are FDA-cleared and routinely used in clinical practice. The overall aim is to evaluate efficiency, patient satisfaction, and educational usability of the two denture fabrication workflows.
Detailed description
Complete dentures remain a common treatment for fully edentulous patients. The traditional complete denture fabrication workflow requires multiple clinical visits, including preliminary impressions, custom tray fabrication, border molding, final impressions, record base and wax rim fabrication, jaw relation records, tooth try-in, and final delivery. This process is technique-sensitive, time-intensive, and may require numerous patient appointments. In predoctoral dental education settings, the complexity of the workflow can also contribute to variability in clinical efficiency and student learning experience. The Easdent digital complete denture workflow is a modification of the conventional technique. It incorporates 3D-printed trays fabricated from FDA-cleared medical-grade denture tray or try-in denture materials. These trays are designed with features similar to try-in dentures, including standardized tooth positioning and idealized intercuspation between maxillary and mandibular arches. Retention holes are incorporated to allow the use of conventional impression materials in a manner similar to traditional stock trays. The trays are produced in multiple standardized sizes to accommodate variation in jaw dimensions. The workflow is intended to streamline the recording of esthetics (such as midline and horizontal reference lines), occlusal vertical dimension, and maxillomandibular relationships while maintaining compatibility with conventional denture processing techniques. This study is designed to compare the traditional complete denture workflow with the Easdent digital complete denture workflow in a predoctoral clinical environment. The investigation focuses on efficiency, patient-reported outcomes, and educational usability rather than safety or effectiveness of a drug or investigational device. All materials used in this study are FDA-cleared and routinely used in standard dental practice. Participants who require new dual-arch complete dentures will receive dentures fabricated using both workflows. The order of fabrication and delivery will be randomized to reduce sequencing bias. The study uses a single-blinded design in which participants are not informed which denture corresponds to which fabrication method at the time of evaluation. After completion and adjustment of both dentures, participants will complete standardized patient-reported surveys and indicate their preference. Clinical efficiency metrics include the number of appointments required, chair time per visit, and total treatment duration associated with each workflow. These data are recorded prospectively by trained student researchers under faculty supervision. Standardization procedures, including calibration sessions and training lectures, are implemented to reduce inter-operator variability. Patient-reported outcomes are assessed using a modified OHIP-EDENT 19 questionnaire, supplemented with additional items evaluating esthetic satisfaction and overall satisfaction. Surveys are administered after an adaptation period following delivery of both dentures to allow patients to assess comfort, function, and esthetics. Preference data are collected after participants have experienced both prostheses. In addition to patient outcomes, the study evaluates the educational impact of the two workflows. Student researchers complete structured surveys assessing perceived learning difficulty, procedural complexity, and overall workflow usability. This component is intended to evaluate feasibility and integration of the modified workflow within a predoctoral dental curriculum. The anticipated risks are consistent with routine complete denture treatment and include temporary mucosal soreness, minor discomfort during impression procedures, temporary speech adaptation, and the potential need for post-insertion adjustments. No additional risks beyond standard denture treatment are introduced by study participation. The study is considered minimal risk. The findings of this study may provide data regarding clinical efficiency, patient-centered outcomes, and educational feasibility of a modified denture fabrication workflow in an academic clinical setting. Results may inform decisions regarding curriculum design and clinical workflow optimization in complete denture therapy.
Study design
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 2
- Model description
- This study uses a randomized crossover design. Each enrolled participant will receive two sets of complete dentures fabricated using two different workflows: the conventional complete denture technique and the Easdent digital complete denture workflow. The order in which the dentures are fabricated and delivered will be randomized to minimize sequence effects. After both dentures are completed and delivered, participants will evaluate each prosthesis following an adaptation period. Outcomes related to clinical efficiency and participant-reported measures will be collected for both workflows within the same individual, allowing each participant to serve as their own control.
| Arm | Type | Receives |
|---|---|---|
| Traditional Complete Denture Fabrication | Experimental | Procedure: Traditional Complete Denture FabricationParticipants receive complete dentures fabricated using the conventional complete denture workflow. |
| Easdent Digital Complete Denture Fabrication | Experimental | Procedure: Easdent Digital Complete Denture FabricationParticipants receive complete dentures fabricated using the Easdent digital complete denture workflow utilizing 3D-printed trays. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Adults aged 18 years or older.
- Requiring new dual-arch complete dentures.
- Willing and able to attend for all required study appointments, including delivery and follow-up visits.
Key exclusion criteria (6 listed)
- Requiring only single-arch complete dentures.
- Presence of severe medical conditions that would preclude attendance at multiple prosthodontic appointments.
- Active, untreated oral mucosal disease that would prevent impression making or denture fabrication.
- Severely resorbed edentulous ridges.
- Unable or unwilling to attend for all scheduled study visits or follow-up appointments.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Traditional Complete Denture FabricationConventional complete denture fabrication performed using standard clinical procedures, including preliminary impressions, custom tray fabrication, border molding, final impressions, record base and wax rim fabrication for recording occlusal vertical dimension and maxillomandibular relationship, tooth try-in appointment, denture processing, delivery, and post-insertion adjustments. All materials used are FDA-cleared and routinely utilized in standard dental practice. | Procedure or surgery | Traditional Complete Denture Fabrication |
| Easdent Digital Complete Denture FabricationComplete denture fabrication performed using the Easdent digital complete denture workflow. This technique incorporates 3D-printed trays fabricated from FDA-cleared medical-grade denture tray or try-in denture materials. The trays are designed with standardized tooth positioning and retention features to facilitate recording of esthetics, occlusal vertical dimension, and maxillomandibular relationships using conventional impression materials. Subsequent clinical and laboratory procedures follow standard denture processing methods, including denture fabrication, delivery, and post-insertion adjustments. | Procedure or surgery | Easdent Digital Complete Denture Fabrication |
Primary outcome
Total Clinical Chair Time per Denture Fabrication Method
Time frame: From initial impression appointment to final denture delivery (approximately 1-4 months)
Total accumulated clinical chair time (in minutes) required to complete denture fabrication for each workflow, measured from initial impression appointment through final delivery and necessary adjustments.
1 secondary outcome
Patient-Reported Oral Health-Related Quality of Life (Modified Oral Health Impact Profile for Edentulous Adults Score)
Time frame: From enrollment to the end of treatment, an average of 4 months
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 13 Apr 2026.
- Individual participant dataSharing planned: No
Related trials for Complete Edentulism
Recruiting
Accuracy of Complete-Arch Implant Scans Using Non Calibrated Splinting Scanbodies
Edentulism Complete
Active, not recruiting
Titanium Versus Nano-Carbon CAD/CAM Frameworks for All-on-4 Implant Supported Hybrid Prosthesis.
Complete Edentulism
Not yet recruiting
Comparison of Open-Mouth and Closed-Mouth Impression Techniques for Complete Dentures
Edentulism
Recruiting
Nutritional Intervention for Older Adults With Complete Dentures
Edentulism Complete, Denture, Complete
Recruiting
Microbial Adhesion and Peri-Implant Tissue Health in All-on-Four Hybrid Prostheses Supported by Zantex or Zirconia Frameworks
Complete Edentulism
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Heba Elkassaby, DMD, MDSc, FACP principal investigator
Rutgers, The State University of New Jersey
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Traditional Complete Denture Fabrication and Easdent Digital Complete Denture Fabrication in people with Complete Edentulism, run by Rutgers, The State University of New Jersey at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 13 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Heba Elkassaby, DMD, MDSc, FACP (973-972-6997, hte9@sdm.rutgers.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Total Clinical Chair Time per Denture Fabrication Method (time frame: From initial impression appointment to final denture delivery (approximately 1-4 months)). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Apr 2026.