AzTrials
AzTrials

Lung Cancer PatientSuction48NCT07527702

Low (-4) vs Physiologic (-8) Pressure Digital Continuous Suction After Lung Resection

A study testing Low-pressure digital suction (-4 cmH₂O) in people with Lung Cancer Patient, run by Seoul National University Hospital at 1 site in South Korea.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this clinical trial is to learn whether using a lower negative pressure (-4 cmH₂O) on a digital chest drainage device after lung resection reduces the time a chest tube must stay in place compared with the commonly used physiologic pressure (-8 cmH₂O), without increasing complications. Read more about this study

Who is it for?
Ages 19 years and older
Conditions the study is for
Lung Cancer Patient
What is being tested?
Low-pressure digital suction (-4 cmH₂O)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
160 participants
Where
1 siteSouth Korea
Study dates
3 Sep 2025to Jun 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 19 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adults ≥19 years of age.
  • Undergoing anatomical lung resection (segmentectomy or lobectomy) for confirmed or suspected primary lung cancer at a tertiary center.
  • Digital continuous suction device (Thopaz) used as the sole chest drainage system immediately after surgery.
  • Able to provide written informed consent on the day before surgery.
  • Randomization criterion (in-hospital): On postoperative day 1 (approximately 7-8 AM), a measurable air leak persists and the chest tube is not removed per routine care. Participants with no clinically meaningful air leak on POD1 (e.g., 0-10 mL/min per institutional criteria) will be considered screen failures and will not be assigned to an arm.

Who cannot join

  • Placement of two or more drains (e.g., additional chest tube or JP drain) during the index surgery.
  • Intraoperative or immediate postoperative serious complication requiring ICU care.
  • Change from the digital suction system to another drainage system prior to randomization or outcome assessment.
  • Any condition that, in the opinion of the investigator, makes participation inappropriate (e.g., inability to comply with study procedures or safety concerns).

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

SeonYong Bae, MD contact

82) + 010-3205-4460

bsy115s@naver.com

South Korea1 site, 1 recruiting
  • Seoul National University Hospital

    Seoul

    In Kyu Park, MD,PHD, 82)+10-3783-2653, ikpark@snu.ac.kr

    Recruiting

Other trials in South Korea

About this study

Official title: Efficacy and Safety of Low Pressure (-4cmH2O) Suction Compared With Physiologic Pressure (-8cmH2O) Suction Using Digital Continuous Suction System After Pulmonary Resection: A Prospective Randomized Controlled Open-label Study

The goal of this clinical trial is to learn whether using a lower negative pressure (-4 cmH₂O) on a digital chest drainage device after lung resection reduces the time a chest tube must stay in place compared with the commonly used physiologic pressure (-8 cmH₂O), without increasing complications. The trial enrolls adult patients undergoing segmentectomy or lobectomy for lung cancer at a tertiary medical center.

The main questions it aims to answer are:

Read more

Does the -4 cmH₂O setting shorten chest tube duration (primary outcome) compared with -8 cmH₂O?

What is the effect of -4 vs -8 cmH₂O on air-leak duration, length of hospital stay, and postoperative complications (e.g., pneumothorax, subcutaneous emphysema, re-intervention), and on the need for pleurodesis or suction readjustment, and 30-day readmission?

Researchers will compare patients assigned to -4 cmH₂O with patients assigned to -8 cmH₂O to see whether the lower pressure improves recovery after lung resection. The trial is prospective, randomized, open-label (two parallel arms; planned sample size ~160; 1:1 allocation). An interaction analysis will also explore whether effects differ between patients with lower vs higher air-leak flow on postoperative day (POD) 1.

Participants will:

Receive standard perioperative care for lung resection.

Provide written informed consent on the day before surgery following a discussion with study staff.

On POD#1 (approximately 7-8 AM), have air-leak flow measured by the digital device.

If no clinically meaningful air leak is present on POD#1 (e.g., 0-10 mL/min by institutional criteria) and the chest tube is likely to be removed, the participant will not be randomized and will continue standard care outside the comparative analysis (screen fail/observational record only).

If an air leak persists on POD#1, the participant will be randomized to -4 or -8 cmH₂O suction and the assigned setting will be maintained until chest tube removal, unless a clinical safety reason requires adjustment.

Undergo routine inpatient assessments already used in standard care (e.g., daily chest X-rays, recording of air-leak flow and drainage volume, monitoring for complications) until discharge.

The study uses a commercially available digital chest drainage system already employed in routine practice. Because it is open-label, neither clinicians nor participants are blinded to the pressure setting. If predefined safety signals occur (e.g., clear increases in complications or prolonged air leaks in one arm), the protocol allows suction adjustment for individual safety and interim review for potential early stopping, in accordance with institutional policies.

Being tested
Low-pressure digital suction (-4 cmH₂O)

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Low-pressure digital suction (-4 cmH₂O)Device

    A digital thoracic drainage device set to continuous suction at -4 cmH₂O, initiated on postoperative day 1 after randomization. The assigned suction pressure is maintained until chest tube removal unless predefined clinical safety criteria require adjustment. Air-leak flow and drainage volume are recorded as part of routine postoperative care.

Study groups in NCT07527702
Study groupRoleWhat they receive
Low-pressure digital suction (-4 cmH₂O)ExperimentalThopaz portable digital suction system - Low-pressure (-4 cmH₂O)
Receives: Device: Low-pressure digital suction (-4 cmH₂O)
Physiologic-pressure digital suction (-8 cmH₂O)No interventionA digital thoracic drainage device set to continuous suction at -8 cmH₂O, initiated on postoperative day 1 after randomization. The assigned suction pressure is maintained until chest tube removal unless predefined clinical safety criteria require adjustment. Air-leak flow and drainage volume are recorded as part of routine postoperative care.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Duration of postoperative air leak (days)

    Daily air-leak flow (mL/min) recorded by the digital chest drainage system (≈6 AM). Air-leak resolution is defined as no visible air leak or <10 mL/min sustained for ≥12 hours with adequate lung expansion on chest X-ray and stable clinical status. Duration is calculated in days from randomization (POD1) to resolution.

    Measured: Time Frame: From postoperative day 1 randomization to the date of air-leak resolution, assessed daily, up to 30 days postoperatively or until hospital discharge.

Secondary outcomes (1)
  1. Chest tube duration (days)

    Number of calendar days the chest tube remains in place during the index hospitalization.

    Measured: Time Frame: From the date of surgery to the date of chest tube removal, assessed during the index hospitalization for up to 30 postoperative days.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Apr 2026
  2. Study start3 Sep 2025
  3. Primary completionJun 2026 (estimated)
  4. Study completionJun 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
160 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07527702
Sponsor's protocol ID
2507-104-1658
Other IDs
04-2025-0420
Acronym
Suction48
Status last verified
Jan 2026
First submitted
24 Dec 2025
Last updated
14 Apr 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: No plan to share de-identified IPD due to institutional policy and/or consent constraints. Aggregate results will be published, and key study documents (e.g., protocol, SAP) may be made available upon reasonable request.

Questions about this trial

What is this clinical trial studying?

A study testing Low-pressure digital suction (-4 cmH₂O) in people with Lung Cancer Patient, run by Seoul National University Hospital at 1 site in South Korea.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 14 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in South Korea. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact SeonYong Bae, MD (82) + 010-3205-4460, bsy115s@naver.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Duration of postoperative air leak (days) (time frame: Time Frame: From postoperative day 1 randomization to the date of air-leak resolution, assessed daily, up to 30 days postoperatively or until hospital discharge.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Apr 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in