AzTrials
AzTrials

GlaucomaNCT07550712

A Study to Evaluate the Clinical Performance of VeriSee GLC for Screening of Glaucoma Suspect Using Color Fundus Images

An observational study of Glaucoma, run by Acer Medical Inc. at 1 site in Taiwan.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this observational study is to evaluate the clinical performance of VeriSee GLC for identifying glaucoma suspects using color fundus images in adult participants. The main questions it aims to answer are: What are the sensitivity and specificity of VeriSee GLC for detecting glaucoma suspects based on… Read more about this study

Who is it for?
Ages 20 years and older
Conditions the study is for
Glaucoma
How many people
773 participants
Where
1 siteTaiwan
Study dates
26 Aug 2024to 27 Dec 2024
Phase
Observational
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 years and older
  • All sexes
  • Adult, Older adult

Study population: The study population consisted of de-identified retrospective cases collected from National Taiwan University Hospital between February 1, 2022 and December 31, 2023. Cases were identified based on predefined ICD-10 code criteria, with exclusions applied for cataracts, acute angle-closure glaucoma, and prior ocular laser procedures. All cases were further screened according to predefined image inclusion and exclusion criteria, including image resolution, field of view, refractive status, and the visibility of the optic disc and retinal nerve fiber layer (RNFL), as determined by healthcare professionals. A total of 773 evaluable cases were included, of which 749 images were successfully analyzed by VeriSee GLC.

Who may be able to join

  • The adult color fundus image (aged 20 and above)
  • The requirements of color fundus image
  • The resolution of image is 1024 × 1024 pixels or higher;
  • The angle view of image is 45-or 50-degree.
  • Images captured from eyes with myopia not exceeding -10 diopters.
  • The color fundus image includes the optic disc and RNFL areas, and one of these areas is evaluable, as judged by the healthcare professionals.

Who cannot join

  • The color fundus images previously used by VeriSee GLC during the development process and pre-clinical test.
  • A color fundus image of patients with cataracts, acute angle closure glaucoma or those who have undergone retinal laser surgery.
  • The optic disc and RNFL areas in the color fundus images is invisible to determine the disease condition as judged by the healthcare professionals.

Trial locations and contacts

1 site in 1 country.

Taiwan1 site
  • National Taiwan University Hospital

    Taipei, 100

Other trials in Taiwan

About this study

The goal of this observational study is to evaluate the clinical performance of VeriSee GLC for identifying glaucoma suspects using color fundus images in adult participants. The main questions it aims to answer are:

  • What are the sensitivity and specificity of VeriSee GLC for detecting glaucoma suspects based on fundus images?
  • How does the performance of VeriSee GLC compare with the reference standard defined by the majority consensus of three independent evaluators?
Read more

Researchers will compare the screening results generated by VeriSee GLC with the reference standard to assess its diagnostic performance.

This retrospective study will use previously collected fundus images. VeriSee GLC performs automated image analysis to identify glaucomatous signs, including retinal nerve fiber layer (RNFL) defects, vertical cup-to-disc ratio (VCDR) enlargement, and rim-to-disc ratio (RDR) changes. The output is intended to assist healthcare professionals in identifying glaucoma suspects for referral, rather than providing a definitive diagnosis.

Conditions
Glaucoma
Keywords
Glaucoma suspect
Medical subject headings
Glaucoma, Ocular Hypertension

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sensitivity and Specificity of the VeriSee GLC for Screening Glaucoma Suspects

    The primary outcome is the sensitivity and specificity of the VeriSee GLC in identifying glaucoma suspects based on color fundus images, compared against the reference standard defined by the majority consensus of three independent evaluators.

    Measured: 1 Day

Secondary outcomes (4)
  1. Positive Predictive Value (PPV), Negative Predictive Value (NPV), and Accuracy of VeriSee GLC for Screening Glaucoma Suspects

    Evaluate the PPV, NPV, and overall accuracy of the VeriSee GLC in identifying glaucoma suspects relative to the reference standard.

    Measured: 1 Day

  2. Accuracy of Detection for 3 Glaucomatous Signs - VCDR and RDR

    Assess the accuracy of VeriSee GLC in detecting three glaucomatous signs:

    • Vertical cup-to-disc ratio (VCDR ≥ 0.7)
    • Rim-to-disc ratio (RDR ≤ 0.1)
    • Retinal nerve fiber layer (RNFL) defect

    Measured: 1 Day

  3. Accuracy of Detection for 3 Glaucomatous Signs - RNFL Defect

    Assess the accuracy of VeriSee GLC in detecting three glaucomatous signs:

    • Vertical cup-to-disc ratio (VCDR ≥ 0.7)
    • Rim-to-disc ratio (RDR ≤ 0.1)
    • Retinal nerve fiber layer (RNFL) defect

    Measured: 1 Day

  4. Dice Coefficient of Disc and Cup Contours

    Dice coefficient measures the similarity between contours generated by VeriSee GLC and evaluator annotations. The Dice coefficient ranges from 0 (no overlap) to 1 (perfect agreement).

    Measured: 1 Day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Apr 2026
  2. Study start26 Aug 2024
  3. Primary completion26 Aug 2024
  4. Study completion27 Dec 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Retrospective
Enrolment
773 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07550712
Sponsor's protocol ID
AMED2401
Status last verified
Apr 2026
First submitted
10 Apr 2026
Last updated
25 Jun 2026
Individual data sharing
No: Individual participant data (IPD) will not be shared due to data privacy considerations and institutional policy restrictions.

Questions about this trial

What is this clinical trial studying?

An observational study of Glaucoma, run by Acer Medical Inc. at 1 site in Taiwan.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 25 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Taiwan. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 25 Jun 2026). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sensitivity and Specificity of the VeriSee GLC for Screening Glaucoma Suspects (time frame: 1 Day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in