Retina PathologyOCTA & FANCT07568704
Image Evaluation of Intalight Dream OCTA Scans With Optos FA & ICGA Images
An observational study of Retina Pathology, run by Intalight, Inc at 1 site in United States.
Trial summary
The goal of this study is to evaluate the image quality and clinical utility of the OCTA images from the VG200D OCT device (investigational device) compared against the FA and ICGA images from the UWF Optos California (CA) device. Read more about this study
- Who is it for?
- Ages 22 years and older
- Conditions the study is for
- Retina Pathology
- What is being tested?
- Dream OCT
- Type of treatment
- Medical device
- How many people
- 30 participants
- Where
- 1 siteUnited States
- Study dates
- 25 Mar 2026to 31 Aug 2026
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 22 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients with retina pathology
Who may be able to join
- Subjects 22 years of age or older on the date of informed consent
- Subjects able to understand the written informed consent and willing to participate as evidenced by signing the informed consent
- BCVA 20/400 or better in the study eye
- Diagnosis of retinal associated pathology by investigator with the need to have an FA and/or ICGA performed in at least one eye
Who cannot join
- Subjects unable to tolerate ophthalmic imaging
- Subjects not able to obtain acceptable OCT images due to ocular media opacity or other reasons
- Subject has a condition or is in a situation which the investigator feels may put the subject at significant risk, may confound the study results, or may interfere significantly with the subject's participation in the study
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
United States1 site, 1 recruiting
- Recruiting
Retina Consultants of Texas
Houston, Texas, 77401
rebbecca Taing, BS, 713-394-7576, rebbecca.taing@retinaconsultantstexas.com
David Brown, MD
About this study
The goal of this study is to evaluate the image quality and clinical utility of the OCTA images from the VG200D OCT device (investigational device) compared against the FA and ICGA images from the UWF Optos California (CA) device. Image assessment will be conducted by three expert image graders and involve the assessment of the images based on both image quality and clinical utility. Evidence for substantial equivalence will be obtained through establishing similar image evaluation results across the devices based on image quality and clinical utility.
Read the detailed description
- Protocol Summary
The goal of this study is to evaluate the image quality and clinical utility of the OCTA images from the VG200D OCT device (investigational device) compared against the FA and ICGA images from the UWF Optos California (CA) device. Image assessment will be conducted by three expert image graders and involve the assessment of the images based on both image quality and clinical utility. Evidence for substantial equivalence will be obtained through establishing similar image evaluation results across the devices based on image quality and clinical utility.
Objectives and Endpoints
The primary objective is to evaluate image quality and clinical utility for visualization of the retinal vasculature from en-face OCTA scans between the VG200D and FA and ICGA images from the CA SLO device in eyes with retinal pathology.
The endpoint is the image grading results of the scans of the vascular structure of the retina in eyes with retinal associated pathology.
Methods
This is a prospective comparative study that will be conducted at one clinical site in the United States, in which subjects who sign an informed consent form and fulfil all inclusion and exclusion criteria will have images obtained using the investigational study device and the predicate device (VG200D and CA respectively).
This study will employ one VG200D device and one Optos CA device. At least one acceptable scan will be captured for each subject on each device. Scans will be assessed at the time of capture by the operator for acceptable quality, poor quality scans will be retaken. All scans will be saved and both acceptable and unacceptable scans will be recorded on the CRF. For FA and ICGA scans, the CA device captures multiple images over the time-course of the dye filling the arteries and veins, however the operator and/or investigator will review and choose the most clinically appropriate image to use for evaluation.
Subjects enrolled in this study will be confirmed to have retina associated pathology at the time of the study visit and will be in need of an FA and/or ICGA scan. Ocular status will be confirmed by a clinical examination during the study visit. Subjects enrolled may have more than one ocular pathology. Acceptable retina associated pathologies may include but are not limited to: Age-related macular degeneration, Diabetic Retinopathy with or without DME, and/or Vein or artery occlusions, that require FA or ICGA imaging.
If both eyes qualify, the study eye will be selected by the Investigator based on retinal pathology, where the study eye will have more significant pathology. If only one eye qualifies, that eye will be the study eye. Device imaging order will be randomized.
All scans are reviewed for acceptable image quality by the operator at the time of image acquisition based on user manual described criteria and as described in section 7.1.1 below. Operators will use the pre-defined, objective criteria described in section 7.1.1 below for how images are included into or excluded from the final data set and will be applied by the device operators using pre-defined image quality parameters, such as the signal strength (for OCTA images), poor illumination or contrast (for SLO images), presence of blinks, eye-movements, clipping, etc. These criteria will be applied to all scans at the time of capture by the operator and/or investigator. Acceptable scans will solely be determined by the operator and investigator. The number of scans that are rejected for all devices will be recorded in the CRF and the reasons for rejection will be provided. Image accountability of all scans will be reported in the final clinical study report.
The VG200D has more than one OCTA scan pattern available and all OCTA scan patterns for the VG200D will be captured for image evaluation. The first acceptable OCTA scan from each scan pattern captured will be used for the en-face OCTA visualization assessment.
The en-face OCTA images will be assessed and graded by three experienced graders and scored for image quality and clinical utility as compared to a similar grading of the Optos CA FA and ICGA images.
Image Grading
OCTA en-face images and FA and ICGA images will be exported and evaluated by three masked graders in a masked and randomized fashion for image quality and clinical utility. Image graders will have experience in both OCTA images and FA and ICGA images and will be independent from the clinical research site operator and investigator. Grading will be masked and randomized. Graders will work independently evaluating a single image at a time for the FA and/or ICGA images and will review all OCTA depth slabs for the OCTA scans. For OCTA scans, where multiple images at various depths are available, all depth scans (slabs) will be reviewed together for that patient and an overall image assessment will be provided (i.e., a Gestalt assessment will be made based on all images).
All graders will score each image for general image quality on a five-point scale from 0-5 where scores of 0 indicate image failure, 1 indicates very poor image quality, 2 indicates poor image quality, 3 indicates average image quality, 4 indicates good image quality, and 5 indicates excellent image quality. Scores of 0, 1 and 2 indicate the images have unacceptable image quality, and scores of 3, 4 and 5 indicate the images have acceptable image quality. In addition, images will be graded for clinical utility in helping to aid clinical decisions, such as viewing normal structures (confirming absence of pathology) or detecting pathological changes in the images (confirming pathology). The graders will evaluate clinical utility based on image content (e.g., identifying key vascular features such as the foveal avascular zone border, large-, medium-, and small-sized blood vessels, and blind-end capillaries; key pathologic vascular features such as microaneurysms, neovascular networks, telangiectasias, capillary dropout or nonperfusion, etc. En face depth sections (thickness slabs) from all available depths will be assessed together. The clinical utility or usefulness of OCTA images will also be graded on a five-point scale from 0-5 where scores of 0 indicate no clinical information is present, 1 indicates clinical information is very poor and not helpful, 2 indicates clinical information is poor and not helpful, 3 indicates clinical information is average but helpful, 4 indicates clinical information is good and helpful, and 5 indicates the clinical information present is excellent and very helpful. Scores of 0, 1 and 2 indicate the images are not clinically helpful and are considered unacceptable for providing useful clinical information. Scores of 3, 4 and 5 indicate the images are adding useful clinical information for aiding clinical decisions and are acceptable.
Planned Analyses
Results will be analyzed for differences using the non-parametric Wilcoxon signed rank test. In addition, the percentage agreement between each pair of readers will be determined by using 2x2 tables for the binary outcomes of acceptable vs. not acceptable.
Analysis of Safety Any adverse event (AE) associated with the VG200D or the predicate devices will be used to evaluate safety. Adverse event definitions and reporting requirements are provided in the study Protocol. All adverse events will be reported in the clinical study report.
- Conditions
- Retina Pathology
- Being tested
- Dream OCT
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Dream OCTDevice
This study employs the Dream OCT to image the eyes of patients with retina pathology
| Study group | Role | What they receive |
|---|---|---|
| Eyes with retina pathology | These are eyes with some type of retina pathology such as age-related macular degeneration, diabetic retinopathy, diabetic macula edema, and other retina pathologies Receives: Device: Dream OCT |
What is being measured
The primary outcome is the main question the study is designed to answer.
Image assessment of retinal images
The outcome measure is the image grading of retinal images including OCTA and FA and or ICGA images as graded by experts
Measured: All images and clinical study data will be collected in one clinical visit, which typically should take approximately 1 hour.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 May 2026
- Study start25 Mar 2026
- Primary completion15 Jul 2026 (estimated)
- Study completion31 Aug 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Retina PathologyStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 30 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Intalight, Inc
- Sponsor type
- Industry (pharma, biotech, devices)
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07568704
- Sponsor's protocol ID
- DREAM-CP2026-002
- Acronym
- OCTA & FA
- Status last verified
- Apr 2026
- First submitted
- 15 Apr 2026
- Last updated
- 6 May 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 6 May 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Image Evaluation of Intalight Dream OCTA Scans With Optos FA & ICGA Images
- ClinicalTrials.gov ID
- NCT07568704
- Acronym / sponsor ID
- OCTA & FA / DREAM-CP2026-002
- Conditions
- Retina Pathology
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 30 participants (estimated)
- Lead sponsor
- Intalight, IncIndustry (pharma, biotech, devices)
- Study start
- 25 Mar 2026 (actual)
- Primary completion
- 15 Jul 2026 (estimated)
- Study completion
- 31 Aug 2026 (estimated)
- First posted
- 6 May 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal of this study is to evaluate the image quality and clinical utility of the OCTA images from the VG200D OCT device (investigational device) compared against the FA and ICGA images from the UWF Optos California (CA) device. Image assessment will be conducted by three expert image graders and involve the assessment of the images based on both image quality and clinical utility. Evidence for substantial equivalence will be obtained through establishing similar image evaluation results across the devices based on image quality and clinical utility.
Detailed description
- Protocol Summary
The goal of this study is to evaluate the image quality and clinical utility of the OCTA images from the VG200D OCT device (investigational device) compared against the FA and ICGA images from the UWF Optos California (CA) device. Image assessment will be conducted by three expert image graders and involve the assessment of the images based on both image quality and clinical utility. Evidence for substantial equivalence will be obtained through establishing similar image evaluation results across the devices based on image quality and clinical utility.
Objectives and Endpoints
The primary objective is to evaluate image quality and clinical utility for visualization of the retinal vasculature from en-face OCTA scans between the VG200D and FA and ICGA images from the CA SLO device in eyes with retinal pathology.
The endpoint is the image grading results of the scans of the vascular structure of the retina in eyes with retinal associated pathology.
Methods
This is a prospective comparative study that will be conducted at one clinical site in the United States, in which subjects who sign an informed consent form and fulfil all inclusion and exclusion criteria will have images obtained using the investigational study device and the predicate device (VG200D and CA respectively).
This study will employ one VG200D device and one Optos CA device. At least one acceptable scan will be captured for each subject on each device. Scans will be assessed at the time of capture by the operator for acceptable quality, poor quality scans will be retaken. All scans will be saved and both acceptable and unacceptable scans will be recorded on the CRF. For FA and ICGA scans, the CA device captures multiple images over the time-course of the dye filling the arteries and veins, however the operator and/or investigator will review and choose the most clinically appropriate image to use for evaluation.
Subjects enrolled in this study will be confirmed to have retina associated pathology at the time of the study visit and will be in need of an FA and/or ICGA scan. Ocular status will be confirmed by a clinical examination during the study visit. Subjects enrolled may have more than one ocular pathology. Acceptable retina associated pathologies may include but are not limited to: Age-related macular degeneration, Diabetic Retinopathy with or without DME, and/or Vein or artery occlusions, that require FA or ICGA imaging.
If both eyes qualify, the study eye will be selected by the Investigator based on retinal pathology, where the study eye will have more significant pathology. If only one eye qualifies, that eye will be the study eye. Device imaging order will be randomized.
All scans are reviewed for acceptable image quality by the operator at the time of image acquisition based on user manual described criteria and as described in section 7.1.1 below. Operators will use the pre-defined, objective criteria described in section 7.1.1 below for how images are included into or excluded from the final data set and will be applied by the device operators using pre-defined image quality parameters, such as the signal strength (for OCTA images), poor illumination or contrast (for SLO images), presence of blinks, eye-movements, clipping, etc. These criteria will be applied to all scans at the time of capture by the operator and/or investigator. Acceptable scans will solely be determined by the operator and investigator. The number of scans that are rejected for all devices will be recorded in the CRF and the reasons for rejection will be provided. Image accountability of all scans will be reported in the final clinical study report.
The VG200D has more than one OCTA scan pattern available and all OCTA scan patterns for the VG200D will be captured for image evaluation. The first acceptable OCTA scan from each scan pattern captured will be used for the en-face OCTA visualization assessment.
The en-face OCTA images will be assessed and graded by three experienced graders and scored for image quality and clinical utility as compared to a similar grading of the Optos CA FA and ICGA images.
Image Grading
OCTA en-face images and FA and ICGA images will be exported and evaluated by three masked graders in a masked and randomized fashion for image quality and clinical utility. Image graders will have experience in both OCTA images and FA and ICGA images and will be independent from the clinical research site operator and investigator. Grading will be masked and randomized. Graders will work independently evaluating a single image at a time for the FA and/or ICGA images and will review all OCTA depth slabs for the OCTA scans. For OCTA scans, where multiple images at various depths are available, all depth scans (slabs) will be reviewed together for that patient and an overall image assessment will be provided (i.e., a Gestalt assessment will be made based on all images).
All graders will score each image for general image quality on a five-point scale from 0-5 where scores of 0 indicate image failure, 1 indicates very poor image quality, 2 indicates poor image quality, 3 indicates average image quality, 4 indicates good image quality, and 5 indicates excellent image quality. Scores of 0, 1 and 2 indicate the images have unacceptable image quality, and scores of 3, 4 and 5 indicate the images have acceptable image quality. In addition, images will be graded for clinical utility in helping to aid clinical decisions, such as viewing normal structures (confirming absence of pathology) or detecting pathological changes in the images (confirming pathology). The graders will evaluate clinical utility based on image content (e.g., identifying key vascular features such as the foveal avascular zone border, large-, medium-, and small-sized blood vessels, and blind-end capillaries; key pathologic vascular features such as microaneurysms, neovascular networks, telangiectasias, capillary dropout or nonperfusion, etc. En face depth sections (thickness slabs) from all available depths will be assessed together. The clinical utility or usefulness of OCTA images will also be graded on a five-point scale from 0-5 where scores of 0 indicate no clinical information is present, 1 indicates clinical information is very poor and not helpful, 2 indicates clinical information is poor and not helpful, 3 indicates clinical information is average but helpful, 4 indicates clinical information is good and helpful, and 5 indicates the clinical information present is excellent and very helpful. Scores of 0, 1 and 2 indicate the images are not clinically helpful and are considered unacceptable for providing useful clinical information. Scores of 3, 4 and 5 indicate the images are adding useful clinical information for aiding clinical decisions and are acceptable.
Planned Analyses
Results will be analyzed for differences using the non-parametric Wilcoxon signed rank test. In addition, the percentage agreement between each pair of readers will be determined by using 2x2 tables for the binary outcomes of acceptable vs. not acceptable.
Analysis of Safety Any adverse event (AE) associated with the VG200D or the predicate devices will be used to evaluate safety. Adverse event definitions and reporting requirements are provided in the study Protocol. All adverse events will be reported in the clinical study report.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Eyes with retina pathology | – | Device: Dream OCTThese are eyes with some type of retina pathology such as age-related macular degeneration, diabetic retinopathy, diabetic macula edema, and other retina pathologies |
Who may qualify
- Ages
- 22 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Patients with retina pathology
Key inclusion criteria (4 listed)
- Subjects 22 years of age or older on the date of informed consent
- Subjects able to understand the written informed consent and willing to participate as evidenced by signing the informed consent
- BCVA 20/400 or better in the study eye
- Diagnosis of retinal associated pathology by investigator with the need to have an FA and/or ICGA performed in at least one eye
Key exclusion criteria (3 listed)
- Subjects unable to tolerate ophthalmic imaging
- Subjects not able to obtain acceptable OCT images due to ocular media opacity or other reasons
- Subject has a condition or is in a situation which the investigator feels may put the subject at significant risk, may confound the study results, or may interfere significantly with the subject's participation in the study
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Dream OCTThis study employs the Dream OCT to image the eyes of patients with retina pathology | Device | Eyes with retina pathology |
Primary outcome
Image assessment of retinal images
Time frame: All images and clinical study data will be collected in one clinical visit, which typically should take approximately 1 hour.
The outcome measure is the image grading of retinal images including OCTA and FA and or ICGA images as graded by experts
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 May 2026.
- Individual participant dataSharing planned: No
Related trials for Retina Pathology
RecruitingObservational study
Familial Mediterranean Fever and Related Disorders: Genetics and Disease Characteristics
Familial Mediterranean Fever (FMF), Autoinflammation
Not yet recruitingPhase 2
A Study to Evaluate the Efficacy and Safety of VIS-101 in Participants With Neovascular Age-Related Macular Degeneration
Neovascular Age Related Macular Degeneration(nAMD)
Recruiting
Brain Stimulation Effects on Orientation and Mobility Skills in Adults With Vision Impairment
Retinitis Pigmentosa (RP), Rod Cone Dystrophy
Recruiting
Light Bulb Stimuli to Reduce Chronic Pain
Fibromyalgia, Musculoskeletal Pain
Recruiting
Chromatic Retinal Stimulation to Reduce Chronic Pain and Pain Sensitivity
Chronic Low-back Pain, Chronic Pain
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Retina Pathology, run by Intalight, Inc at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 6 May 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Mike Sinai, PhD (6198067636, mike.sinai@intalight.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Image assessment of retinal images (time frame: All images and clinical study data will be collected in one clinical visit, which typically should take approximately 1 hour.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 May 2026.