AzTrials
AzTrials

CancerHELIOSNCT07572318

Pilot Study on the Feasibility of High-energy Collimation With Optimized Geometry on a VERITON™ CZT Camera

A study testing Scintigraphy VERITON, Scintigraphy VERITON with new collimator and Scintigraphy SYMBIA in people with Cancer, run by Central Hospital, Nancy, France.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

Functional imaging using scintigraphy plays a major role in the diagnosis and monitoring of many diseases, particularly thanks to its ability to perform whole-body examinations with high contrast. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Cancer
What is being tested?
Scintigraphy VERITON, Scintigraphy VERITON with new collimator and Scintigraphy SYMBIA
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
18 participants
Where
No sites listed yet
Study dates
1 May 2026to 1 May 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • patients with multiple known lesions (≥ 2 metastases or lesions of other types) who, as part of their clinical management, require either (i) a 99mTc-HDP bone scan, or (ii) a post-therapeutic 177Lu-PSMA scan, or (iii) a post-therapeutic 131I scintigraphy.
  • Person who has undergone a preliminary clinical examination appropriate for clinical research.
  • Adult subject who has received complete information about the research and has signed the informed consent form.
  • General condition, WHO ≤ 2, and ability to remain lying down without moving for nearly an hour.

Who cannot join

  • Subjects with a contraindication, according to the target examination group, to injection of 99mTc-HDP (Technescan HDP, Curium Pharma), 177Lu-PSMA (Pluvicto®, Novartis), or 131I (131I sodium iodide for therapy, Curium Pharma) .
  • Subjects covered by Articles L. 1121-5, L. 1121-7, and L1121-8 of the Public Health Code.
  • Pregnant women, women in labor, or breastfeeding mothers.
  • Subjects subject to legal protection measures (guardianship, curatorship, judicial protection).
  • Subjects unable to give their consent.
  • Subjects deprived of their liberty by a judicial or administrative decision, persons receiving psychiatric care pursuant to Articles L. 3212-1 and L.3213-1.

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Anne-Sophie Hue Project Manager, MSc contact

+33.3.83.15.34.75

a.hue@chru-nancy.fr

About this study

Functional imaging using scintigraphy plays a major role in the diagnosis and monitoring of many diseases, particularly thanks to its ability to perform whole-body examinations with high contrast. The indications and use of scintigraphy have increased in recent years, particularly in connection with the development of internal vectorized radiotherapy. This therapeutic approach is based on the administration of radiotracers that enable targeted irradiation of tumor cells, whose biodistribution throughout the body can be analyzed and quantified using scintigraphy, particularly with iodine-131 and lutetium-177.

The recent boom in scintigraphy is also linked to the development of new 360° geometry CZT-SPECT cameras, which enable rapid tomographic acquisitions of the entire body with significantly improved image quality compared to conventional cameras. These systems use mobile CZT semiconductor detectors that dynamically scan the anatomical regions of interest.

CZT detectors are combined with a collimation system consisting of tungsten septa, which are essential for the directional filtering of gamma photons. Unlike conventional scintigraphic cameras, where collimators can be changed or adjusted according to the energy of the detected photons, CZT-SPECT 360° cameras generally rely on fixed collimation, which cannot be changed.

Read the detailed description

Functional imaging using scintigraphy plays a major role in the diagnosis and monitoring of many diseases, particularly thanks to its ability to perform whole-body examinations with high contrast. The indications and use of scintigraphy have increased in recent years, particularly in connection with the development of internal vectorized radiotherapy. This therapeutic approach is based on the administration of radiotracers that enable targeted irradiation of tumor cells, whose biodistribution throughout the body can be analyzed and quantified using scintigraphy, particularly with iodine-131 and lutetium-177.

The recent boom in scintigraphy is also linked to the development of new 360° geometry CZT-SPECT cameras, which enable rapid tomographic acquisitions of the entire body with significantly improved image quality compared to conventional cameras. These systems use mobile CZT semiconductor detectors that dynamically scan the anatomical regions of interest.

CZT detectors are combined with a collimation system consisting of tungsten septa, which are essential for the directional filtering of gamma photons. Unlike conventional scintigraphic cameras, where collimators can be changed or adjusted according to the energy of the detected photons, CZT-SPECT 360° cameras generally rely on fixed collimation, which cannot be changed.

Conditions
Cancer
Being tested
Scintigraphy VERITON, Scintigraphy VERITON with new collimator, Scintigraphy SYMBIA
Keywords
scintigraphy, scintigraphy post therapeutic
Medical subject headings
Neoplasms

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Scintigraphy VERITONDevice

    Full-body 3D recording on the VERITON™ 400 camera

  • Scintigraphy VERITON with new collimatorDevice

    • Whole-body 3D recording on the VERITON™ 400 camera equipped with conventional collimators for technetium-99m and lutetium-177.
  • Scintigraphy SYMBIADevice

    Whole-body 2D and cervicothoracic 3D recordings using an Anger camera (SYMBIA camera, Siemens Healthineers) for iodine-131 images.

Study groups in NCT07572318
Study groupRoleWhat they receive
VERITON-CT NewExperimentalOptimized collimators for the CZT detectors of the VERITON™ 400 wide-field camera (Spectrum Dynamics Medical) enabling better selection of incident photons
Receives: Device: Scintigraphy VERITON with new collimator
RéférenceActive comparator* Full-body 3D recording on the VERITON™ 400 camera equipped with conventional collimators for technetium-99m and lutetium-177. * 2D whole-body and 3D cervicothoracic recordings on an Anger camera (SYMBIA camera, Siemens Healthineers) for iodine-131 images.
Receives: Device: Scintigraphy VERITON; Device: Scintigraphy SYMBIA

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Feasability of whole-body SPECT/CT imaging with iodine-131 using the optimized collimator

    Data analysis obtained with optimized collimator and with conventional collimator

    Measured: 1 month

  2. Perform quantitative analysis of technetium-99m and lutetium-177 with feasability results

    Image sharpness improvment

    Measured: 1 month

Secondary outcomes (2)
  1. Overall quality of whole-body CZT acquisitions with iodine-131

    For iodine-131, the overall quality of images acquired using the CZT-SPECT camera with the new collimator will be described based on an ordinal score for stellar artifacts (absent, present but not interfering, present and interfering), assessed independently by two experienced readers. The frequency and severity of artifacts will be reported, as well as their association with the interpretable or non-interpretable nature of the examinations defined in the primary endpoint. Inter-reader agreement will also be described.

    Measured: 1 month

  2. Quantify the detectability and contrast of lesions visualized on whole-body CZT imaging with iodine-131.

    Sharpness, defined as the maximum slope of the intensity profile at the edge of the lesions and the contrast-to-noise ratio

    Measured: 1 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 May 2026
  2. Study start1 May 2026 (estimated)
  3. Primary completion1 Sep 2026 (estimated)
  4. Study completion1 May 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
18 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07572318
Sponsor's protocol ID
2026-A00456-45
Acronym
HELIOS
Status last verified
May 2026
First submitted
24 Feb 2026
Last updated
7 May 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Scintigraphy VERITON, Scintigraphy VERITON with new collimator and Scintigraphy SYMBIA in people with Cancer, run by Central Hospital, Nancy, France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 7 May 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Anne-Sophie Hue Project Manager, MSc (+33.3.83.15.34.75, a.hue@chru-nancy.fr), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Feasability of whole-body SPECT/CT imaging with iodine-131 using the optimized collimator (time frame: 1 month). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 May 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in