AzTrials
AzTrials

Edentulism CompletePrintowNCT07585162

PRINTOW: Occlusal Wear of Denture Teeth in Digitally Fabricated Complete Dentures

A study testing CAD/CAM-Milled Denture Base with Milled Denture Teeth, CAD/CAM-Milled Denture Base with Prefabricated Denture Teeth and 3D-printed denture base and teeth in people with Edentulism Complete and Edentulism, run by Najla Chebib.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record

Search all trials

Trial summary

This randomized controlled trial evaluates the occlusal wear of denture teeth fabricated using three digital workflows: 3D-printed denture teeth, CAD/CAM-milled double cross-linked denture teeth, and prefabricated denture teeth. Occlusal wear will be assessed over 24 months using digital superimposition techniques. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Edentulism Complete, Edentulism
What is being tested?
CAD/CAM-Milled Denture Base with Milled Denture Teeth, CAD/CAM-Milled Denture Base with Prefabricated Denture Teeth and 3D-printed denture base and teeth
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
45 participants
Where
No sites listed yet
Study dates
1 Sep 2026to 30 Dec 2032
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Written informed consent provided by the participant
  • Age ≥ 18 years
  • Fully edentulous maxilla and mandible requiring rehabilitation with new complete removable dental prostheses
  • Patients with or without mandibular implants (implant overdenture or conventional denture)
  • Clinical indication for fabrication of new maxillary and mandibular complete removable dental prostheses
  • Currently wearing complete dentures, or a maxillary denture combined with a mandibular denture or overdenture
  • Ability and willingness to attend all scheduled follow-up visits for the duration of the study

Who cannot join

  • Contraindications to the medical devices used, e.g. known hypersensitivity or allergy;
  • Known or suspected non-compliance, drug or alcohol abuse; Inability to follow the procedures of the investigation;
  • Enrolment of the investigator, his/her family members, employees and other dependent persons;
  • Reported severe bruxism or clenching habits, identified through patient interview and clinical examination, including self-reported grinding or clenching, partner reports, morning jaw discomfort, and other signs of parafunctional activity;
  • Width of the edentulous maxilla >80 mm;
  • Width of the edentulous mandible >80 mm; Vertical prosthetic space <38 mm (maxilla or mandible);
Show all 12Show fewer
  • Depression: Geriatric Depression Scale >9;
  • Xerostomia: UFR ≤ 0.2ml/2min;
  • Dementia: Clock-Drawing Test ≤5;
  • Active peri-implant disease or instability of the two mandibular implants at baseline when implants are present;
  • Presence of an implant-retained prosthesis in the maxilla;
  • Planned implant-related surgical intervention during the study period.

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Najla Chebib, PD Dr med dent contact

+41223794098

najla.chebib@unige.ch

Alessio Casucci, Dr Phd contact

+41223794060

Alessio.Casucci@unige.ch

About this study

Official title: A Randomized, Double-Blind, Three-Arm Superiority Trial Comparing Occlusal Wear of 3D-Printed, CAD/CAM-Milled, and Prefabricated Denture Teeth in Digitally Fabricated Complete Dentures in Edentulous Patients

This randomized controlled trial evaluates the occlusal wear of denture teeth fabricated using three digital workflows: 3D-printed denture teeth, CAD/CAM-milled double cross-linked denture teeth, and prefabricated denture teeth. Occlusal wear will be assessed over 24 months using digital superimposition techniques. The study aims to determine whether 3D-printed denture teeth demonstrate superior wear resistance compared to CAD/CAM-milled denture teeth.

Read the detailed description

This is a single-center, prospective, randomized, controlled, double-blind clinical investigation comparing three digitally fabricated complete removable dental prosthesis workflows in edentulous patients. The study will be conducted at the University Clinics of Dental Medicine, University of Geneva.

The study includes adult patients who are completely edentulous in the maxillary and mandibular arches and require new complete removable dental prostheses. Participants may be rehabilitated with either a conventional mandibular complete denture or a mandibular implant overdenture supported by clinically stable implants. This inclusion strategy is intended to improve recruitment feasibility and reflect real-world clinical practice. Mandibular prosthetic status at baseline will be used as a stratification factor during randomization and will be accounted for in the statistical analysis.

A total of 48 participants** will be randomized in a 1:1:1 allocation ratio to one of three treatment groups: fully 3D-printed complete dentures with printed denture base and printed denture teeth; CAD/CAM-milled complete dentures with milled double cross-linked denture teeth; or CAD/CAM-milled complete dentures with prefabricated denture teeth, serving as a clinical benchmark group.

The primary objective is to compare occlusal wear performance of denture teeth between the fabrication workflows. The primary confirmatory comparison will be conducted between the fully 3D-printed workflow and the CAD/CAM-milled double cross-linked workflow. Occlusal wear will be assessed by three-dimensional digital superimposition of intraoral scans acquired at baseline and follow-up visits. The primary endpoint is the average negative deviation of occlusal surfaces at 24 months, representing material loss over time.

> Secondary outcomes include root mean square surface deviation, patient-reported outcomes assessed with the Oral Health Impact Profile for Edentulous Patients and the Denture Satisfaction Index, chewing efficiency, bite force, prosthetic retention, color stability, prosthesis-related costs, maintenance interventions, and prosthetic complications. These outcomes will be assessed according to the study schedule at baseline and during follow-up visits at 12, 24, and 60 months.

Participants and outcome assessors will be blinded to denture fabrication workflow and denture tooth material allocation. Prostheses will be labeled using anonymized codes, and digital files used for wear analysis will be anonymized using participant study ID and time point. Treating clinicians and laboratory personnel will not be blinded due to the nature of the intervention, but they will not be involved in blinded outcome assessment.

All prostheses will be fabricated according to standardized clinical and laboratory procedures using CE-marked medical devices and materials according to the manufacturers' instructions for use. The prosthetic treatment phase will include clinical evaluation, impressions, intermaxillary records, prototype try-in, and delivery of the final prostheses. Follow-up assessments will be performed after prosthesis delivery to evaluate clinical, functional, patient-reported, material-related, and maintenance outcomes.

Being tested
CAD/CAM-Milled Denture Base with Milled Denture Teeth, CAD/CAM-Milled Denture Base with Prefabricated Denture Teeth, 3D-printed denture base and teeth
Keywords
Edentulism, Complete dentures, Digital dentistry, 3D printing, CAD/CAM, Occlusal wear, Denture teeth, Randomized controlled trial
Medical subject headings
Tooth Attrition

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CAD/CAM-Milled Denture Base with Milled Denture TeethDevice

    Complete removable dental prostheses fabricated using a digital workflow with CAD/CAM milling. Both the denture base and denture teeth are produced by subtractive manufacturing from pre-polymerized resin materials, including double cross-linked denture teeth, and assembled.

  • CAD/CAM-Milled Denture Base with Prefabricated Denture TeethDevice

    Complete removable dental prostheses fabricated using a digital workflow with CAD/CAM-milled denture bases combined with conventionally manufactured prefabricated denture teeth. The prefabricated teeth are selected and positioned digitally or manually and then bonded to the milled denture base.

  • 3D-printed denture base and teethDevice

    Description Complete removable dental prostheses fabricated using a fully digital workflow in which both the denture base and denture teeth are produced by 3D printing using light-curing resin materials. The prostheses are designed digitally and manufactured additively.

Study groups in NCT07585162
Study groupRoleWhat they receive
3D-printed denture base and teethExperimentalParticipants receive complete removable dental prostheses fabricated using a fully digital workflow with both the denture base and denture teeth produced by 3D printing.
Receives: Device: 3D-printed denture base and teeth
CAD/CAM-Milled Denture Base with Milled Denture TeethActive comparatorComplete dentures fabricated with CAD/CAM-milled denture bases and CAD/CAM-milled denture teeth
Receives: Device: CAD/CAM-Milled Denture Base with Milled Denture Teeth
CAD/CAM-Milled Denture Base with Prefabricated Denture TeethActive comparatorParticipants receive complete removable dental prostheses fabricated using a digital workflow with CAD/CAM-milled denture bases and conventionally manufactured prefabricated denture teeth. Conventional clinical reference.
Receives: Device: CAD/CAM-Milled Denture Base with Prefabricated Denture Teeth

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Occlusal Wear of Denture Teeth

    Occlusal wear of denture teeth will be assessed using three-dimensional digital superimposition of intraoral scans acquired at baseline and follow-up visits. Wear will be quantified as the average negative deviation (-AVG) between superimposed surfaces, expressed in micrometers (µm), representing material loss over time.

    Measured: from baseline to 24 month

Secondary outcomes (10)
  1. Surface Deviation (Root Mean Square, RMS)

    Surface deviation will be quantified using root mean square (RMS) values derived from three-dimensional superimposition of intraoral scans, providing a global measure of surface change.

    Measured: from baseline to 12, 24 and 60 months

  2. Maximum Bite Force

    Maximum bite force will be measured using a digital bite force device, expressed in Newtons (N).

    Measured: at Baseline, 12, 24, and 60 months

  3. Chewing Efficiency

    Chewing efficiency will be assessed using a standardized two-color mixing test, quantified as variance of hue (VOH).

    Measured: at baseline, 12, 24, and 60 months

  4. Oral Health-Related Quality of Life

    Patient-reported oral health-related quality of life will be assessed using the OHIP-EDENT questionnaire. The OHIP-EDENT questionnaire consists of 19 items assessing oral health-related quality of life in edentulous patients. Each item is scored on a 5-point Likert scale (0 = never to 4 = very often), with a total score ranging from 0 to 76. Higher scores indicate worse oral health-related quality of life.

    Measured: at baseline, 12, 24, 60 months

  5. Denture Satisfaction

    Patient satisfaction with dentures will be assessed using a validated questionnaire. Denture satisfaction will be assessed using a Visual Analog Scale (VAS) ranging from 0 to 10, where 0 indicates no satisfaction and 10 indicates maximum satisfaction. Higher scores reflect greater patient satisfaction with the prosthesis.

    Measured: at baseline, 12, 24, and 60 months

  6. Denture Retention

    Retention of the maxillary denture bases will be assessed by measuring the force required to dislodge the prosthetic base from the denture-bearing tissues. A digital dynamometer will be attached to a standardized central hook incorporated into the test base. The base will be seated intraorally, and a controlled vertical traction force will be applied until dislodgement occurs. The maximum force required to dislodge the base will be recorded in Newtons (N). Higher values indicate greater denture base retention.

    Measured: at baseline

  7. Color Stability

    Color changes of denture teeth will be assessed using colorimetric measurements and expressed as ΔE values.

    Measured: at baseline, 12, 24, and 60 months

  8. Total prosthesis fabrication cost

    Costs related to prosthesis fabrication will be recorded for each study group. This will include initial laboratory fabrication costs in swiss francs CHF per participant.

    Measured: at baseline,

  9. Number of Prosthetic Maintenance Visits

    The number of additional prosthesis-related maintenance visits required after prosthesis delivery will be recorded for each participant. Maintenance visits may include visits for adjustment, repair, relining, or management of prosthetic complications. it will be measured as the number of prosthetic maintenance visits per participant (NPMV) and cost associated to each visit in Swiss francs (CHF) per participant.

    Measured: from baseline to 12, 24, and 60 months

  10. Incidence of Prosthetic Complications

    Prosthetic complications will be recorded as the number and percentage of participants experiencing at least one clinically relevant complication during follow-up. Complications may include denture base fracture, tooth detachment, prosthesis damage, loss of retention requiring intervention, relining, repair, or prosthesis remake/replacement. Each event will be documented by type and timing.

    Measured: From baseline to 12 months, 24 months, and 60 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 May 2026
  2. Study start1 Sep 2026 (estimated)
  3. Primary completion30 Dec 2031 (estimated)
  4. Study completion30 Dec 2032 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Participants are randomized in a 1:1:1 ratio to one of three parallel groups receiving complete dentures fabricated with different denture tooth materials (3D-printed, CAD/CAM-milled, or prefabricated).
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
45 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07585162
Sponsor's protocol ID
Printow sso grant 370-25
Other IDs
370-25
Acronym
Printow
Status last verified
May 2026
First submitted
30 Apr 2026
Last updated
13 May 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: Individual participant data will not be publicly shared. Data may be available upon reasonable request and subject to applicable ethical and regulatory approvals.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in