Aortic StenosisNCT07605624
Active Post-Market Surveillance of Innovative Devices for Valvular Heart Disease
An observational study of Aortic Stenosis and Aortic Regurgitation, run by Beijing Anzhen Hospital at 1 site in China.
Trial summary
This prospective, multicenter, observational cohort study aims to establish a post-market registry framework to evaluate the real-world clinical applicability, long-term safety, and effectiveness of innovative heart valve devices in China. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Stenosis, Aortic Regurgitation, Mitral Regurgitation
- What is being tested?
- Transcatheter Aortic Valve Replacement, Transcatheter Edge-to-Edge Repair and Transcatheter Tricuspid Valve Annuloplasty
- Type of treatment
- Medical device
- How many people
- 5,500 participants
- Where
- 1 siteChina
- Study dates
- 10 May 2026to 31 Jan 2029
- How long will I take part?
- 1 Year
- Phase
- Observational
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Patients with valvular heart disease who have undergone treatment with innovative heart valve replacement or repair systems, including transcatheter aortic valve replacement (TAVR), transcatheter edge-to-edge repair (TEER), and transcatheter tricuspid valve annuloplasty (TTVA), at 50 medical centers in China.
Who may be able to join
- Patients with valvular heart disease (VHD) receiving treatment with prosthetic aortic valve replacement systems (transcatheter and surgical valves), transcatheter mitral valve edge-to-edge repair (TEER) systems, or transcatheter tricuspid valve annuloplasty systems
- Age ≥ 18 years
- Patients who voluntarily participate in the study and sign the informed consent form
- Willing and able to comply with follow-up requirements
Who cannot join
None listed.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
China1 site
Beijing Anzhen Hospital
Beijing, Beijing Municipality, 100029
Guangyuan Song, MD, PhD, +86 13801120805, songgy_anzhen@vip.163.com
About this study
Official title: An Active Post-Market Surveillance Study Assessing the Real-World Clinical Applicability, Long-Term Safety, and Effectiveness of Innovative Medical Devices for Valvular Heart Disease
This prospective, multicenter, observational cohort study aims to establish a post-market registry framework to evaluate the real-world clinical applicability, long-term safety, and effectiveness of innovative heart valve devices in China.
Read the detailed description
This prospective, multicenter, observational registry study plans to consecutively enroll patients across 50 Chinese hospitals undergoing treatment with innovative heart valve devices-including transcatheter aortic valve replacement (TAVR), surgical aortic valve replacement (SAVR), transcatheter mitral valve edge-to-edge repair (TEER), and transcatheter tricuspid valve annuloplasty (TTVA) systems. By collecting comprehensive data on medical history, physical examinations, laboratory tests, echocardiography, computed tomography (CT), electrocardiogram (ECG), wearable synchronous electrocardiogram-phonocardiogram, procedural details, pharmacotherapy, as well as regular clinical and imaging follow-up, this study aims to establish a post-market registry framework to evaluate the real-world clinical applicability, long-term safety, and effectiveness of innovative heart valve devices.
- Being tested
- Transcatheter Aortic Valve Replacement, Transcatheter Edge-to-Edge Repair, Transcatheter Tricuspid Valve Annuloplasty, Surgical Aortic Valve Replacement
- Medical subject headings
- Aortic Valve Stenosis, Aortic Valve Insufficiency, Mitral Valve Insufficiency, Tricuspid Valve Insufficiency
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Transcatheter Aortic Valve ReplacementDevice
Transcatheter Aortic Valve Replacement
Transcatheter Edge-to-Edge RepairDevice
Transcatheter Edge-to-Edge Repair
Transcatheter Tricuspid Valve AnnuloplastyDevice
Transcatheter Tricuspid Valve Annuloplasty
Surgical Aortic Valve ReplacementDevice
Surgical Aortic Valve Replacement
| Study group | Role | What they receive |
|---|---|---|
| Transcatheter Aortic Valve Replacement | Not described Receives: Device: Transcatheter Aortic Valve Replacement | |
| Transcatheter Edge-to-Edge Repair | Not described Receives: Device: Transcatheter Edge-to-Edge Repair | |
| Transcatheter Tricuspid Valve Annuloplasty | Not described Receives: Device: Transcatheter Tricuspid Valve Annuloplasty | |
| Device: Surgical Aortic Valve Replacement | Not described Receives: Device: Surgical Aortic Valve Replacement |
What is being measured
The primary outcome is the main question the study is designed to answer.
Mortality
Measured: Up to 1 year post-procedure
Rate of neurologic events
Neurologic events are defined according to VARC-3 criteria, including ischaemic stroke, haemorrhagic stroke, and Transient ischaemic attack (TIA):
Ischaemic Stroke: Acute focal neurologic deficit in a vascular territory with symptoms ≥ 24h OR < 24h with neuroimaging (CT or MRI) or pathology confirmation of CNS infarction.
Haemorrhagic Stroke: Acute neurologic deficit due to non-traumatic intracranial hemorrhage, confirmed by neuroimaging (CT or MRI) or pathology.
TIA: Transient focal neurologic deficit < 24h presumed to be ischaemic, but without evidence of acute infarction on neuroimaging (CT or MRI) or pathology.
Measured: Up to 1 year post-procedure
Hospitalization
Measured: Up to 1 year post-procedure
Bleeding and transfusions
Bleeding events are defined according to VARC-3 criteria:
Type 1 (Minor): Overt bleeding that does not require intervention but leads to hospitalization, increased level of care, or medical evaluation, or requires a transfusion of 1 unit of whole blood or red blood cells.
Type 2 (Major): Overt bleeding that requires a transfusion of 2 to 4 units of whole blood or red blood cells, or is associated with a hemoglobin drop of 3 to 5 g/dL.
Type 3 (Life-threatening or Disabling): Overt bleeding in a critical organ (e.g., intracranial, pericardial with tamponade), causing hypovolemic shock or severe hypotension requiring vasopressors or surgery, or requiring a transfusion of ≥ 5 units of whole blood or red blood cells, or associated with a hemoglobin drop ≥ 5 g/dL.
Type 4 (Fatal): Overt bleeding leading to death, classified as probable based on clinical suspicion or definite if confirmed by autopsy or neuroimaging.
Measured: Up to 1 year post-procedure
Vascular and access-related complications
Measured: Periprocedural
Cardiac structural complications
Measured: Periprocedural
Bioprosthetic valve dysfunction
Measured: Up to 1 year post-procedure
Clinically significant valve thrombosis
Measured: Up to 1 year post-procedure
Technical success
Technical success is defined according to VARC-3 criteria, requiring the fulfillment of the following:
- Freedom from mortality.
- Successful access, delivery of the device, and retrieval of the delivery system.
- Correct positioning of a single prosthetic heart valve into the proper anatomical location.
- Freedom from surgery or intervention related to the device, or to a major vascular, access-related, or cardiac structural complication.
Measured: Periprocedural
Device success
Device success is defined according to VARC-3 criteria, requiring the fulfillment of the following:
- Technical success
- Freedom from mortality
- Freedom from surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication
- Intended performance of the valve
Measured: at 30 days
Early safety
Taking the Transcatheter Aortic Valve Replacement cohort as an example, early safety is defined according to VARC-3 criteria, requiring the fulfillment of the following:
- Freedom from all-cause mortality
- Freedom from all stroke
- Freedom from VARC type 2-4 bleeding
- Freedom from major vascular, access-related, or cardiac structural complication
- Freedom from acute kidney injury stage 3 or 4
- Freedom from moderate or severe aortic regurgitation
- Freedom from new permanent pacemaker due to procedure-related conduction abnormalities
- Freedom from surgery or intervention related to the device
Measured: at 30 days
Clinical efficacy
Taking the Transcatheter Aortic Valve Replacement cohort as an example, clinical efficacy is defined according to VARC-3 criteria, requiring the fulfillment of the following:
- Freedom from all-cause mortality
- Freedom from all stroke
- Freedom from hospitalization for procedure- or valve-related causes
- Freedom from KCCQ Overall Summary Score <45 or decline from baseline of >10 point
Measured: Up to 1 year post-procedure
Secondary outcomes (9)
Other procedural or valve-related complications
Measured: Periprocedural
New conduction disturbances and arrhythmias
Measured: Up to 1 year post-procedure
Acute kidney injury
Measured: Periprocedural
Myocardial infarction
Measured: Up to 1 year post-procedure
Leaflet thickening and reduced motion
Measured: Up to 1 year post-procedure
Change in Kansas City Cardiomyopathy Questionnaire (KCCQ) Score
Measured: Up to 1 year post-procedure
New York Heart Association (NYHA) Functional Classification
Class I, II, III, or IV
Measured: Up to 1 year post-procedure
EuroQol 5-Dimension (EQ-5D) Questionnaire Score
Measured: Up to 1 year post-procedure
Change in 6-Minute Walk Distance (6MWD)
Measured: Up to 1 year post-procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 May 2026
- Study start10 May 2026 (estimated)
- Primary completion31 Jan 2029 (estimated)
- Study completion31 Jan 2029 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Aortic StenosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 5,500 participants (estimated)
- Target duration
- 1 Year
Sponsor and investigators
- Lead sponsor
- Beijing Anzhen Hospital
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07605624
- Sponsor's protocol ID
- Beijinganzhen20260406
- Status last verified
- May 2026
- First submitted
- 20 Apr 2026
- Last updated
- 26 May 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No