Endobronchial IntubationNCT07614529
Hyperangulated vs Standard Videolaryngoscopy vs Direct Laryngoscopy for Double-Lumen Endobronchial Tube Intubation
A study testing C-MAC Hyperangulated D-Blade Videolaryngoscopy, C-MAC Macintosh Blade Videolaryngoscopy and Direct Macintosh Laryngoscopy in people with Endobronchial Intubation and Double Lumen Tube Intubation, run by Trakya University at 1 site in Turkey (Türkiye).
Trial summary
This is a prospective, randomized, single-center, three-arm, open-label, low-risk medical device clinical study conducted at the Department of Anesthesiology and Reanimation, Trakya University Medical Faculty. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Endobronchial Intubation, Double Lumen Tube Intubation, Thoracic Surgery
- What is being tested?
- C-MAC Hyperangulated D-Blade Videolaryngoscopy, C-MAC Macintosh Blade Videolaryngoscopy and Direct Macintosh Laryngoscopy
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 180 participants
- Where
- 1 siteTurkey (Türkiye)
- Study dates
- 15 Jun 2026to 15 Jan 2029
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Age 18 years or older
- Written informed consent obtained prior to surgery
- ASA physical status class I, II, or III
- Scheduled for elective thoracic surgery requiring one-lung ventilation and double-lumen endobronchial intubation
Who cannot join
- Age under 18 years
- Refusal or inability to provide informed consent
- ASA physical status class IV or above
- Emergency surgery
- Anticipated difficult airway, defined by any of the following: Mallampati score 4, thyromental distance less than 6.5 cm, restricted mouth opening, or BMI greater than 30 kg/m²
- History of upper airway surgery
- Significant upper airway obstruction or stridor
- Pregnancy
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Turkey (Türkiye)1 site, 1 recruiting
- Recruiting
Trakya University Hospital
Edirne, Edirne, 22030
Havva Suheyla AKIN UZAN, +905079516118, shylaakin@gmail.com
About this study
Official title: Evaluation of Efficacy and Safety of Hyperangulated and Standard Curvature Blade Video Laryngoscopy Versus Direct Laryngoscopy for Double-Lumen Endobronchial Tube Intubation
This is a prospective, randomized, single-center, three-arm, open-label, low-risk medical device clinical study conducted at the Department of Anesthesiology and Reanimation, Trakya University Medical Faculty.
The study aims to compare the efficacy, safety, and clinical usability of three laryngoscopy methods for double-lumen endotracheal tube (DLT) intubation in patients undergoing elective thoracic surgery requiring one-lung ventilation: (i) C-MAC hyperangulated (D-blade) videolaryngoscopy, (ii) C-MAC Macintosh blade videolaryngoscopy, and (iii) direct Macintosh laryngoscopy.
Read more
The primary outcome is the total time to successful DLT placement (in seconds), defined as the interval from the end of mask ventilation to fiberoptic bronchoscopic confirmation of correct tube position. Secondary outcomes include glottic visualization quality (POGO score and Cormack-Lehane grade), intubation difficulty (Intubation Difficulty Scale), number of intubation attempts, need for auxiliary maneuvers, intubation-related complications, malposition rate, and postoperative airway symptoms (sore throat, dysphonia) assessed at 1, 6, and 24 hours postoperatively.
Eligible patients are adults (≥18 years), ASA class I-III, scheduled for elective thoracic surgery requiring one-lung ventilation. Patients with anticipated difficult airway, emergency surgery, pregnancy, or prior upper airway surgery are excluded. A total of 180 patients will be enrolled and randomized 1:1:1 into three groups (60 per group) using computer-generated block randomization.
Read the detailed description
Background and Rationale:
Double-lumen endobronchial tubes (DLTs) are the primary airway device for one-lung ventilation (OLV) in intrathoracic surgery. Their use enables lung isolation, which is essential for surgical exposure in procedures such as lobectomy, pneumonectomy, esophagectomy, and thoracoscopic interventions. Despite their widespread use, DLT placement is technically more demanding than standard single-lumen endotracheal intubation due to the tube's larger outer diameter, greater length, increased rigidity, and the presence of a distal bronchial cuff. These structural characteristics make laryngoscopy and tube advancement through the glottis considerably more challenging and are associated with a higher incidence of oropharyngeal, laryngeal, and tracheobronchial trauma compared to standard intubation.
Airway injuries related to DLT placement span a wide spectrum, ranging from minor mucosal lacerations of the lips, tongue, and pharynx to temporary or permanent vocal cord damage. In rare but serious cases, tracheobronchial perforation has been reported, a potentially life-threatening complication. The increased structural difficulty of DLT intubation translates into a higher likelihood of multiple intubation attempts, each of which independently increases the risk of airway trauma, hemodynamic instability due to prolonged laryngoscopy, and desaturation. Minimizing the number of attempts and the total intubation time is therefore of direct clinical importance in this patient population.
Videolaryngoscopy (VL) has become increasingly integrated into routine and difficult airway management over the past two decades. By providing an indirect, magnified view of the glottis transmitted via a camera mounted at the tip of the blade, VL improves glottic visualization compared to direct laryngoscopy (DL), particularly in patients with anticipated or unanticipated difficult airways. Multiple meta-analyses and randomized controlled trials have demonstrated the superiority of VL over DL in terms of first-attempt success rate, Cormack-Lehane grade, and rate of esophageal intubation in both routine and difficult airway scenarios.
The Storz C-MAC system is one of the most widely studied videolaryngoscopes and is available in two blade configurations relevant to this study: the Macintosh-geometry blade (C-MAC M-blade), which allows both direct and indirect laryngoscopy and preserves familiar hand mechanics, and the hyperangulated D-blade (C-MAC D-blade), which provides a more acute viewing angle and is specifically designed for cases where standard geometry blades fail to achieve adequate glottic exposure. Both blades transmit a high-resolution image to an external monitor, and the C-MAC system has been shown to improve first-attempt success rates and glottic visualization in a range of clinical settings.
In the context of DLT intubation, the choice of laryngoscope blade is further complicated by the need to shape the DLT stylet to match the blade curvature. A hyperangulated blade requires a correspondingly acute stylet bend, which may facilitate or hinder tube advancement depending on the operator's experience and the patient's anatomy. While several studies have compared videolaryngoscopy systems with direct laryngoscopy for DLT placement - including the GlideScope, C-MAC, and other platforms - the existing literature remains limited in volume and inconsistent in its conclusions. No adequately powered prospective randomized trial has directly compared the C-MAC D-blade, C-MAC M-blade, and standard direct Macintosh laryngoscopy head-to-head for DLT intubation in thoracic surgery patients. The present study is designed to address this gap.
Objectives and Hypotheses:
The primary objective of this study is to compare three laryngoscopy techniques for DLT intubation - (i) C-MAC hyperangulated D-blade videolaryngoscopy (HCMAC), (ii) C-MAC Macintosh blade videolaryngoscopy (MCMAC), and (iii) direct Macintosh laryngoscopy (DL) - with respect to intubation time, glottic visualization quality, procedural difficulty, and intubation-related complications in adult patients undergoing elective thoracic surgery requiring one-lung ventilation.
The secondary objective is to provide prospective, randomized clinical evidence to guide the selection of the most appropriate laryngoscopy method for DLT intubation in routine thoracic anesthesia practice and to contribute to standardization of airway management in this surgical context.
Primary hypothesis: Total DLT placement time is shorter with videolaryngoscopy, particularly with the C-MAC hyperangulated D-blade, compared to direct Macintosh laryngoscopy.
Secondary hypotheses: (1) Videolaryngoscopy groups will demonstrate superior glottic visualization as measured by POGO score and Cormack-Lehane grade. (2) Intubation difficulty as assessed by the Intubation Difficulty Scale (IDS) and the need for auxiliary maneuvers will be lower in videolaryngoscopy groups. (3) The overall incidence of intubation-related complications, including mucosal trauma, dental or lip injury, and hemodynamic perturbations associated with laryngoscopy, will be lower in videolaryngoscopy groups compared to direct laryngoscopy.
Study Design:
This is a prospective, randomized, single-center, three-arm, open-label, low-risk medical device clinical study. The study is conducted at the Department of Anesthesiology and Reanimation, Trakya University Medical Faculty, Trakya University Health Research and Application Center Hospital, Edirne, Turkey. The study is classified as a low-risk medical device clinical investigation, as all procedures are performed within the scope of routine clinical care and no additional investigational drugs or invasive interventions beyond standard practice are introduced.
Patients fulfilling eligibility criteria are randomized in a 1:1:1 ratio to one of three study arms (HCMAC, MCMAC, or DL) using a computer-generated block randomization sequence. Allocation concealment is maintained using sequentially numbered, opaque, sealed envelopes that are opened in the operating room immediately prior to the intubation attempt.
Eligibility Criteria:
Inclusion criteria: age ≥18 years; written informed consent obtained prior to surgery; ASA physical status class I, II, or III; scheduled for elective thoracic surgery requiring one-lung ventilation and double-lumen endobronchial intubation.
Exclusion criteria: age <18 years; refusal or inability to provide informed consent; ASA physical status class IV or above; emergency surgery; anticipated difficult airway defined by any of the following - Mallampati score 4, thyromental distance <6.5 cm, restricted mouth opening, or BMI >30 kg/m²; history of upper airway surgery; significant upper airway obstruction or stridor; pregnancy.
Interventions and Procedures:
All patients receive standard intraoperative monitoring per ASA guidelines, including continuous ECG, peripheral oxygen saturation (SpO₂), and non-invasive blood pressure (NIBP). Following induction of general anesthesia, mask ventilation is performed until conditions for intubation are achieved. DLT size is selected according to a validated sex- and height-based sizing scale. The intubation is then performed using the laryngoscopy device assigned by randomization.
Glottic visualization is assessed by the operator immediately upon laryngoscope insertion and recorded as Cormack-Lehane grade and POGO score. Intubation time is defined as the interval from cessation of mask ventilation to fiberoptic bronchoscopic confirmation of correct DLT positioning, and is recorded in seconds. The number of intubation attempts and any auxiliary maneuvers employed - including BURP (backward-upward-rightward pressure), Sellick maneuver, shoulder elevation, 90° or 270° tube rotation during bronchial advancement, and external tracheal pressure - are documented. Where applicable, the number of tube size changes, the sizes attempted, and the size ultimately used for successful placement are recorded.
Correct DLT placement is defined as positioning of the tube in the target bronchus without proximal or distal migration, confirmed by fiberoptic bronchoscopy. Malposition is classified as: deep bronchial migration, contralateral bronchial placement, or proximal (tracheal) positioning, and is corrected under fiberoptic guidance. If three intubation attempts fail, the institution's established difficult airway management algorithm is activated and the case is classified as intubation failure. All devices used in this study are CE-marked and are used strictly in accordance with their intended purpose as specified by the manufacturer.
Hemodynamic parameters (SpO₂, heart rate, NIBP) are recorded at baseline, immediately before intubation, and at 0, 1, 3, 5, and 10 minutes after intubation. Where available, subglottic diameter and left main bronchial diameter are measured from preoperative CT imaging and recorded. Postoperative assessment includes evaluation for sore throat, dysphagia, and dysphonia at 1, 6, and 24 hours after surgery, as well as documentation of any signs of airway trauma observed intraoperatively or in the postoperative care unit.
Sample Size and Statistical Analysis:
Sample size was estimated based on a power analysis using data from previous reference studies (linked at "references" section). Cohen's effect size f was calculated as 0.235. With 80% statistical power and a two-sided type I error rate of 5%, a minimum of 60 patients per group is required, yielding a total enrollment target of 180 patients across three groups.
Normality of continuous variables will be assessed using the Shapiro-Wilk test. For normally distributed variables, between-group comparisons will be performed using one-way analysis of variance (ANOVA); for non-normally distributed variables, the Kruskal-Wallis test will be used. Relationships between categorical variables will be analyzed using chi-square tests. Correlations between continuous variables will be assessed using Pearson or Spearman correlation analysis as appropriate. Continuous variables will be reported as mean ± standard deviation or median (interquartile range) according to distribution; categorical variables will be reported as frequency and percentage. The threshold for statistical significance is set at p < 0.05 for all analyses.
- Conditions
- Endobronchial Intubation, Double Lumen Tube Intubation, Thoracic Surgery, One Lung Ventillation (OLV)
- Being tested
- C-MAC Hyperangulated D-Blade Videolaryngoscopy, C-MAC Macintosh Blade Videolaryngoscopy, Direct Macintosh Laryngoscopy
- Keywords
- double-lumen endotracheal tube, videolaryngoscopy, direct laryngoscopy, C-MAC, thoracic anesthesia, one-lung ventilation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
C-MAC Hyperangulated D-Blade VideolaryngoscopyDevice
Double-lumen endotracheal tube intubation performed using the Storz C-MAC hyperangulated D-blade videolaryngoscope. The D-blade provides an acutely angled viewing geometry with high-resolution video transmission to an external monitor. The DLT stylet is shaped to match the D-blade curvature prior to intubation. All devices are CE-marked and used in accordance with the manufacturer's intended purpose.
C-MAC Macintosh Blade VideolaryngoscopyDevice
Double-lumen endotracheal tube intubation performed using the Storz C-MAC Macintosh blade videolaryngoscope. The Macintosh geometry blade enables both direct and video-assisted laryngoscopy while preserving standard hand mechanics. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. All devices are CE-marked and used in accordance with the manufacturer's intended purpose.
Direct Macintosh LaryngoscopyDevice
Double-lumen endotracheal tube intubation performed using a standard direct Macintosh laryngoscope without video assistance. This represents current standard clinical practice for DLT intubation in thoracic surgery and serves as the active comparator. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. All devices are CE-marked and used in accordance with the manufacturer's intended purpose.
| Study group | Role | What they receive |
|---|---|---|
| Hyper-angulated blade C-MAC videolaryngoscopy | Experimental | HCMAC:
DLT intubation performed using the Storz C-MAC hyperangulated D-blade videolaryngoscope. The D-blade provides an acutely angled geometry and transmits a high-resolution glottic image to an external monitor. The DLT stylet is shaped to match the hyperangulated blade curvature prior to intubation. Glottic view, intubation time, number of attempts, auxiliary maneuvers, and intubation-related complications are recorded. Correct tube placement is confirmed by fiberoptic bronchoscopy. Receives: Device: C-MAC Hyperangulated D-Blade Videolaryngoscopy |
| Macintosh-type blade C-MAC videolaryngoscopy | Experimental | MCMAC:
DLT intubation performed using the Storz C-MAC Macintosh blade videolaryngoscope. The Macintosh geometry blade allows both direct and indirect (video-assisted) laryngoscopy and preserves standard hand mechanics familiar to the operator. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. Glottic view, intubation time, number of attempts, auxiliary maneuvers, and intubation-related complications are recorded. Correct tube placement is confirmed by fiberoptic bronchoscopy. Receives: Device: C-MAC Macintosh Blade Videolaryngoscopy |
| Direct laryngoscopy | Active comparator | DL:
DLT intubation performed using a standard direct Macintosh laryngoscope without video assistance. This arm serves as the active comparator representing current standard clinical practice for DLT intubation in thoracic surgery. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. Glottic view, intubation time, number of attempts, auxiliary maneuvers, and intubation-related complications are recorded. Correct tube placement is confirmed by fiberoptic bronchoscopy. Receives: Device: Direct Macintosh Laryngoscopy |
What is being measured
The primary outcome is the main question the study is designed to answer.
Total time to successful double-lumen endotracheal tube placement-seconds
Total intubation time in seconds, defined as the interval from cessation of mask ventilation to the appearance of the first complete end-tidal CO2 waveform confirming successful endotracheal tube placement. Final tube position is verified by fiberoptic bronchoscopy. If the tube is not placed properly, fiberoptic bronchoscopy is used to correct the position. Time is recorded continuously for each participant using a stopwatch. In cases requiring multiple intubation attempts, cumulative time across all attempts is recorded. Cases requiring activation of the difficult airway algorithm after three failed attempts are classified as intubation failure and analyzed separately.
Measured: Intraoperative (from cessation of mask ventilation to appearance of the first complete end-tidal CO2 waveform confirming successful DLT placement, assessed immediately after intubation)
Secondary outcomes (10)
Glottic visualization quality - POGO score
Percentage of Glottic Opening (POGO) score assessed by the operator immediately upon laryngoscope insertion, expressed as a percentage from 0% (no glottic structures visible) to 100% (entire glottic opening visible).
Measured: Intraoperative (assessed immediately upon laryngoscope insertion)
Glottic visualization quality - Cormack-Lehane grade
Cormack-Lehane laryngoscopic grade (I, II, III, IV) assessed by the operator immediately upon laryngoscope insertion and recorded as an ordinal variable.
Measured: Intraoperative (assessed immediately upon laryngoscope insertion)
Intubation difficulty - Intubation Difficulty Scale (IDS)
Intubation Difficulty Scale (IDS) score calculated after each intubation, incorporating number of attempts, number of operators, number of techniques used, Cormack-Lehane grade, lifting force, laryngeal pressure, and vocal cord position. Higher scores indicate greater intubation difficulty.
Measured: Intraoperative (assessed immediately after intubation)
Number of intubation attempts
Total number of intubation attempts required for successful DLT placement, defined as each insertion of the tube past the teeth. Cases requiring more than three attempts are classified as intubation failure and managed according to the institutional difficult airway algorithm.
Measured: Intraoperative (recorded during the intubation procedure)
Rate of need for auxiliary maneuvers
Incidence, type and number of auxiliary maneuvers required during DLT intubation, including BURP (backward-upward-rightward pressure), Sellick maneuver, shoulder elevation, 90° or 270° tube rotation during bronchial advancement, and external tracheal pressure.
Measured: Intraoperative (recorded during the intubation procedure)
Rate of intubation-related complications
Incidence of intraoperative intubation-related complications including mucosal bleeding, dental, lip or tongue trauma, and oxygen desaturation (SpO2 <92%) during laryngoscopy. Assessed by direct visualization intraoperatively and in the post-anesthesia care unit.
Measured: Intraoperative and immediately postoperative (up to 1 hour after surgery)
Rate of DLT malposition confirmed by fiberoptic bronchoscopy
Incidence and classification of DLT malposition confirmed by fiberoptic bronchoscopy, categorized as deep bronchial migration, contralateral bronchial placement, or proximal (tracheal) positioning. All malpositions are corrected under fiberoptic guidance.
Measured: Intraoperative (assessed immediately after intubation by fiberoptic bronchoscopy)
Postoperative sore throat assessed by a Numerical Analog Scale
Severity of postoperative sore throat assessed using a Numerical Analog Scale (NAS) at 1, 6, and 24 hours after surgery.
Measured: Postoperative 1, 6, and 24 hours
Postoperative dysphonia and cough assessed by a 4-point scale (0-3=
Presence and severity of voice change (dysphonia) and cough assessed at 1, 6, and 24 hours after surgery 0=none, 1=mild, 2=moderate, 3=severe
Measured: Postoperative 1, 6, and 24 hours
Rate of dental and oral mucosal injury detected post-operatively
Presence of dental injury and oral mucosal injury assessed at 1, 6, and 24 hours after surgery, recorded as present or absent by direct clinical evaluation.
Measured: Postoperative 1, 6, and 24 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted29 May 2026
- Study start15 Jun 2026
- Primary completion15 Nov 2028 (estimated)
- Study completion15 Jan 2029 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Endobronchial IntubationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 180 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Trakya University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Havva Suheyla AKIN UZAN, MD, Trakya University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07614529
- Sponsor's protocol ID
- 2607A07
- Other IDs
- DLT-VL 2026
- Status last verified
- Jun 2026
- First submitted
- 11 May 2026
- Last updated
- 30 Oct 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 30 Oct 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Efficacy and Safety of Hyperangulated and Standard Curvature Blade Video Laryngoscopy Versus Direct Laryngoscopy for Double-Lumen Endobronchial Tube Intubation
- ClinicalTrials.gov ID
- NCT07614529
- Acronym / sponsor ID
- 2607A07
- Conditions
- Endobronchial Intubation, Double Lumen Tube Intubation, Thoracic Surgery, One Lung Ventillation (OLV)
- Keywords
- double-lumen endotracheal tube, videolaryngoscopy, direct laryngoscopy, C-MAC, thoracic anesthesia, one-lung ventilation
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 180 participants (estimated)
- Lead sponsor
- Trakya UniversityUniversity, hospital or other
- Study start
- 15 Jun 2026 (actual)
- Primary completion
- 15 Nov 2028 (estimated)
- Study completion
- 15 Jan 2029 (estimated)
- First posted
- 29 May 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a prospective, randomized, single-center, three-arm, open-label, low-risk medical device clinical study conducted at the Department of Anesthesiology and Reanimation, Trakya University Medical Faculty.
The study aims to compare the efficacy, safety, and clinical usability of three laryngoscopy methods for double-lumen endotracheal tube (DLT) intubation in patients undergoing elective thoracic surgery requiring one-lung ventilation: (i) C-MAC hyperangulated (D-blade) videolaryngoscopy, (ii) C-MAC Macintosh blade videolaryngoscopy, and (iii) direct Macintosh laryngoscopy.
The primary outcome is the total time to successful DLT placement (in seconds), defined as the interval from the end of mask ventilation to fiberoptic bronchoscopic confirmation of correct tube position. Secondary outcomes include glottic visualization quality (POGO score and Cormack-Lehane grade), intubation difficulty (Intubation Difficulty Scale), number of intubation attempts, need for auxiliary maneuvers, intubation-related complications, malposition rate, and postoperative airway symptoms (sore throat, dysphonia) assessed at 1, 6, and 24 hours postoperatively.
Eligible patients are adults (≥18 years), ASA class I-III, scheduled for elective thoracic surgery requiring one-lung ventilation. Patients with anticipated difficult airway, emergency surgery, pregnancy, or prior upper airway surgery are excluded. A total of 180 patients will be enrolled and randomized 1:1:1 into three groups (60 per group) using computer-generated block randomization.
Detailed description
Background and Rationale:
Double-lumen endobronchial tubes (DLTs) are the primary airway device for one-lung ventilation (OLV) in intrathoracic surgery. Their use enables lung isolation, which is essential for surgical exposure in procedures such as lobectomy, pneumonectomy, esophagectomy, and thoracoscopic interventions. Despite their widespread use, DLT placement is technically more demanding than standard single-lumen endotracheal intubation due to the tube's larger outer diameter, greater length, increased rigidity, and the presence of a distal bronchial cuff. These structural characteristics make laryngoscopy and tube advancement through the glottis considerably more challenging and are associated with a higher incidence of oropharyngeal, laryngeal, and tracheobronchial trauma compared to standard intubation.
Airway injuries related to DLT placement span a wide spectrum, ranging from minor mucosal lacerations of the lips, tongue, and pharynx to temporary or permanent vocal cord damage. In rare but serious cases, tracheobronchial perforation has been reported, a potentially life-threatening complication. The increased structural difficulty of DLT intubation translates into a higher likelihood of multiple intubation attempts, each of which independently increases the risk of airway trauma, hemodynamic instability due to prolonged laryngoscopy, and desaturation. Minimizing the number of attempts and the total intubation time is therefore of direct clinical importance in this patient population.
Videolaryngoscopy (VL) has become increasingly integrated into routine and difficult airway management over the past two decades. By providing an indirect, magnified view of the glottis transmitted via a camera mounted at the tip of the blade, VL improves glottic visualization compared to direct laryngoscopy (DL), particularly in patients with anticipated or unanticipated difficult airways. Multiple meta-analyses and randomized controlled trials have demonstrated the superiority of VL over DL in terms of first-attempt success rate, Cormack-Lehane grade, and rate of esophageal intubation in both routine and difficult airway scenarios.
The Storz C-MAC system is one of the most widely studied videolaryngoscopes and is available in two blade configurations relevant to this study: the Macintosh-geometry blade (C-MAC M-blade), which allows both direct and indirect laryngoscopy and preserves familiar hand mechanics, and the hyperangulated D-blade (C-MAC D-blade), which provides a more acute viewing angle and is specifically designed for cases where standard geometry blades fail to achieve adequate glottic exposure. Both blades transmit a high-resolution image to an external monitor, and the C-MAC system has been shown to improve first-attempt success rates and glottic visualization in a range of clinical settings.
In the context of DLT intubation, the choice of laryngoscope blade is further complicated by the need to shape the DLT stylet to match the blade curvature. A hyperangulated blade requires a correspondingly acute stylet bend, which may facilitate or hinder tube advancement depending on the operator's experience and the patient's anatomy. While several studies have compared videolaryngoscopy systems with direct laryngoscopy for DLT placement - including the GlideScope, C-MAC, and other platforms - the existing literature remains limited in volume and inconsistent in its conclusions. No adequately powered prospective randomized trial has directly compared the C-MAC D-blade, C-MAC M-blade, and standard direct Macintosh laryngoscopy head-to-head for DLT intubation in thoracic surgery patients. The present study is designed to address this gap.
Objectives and Hypotheses:
The primary objective of this study is to compare three laryngoscopy techniques for DLT intubation - (i) C-MAC hyperangulated D-blade videolaryngoscopy (HCMAC), (ii) C-MAC Macintosh blade videolaryngoscopy (MCMAC), and (iii) direct Macintosh laryngoscopy (DL) - with respect to intubation time, glottic visualization quality, procedural difficulty, and intubation-related complications in adult patients undergoing elective thoracic surgery requiring one-lung ventilation.
The secondary objective is to provide prospective, randomized clinical evidence to guide the selection of the most appropriate laryngoscopy method for DLT intubation in routine thoracic anesthesia practice and to contribute to standardization of airway management in this surgical context.
Primary hypothesis: Total DLT placement time is shorter with videolaryngoscopy, particularly with the C-MAC hyperangulated D-blade, compared to direct Macintosh laryngoscopy.
Secondary hypotheses: (1) Videolaryngoscopy groups will demonstrate superior glottic visualization as measured by POGO score and Cormack-Lehane grade. (2) Intubation difficulty as assessed by the Intubation Difficulty Scale (IDS) and the need for auxiliary maneuvers will be lower in videolaryngoscopy groups. (3) The overall incidence of intubation-related complications, including mucosal trauma, dental or lip injury, and hemodynamic perturbations associated with laryngoscopy, will be lower in videolaryngoscopy groups compared to direct laryngoscopy.
Study Design:
This is a prospective, randomized, single-center, three-arm, open-label, low-risk medical device clinical study. The study is conducted at the Department of Anesthesiology and Reanimation, Trakya University Medical Faculty, Trakya University Health Research and Application Center Hospital, Edirne, Turkey. The study is classified as a low-risk medical device clinical investigation, as all procedures are performed within the scope of routine clinical care and no additional investigational drugs or invasive interventions beyond standard practice are introduced.
Patients fulfilling eligibility criteria are randomized in a 1:1:1 ratio to one of three study arms (HCMAC, MCMAC, or DL) using a computer-generated block randomization sequence. Allocation concealment is maintained using sequentially numbered, opaque, sealed envelopes that are opened in the operating room immediately prior to the intubation attempt.
Eligibility Criteria:
Inclusion criteria: age ≥18 years; written informed consent obtained prior to surgery; ASA physical status class I, II, or III; scheduled for elective thoracic surgery requiring one-lung ventilation and double-lumen endobronchial intubation.
Exclusion criteria: age <18 years; refusal or inability to provide informed consent; ASA physical status class IV or above; emergency surgery; anticipated difficult airway defined by any of the following - Mallampati score 4, thyromental distance <6.5 cm, restricted mouth opening, or BMI >30 kg/m²; history of upper airway surgery; significant upper airway obstruction or stridor; pregnancy.
Interventions and Procedures:
All patients receive standard intraoperative monitoring per ASA guidelines, including continuous ECG, peripheral oxygen saturation (SpO₂), and non-invasive blood pressure (NIBP). Following induction of general anesthesia, mask ventilation is performed until conditions for intubation are achieved. DLT size is selected according to a validated sex- and height-based sizing scale. The intubation is then performed using the laryngoscopy device assigned by randomization.
Glottic visualization is assessed by the operator immediately upon laryngoscope insertion and recorded as Cormack-Lehane grade and POGO score. Intubation time is defined as the interval from cessation of mask ventilation to fiberoptic bronchoscopic confirmation of correct DLT positioning, and is recorded in seconds. The number of intubation attempts and any auxiliary maneuvers employed - including BURP (backward-upward-rightward pressure), Sellick maneuver, shoulder elevation, 90° or 270° tube rotation during bronchial advancement, and external tracheal pressure - are documented. Where applicable, the number of tube size changes, the sizes attempted, and the size ultimately used for successful placement are recorded.
Correct DLT placement is defined as positioning of the tube in the target bronchus without proximal or distal migration, confirmed by fiberoptic bronchoscopy. Malposition is classified as: deep bronchial migration, contralateral bronchial placement, or proximal (tracheal) positioning, and is corrected under fiberoptic guidance. If three intubation attempts fail, the institution's established difficult airway management algorithm is activated and the case is classified as intubation failure. All devices used in this study are CE-marked and are used strictly in accordance with their intended purpose as specified by the manufacturer.
Hemodynamic parameters (SpO₂, heart rate, NIBP) are recorded at baseline, immediately before intubation, and at 0, 1, 3, 5, and 10 minutes after intubation. Where available, subglottic diameter and left main bronchial diameter are measured from preoperative CT imaging and recorded. Postoperative assessment includes evaluation for sore throat, dysphagia, and dysphonia at 1, 6, and 24 hours after surgery, as well as documentation of any signs of airway trauma observed intraoperatively or in the postoperative care unit.
Sample Size and Statistical Analysis:
Sample size was estimated based on a power analysis using data from previous reference studies (linked at "references" section). Cohen's effect size f was calculated as 0.235. With 80% statistical power and a two-sided type I error rate of 5%, a minimum of 60 patients per group is required, yielding a total enrollment target of 180 patients across three groups.
Normality of continuous variables will be assessed using the Shapiro-Wilk test. For normally distributed variables, between-group comparisons will be performed using one-way analysis of variance (ANOVA); for non-normally distributed variables, the Kruskal-Wallis test will be used. Relationships between categorical variables will be analyzed using chi-square tests. Correlations between continuous variables will be assessed using Pearson or Spearman correlation analysis as appropriate. Continuous variables will be reported as mean ± standard deviation or median (interquartile range) according to distribution; categorical variables will be reported as frequency and percentage. The threshold for statistical significance is set at p < 0.05 for all analyses.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Hyper-angulated blade C-MAC videolaryngoscopy | Experimental | Device: C-MAC Hyperangulated D-Blade VideolaryngoscopyHCMAC: DLT intubation performed using the Storz C-MAC hyperangulated D-blade videolaryngoscope. The D-blade provides an acutely angled geometry and transmits a high-resolution glottic image to an external monitor. The DLT stylet is shaped to match the hyperangulated blade curvature prior to intubation. Glottic view, intubation time, number of attempts, auxiliary maneuvers, and intubation-related complications are recorded. Correct tube placement is confirmed by fiberoptic bronchoscopy. |
| Macintosh-type blade C-MAC videolaryngoscopy | Experimental | Device: C-MAC Macintosh Blade VideolaryngoscopyMCMAC: DLT intubation performed using the Storz C-MAC Macintosh blade videolaryngoscope. The Macintosh geometry blade allows both direct and indirect (video-assisted) laryngoscopy and preserves standard hand mechanics familiar to the operator. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. Glottic view, intubation time, number of attempts, auxiliary maneuvers, and intubation-related complications are recorded. Correct tube placement is confirmed by fiberoptic bronchoscopy. |
| Direct laryngoscopy | Active comparator | Device: Direct Macintosh LaryngoscopyDL: DLT intubation performed using a standard direct Macintosh laryngoscope without video assistance. This arm serves as the active comparator representing current standard clinical practice for DLT intubation in thoracic surgery. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. Glottic view, intubation time, number of attempts, auxiliary maneuvers, and intubation-related complications are recorded. Correct tube placement is confirmed by fiberoptic bronchoscopy. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Age 18 years or older
- Written informed consent obtained prior to surgery
- ASA physical status class I, II, or III
- Scheduled for elective thoracic surgery requiring one-lung ventilation and double-lumen endobronchial intubation
Key exclusion criteria (8 listed)
- Age under 18 years
- Refusal or inability to provide informed consent
- ASA physical status class IV or above
- Emergency surgery
- Anticipated difficult airway, defined by any of the following: Mallampati score 4, thyromental distance less than 6.5 cm, restricted mouth opening, or BMI greater than 30 kg/m²
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| C-MAC Hyperangulated D-Blade VideolaryngoscopyDouble-lumen endotracheal tube intubation performed using the Storz C-MAC hyperangulated D-blade videolaryngoscope. The D-blade provides an acutely angled viewing geometry with high-resolution video transmission to an external monitor. The DLT stylet is shaped to match the D-blade curvature prior to intubation. All devices are CE-marked and used in accordance with the manufacturer's intended purpose. | Device | Hyper-angulated blade C-MAC videolaryngoscopy |
| C-MAC Macintosh Blade VideolaryngoscopyDouble-lumen endotracheal tube intubation performed using the Storz C-MAC Macintosh blade videolaryngoscope. The Macintosh geometry blade enables both direct and video-assisted laryngoscopy while preserving standard hand mechanics. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. All devices are CE-marked and used in accordance with the manufacturer's intended purpose. | Device | Macintosh-type blade C-MAC videolaryngoscopy |
| Direct Macintosh LaryngoscopyDouble-lumen endotracheal tube intubation performed using a standard direct Macintosh laryngoscope without video assistance. This represents current standard clinical practice for DLT intubation in thoracic surgery and serves as the active comparator. The DLT stylet is shaped to match the Macintosh blade curvature prior to intubation. All devices are CE-marked and used in accordance with the manufacturer's intended purpose. | Device | Direct laryngoscopy |
Primary outcome
Total time to successful double-lumen endotracheal tube placement-seconds
Time frame: Intraoperative (from cessation of mask ventilation to appearance of the first complete end-tidal CO2 waveform confirming successful DLT placement, assessed immediately after intubation)
Total intubation time in seconds, defined as the interval from cessation of mask ventilation to the appearance of the first complete end-tidal CO2 waveform confirming successful endotracheal tube placement. Final tube position is verified by fiberoptic bronchoscopy. If the tube is not placed properly, fiberoptic bronchoscopy is used to correct the position. Time is recorded continuously for each participant using a stopwatch. In cases requiring multiple intubation attempts, cumulative time across all attempts is recorded. Cases requiring activation of the difficult airway algorithm after three failed attempts are classified as intubation failure and analyzed separately.
10 secondary outcomes
Glottic visualization quality - POGO score
Time frame: Intraoperative (assessed immediately upon laryngoscope insertion)
Glottic visualization quality - Cormack-Lehane grade
Time frame: Intraoperative (assessed immediately upon laryngoscope insertion)
Intubation difficulty - Intubation Difficulty Scale (IDS)
Time frame: Intraoperative (assessed immediately after intubation)
Number of intubation attempts
Time frame: Intraoperative (recorded during the intubation procedure)
Rate of need for auxiliary maneuvers
Time frame: Intraoperative (recorded during the intubation procedure)
Rate of intubation-related complications
Time frame: Intraoperative and immediately postoperative (up to 1 hour after surgery)
Rate of DLT malposition confirmed by fiberoptic bronchoscopy
Time frame: Intraoperative (assessed immediately after intubation by fiberoptic bronchoscopy)
Postoperative sore throat assessed by a Numerical Analog Scale
Time frame: Postoperative 1, 6, and 24 hours
Postoperative dysphonia and cough assessed by a 4-point scale (0-3=
Time frame: Postoperative 1, 6, and 24 hours
Rate of dental and oral mucosal injury detected post-operatively
Time frame: Postoperative 1, 6, and 24 hours
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Oct 2026.
- Related InfoLink provided by the sponsor.
- Related InfoLink provided by the sponsor.
- Individual participant dataSharing planned: Undecided
Related trials for Endobronchial Intubation
Recruiting
A Randomized Controlled Trial of 3D Airway Reconstruction for Precise Double-Lumen Bronchial Intubation
Pulmonary Nodules
Not yet recruitingObservational study
A Prospective Clinical Study Observed the Effects of Tubeless Anesthesia Method That Preserves Spontaneous Breathing and the Double-lumen Bronchial Intubation on the Brain Health During the Perioperative Period
Brain Health
Active, not recruiting
Efficacy of Flurbiprofen Spray for Postoperative Sore Throat Following Double-Lumen Endobronchial Intubation
Post Operative Sore Throat, Hoarseness
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing C-MAC Hyperangulated D-Blade Videolaryngoscopy, C-MAC Macintosh Blade Videolaryngoscopy and Direct Macintosh Laryngoscopy in people with Endobronchial Intubation and Double Lumen Tube Intubation, run by Trakya University at 1 site in Turkey (Türkiye).
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 30 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact havva suheyla akin uzan, medical doctor (+905079516118, shylaakin@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Total time to successful double-lumen endotracheal tube placement-seconds (time frame: Intraoperative (from cessation of mask ventilation to appearance of the first complete end-tidal CO2 waveform confirming successful DLT placement, assessed immediately after intubation)). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Oct 2026.