Impact of Atrioventricular Delay Optimization on Ventricular Function in Conduction System Pacing

A study testing Echocardiography-Guided Atrioventricular Delay Optimization in people with Atrioventricular Block and Conduction System Pacing, run by Bursa Yuksek Ihtisas Training and Research Hospital at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Conduction system pacing has emerged as a physiological pacing strategy that preserves ventricular electrical activation and minimizes pacing-induced dyssynchrony. However, the optimal atrioventricular delay setting in patients undergoing conduction system pacing remains uncertain. Read more about this study

Who is it for?
Ages 18 to 80 years
What is being tested?
Echocardiography-Guided Atrioventricular Delay Optimization
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
39 participants
Where
1 siteTurkey (Türkiye)
Study dates
6 Oct 2025to 17 Feb 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age between 18 and 80 years
  • Permanent conduction system pacing implantation for atrioventricular block
  • At least 1 month elapsed since device implantation
  • Sinus rhythm at the time of enrollment
  • Left ventricular ejection fraction >40%
  • Adequate echocardiographic image quality for comprehensive assessment
  • Ability and willingness to provide informed consent

Who cannot join

  • Permanent or persistent atrial fibrillation
  • Significant valvular heart disease
  • Active malignancy
  • Severe systemic illness with limited life expectancy
  • Sinus node dysfunction requiring alternative pacing strategies
  • Inadequate echocardiographic image quality
  • Inability to comply with study procedures
  • Refusal to participate in the study

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • University of Health Sciences Bursa Yuksek Ihtisas Training and Research Hospital

    Bursa, Yıldırım

Other trials in Turkey (Türkiye)

About this study

Official title: The Effect Of Atrioventricular Delay Optimization On Ventricular Functions In Patients Undergoing Conduction System Pacing

Conduction system pacing has emerged as a physiological pacing strategy that preserves ventricular electrical activation and minimizes pacing-induced dyssynchrony. However, the optimal atrioventricular delay setting in patients undergoing conduction system pacing remains uncertain.

This study aims to evaluate the effects of individualized echocardiography-guided atrioventricular delay optimization on ventricular function and hemodynamic performance in patients with conduction system pacing. Echocardiographic parameters including global longitudinal strain, left ventricular ejection fraction, left ventricular outflow tract velocity-time integral, cardiac output, and diastolic function indices will be assessed before and after atrioventricular delay optimization.

The study will investigate whether optimization of atrioventricular timing provides additional mechanical and hemodynamic benefits beyond physiological ventricular activation achieved by conduction system pacing alone.

Read the detailed description

Conduction system pacing (CSP), including His bundle pacing and left bundle branch area pacing, has emerged as a physiological pacing strategy capable of preserving ventricular electrical activation and reducing pacing-induced dyssynchrony. Compared with conventional right ventricular pacing, CSP has been associated with improved electrical synchrony, ventricular function, and clinical outcomes.

Despite restoration of physiological ventricular activation, optimal atrioventricular (AV) coupling remains essential for maximizing ventricular filling, stroke volume, and overall cardiac performance. Inadequate AV timing may impair diastolic filling, reduce atrial contribution to ventricular preload, and limit the hemodynamic benefits achieved by physiological pacing. While AV delay optimization has been extensively investigated in cardiac resynchronization therapy, data regarding its role in patients undergoing CSP remain limited.

The present study evaluates the impact of individualized echocardiography-guided AV delay optimization on ventricular mechanical performance and hemodynamic parameters in patients with CSP implanted for atrioventricular block. Comprehensive transthoracic echocardiographic assessment will be performed before and after AV delay optimization. Measurements include left ventricular ejection fraction, global longitudinal strain, left ventricular outflow tract velocity-time integral, cardiac output, chamber dimensions, pulmonary artery systolic pressure, and diastolic function parameters.

The primary objective is to determine the effect of AV delay optimization on global longitudinal strain. Secondary objectives include assessment of changes in left ventricular systolic function, hemodynamic performance, and diastolic parameters. The study aims to provide additional evidence regarding the importance of individualized AV programming in patients undergoing conduction system pacing.

Being tested
Echocardiography-Guided Atrioventricular Delay Optimization
Keywords
Atrioventicular Block, Atrioventricular Delay Optimization, Conduction System Pacing, Global Longitudinal Strain, Mechanical Resynchronization, Ventricular Function
Medical subject headings
Atrioventricular Block

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Echocardiography-Guided Atrioventricular Delay OptimizationDevice

    Also called AV Delay Optimization

    Atrioventricular delay settings are individually optimized using echocardiographic assessment of transmitral inflow and ventricular filling patterns. Device programming is adjusted to achieve optimal atrioventricular coupling and ventricular performance.

Study groups in NCT07624552
Study groupRoleWhat they receive
Echocardiography-Guided AV Delay OptimizationExperimentalParticipants with conduction system pacing undergo individualized echocardiography-guided atrioventricular delay optimization. Echocardiographic and hemodynamic parameters are assessed before and after optimization.
Receives: Device: Echocardiography-Guided Atrioventricular Delay Optimization

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Global Longitudinal Strain (GLS)

    Assessment of left ventricular global longitudinal strain using two-dimensional speckle tracking echocardiography before and after atrioventricular delay optimization.

    Measured: Immediately before and immediately after atrioventricular delay optimization.

Secondary outcomes (2)
  1. Left Ventricular Outflow Tract Velocity-Time Integral (LVOT VTI)

    Assessment of forward stroke volume using pulsed-wave Doppler measurements at the left ventricular outflow tract.

    Measured: Immediately before and immediately after atrioventricular delay optimization.

  2. Left Ventricular Ejection Fraction (LVEF)

    Assessment of left ventricular systolic function using the biplane Simpson method.

    Measured: Immediately before and immediately after atrioventricular delay optimization.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Jun 2026
  2. Study start6 Oct 2025
  3. Primary completion17 Feb 2026
  4. Study completion17 Feb 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
This is a prospective, single-center, single-group interventional study. All enrolled participants with conduction system pacing undergo individualized echocardiography-guided atrioventricular delay optimization. Ventricular function and hemodynamic parameters are evaluated before and after optimization using transthoracic echocardiography. Each participant serves as his or her own control for outcome assessment.
Masking
None (open label)
Enrolment
39 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07624552
Sponsor's protocol ID
BYIEAH-CSP-BMU-2025
Other IDs
2024-TBEK 2025/07-12
Acronym
OPTI-CSP
Status last verified
Jun 2026
First submitted
29 May 2026
Last updated
8 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Glikson et al. ESC Clinical Consensus Statement on Conduction System Pacing Glikson M, Vijayaraman P, Ellenbogen KA, et al. European Society of Cardiology (ESC) clinical consensus statement on indications for conduction system pacing. Europace. 2025;27(4):euaf050. Coluccia et al. Optimization of the Atrioventricular Delay in Conduction System Pacing Coluccia G, Padeletti L, Della Bella P, et al. Optimization of the atrioventricular delay in conduction system pacing. J Cardiovasc Electrophysiol. 2023;34(6):1441-1451. Pujol-López et al. LEVEL-AT Trial Secondary Findings Pujol-López M, et al. Longitudinal comparison of dyssynchrony correction and strain improvement by conduction system pacing: LEVEL-AT trial secondary findings. Eur Heart J Cardiovasc Imaging. 2024;25(10):1394-1404. Hua et al. Comparison of Left Bundle Branch and His Bundle Pacing Hua W, Fan X, Niu H, et al. Comparison of left bundle branch and His bundle pacing in bradycardia patients. JACC Clin Electrophysiol. 2020;6(10):1291-1299. Sweeney et al. Adverse Effect of Ventricular Pacing Sweeney MO, Hellkamp AS, Ellenbogen KA, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration. Circulation. 2003;107(23):2932-2937.

Questions about this trial

What is this clinical trial studying?

A study testing Echocardiography-Guided Atrioventricular Delay Optimization in people with Atrioventricular Block and Conduction System Pacing, run by Bursa Yuksek Ihtisas Training and Research Hospital at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Global Longitudinal Strain (GLS) (time frame: Immediately before and immediately after atrioventricular delay optimization.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07624552, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jun 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
OPTI-CSP Clinical Trial NCT07624552 | AzTrials