AzTrials
AzTrials

Aerosol TherapyPhase 4NCT07633223

Evaluation of Time-Sensitive Nebulization Mode Converter

A Phase 4 study testing Cross-over Nebulization Modes Comparison System in people with Aerosol Therapy and Asthma, run by Beni-Suef University at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study utilizes a randomized crossover design to evaluate and compare the clinical and technical efficacy of different nebulization modes for aerosol drug delivery. By implementing a within-subject comparison, each participant will receive the two designated aerosol delivery interventions under distinct… Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Aerosol Therapy, Asthma
What is being tested?
Cross-over Nebulization Modes Comparison System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
36 participants
Where
1 siteEgypt
Study dates
1 Sep 2024to 30 Aug 2025
Phase
Phase 4
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Mild to moderate asthmatic patients.

Who cannot join

  • Severe asthmatic patients.
  • Patients admitted to an intensive care unit
  • Ischemic heart disease.
  • Recent abdominal surgery.
  • Hepatic or renal impairment.
  • Hypersensitivity to salbutamol

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Beni-Suef University Hospital

    Banī Suwayf, Beni Suweif Governorate, 62511

Other trials in Egypt

About this study

Official title: "Evaluation of Efficacy and Clinical Pharmacokinetic Parameters of Different Nebulization Modes"

This study utilizes a randomized crossover design to evaluate and compare the clinical and technical efficacy of different nebulization modes for aerosol drug delivery. By implementing a within-subject comparison, each participant will receive the two designated aerosol delivery interventions under distinct, controlled protocols. The primary objective is to determine whether synchronization of aerosol generation with the inspiratory phase could improve respirable aerosol delivery, enhance pulmonary drug deposition, and reduce aerosol loss during exhalation without significantly altering aerosol aerodynamic particle size distribution characteristics. This research aims to optimize nebulization practices and establish evidence-based guidelines for enhanced respiratory drug administration.

Read the detailed description

Study Design and Participants This study was designed to evaluate the performance of the proposed nebulizer mode converter using both in-vitro and ex-vivo models. The study involved healthy adult volunteers who provided informed consent before participating in the study. The aim was to assess drug delivery efficiency and medication wastage when using conventional jet nebulizers (JNs) compared to the modified nebulization system incorporating the mode converter. Each participant received the inhaled medication via both modes of nebulization-continuous jet nebulization and intermittent nebulization facilitated by the mode converter to allow for a direct comparison of drug deposition efficiency and aerosol delivery.

Experimental Models Two experimental setups were utilized: an in-vitro model employing a breathing simulator and an ex-vivo model involving human volunteers. The in-vitro model used a high-fidelity breathing simulator programmed to replicate a standardized adult respiratory pattern. The simulator was set to an inhalation-to-exhalation (I:E) ratio of 1:2, a respiratory rate of 20 breaths per minute, and a tidal volume of 500 mL. The inhaled drug dose, residual drug volume within the nebulizer chamber, and deposition of salbutamol sulfate within the delivery tubing (connection tube used to connect the jet nebulizer with the filter, which is used for collection of delivered aerosols) were measured to assess efficiency. In the ex-vivo model, each volunteer inhaled the aerosolized medication while an inhalation filter was placed between the nebulizer and the subject's airway to collect the delivered drug. As with the in-vitro model, residual drug amounts within the nebulizer chamber and salbutamol sulfate deposition within the delivery tubing were also measured. This setup enabled direct assessment of the proportion of medication that reached the subject's respiratory tract under both continuous and intermittent nebulization conditions. To ensure the reliability of results, each nebulization mode underwent ten repeated runs in both models. A jet nebulizer of the same commercial model was used for all in-vitro and ex-vivo experiments to maintain consistency and eliminate variability associated with differences between individual nebulizers. Experiments were conducted under normal ambient laboratory conditions, with room temperature maintained at 22-24 °C and relative humidity between 40-55%.

The experimental model setup was designed to evaluate the performance of the nebulization mode converter in comparison to conventional continuous nebulization. The system consisted of a standard jet nebulizer (Planet Health Wheeze nebulizer, Planet Health, Vapo Healthcare Co., Ltd, China), a breathing simulator (5600i, Michigan Instruments, USA), and an intermittent aerosol converter device (EGPO-SES, EG/P/2025/361).[1] Three distinct configurations were examined to assess aerosol generation and delivery under different operating conditions (Figure 1). In the ex-vivo model, the intermittent aerosol converter did not rely on flow-triggered breath sensing. Instead, the inspiratory and expiratory durations of each subject were measured using the Certifier FA Plus and used to set a time-based cycling pattern in which the converter switched on during the subject's inhalation interval (allowing passage of compressed air to the nebulizer head) and off during the exhalation interval. Both inhalation and exhalation times were fully adjustable by the subject, who could reset these intervals at any time to match changes in their spontaneous breathing pattern. The device also produced a fine click sound when transitioning between inhalation and exhalation phases, providing an audible cue that helped the subject maintain synchronization with the intermittent aerosol release.

In the clinical (ex-vivo) model, the inspiratory-to-expiratory (I:E) ratio was determined using the Certifier FA Plus high-flow analyzer (TSI Incorporated, USA). This device provides real-time respiratory measurements, including inspiratory time, expiratory time, and overall breathing cycle parameters. It was used to precisely determine the I:E ratio in volunteers receiving nebulized therapy, ensuring standardized respiratory conditions across all participants.

To ensure accuracy and consistency, the I:E ratio was measured multiple times for each participant, with the means of the most stable readings being used for data analysis. These measurements were critical in evaluating the synchronization of aerosol generation with the inhalation phase when using the nebulization mode converter. The recorded I:E ratios were then used to compare aerosol deposition efficiency between continuous and intermittent nebulization modes.

Each volunteer received the medication with two nebulization modes: the first is the continuous mode without using the nebulization mode converter, and the second is the intermittent mode through incorporation of the nebulization mode converter, as shown in Figure 1.

By integrating the Certifier FA Plus into the study protocol, precise and reproducible respiratory parameters were obtained, enhancing the validity of the ex-vivo experimental results. This approach ensured that the study accurately simulated clinical conditions, providing a robust assessment of the nebulization mode converter's effectiveness in optimizing aerosol therapy.

Nebulization Procedure For each experimental run, 1 mL of salbutamol sulfate respirator solution (Farcolin, 6050 μg/mL; Pharco Pharmaceuticals, Egypt) was placed inside the nebulizer chamber. The breathing simulator and ventilator were turned on 30 seconds before nebulizer activation to establish a stable and reproducible respiratory cycle. The nebulizers were operated under standardized conditions until the sputtering phase, which signified the near-complete aerosolization of the drug solution. During ex-vivo experiments, volunteers inhaled the medication through both the conventional jet nebulizer mode and the modified mode with the converter in separate sessions, allowing for comparative analysis of drug deposition.

Drug Collection and Analysis Following nebulization, all inhalation filters and nebulizer chambers were systematically rinsed with 90% acetonitrile (v/v) to recover any residual drug content. The collected samples were then subjected to sonication to ensure complete extraction of salbutamol sulfate. Drug quantification was performed using high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection. The HPLC system employed was the Agilent 1260 Infinity Diode Array Detector VL (G131SD, Agilent, USA), configured to detect salbutamol sulfate at a wavelength of 225 nm. A mobile phase composed of a 90:10 (v/v) acetonitrile-to-water mixture containing 0.1% phosphoric acid was used, with a flow rate of 1 mL/min. The separation was achieved using a ZORBAX Eclipse Plus C18 column (25 × 4.6 mm, Agilent, USA), with an injection volume of 100 μL. The detection sensitivity was optimized with a lower limit of detection (LOD) of 0.35 μg/mL and a lower limit of quantification (LOQ) of 2.55 μg/mL, ensuring precise and accurate measurements of delivered and residual drug amounts.[2, 3] Breathing Simulator Settings To replicate adult breathing conditions, a Michigan Instruments 5600i breathing simulator (USA) was employed. The simulator was programmed with an inhalation-to-exhalation ratio of 1:2, a respiratory rate of 20 breaths per minute, and a tidal volume of 500 mL. These settings ensured standardized and reproducible conditions across all experimental runs. This controlled experimental approach allowed for a thorough and scientifically rigorous evaluation of aerosol drug delivery efficiency between conventional jet nebulization and the modified intermittent nebulization system facilitated by the mode converter.

Ethical considerations:

The current study has been ethically reviewed and approved by the Research Ethical Committee (FM-BSU REC), Faculty of Medicine, Beni-Suef University, under Approval No: FMBSUREC/01092024.

Study Design and Participants The present study employed a combined in-vitro aerodynamic characterization model and an in-vivo clinical pharmacokinetic model to evaluate the aerosol delivery performance of a conventional jet nebulizer with and without integration of the Breath-Synchronized Nebulization Mode Converter (NMC).

The in-vitro aerodynamic characterization model was designed to assess aerosol particle deposition characteristics under simulated physiological breathing conditions. Aerosol performance was evaluated using an Andersen Cascade Impactor Mark II (ACI, Copley Scientific, UK) integrated with a custom-designed breathing simulation platform capable of reproducing synchronized inspiratory and expiratory phases.

The in-vivo clinical pharmacokinetic model was conducted to evaluate pulmonary bioavailability and effective lung deposition associated with both nebulization modes. The clinical study included asthmatic patients who received aerosolized salbutamol sulfate using conventional continuous nebulization and breath-synchronized intermittent nebulization in a randomized crossover design. Pulmonary bioavailability was assessed using urinary salbutamol excretion collected 30 minutes after completion of nebulization (USAL 0.5), a validated surrogate marker of pulmonary drug deposition following inhalation therapy.

Experimental Models The aerodynamic performance of aerosolized salbutamol sulfate generated by the conventional jet nebulizer and the jet nebulizer integrated with the Nebulization Mode Converter (NMC) was evaluated using an Andersen Cascade Impactor Mark II (ACI, Copley Scientific, UK) operated at a calibrated flow rate of 15 L/min. [4] To simulate physiologically relevant respiratory conditions, a custom-designed breathing simulation platform was incorporated into the experimental setup. The simulator consisted of two independently controlled pumps connected to an automated timing-control unit: a vacuum pump to simulate the inspiratory phase, and a positive-pressure air pump to simulate the expiratory phase.

The transition between inspiratory and expiratory phases was controlled electronically using a programmable timing module configured according to predefined inspiratory-to-expiratory (I: E) ratios representative of spontaneous tidal breathing patterns.

During the inspiratory phase, negative pressure generated by the vacuum pump created directional airflow through the nebulizer-mouthpiece assembly toward the cascade impactor, simulating pulmonary aerosol inhalation. During the expiratory phase, the inspiratory pathway was interrupted while the expiratory pump generated reverse airflow to simulate exhaled breathing conditions.

For the intermittent nebulization arm, the Nebulization Mode Converter synchronized aerosol generation exclusively with the inspiratory phase by controlling compressed air delivery to the nebulizer chamber. Aerosol production was automatically interrupted during simulated exhalation, thereby minimizing aerosol loss during the expiratory period.

In contrast, the conventional nebulization mode continuously generated aerosol throughout both inspiratory and expiratory phases, independent of the breathing cycle.

This experimental configuration enabled dynamic evaluation of aerosol generation under breathing conditions closely resembling clinical respiratory patterns rather than static continuous-flow testing.

High-performance liquid chromatography Method:

Following aerosol collection, the stages and collection plates of the Andersen Cascade Impactor were rinsed with 90% acetonitrile (v/v) and subjected to sonication to ensure complete recovery of deposited salbutamol sulfate. Quantitative analysis of salbutamol was subsequently performed using a validated ultraviolet high-performance liquid chromatography (UV-HPLC) method utilizing an Agilent 1260 Infinity HPLC system (Agilent Technologies, USA), as previously described in earlier studies. [2, 3, 5, 6] To ensure experimental consistency and minimize device-related variability, the same commercial model of jet nebulizer was used throughout all in-vitro investigations. All experiments were conducted under standardized laboratory conditions, with ambient temperature maintained between 22 and 24 °C.

The clinical model:

The clinical pharmacokinetic model included 36 asthmatic patients who provided written informed consent prior to participation in the study. The study was designed to compare pulmonary bioavailability achieved using conventional continuous jet nebulization with that obtained using a Breath-Synchronized Nebulization Mode Converter integrated with the same jet nebulizer system.

Ethical considerations:

The current study has been ethically reviewed and approved by the Research Ethical Committee (FM-BSU REC), Faculty of Medicine, Beni-Suef University, under Approval No: FMBSUREC/01092024.

Each participant received aerosolized salbutamol sulfate using both nebulization modes in a randomized crossover design. The two intervention arms included: (1) conventional continuous nebulization without incorporation of the Nebulization Mode Converter, and (2) breath-synchronized intermittent nebulization using the Nebulization Mode Converter integrated with the jet nebulizer. Each nebulization mode was administered on separate study days (day 1 and day 3) with random assignment of the initial intervention sequence and an adequate washout period between sessions to minimize carryover effects.

This crossover design enabled direct within-subject comparison of pulmonary drug bioavailability and aerosol delivery performance between both nebulization modes while minimizing intersubject variability.

Prior to aerosol administration, the inspiratory-to-expiratory (I: E) ratio for each participant was determined using a Certifier FA Plus high-flow analyzer (TSI Incorporated, USA). This system provides real-time respiratory measurements, including inspiratory time, expiratory time, respiratory cycle duration, and breathing pattern characteristics. The device was used to accurately characterize individual respiratory profiles and to optimize synchronization of aerosol generation with the inspiratory phase during breath-synchronized intermittent nebulization.

To ensure measurement precision and reproducibility, respiratory parameters were assessed repeatedly for each participant, and the mean of the most stable recordings was used for analysis. These measurements were essential for accurate temporal alignment between aerosol release and the inspiratory phase throughout nebulization sessions.

Each participant received aerosolized salbutamol sulfate consisting of 1 mL Farcolin® solution containing 6050 µg salbutamol sulfate diluted with 2 mL normal saline placed within the nebulizer chamber. Aerosol therapy was administered using two nebulization modes: (1) conventional continuous nebulization without incorporation of the Nebulization Mode Converter, and (2) breath-synchronized intermittent nebulization using the Nebulization Mode Converter integrated with the jet nebulizer system. Both nebulization modes were administered on separate study days with an adequate washout period between sessions to minimize carryover effects.

Sample size estimation was performed using G*Power software (version 3.1, Heinrich Heine University, Düsseldorf, Germany). The calculation was based on findings from a previously published ex vivo study evaluating the Nebulization Mode Converter, which demonstrated significantly improved salbutamol delivery during intermittent nebulization compared with conventional continuous nebulization.[7] Because the previous experimental model demonstrated a very large effect size under controlled laboratory conditions, a conservative large clinical effect size (Cohen's dz = 0.90) was selected for estimation of the current in-vivo crossover study to account for anticipated variability in respiratory patterns and urinary pharmacokinetic measurements. Using a paired-samples t-test, with a two-sided alpha level of 0.05 and a statistical power of 80%, the minimum required sample size was estimated to be 15 participants. To improve statistical robustness and compensate for potential variability and dropouts, 36 asthmatic patients were ultimately recruited.

Participants were instructed to empty their bladders 15 minutes prior to aerosol administration to minimize the influence of residual urinary salbutamol on pharmacokinetic assessment. Urine samples were subsequently collected 30 minutes after completion of nebulization, and total urine volume was recorded for each participant. Collected samples were stored at -20 °C until analysis.

Urinary salbutamol sulfate was extracted using a solid-phase extraction (SPE) technique prior to quantitative analysis. Salbutamol concentrations were then determined using a validated high-performance liquid chromatography (HPLC) method performed on an Agilent 1260 Infinity system (Agilent Technologies, USA), as previously described in published analytical methodologies.[8-10] Early urinary salbutamol excretion at 30 minutes (USAL 0.5) was used as a validated surrogate marker of pulmonary bioavailability and lower respiratory tract drug deposition following inhalation therapy.

Statistical Analysis Statistical analysis was performed using IBM SPSS Statistics software (version 26.0; IBM Corp., Armonk, NY, USA). Continuous variables were expressed as mean ± standard deviation (SD), whereas categorical variables were presented as frequencies and percentages. Normality of data distribution was assessed using the Shapiro-Wilk test in addition to visual inspection of histograms and Q-Q plots. Because the study utilized a paired crossover design in which each participant underwent both continuous and breath-synchronized intermittent nebulization, within-subject comparisons were performed using paired-samples t-tests for normally distributed variables. Non-parametric data, when applicable, were analyzed using the Wilcoxon signed-rank test.

Aerodynamic characterization parameters, including Fine Particle Dose (FPD ≤3 µm and ≤5 µm), Fine Particle Fraction (FPF% ≤3 µm and ≤5 µm), and Mass Median Aerodynamic Diameter (MMAD), were compared between nebulization modes. In the clinical pharmacokinetic model, urinary salbutamol excretion at 30 minutes (USAL 0.5) was analyzed as a surrogate marker of pulmonary bioavailability and lower respiratory tract deposition. All statistical tests were two-tailed, and a p-value <0.05 was considered statistically significant.

Being tested
Cross-over Nebulization Modes Comparison System
Keywords
mode of nebulization, intermittent nebulization, Nebulization mode converter, Aerosol therapy
Medical subject headings
Asthma

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Cross-over Nebulization Modes Comparison SystemDevice

    A device-based cross-over intervention designed to compare different nebulization delivery modes within the same subjects under controlled conditions. Each participant receives aerosolized therapy using multiple nebulization modes in a randomized cross-over sequence with standardized drug formulation and dose. The intervention is used to evaluate differences in aerosol performance, including particle size distribution, lung deposition efficiency, and pulmonary bioavailability, while minimizing inter-subject variability.

  • Cross-over Nebulization Modes Comparison SystemDrug

    use of salbutamol sulfate to compare different nebulization delivery modes within the same subjects under controlled conditions. Each participant receives aerosolized therapy using multiple nebulization modes in a randomized cross-over sequence with standardized drug formulation and dose. The intervention is used to evaluate differences in aerosol performance, including particle size distribution, lung deposition efficiency, and pulmonary bioavailability, while minimizing inter-subject variability.

Study groups in NCT07633223
Study groupRoleWhat they receive
Patient with Intermittent Nebulization ModeActive comparatorParticipants will receive nebulization using the first intervention (intermittent mode) according to the study protocol during the first study period. Aerosol delivery performance and relevant study outcomes (TED and USAL 0.5) will be assessed. Following completion of this phase, participants will undergo a crossover to the alternate intervention after the designated washout period.
Receives: Device: Cross-over Nebulization Modes Comparison System; Drug: Cross-over Nebulization Modes Comparison System
Patient with Continuous Nebulization ModeActive comparatorParticipants will receive nebulization using the second intervention (continuous mode) according to the study protocol during the crossover study period. Aerosol delivery performance and relevant study outcomes (such as TED and USAL 0.5) will be evaluated and compared with those observed during the first intervention period.
Receives: Device: Cross-over Nebulization Modes Comparison System; Drug: Cross-over Nebulization Modes Comparison System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Amount of aerosols

    The amount of aerosolized drug delivered (TED) and deposited in the lungs following nebulization will be evaluated. Drug deposition efficiency will be assessed using predefined aerosol delivery assessment methods under standardized study conditions. Results will be compared between nebulization interventions to determine differences in pulmonary drug delivery performance.

    Measured: From enrollment to the end of treatment, at 1 week per participant.

  2. Lung Bioavailability

    Pulmonary bioavailability of the aerosolized drug will be assessed to evaluate the extent of drug availability in the lungs after nebulization. A relevant pharmacokinetic parameter, urinary salbutamol excretion at 30 minutes (USAL0.5), will be analyzed to compare pulmonary drug delivery efficiency between interventions.

    Measured: From enrollment to the end of treatment, at 1 week per participant.

  3. Particle Size Distribution

    Aerodynamic particle size distribution generated during nebulization will be measured to assess aerosol quality and respirable fraction. Particle size parameters will be analyzed and compared between nebulization interventions to determine differences in aerosol generation performance and lung delivery potential.

    Measured: Within 4 weeks per each arm of the study.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Jun 2026
  2. Study start1 Sep 2024
  3. Primary completion1 Aug 2025
  4. Study completion30 Aug 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
36 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07633223
Sponsor's protocol ID
FMBSUREC/01092024
Status last verified
Jun 2026
First submitted
3 Jun 2026
Last updated
8 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Sabry, M., et al. (2026). "Development and Evaluation of a Time-Sensitive Nebulization Mode Converter for Optimized Aerosol Drug Delivery." Journal of Pharmaceutical Innovation 21(2): 166.

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing Cross-over Nebulization Modes Comparison System in people with Aerosol Therapy and Asthma, run by Beni-Suef University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 8 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Amount of aerosols (time frame: From enrollment to the end of treatment, at 1 week per participant.). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07633223, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jun 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in