AzTrials
AzTrials

Spinal Cord Injuries (SCI)NCT07639541

Radio-frequency (RF) Bladder Monitor

A study testing Wearable microwave Bladder Monitoring System in people with Spinal Cord Injuries (SCI) and Neurogenic Lower Urinary Tract Dysfunction, run by McGill University Health Centre/Research Institute of the McGill University Health Centre at 1 site in Canada.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this pilot feasibility study is to evaluate a wearable microwave (MW)-based bladder monitoring system in adult volunteers and those with spinal cord injury (SCI) who use self-catheterization for bladder management. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
What is being tested?
Wearable microwave Bladder Monitoring System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
40 participants
Where
1 siteCanada
Study dates
1 Jul 2026to 31 Mar 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Age > 18
  • Able/willing to sit (or stand) in place for the time it takes for bladder to fill once.
  • No implanted devices
  • Able to toilet/void independently
  • No pregnancy

Who cannot join

  • Age < 18
  • Implanted devices (e.g., pacemakers)
  • Unable to toilet without assistance
  • Unable to stay relatively still for the time it takes bladder to fill once
  • Pregnancy

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Canada1 site
  • Centre for Innovative Medicine (CIM) - McGill University Health Centre (MUHC)

    Montreal, Quebec, H4A 3J1

    Emily Porter, Ph.D., 514-934-1934 ext. 37794, emily.porter@mcgill.ca

    Emily Porter, Ph.D.

Other trials in Canada

About this study

The goal of this pilot feasibility study is to evaluate a wearable microwave (MW)-based bladder monitoring system in adult volunteers and those with spinal cord injury (SCI) who use self-catheterization for bladder management. The study aims to learn whether the device can monitor bladder filling and estimate bladder volume non-invasively.

The main questions the study aims to answer are:

Read more
  1. Can the MW-based monitoring system distinguish between non-full and full bladder states?
  2. How accurately do MW-based bladder volume estimates agree with ultrasound bladder scans and voided urine volumes?
  3. Is the wearable monitoring system feasible, comfortable, and usable for individuals with SCI?

Participants will:

  1. Complete questionnaires about bladder symptoms and quality of life
  2. Wear up to six non-invasive MW sensors on the lower pelvic region
  3. Undergo two bladder filling and voiding cycles during the study visit
  4. Have MW measurements collected approximately every five minutes during bladder filling
  5. Undergo ultrasound bladder scans and bladder volume measurements for comparison
  6. Complete a post-study usability and comfort survey
Read the detailed description

Spinal cord injury (SCI) presents significant long-term challenges for affected individuals, among which bladder dysfunction is a leading concern. Neurogenic lower urinary tract dysfunction (NLUTD), commonly referred to as neurogenic bladder dysfunction, may result in urinary retention, incomplete bladder emptying, urinary incontinence, urinary tract infections (UTIs), bladder distension, urinary reflux, renal complications, and reduced quality of life. Current bladder management approaches, including clean intermittent catheterization (CIC), indwelling catheterization, and external collection methods, may be associated with substantial time burden, complications, excessive bladder filling or incomplete emptying, and poor adherence. Studies have also shown that improving bladder function remains one of the highest rehabilitation priorities among individuals with SCI.

This study investigates the feasibility of a wearable radio-frequency (RF)-based bladder monitor operating in the microwave (MW) frequency range for non-invasive bladder monitoring and bladder volume estimation. The proposed system is intended to measure and track bladder volume and may ultimately support future development of discreet alerts indicating when the bladder is appropriately full and it is time to void. RF/MW sensing approaches provide several potential advantages for bladder monitoring applications because they are non-invasive, low-cost, safe for repeated use within established exposure limits, and compatible with wearable device designs.

Previous computational and experimental studies investigating RF/MW approaches for bladder-state detection have demonstrated proof-of-concept feasibility; however, many earlier studies relied on simplified anatomical models and limited experimental conditions. More recent work by the investigators demonstrated bladder-state discrimination using realistic anatomical pelvic models and preliminary measurements in healthy volunteers. This study includes measurements in both healthy volunteers and individuals with SCI who self-catheterize.

The objectives of the study are:

  1. to provide a clinical proof-of-concept demonstration of MW bladder monitoring and bladder volume quantification; and ii) to provide data regarding the short-term functionality, utility, and comfort of the wearable MW bladder monitoring prototype.

The study will enroll adult healthy volunteers and adult participants with SCI who use self-catheterization for bladder management. Following informed consent, participants with SCI may complete questionnaires related to bladder dysfunction and bladder-related quality of life, including the Neurogenic Bladder Symptom Score Short Form (NBSS-SF).

Participants will undergo bladder filling and voiding cycles during the study visit. At the beginning of the session, participants will be asked to void their bladder using their usual voiding or catheterization method. For participants in whom pregnancy is possible, urine pregnancy testing may be performed prior to RF measurements. Ultrasound bladder scans will be performed at empty and full bladder states and will serve as reference measurements for bladder volume estimation. Voided urine volumes will also be collected during voiding phases.

The MW bladder monitoring prototype will be placed externally on the lower pelvic region by study personnel. Up to six sensors may be used. Sensors will be secured using adhesive bandages or wrap-style fixation methods. No skin preparation, gels, or invasive procedures are required. MW measurements will be collected automatically approximately every five minutes while the bladder fills naturally. Participants may rest or perform sedentary activities during the measurement period. Measurements will continue until bladder fullness is reached or the participant requests to void. The bladder filling and emptying process may then be repeated for a second cycle during the same study visit.

Collected MW measurement data will be analyzed to investigate signal trends and the feasibility of the technology. Planned analyses include:

  • Bladder fullness classification through comparison of MW signal trends between non-full and full bladder states;
  • Bladder volume quantification using raw measurement data and reconstructed radar image data;
  • Comparison of MW-based bladder volume estimates with ultrasound-estimated bladder volumes and voided urine volumes.

Exploratory analyses will evaluate signal trends across the measured frequency range to select optimal frequency points, measurement variability, and sex-based differences in MW measurements. Participant and clinician feedback surveys will additionally be used to assess device comfort, usability, and utility for bladder monitoring applications.

As a final remark, this pilot feasibility study is intended to generate preliminary clinical data supporting further development and optimization of wearable MW bladder monitoring technology and may support future larger clinical investigations aimed at improving bladder management for individuals living with bladder dysfunction, including neurogenic bladder associated with SCI. The investigational device is considered low risk. The device is non-invasive and uses low-power RF/MW signals for sensing and monitoring purposes only.

Being tested
Wearable microwave Bladder Monitoring System
Keywords
Spinal Cord Injury, Neurogenic Bladder, Neurogenic Lower Urinary Tract Dysfunction, Bladder Monitoring, Bladder Management, Microwave Sensing, Radio-Frequency Sensing, Wearable Medical Device, Bladder Fullness Detection, Bladder Volume Estimation, Non-Invasive Monitoring, Assistive Technology, Pilot Feasibility Study, Urology
Medical subject headings
Spinal Cord Injuries, Urinary Bladder, Neurogenic

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Wearable microwave Bladder Monitoring SystemDevice

    The investigational device is a non-invasive wearable microwave (MW) bladder monitoring system designed to monitor bladder filling and estimate bladder volume. The system uses low-power radio-frequency (RF) signals and externally applied sensors positioned over the lower pelvic region to collect electromagnetic measurements associated with bladder filling. Measurements will be collected approximately every five minutes during natural bladder filling cycles. The device is intended for investigational use only and does not provide therapeutic intervention or automated clinical decision-making.

Study groups in NCT07639541
Study groupRoleWhat they receive
Microwave Bladder Monitoring in Individuals with Spinal Cord InjuryExperimentalHealthy participants and participants with spinal cord injury (SCI) who use self-catheterization for bladder management will undergo non-invasive microwave (MW)-based bladder monitoring during two bladder filling and voiding cycles. Up to six externally applied MW sensors will be positioned over the lower pelvic region to collect measurements associated with bladder filling. Measurements will be acquired approximately every five minutes while the bladder fills naturally. Ultrasound bladder scans and voided urine volumes will be used as reference measurements for bladder volume estimation and bladder fullness assessment. The study will evaluate the feasibility, usability, comfort, and preliminary performance of the wearable MW bladder monitoring system in both healthy participants and individuals with SCI.
Receives: Device: Wearable microwave Bladder Monitoring System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mean difference in microwave S-parameter magnitude between full and empty bladder states (dB)

    Microwave S-parameter measurements collected during bladder filling and voiding cycles will be compared between empty and full bladder states. The outcome will be reported as the mean difference and standard deviation in S-parameter magnitude between full and empty bladder states across the measured frequency range, expressed in decibels (dB).

    Measured: Through study completion, an average of 4-8 hours

  2. Mean error of microwave-based bladder volume estimation (mL) relative to ultrasound bladder volume estimates and voided urine volume

    Bladder volume estimates derived from microwave S-parameter measurements will be compared with ultrasound bladder volume estimates and voided urine volumes obtained during bladder filling and voiding cycles. The outcome will be reported as the mean difference and standard deviation between microwave-based bladder volume estimates and the corresponding reference measurements (mL).

    Measured: Through study completion, an average of 4-8 hours

Secondary outcomes (2)
  1. Total score on the investigator-developed post-participation bladder monitor questionnaire

    Participant perceptions of comfort, usability, and utility of the wearable microwave-based bladder monitoring system will be assessed using an investigator-developed post-participation questionnaire. Total scores range from 1 to 10, with higher scores indicating greater comfort, usability, and perceived utility of the device.

    Measured: Day 1

  2. Frequency points exhibiting the greatest difference in microwave S-parameter magnitude between full and empty bladder states (MHz)

    For each participant, differences in microwave S-parameter magnitude between full and empty bladder states will be calculated across the 500-3000 MHz frequency range. The outcome will identify the frequency points and frequency ranges exhibiting the largest bladder-state-dependent signal differences. Analyses will be performed for the overall cohort and separately for male and female participants to assess sex-based differences in optimal frequency selection.

    Measured: Through study completion, an average of 4-8 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Jun 2026
  2. Study start1 Jul 2026 (estimated)
  3. Primary completion31 Dec 2026 (estimated)
  4. Study completion31 Mar 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Model description
The study will include 40 participants: 20 healthy volunteers and 20 patients. All participants will undergo the same protocol.
Masking
None (open label)
Enrolment
40 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07639541
Sponsor's protocol ID
2025-10205
Other IDs
CDMRP-SC240005, 2025
Status last verified
Jun 2026
First submitted
1 Jun 2026
Last updated
10 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: De-identified microwave measurement data may be published. No personally identifiable participant information will be shared.

Publications

  • A. Farshkaran and E. Porter, "Importance of Sex-Based Modelling of the Pelvic Region for Microwave Medical Applications," 2022 IEEE MTT-S International Microwave Biomedical Conference (IMBioC), Suzhou, China, 2022, pp. 1-3, doi: 10.1109/IMBioC52515.2022.9790287. keywords: {Microwave technology;Biomedical equipment;Biological system modeling;Conferences;Scattering;Medical services;Physiology;bladder;microwave medical applications;pelvic region}

  • A. Raterink, A. Farshkaran and E. Porter, "Microwave Reflection-based Bladder State Discrimination with Realistic Pelvic Models: Impact of Urine Conductivity and Volume," 2021 IEEE MTT-S International Microwave and RF Conference (IMARC), KANPUR, India, 2021, pp. 1-4, doi: 10.1109/IMaRC49196.2021.9714587. keywords: {Microwave antennas;Solid modeling;Shape;Bladder;Conductivity;Microwave theory and techniques;Dielectrics;bladder;microwave imaging;pelvic region model.}

  • E. Porter, A. Raterink and A. Farshkaran, "Microwave-Based Detection of the Bladder State as a Support Tool for Urinary Incontinence [Bioelectromagnetics]," in IEEE Antennas and Propagation Magazine, vol. 64, no. 1, pp. 112-122, Feb. 2022, doi: 10.1109/MAP.2021.3129687. keywords: {Wireless communication;Ultrasonic imaging;Magnetic resonance imaging;Computed tomography;Wearable computers;Microwave devices;Monitoring}

  • Farshkaran A, Fry A, Raterink A, Santorelli A, Porter E. Proof-of-Concept of Microwave-Based Bladder State Detection Using Realistic Pelvic Models. IEEE Open J Eng Med Biol. 2023 Aug 16;5:140-147. doi: 10.1109/OJEMB.2023.3305838. eCollection 2024.

    PubMed 38445237

Questions about this trial

What is this clinical trial studying?

A study testing Wearable microwave Bladder Monitoring System in people with Spinal Cord Injuries (SCI) and Neurogenic Lower Urinary Tract Dysfunction, run by McGill University Health Centre/Research Institute of the McGill University Health Centre at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 10 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Emily Porter, Ph.D. (514-934-1934 ext. 37794, emily.porter@mcgill.ca), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mean difference in microwave S-parameter magnitude between full and empty bladder states (dB) (time frame: Through study completion, an average of 4-8 hours). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07639541, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in