AzTrials
AzTrials

Myopia (Disorder)MyopiaTechNCT07645183

Advanced Technology for Myopia Control in Children and Young Adults

A study testing Lenslet Spectacles, Violet Excitation Filter Glasses and Single Vision Lenses in people with Myopia (Disorder) and Refraction Error, run by University of Faisalabad at 1 site in Pakistan.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Myopia, or nearsightedness, is increasing rapidly worldwide, especially in children and young adults. This study tested two advanced treatments for slowing myopia progression with one control group: special lenslet spectacles (Stellest with highly aspherical lenslet technology) and violet excitation filter glasses… Read more about this study

Who is it for?
Ages 8 to 20 years
Conditions the study is for
Myopia (Disorder), Refraction Error
What is being tested?
Lenslet Spectacles, Violet Excitation Filter Glasses and Single Vision Lenses
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
90 participants
Where
1 sitePakistan
Study dates
1 Jul 2025to 6 Jun 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 8 to 20 years
  • All sexes
  • No healthy volunteers
  • Child, Adult

Who may be able to join

  • Diagnosis of axial myopia (high, moderate, or severe)
  • Age between 8 and 20 years (inclusive)
  • Male or female
  • Willingness to wear prescribed glasses as instructed
  • Willingness to attend all follow-up visits (3, 6, and 9 months)
  • Written informed consent from participant or parent/guardian for minors

Who cannot join

  • Any ametropia other than axial myopia (e.g., hyperopia, astigmatism >1.50D)
  • Current contact lens users
  • Prior or concurrent myopia treatment other than study interventions
  • Any ocular disease (e.g., cataract, glaucoma, retinal disorders)
  • Any systemic disease affecting vision (e.g., diabetes, Marfan syndrome)
  • History of any ocular surgery
  • Allergic or physical intolerance to glasses materials
  • Non-cooperative patients unwilling to comply with study procedures

Trial locations and contacts

1 site in 1 country.

Pakistan1 site
  • The University of Faisalabad

    Faisalābad, Punjab Province, 3800

Other trials in Pakistan

About this study

Official title: Role of Advanced Technological Approaches for Myopia Control in Myopic Patients: A Randomized Controlled Trial of Lenslet Spectacles vs. Violet Excitation Filter Glasses vs. Single Vision Lenses

Myopia, or nearsightedness, is increasing rapidly worldwide, especially in children and young adults. This study tested two advanced treatments for slowing myopia progression with one control group: special lenslet spectacles (Stellest with highly aspherical lenslet technology) and violet excitation filter glasses (wavelength 420 nm) and Single vision lenses for controls. The study enrolled 90 participants aged 8 to 20 years from schools and universities in Faisalabad, Pakistan. Participants were randomly assigned to one of three groups: lenslet spectacles, violet filter glasses, or single vision lenses (control group). Visual acuity, contrast sensitivity, Spherical Equivalent and axial length were measured at the start and again after 3, 6, and 9 months and one follow up after cessation of treatment. The study aimed to determine whether these advanced technologies can effectively slow myopia progression compared to standard glasses, providing head-to-head evidence on emerging and established optical interventions for myopia control.

Read the detailed description

This is a randomized controlled trial (RCT) with three parallel groups. The study was conducted at schools and the Universities in Faisalabad, Pakistan. The total study duration was almost one year (July 2025 to May 2026), with each participant undergoing atleast 3 months of active treatment with 3 follow ups. The sample size was 30 participants per group (total N=90), after drop put of patients, calculated using G*Power (repeated measures ANOVA, 3 groups × 4 time points, medium effect size f=0.25, α=0.05, power=0.8). Simple random sampling was used, with participants allocated to groups using an online research randomizer. Inclusion criteria: axial myopia (high, moderate, or severe), age 8-20 years, both genders, willingness to wear glasses. Exclusion criteria:

other ametropia, contact lens users, prior myopia treatment, ocular or systemic disease, ocular surgery, non-cooperative patients. Lenslet group: Essilor Stellest spectacles with Highly Aspheric Lenslet Target technology, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating; worn all waking hours. Violet filter group: plastic lenses with 420nm violet excitation filter; worn 3 hours daily (11 AM to 2 PM) to align with circadian rhythm. Control group: single vision lenses (refractive index 1.56). Primary outcome measures: change in axial length (measured by ocular biometer) and change in cycloplegic refraction. Secondary outcome measures: visual acuity (LogMAR chart), contrast sensitivity (Vistech chart). Follow-up assessments at 3, 6, and 9 months. Statistical analysis: repeated measures Linear mixed model using SPSS version 26 to compare within-group and between-group changes.

Being tested
Lenslet Spectacles, Violet Excitation Filter Glasses, Single Vision Lenses
Keywords
Axial Elongation, Lenslet, Violet Excitation Filter, HALT Technology, Myopia Control
Medical subject headings
Myopia, Refractive Errors

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Lenslet SpectaclesDevice

    The lenslet spectacles are specially designed spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) technology manufactured by Essilor International (Serial Number: 72426930). The lens design includes a clear distance zone in the center with peripheral areas providing single vision correction. Technical specifications: 5H green covering, multi-dimensional pattern, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating. Participants are instructed to wear the spectacles throughout all waking hours. Each participant receives a new pair at baseline. No adjustments are made during the 12-month treatment period unless vision changes require prescription update.

  • Violet Excitation Filter GlassesDevice

    The violet excitation filter glasses are prescription glasses incorporating a violet light filter with wavelength 420 nm (range 360-420 nm). Material: CR-39. Filter intensity: 700 nm. Wavelength verified using spectrophotometer (standard error ±0.1 to 1 nm). Participants are instructed to wear the glasses for 3 hours daily, specifically from 11 AM to 2 PM, to optimize impact on circadian rhythm while avoiding disruption of sleep patterns. Each participant receives a new pair at baseline. The filter is integrated into the prescription lenses.

  • Single Vision LensesDevice

    Standard single vision spectacle lenses (SVS index 1.56) with no myopia control features. These are conventional prescription glasses that correct refractive error but do not incorporate lenslet technology or violet filtering. Participants are instructed to wear the glasses throughout all waking hours. Each participant receives a new pair at baseline.

Study groups in NCT07645183
Study groupRoleWhat they receive
Lenslet Spectacles (HALT TechnologyExperimentalParticipants receive Essilor Stellest spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) anf violet filter glasses technology. Lenses have 1.6mm thickness, refractive index 1.56, UV 400. Participants are instructed to wear glasses throughout all waking hours for 9 months and for VF atleast 3ours.
Receives: Device: Lenslet Spectacles
Violet Excitation Filter GlassesExperimentalParticipants receive prescription glasses with violet excitation filter (420 nm wavelength, CR-39 material). Participants are instructed to wear glasses for 3 hours daily (11 AM to 2 PM) for 12 months to align with circadian rhythm.
Receives: Device: Violet Excitation Filter Glasses
Single Vision LensesActive comparatorParticipants receive standard single vision spectacle lenses (SVS index 1.56). Participants are instructed to wear glasses throughout all waking hours for 12 months.
Receives: Device: Single Vision Lenses

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in Axial Length

    Axial length (mm) measured using an A-SCAN biometer (Scanmate 677AB). The measurement represents the distance from the corneal apex to the retinal pigment epithelium. Three measurements are taken for each eye and averaged. This is a continuous anatomical measurement with no theoretical minimum or maximum score. Higher values indicate greater ocular elongation, which is associated with worsening myopia progression.

    Measured: Baseline, Month 3, Month 6, Month 9

  2. Change in Cycloplegic Refraction

    Cycloplegic spherical equivalent refraction (SER), measured in diopters (D) using retinoscopy (Welch Allyn) after cycloplegia. SER is calculated as sphere + (cylinder/2). This is a continuous measurement with no theoretical minimum or maximum value. A decrease in SER (more negative values) reflects progression of myopia, while an increase in SER (less negative or more positive values) reflects reduced myopia or a shift toward hyperopia.

    Measured: Baseline, Month 3, Month 6, Month 9

Secondary outcomes (2)
  1. Change in Visual Acuity

    Visual acuity measured using the Logarithm of the Minimum Angle of Resolution (LogMAR) Visual Acuity Chart (Precision Vision) at 4 m, 2 m, and 1 m. LogMAR scores typically range from approximately -0.30 (better visual acuity) to 1.60 (poorer visual acuity), although values may extend beyond these limits. Lower scores represent better visual acuity outcomes, and higher scores represent worse visual acuity outcomes.

    Measured: Baseline, Month 3, Month 6, Month 9

  2. Change in Contrast Sensitivity

    Contrast sensitivity measured using the Vistech Contrast Sensitivity Test Chart (Precision Vision) at 1 meter. Contrast sensitivity scores are reported in log contrast sensitivity units and typically range from 0.00 to approximately 2.25. Higher scores represent better contrast sensitivity and visual performance, while lower scores represent poorer contrast sensitivity and visual performance.

    Measured: Baseline, Month 3, Month 6, Month 9

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jun 2026
  2. Study start1 Jul 2025
  3. Primary completion30 May 2026
  4. Study completion6 Jun 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
90 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07645183
Sponsor's protocol ID
TUF/IRB/ 38 /25
Acronym
MyopiaTech
Status last verified
Jun 2026
First submitted
8 Jun 2026
Last updated
25 Jun 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Lenslet Spectacles, Violet Excitation Filter Glasses and Single Vision Lenses in people with Myopia (Disorder) and Refraction Error, run by University of Faisalabad at 1 site in Pakistan.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 25 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Pakistan. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in Axial Length (time frame: Baseline, Month 3, Month 6, Month 9). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Jun 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in