Myopia (Disorder)MyopiaTechNCT07645183
Advanced Technology for Myopia Control in Children and Young Adults
A study testing Lenslet Spectacles, Violet Excitation Filter Glasses and Single Vision Lenses in people with Myopia (Disorder) and Refraction Error, run by University of Faisalabad at 1 site in Pakistan.
Trial summary
Myopia, or nearsightedness, is increasing rapidly worldwide, especially in children and young adults. This study tested two advanced treatments for slowing myopia progression with one control group: special lenslet spectacles (Stellest with highly aspherical lenslet technology) and violet excitation filter glasses… Read more about this study
- Who is it for?
- Ages 8 to 20 years
- Conditions the study is for
- Myopia (Disorder), Refraction Error
- What is being tested?
- Lenslet Spectacles, Violet Excitation Filter Glasses and Single Vision Lenses
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 90 participants
- Where
- 1 sitePakistan
- Study dates
- 1 Jul 2025to 6 Jun 2026
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 8 to 20 years
- All sexes
- No healthy volunteers
- Child, Adult
Who may be able to join
- Diagnosis of axial myopia (high, moderate, or severe)
- Age between 8 and 20 years (inclusive)
- Male or female
- Willingness to wear prescribed glasses as instructed
- Willingness to attend all follow-up visits (3, 6, and 9 months)
- Written informed consent from participant or parent/guardian for minors
Who cannot join
- Any ametropia other than axial myopia (e.g., hyperopia, astigmatism >1.50D)
- Current contact lens users
- Prior or concurrent myopia treatment other than study interventions
- Any ocular disease (e.g., cataract, glaucoma, retinal disorders)
- Any systemic disease affecting vision (e.g., diabetes, Marfan syndrome)
- History of any ocular surgery
- Allergic or physical intolerance to glasses materials
- Non-cooperative patients unwilling to comply with study procedures
Trial locations and contacts
1 site in 1 country.
Pakistan1 site
The University of Faisalabad
Faisalābad, Punjab Province, 3800
About this study
Official title: Role of Advanced Technological Approaches for Myopia Control in Myopic Patients: A Randomized Controlled Trial of Lenslet Spectacles vs. Violet Excitation Filter Glasses vs. Single Vision Lenses
Myopia, or nearsightedness, is increasing rapidly worldwide, especially in children and young adults. This study tested two advanced treatments for slowing myopia progression with one control group: special lenslet spectacles (Stellest with highly aspherical lenslet technology) and violet excitation filter glasses (wavelength 420 nm) and Single vision lenses for controls. The study enrolled 90 participants aged 8 to 20 years from schools and universities in Faisalabad, Pakistan. Participants were randomly assigned to one of three groups: lenslet spectacles, violet filter glasses, or single vision lenses (control group). Visual acuity, contrast sensitivity, Spherical Equivalent and axial length were measured at the start and again after 3, 6, and 9 months and one follow up after cessation of treatment. The study aimed to determine whether these advanced technologies can effectively slow myopia progression compared to standard glasses, providing head-to-head evidence on emerging and established optical interventions for myopia control.
Read the detailed description
This is a randomized controlled trial (RCT) with three parallel groups. The study was conducted at schools and the Universities in Faisalabad, Pakistan. The total study duration was almost one year (July 2025 to May 2026), with each participant undergoing atleast 3 months of active treatment with 3 follow ups. The sample size was 30 participants per group (total N=90), after drop put of patients, calculated using G*Power (repeated measures ANOVA, 3 groups × 4 time points, medium effect size f=0.25, α=0.05, power=0.8). Simple random sampling was used, with participants allocated to groups using an online research randomizer. Inclusion criteria: axial myopia (high, moderate, or severe), age 8-20 years, both genders, willingness to wear glasses. Exclusion criteria:
other ametropia, contact lens users, prior myopia treatment, ocular or systemic disease, ocular surgery, non-cooperative patients. Lenslet group: Essilor Stellest spectacles with Highly Aspheric Lenslet Target technology, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating; worn all waking hours. Violet filter group: plastic lenses with 420nm violet excitation filter; worn 3 hours daily (11 AM to 2 PM) to align with circadian rhythm. Control group: single vision lenses (refractive index 1.56). Primary outcome measures: change in axial length (measured by ocular biometer) and change in cycloplegic refraction. Secondary outcome measures: visual acuity (LogMAR chart), contrast sensitivity (Vistech chart). Follow-up assessments at 3, 6, and 9 months. Statistical analysis: repeated measures Linear mixed model using SPSS version 26 to compare within-group and between-group changes.
- Conditions
- Myopia (Disorder), Refraction Error
- Being tested
- Lenslet Spectacles, Violet Excitation Filter Glasses, Single Vision Lenses
- Keywords
- Axial Elongation, Lenslet, Violet Excitation Filter, HALT Technology, Myopia Control
- Medical subject headings
- Myopia, Refractive Errors
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Lenslet SpectaclesDevice
The lenslet spectacles are specially designed spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) technology manufactured by Essilor International (Serial Number: 72426930). The lens design includes a clear distance zone in the center with peripheral areas providing single vision correction. Technical specifications: 5H green covering, multi-dimensional pattern, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating. Participants are instructed to wear the spectacles throughout all waking hours. Each participant receives a new pair at baseline. No adjustments are made during the 12-month treatment period unless vision changes require prescription update.
Violet Excitation Filter GlassesDevice
The violet excitation filter glasses are prescription glasses incorporating a violet light filter with wavelength 420 nm (range 360-420 nm). Material: CR-39. Filter intensity: 700 nm. Wavelength verified using spectrophotometer (standard error ±0.1 to 1 nm). Participants are instructed to wear the glasses for 3 hours daily, specifically from 11 AM to 2 PM, to optimize impact on circadian rhythm while avoiding disruption of sleep patterns. Each participant receives a new pair at baseline. The filter is integrated into the prescription lenses.
Single Vision LensesDevice
Standard single vision spectacle lenses (SVS index 1.56) with no myopia control features. These are conventional prescription glasses that correct refractive error but do not incorporate lenslet technology or violet filtering. Participants are instructed to wear the glasses throughout all waking hours. Each participant receives a new pair at baseline.
| Study group | Role | What they receive |
|---|---|---|
| Lenslet Spectacles (HALT Technology | Experimental | Participants receive Essilor Stellest spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) anf violet filter glasses technology. Lenses have 1.6mm thickness, refractive index 1.56, UV 400. Participants are instructed to wear glasses throughout all waking hours for 9 months and for VF atleast 3ours. Receives: Device: Lenslet Spectacles |
| Violet Excitation Filter Glasses | Experimental | Participants receive prescription glasses with violet excitation filter (420 nm wavelength, CR-39 material). Participants are instructed to wear glasses for 3 hours daily (11 AM to 2 PM) for 12 months to align with circadian rhythm. Receives: Device: Violet Excitation Filter Glasses |
| Single Vision Lenses | Active comparator | Participants receive standard single vision spectacle lenses (SVS index 1.56). Participants are instructed to wear glasses throughout all waking hours for 12 months. Receives: Device: Single Vision Lenses |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in Axial Length
Axial length (mm) measured using an A-SCAN biometer (Scanmate 677AB). The measurement represents the distance from the corneal apex to the retinal pigment epithelium. Three measurements are taken for each eye and averaged. This is a continuous anatomical measurement with no theoretical minimum or maximum score. Higher values indicate greater ocular elongation, which is associated with worsening myopia progression.
Measured: Baseline, Month 3, Month 6, Month 9
Change in Cycloplegic Refraction
Cycloplegic spherical equivalent refraction (SER), measured in diopters (D) using retinoscopy (Welch Allyn) after cycloplegia. SER is calculated as sphere + (cylinder/2). This is a continuous measurement with no theoretical minimum or maximum value. A decrease in SER (more negative values) reflects progression of myopia, while an increase in SER (less negative or more positive values) reflects reduced myopia or a shift toward hyperopia.
Measured: Baseline, Month 3, Month 6, Month 9
Secondary outcomes (2)
Change in Visual Acuity
Visual acuity measured using the Logarithm of the Minimum Angle of Resolution (LogMAR) Visual Acuity Chart (Precision Vision) at 4 m, 2 m, and 1 m. LogMAR scores typically range from approximately -0.30 (better visual acuity) to 1.60 (poorer visual acuity), although values may extend beyond these limits. Lower scores represent better visual acuity outcomes, and higher scores represent worse visual acuity outcomes.
Measured: Baseline, Month 3, Month 6, Month 9
Change in Contrast Sensitivity
Contrast sensitivity measured using the Vistech Contrast Sensitivity Test Chart (Precision Vision) at 1 meter. Contrast sensitivity scores are reported in log contrast sensitivity units and typically range from 0.00 to approximately 2.25. Higher scores represent better contrast sensitivity and visual performance, while lower scores represent poorer contrast sensitivity and visual performance.
Measured: Baseline, Month 3, Month 6, Month 9
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted12 Jun 2026
- Study start1 Jul 2025
- Primary completion30 May 2026
- Study completion6 Jun 2026
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Myopia (Disorder)Studies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 90 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Faisalabad
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Dr Memoona Arshad, University of Faisalabad
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07645183
- Sponsor's protocol ID
- TUF/IRB/ 38 /25
- Acronym
- MyopiaTech
- Status last verified
- Jun 2026
- First submitted
- 8 Jun 2026
- Last updated
- 25 Jun 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 25 Jun 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Role of Advanced Technological Approaches for Myopia Control in Myopic Patients: A Randomized Controlled Trial of Lenslet Spectacles vs. Violet Excitation Filter Glasses vs. Single Vision Lenses
- ClinicalTrials.gov ID
- NCT07645183
- Acronym / sponsor ID
- MyopiaTech / TUF/IRB/ 38 /25
- Conditions
- Myopia (Disorder), Refraction Error
- Keywords
- Axial Elongation, Lenslet, Violet Excitation Filter, HALT Technology, Myopia Control
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 90 participants (actual)
- Lead sponsor
- University of FaisalabadUniversity, hospital or other
- Study start
- 1 Jul 2025 (actual)
- Primary completion
- 30 May 2026 (actual)
- Study completion
- 6 Jun 2026 (actual)
- First posted
- 12 Jun 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Myopia, or nearsightedness, is increasing rapidly worldwide, especially in children and young adults. This study tested two advanced treatments for slowing myopia progression with one control group: special lenslet spectacles (Stellest with highly aspherical lenslet technology) and violet excitation filter glasses (wavelength 420 nm) and Single vision lenses for controls. The study enrolled 90 participants aged 8 to 20 years from schools and universities in Faisalabad, Pakistan. Participants were randomly assigned to one of three groups: lenslet spectacles, violet filter glasses, or single vision lenses (control group). Visual acuity, contrast sensitivity, Spherical Equivalent and axial length were measured at the start and again after 3, 6, and 9 months and one follow up after cessation of treatment. The study aimed to determine whether these advanced technologies can effectively slow myopia progression compared to standard glasses, providing head-to-head evidence on emerging and established optical interventions for myopia control.
Detailed description
This is a randomized controlled trial (RCT) with three parallel groups. The study was conducted at schools and the Universities in Faisalabad, Pakistan. The total study duration was almost one year (July 2025 to May 2026), with each participant undergoing atleast 3 months of active treatment with 3 follow ups. The sample size was 30 participants per group (total N=90), after drop put of patients, calculated using G*Power (repeated measures ANOVA, 3 groups × 4 time points, medium effect size f=0.25, α=0.05, power=0.8). Simple random sampling was used, with participants allocated to groups using an online research randomizer. Inclusion criteria: axial myopia (high, moderate, or severe), age 8-20 years, both genders, willingness to wear glasses. Exclusion criteria:
other ametropia, contact lens users, prior myopia treatment, ocular or systemic disease, ocular surgery, non-cooperative patients. Lenslet group: Essilor Stellest spectacles with Highly Aspheric Lenslet Target technology, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating; worn all waking hours. Violet filter group: plastic lenses with 420nm violet excitation filter; worn 3 hours daily (11 AM to 2 PM) to align with circadian rhythm. Control group: single vision lenses (refractive index 1.56). Primary outcome measures: change in axial length (measured by ocular biometer) and change in cycloplegic refraction. Secondary outcome measures: visual acuity (LogMAR chart), contrast sensitivity (Vistech chart). Follow-up assessments at 3, 6, and 9 months. Statistical analysis: repeated measures Linear mixed model using SPSS version 26 to compare within-group and between-group changes.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 3
| Arm | Type | Receives |
|---|---|---|
| Lenslet Spectacles (HALT Technology | Experimental | Device: Lenslet SpectaclesParticipants receive Essilor Stellest spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) anf violet filter glasses technology. Lenses have 1.6mm thickness, refractive index 1.56, UV 400. Participants are instructed to wear glasses throughout all waking hours for 9 months and for VF atleast 3ours. |
| Violet Excitation Filter Glasses | Experimental | Device: Violet Excitation Filter GlassesParticipants receive prescription glasses with violet excitation filter (420 nm wavelength, CR-39 material). Participants are instructed to wear glasses for 3 hours daily (11 AM to 2 PM) for 12 months to align with circadian rhythm. |
| Single Vision Lenses | Active comparator | Device: Single Vision LensesParticipants receive standard single vision spectacle lenses (SVS index 1.56). Participants are instructed to wear glasses throughout all waking hours for 12 months. |
Who may qualify
- Ages
- 8 to 20 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult
Key inclusion criteria (6 listed)
- Diagnosis of axial myopia (high, moderate, or severe)
- Age between 8 and 20 years (inclusive)
- Male or female
- Willingness to wear prescribed glasses as instructed
- Willingness to attend all follow-up visits (3, 6, and 9 months)
Key exclusion criteria (8 listed)
- Any ametropia other than axial myopia (e.g., hyperopia, astigmatism >1.50D)
- Current contact lens users
- Prior or concurrent myopia treatment other than study interventions
- Any ocular disease (e.g., cataract, glaucoma, retinal disorders)
- Any systemic disease affecting vision (e.g., diabetes, Marfan syndrome)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Lenslet SpectaclesThe lenslet spectacles are specially designed spectacle lenses featuring HALT (Highly Aspheric Lenslet Target) technology manufactured by Essilor International (Serial Number: 72426930). The lens design includes a clear distance zone in the center with peripheral areas providing single vision correction. Technical specifications: 5H green covering, multi-dimensional pattern, 1.6mm thickness, refractive index 1.56, UV 400nm protection, antireflective coating. Participants are instructed to wear the spectacles throughout all waking hours. Each participant receives a new pair at baseline. No adjustments are made during the 12-month treatment period unless vision changes require prescription update. | Device | Lenslet Spectacles (HALT Technology |
| Violet Excitation Filter GlassesThe violet excitation filter glasses are prescription glasses incorporating a violet light filter with wavelength 420 nm (range 360-420 nm). Material: CR-39. Filter intensity: 700 nm. Wavelength verified using spectrophotometer (standard error ±0.1 to 1 nm). Participants are instructed to wear the glasses for 3 hours daily, specifically from 11 AM to 2 PM, to optimize impact on circadian rhythm while avoiding disruption of sleep patterns. Each participant receives a new pair at baseline. The filter is integrated into the prescription lenses. | Device | Violet Excitation Filter Glasses |
| Single Vision LensesStandard single vision spectacle lenses (SVS index 1.56) with no myopia control features. These are conventional prescription glasses that correct refractive error but do not incorporate lenslet technology or violet filtering. Participants are instructed to wear the glasses throughout all waking hours. Each participant receives a new pair at baseline. | Device | Single Vision Lenses |
Primary outcome
Change in Axial Length
Time frame: Baseline, Month 3, Month 6, Month 9
Axial length (mm) measured using an A-SCAN biometer (Scanmate 677AB). The measurement represents the distance from the corneal apex to the retinal pigment epithelium. Three measurements are taken for each eye and averaged. This is a continuous anatomical measurement with no theoretical minimum or maximum score. Higher values indicate greater ocular elongation, which is associated with worsening myopia progression.
Change in Cycloplegic Refraction
Time frame: Baseline, Month 3, Month 6, Month 9
Cycloplegic spherical equivalent refraction (SER), measured in diopters (D) using retinoscopy (Welch Allyn) after cycloplegia. SER is calculated as sphere + (cylinder/2). This is a continuous measurement with no theoretical minimum or maximum value. A decrease in SER (more negative values) reflects progression of myopia, while an increase in SER (less negative or more positive values) reflects reduced myopia or a shift toward hyperopia.
2 secondary outcomes
Change in Visual Acuity
Time frame: Baseline, Month 3, Month 6, Month 9
Change in Contrast Sensitivity
Time frame: Baseline, Month 3, Month 6, Month 9
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 25 Jun 2026.
- Related InfoLink provided by the sponsor.
- Individual participant dataSharing planned: No
Related trials for Myopia (Disorder)
Recruiting
Managing Premyopia in Chinese Children Using Artificial Intelligence Assisted Defocus Incorporated Multiple Segments Based Spectacle Lens: a Randomized Controlled Clinical Trial
Pre-myopia, Myopia
Not yet recruiting
BRIGHT-LIGHT: Studying Red Light Therapy for Severe Short-Sightedness or Short-Sightedness That Worsens Despite Standard Treatment
Myopia, Myopia Progressing
Not yet recruiting
Clinical Performance and Outcomes After Toric Lens Transition
Astigmatism
Recruiting
Evaluation of a New Laser Refractive Vision Correction Using the TENEO™ 317 Model 2
Hyperopia and Myopia
Not yet recruiting
The EYERISING Study
Myopia, Astigmatism
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Lenslet Spectacles, Violet Excitation Filter Glasses and Single Vision Lenses in people with Myopia (Disorder) and Refraction Error, run by University of Faisalabad at 1 site in Pakistan.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 25 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Pakistan. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in Axial Length (time frame: Baseline, Month 3, Month 6, Month 9). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Jun 2026.