AzTrials
AzTrials

Mitral Regurgitation (MR)NCT07655505

Use of Force Feedback Instruments With the da Vinci Surgical System, Model IS5000 for Mitral Valve Repair

A study testing Mitral Valve Repair including the use of Force Feedback instruments in people with Mitral Regurgitation (MR), run by Intuitive Surgical at 3 sites in United States.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record

Search all trials

Trial summary

This study aims to test the safety and effectiveness of Force Feedback instruments used during robotic-assisted mitral valve repair with the da Vinci Surgical System, Model IS5000 (dV5). Read more about this study

Who is it for?
Ages 22 years and older
Conditions the study is for
Mitral Regurgitation (MR)
What is being tested?
Mitral Valve Repair including the use of Force Feedback instruments
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
3 sitesUnited States
Study dates
6 Jul 2026to Jun 2027
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 22 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥22 years.
  • Subjects with mitral regurgitation (MR) resulting from primary (degenerative) etiology with normal ventricular function (left ventricular function > 40%) provided that annuloplasty or ventricular repair is feasible robotically.
  • Subjects with moderate-severe (Grade 3) or severe (Grade 4) mitral regurgitation (MR) confirmed by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE) within 60 days of surgery or evaluation for surgery.
  • Subjects with low-moderate operative risk (Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score of <4%).
  • Subjects that are able to provide written informed consent using the study informed consent form prior to the study.
  • Subjects that are willing to comply with protocol-specified follow-up visits.
  • Subjects must be candidates for minimally invasive surgery (no contraindications to robotic approach). Based on the study Investigator's clinical judgement, the Subject is deemed suitable to undergo multiport robotic-assisted surgery for mitral valve repair.

Who cannot join

  • PREOPERATIVE EXCLUSION CRITERIA:
  • Subjects with symptomatic mitral regurgitation determined to be at prohibitive risk for mitral valve surgery.
  • Subjects with previous mitral valve surgery, transcatheter repair, or annuloplasty.
  • Subjects with prior cardiac surgery (endoscopic, open, or robotic) or ipsilateral thoracic surgery (open, endoscopic, or robotic).
  • Subjects with planned emergent procedure (e.g., cardiogenic shock, acute decompensation requiring immediate surgery).
  • Subjects requiring surgery with multiple stages (i.e., mitral repair cannot be completed in a single procedure).
Show all 23Show fewer
  • Subject with planned major concomitant surgery for a different medical condition (e.g., coronary artery bypass, cancer resection unrelated to mitral regurgitation).
  • Subjects with non-reparable anatomy.
  • Subjects with severe pulmonary hypertension (systolic Pulmonary Artery Pressure >70 mmHg).
  • Subjects with severe renal insufficiency (estimated Glomerular Filtration Rate <30 mL/min/1.73m²) or liver failure (Child-Pugh C).
  • Subjects with active infection.
  • Subjects with contraindication to anesthesia/surgery (e.g., severe frailty, uncorrectable coagulopathy).
  • Subjects with any past or ongoing condition, or personal circumstance, that in the Investigator's judgment places the Subject at high surgical risk, deems them unsuitable for mitral valve repair, or might interfere with study participation or data collection (e.g., severe chronic obstructive pulmonary disease, uncontrolled diabetes, immunocompromised state, non-compliance).
  • Subjects with severe aortic/tricuspid valve disease requiring concurrent open surgery.
  • Subjects who are pregnant, suspected pregnancy, or breastfeeding.
  • Subjects currently participating in another investigational drug/device study or participation in a significant-risk investigational device study within the past 6 months.
  • Subject with inability to complete follow-up (e.g., geographic inaccessibility, dementia).
  • Subjects who belong to a vulnerable population (e.g., prisoners, cognitively impaired individuals unable to consent).
  • INTRAOPERATIVE EXCLUSION CRITERIA:
  • Subject with hemodynamic or respiratory instability that precludes the Investigator from performing the Robotic Assisted Surgery (RAS).
  • Subject in whom inadequate visualization makes a minimally invasive approach not feasible, as determined by the Investigator assessment prior to docking the robot.
  • Subject with adhesions, scarring, and disease status in the body which, in the opinion of the investigator, limits the ability to perform the minimally invasive procedure.
  • Subject has any other condition that, in the judgment of the Investigator, might interfere with the collection of complete quality data.

Trial locations and contacts

3 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Manish Bharara contact

manish.bharara@intusurg.com

United States3 sites, 3 recruiting
  • Emory University

    Atlanta, Georgia, 30342

    Clinical Study Coordinator, OCR@Emory.edu

    Douglas Murphy, MD

    Recruiting
  • NYU Langone Health

    New York, New York, 10016

    Jackie Bott, RN, 212-263-2268, Jacqueline.Bott@nyulangone.org

    Didier Loulmet, MD

    Recruiting
  • Providence Sacred Heart Medical Center

    Spokane, Washington, 99204

    Lauren Study Coordinator, 509-474-4345, lauren.wilcox@providence.org

    Justin Reeves, MD

    Recruiting

Other trials in United States

About this study

Official title: A Prospective, Multicenter Clinical Investigation of the Use of Force Feedback Instruments With the da Vinci Surgical System, Model IS5000 for Mitral Valve Repair (MVr)

This study aims to test the safety and effectiveness of Force Feedback instruments used during robotic-assisted mitral valve repair with the da Vinci Surgical System, Model IS5000 (dV5).

Being tested
Mitral Valve Repair including the use of Force Feedback instruments
Keywords
Mitral Valve Regurgitation, Mitral Valve Disorder, Mitral Regurgitation
Medical subject headings
Mitral Valve Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Mitral Valve Repair including the use of Force Feedback instrumentsDevice

    Robotic-assisted mitral valve repair including the use of Force Feedback instruments

Study groups in NCT07655505
Study groupRoleWhat they receive
Mitral valve repair including the use of force feedback instrumentsExperimentalPatients with moderate-severe or severe mitral regurgitation resulting from primary (degenerative) etiology who are candidates for robotic-assisted mitral valve repair.
Receives: Device: Mitral Valve Repair including the use of Force Feedback instruments

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Incidence of major adverse events

    The primary safety endpoint will be evaluated by the incidence of major (Clavien-Dindo Grade III or higher) adverse events related to the use of Force Feedback instruments during robotic-assisted mitral valve repair.

    Measured: 30 days postoperative

  2. Residual Mitral Regurgitation Grade on a Transthoracic Echocardiogram (TTE)

    The primary effectiveness endpoint will be evaluated as residual mitral regurgitation of moderate (Grade 2) or less measured by an echocardiogram after robotic-assisted mitral valve repair.

    Measured: Postoperative Day 2-7

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Jun 2026
  2. Study start6 Jul 2026
  3. Primary completion31 Dec 2026 (estimated)
  4. Study completionJun 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07655505
Sponsor's protocol ID
ISI dV5 MVr-01
Status last verified
Aug 2026
First submitted
10 Jun 2026
Last updated
14 Sep 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in