AzTrials
AzTrials

Aneurysm of Aorta, ThoracicNCT07691931

TBE Zone 0/1 PMS in Japan

An observational study of Aneurysm of Aorta, Thoracic and Dissection of Aorta, Thoracic, run by W.L.Gore & Associates.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this surveillance is to confirm the safety and efficacy of TBE under actual use in the Zone 0/1 lesion on post-marketing usage conditions. Read more about this study

Who is it for?
Any age
What is being tested?
Gore® TAG® Thoracic Aortic Branch Stent Graft System
Type of treatment
Medical device
How many people
75 participants
Where
No sites listed yet
Study dates
Sep 2026to Sep 2035
Phase
Observational
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Study population: Patients who attempted implant of TBE in Zone 0/1 during the enrollment period for each indication (including patients in whom TBE is not placed in Zone 0/1 area).

Who may be able to join

  • Those who are suitable for use of TBE according to the Japan package insert. [Reference: Purpose of Use or Effects of TBE at the time of launch] The GORE® TAG® Thoracic Branch Endoprosthesis is intended for use in patients with the following diseases of the aortic arch and descending thoracic aortic lesions who fulfill anatomical requirements for treatment of such diseases while preserving blood flow to a single aortic arch target branch vessel.
  • Thoracic aortic aneurysm
  • Traumatic transection
  • Complicated Stanford type A (after surgical repair) and B aortic dissection (including dissecting aortic aneurysm) who have not responded to medical therapy
  • The GORE® TAG® Thoracic Branch Endoprosthesis may be used in combination with designated stent grafts with validated efficacy and safety.

Who cannot join

  • N/A

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

About this study

Official title: GORE® TAG® Thoracic Branch Endoprosthesis Zone 0/1 Post-Market Surveillance in Japan

The goal of this surveillance is to confirm the safety and efficacy of TBE under actual use in the Zone 0/1 lesion on post-marketing usage conditions.

Being tested
Gore® TAG® Thoracic Aortic Branch Stent Graft System
Medical subject headings
Aortic Aneurysm, Aortic Dissection, Wounds and Injuries

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Gore® TAG® Thoracic Aortic Branch Stent Graft SystemDevice

    Patients who attempted implant of TBE in Zone 0/1 during the enrollment period for each indication (including patients in whom TBE is not placed in Zone 0/1 area).

Study groups in NCT07691931
Study groupRoleWhat they receive
Aneurysm cohortThoracic Aortic Aneurysm: 50 patients (including at least 5 surgically repaired patients who have the proximal landing zone that is a surgical graft) Before 5 surgically repaired patients are enrolled if the other 45 patients are confirmed to be enrolled, enrollment of the other patients will be considered complete at that point, and only surgically repaired patients will continue to be enrolled.
Receives: Device: Gore® TAG® Thoracic Aortic Branch Stent Graft System
Dissection and Traumatic Transection cohort* Complicated chronic Stanford type B aortic dissection (including dissecting aneurysm): at least 10 patients, and enrollment will be considered complete when the enrollment of 15 patients is confirmed. * Complicated Stanford type A (after surgical repair) aortic dissection: at least 10 patients, and enrollment will be considered complete when the enrollment of 15 patients is confirmed. If, during the enrollment period for the dissection and traumatic transection cohort, an attempt is made to place TBE in patients with complicated acute Stanford type B aortic dissection or in patients with traumatic thoracic aortic transection, those patients will also be enrolled in the dissection and traumatic transection cohort.
Receives: Device: Gore® TAG® Thoracic Aortic Branch Stent Graft System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Device Technical Success at the Initial Endovascular Procedure

    All of the following must be met.

    • Successful access and delivery
    • Patency of devices
    • The absence of unanticipated additional procedure related to the device, the TBE implant procedure, or withdrawal of the delivery system

    Measured: TBE Initial Implant Procedure

  2. Lesion-related Mortality and All-cause Death

    Lesion-related Mortality that meet any of the following criteria:

    • All deaths within 30 days after the revascularization procedure or the TBE implant procedure during the initial hospitalization or secondary procedures resulting from the treated lesion or endovascular treatment (e.g., procedures for retrograde dissection, loss of patency, loss of device integrity, endoleak, migration, aortic dilation, aneurysm rupture)
    • All deaths related to the treated lesion or device (e.g., aneurysm rupture, retrograde dissection resulting in fatal cardiac tamponade) Not applicable if there is evidence to support no relationship to the lesion.

    Measured: 60 Months

  3. Aortic Rupture of the Treatment Lesion

    Rupture in the treated segment of the vessel (e.g., aorta or branch) verified with direct observation or CT / CTA scan.

    Measured: 60 Months

  4. Disabling Stroke

    Stroke is the acute onset of symptoms consistent with focal or multifocal central nervous system (CNS) injury caused by vascular blockage resulting in ischemia or vascular rupture resulting in hemorrhage, that:

    Persists for > 24 hours or until death

    Measured: 60 Months

  5. Serious Paraplegia

    Paraplegia secondary to spinal cord ischemia reported as a serious adverse event from sites.

    Measured: 60 Months

  6. Serious Paraparesis

    Paraparesis secondary to spinal cord ischemia reported as a serious adverse event from sites.

    Measured: 60 Months

  7. Renal Failure Requiring Dialysis

    Renal failure reported as a serious adverse event by sites and confirmed to require dialysis.

    Measured: 60 Months

  8. Additional Unanticipated Post-procedural Reintervention

    Additional unanticipated surgical procedure or endovascular procedure related to TBE, TBE implant procedure, or revascularization procedure for TBE implant after the revascularization procedure or TBE implant procedure.

    Anticipated or unanticipated status will be determined at the discretion of the investigator.

    Surgical procedures include conversion to thoracotomy. Endovascular procedures include stent graft implants for endoleaks, aortic enlargement and loss of patency, and procedures on the branch to improve or restore patency.

    Events will not include access site(s) complications, interventions to address issues related to non-treated area of the index lesion, such as bare stent implant to address bowel ischemia associated with aortic dissection.

    Measured: 60 Months

  9. Serious Device-related Ischemia

    Ischemia reported by sites as a serious adverse event determined to be related to the device.

    Measured: 60 Months

  10. Distal Device-related Thromboembolic Serious Adverse Event Requiring Intervention or Surgery

    Device-related ischemic adverse events reported by sites as serious adverse events that required bypass surgery, surgical procedures, or amputation, or that resulted in death.

    Measured: 60 Months

  11. Serious New Dissection

    New events of aortic dissection reported as serious adverse events by sites.

    Measured: 60 Months

  12. Serious Myocardial Infarction

    Myocardial infarction reported as a serious adverse event by the sites.

    Measured: 60 Months

  13. Serious Laryngeal or Phrenic Nerve Injury

    Nerve damage events reported by the sites as serious adverse events that required retreatment.

    Measured: 60 Months

  14. Serious Heart Failure/Hypotension

    Heart failure or hypotension reported as serious adverse events by the sites.

    Measured: 60 Months

  15. Aortic Enlargement in the Region Encompassed by the Initial Lesion

    An increase of 5 mm or more in arterial diameter at the treated area compared to images taken at the first follow-up after the TBE implant procedure.

    Measured: 60 Months

  16. Endoleak

    Serious adverse events reported or confirmed by imaging by the sites.

    The definitions of each type of endoleaks are as follows:

    • Type I endoleak is defined as a sealing failure at one of the attachment sites of the graft to the vessel wall. Arterial flow therefore leaks alongside the graft and into the perigraft space.
    • Type Ia: Proximal leak
    • Type Ib: Distal leak
    • Type Ic: Inadequate seal at distal landing zone for side branch component
    • Type II endoleak is defined as retrograde flow from branch arteries arising from the treated segment of the aorta.
    • Type III endoleak
    • Type IIIA endoleak : Attachment of aortic components (aortic-aortic).
    • Type IIIB endoleak : Fabric tear or disruption.
    • Type IIIC endoleak : Attachment of aortic component-side-branch or side-branch-side-branch
    • Type IV endoleak is defined as flow through porous fabric.
    • Indeterminate : Endoleak detected with unknown source.

    Measured: 60 Months

  17. Loss of Device Integrity

    Defined as any of the following:

    • Wire fractures identified in the sealing row stents of the aortic component (AC), branch component (SB) or aortic extender (AE).
    • Stent kinking: Narrowing of the stent graft associated with demonstrable angulation in any of the stent components, with demonstrable flow
    • Disruption / tears in the graft component of the stent graft
    • Transient (compression) or permanent stent-graft collapse (invagination) following complete device deployment, resulting in an overall reduction in the aortic or branch vessel luminal diameter.
    • If the device loses function due to other malformations

    Measured: 60 Months

  18. Loss of Aortic or Aortic Branch Patency

    No flow or contrast detected through the implanted aortic or side branch devices or distal CTAG devices after the TBE implant procedure.

    Measured: 60 Months

  19. Migration

    Longitudinal movement of all or part of the device for a distance ≥10 mm, as confirmed by imaging, relative to anatomical landmarks and device positioning at the first post-operative imaging.

    Measured: 60 Months

  20. False Lumen Perfusion through the Primary Entry Tear (Dissection Patients only)

    Confirm the presence or absence of blood flow from a proximal aortic source through the primary entry tear into the aortic false lumen, based on imaging.

    Measured: 60 Months

  21. Extension of a Dissection (Proximally or Distally) (Dissection Patients only)

    Among the aortic dissections reported by sites as serious adverse events, those in which proximal or distal progression of the lesion from the TBE implant procedure was confirmed on imaging.

    Measured: 60 Months

  22. False Lumen Status in Treated and Untreated Segments (Dissection Patients only)

    The thrombosis state of the false lumen at the treated and untreated segments at the TBE implant procedure is confirmed using the following three stages.

    • Patent is defined as flow present throughout the aortic false lumen in the absence of evidence of thrombus.
    • Partially thrombosed false lumen is defined as clot within the aortic false lumen that has a residual patent flow channel.
    • Thrombosed false lumen is defined as complete thrombosis of the aortic false lumen.

    Measured: 60 Months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Jul 2026
  2. Study startSep 2026 (estimated)
  3. Primary completionSep 2035 (estimated)
  4. Study completionSep 2035 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
75 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07691931
Sponsor's protocol ID
JPS 25-10
Status last verified
Jun 2026
First submitted
19 Jun 2026
Last updated
9 Jul 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Aneurysm of Aorta, Thoracic and Dissection of Aorta, Thoracic, run by W.L.Gore & Associates.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 9 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Manami Kaneko (+81-70-1433-0565, mkaneko@wlgore.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Device Technical Success at the Initial Endovascular Procedure (time frame: TBE Initial Implant Procedure). The study lists 22 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Jul 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in