AzTrials
AzTrials

Prostate Cancer Patients Treated by RadiotherapyPhase 2SIB-VMATNCT07693075

Efficacy and Safety of Simultaneous Integrated Boost Radiotherapy in HR/VHR Prostate Cancer With EPLNI

A Phase 2 study testing Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT) in people with Prostate Cancer Patients Treated by Radiotherapy, run by Ain Shams University at 3 sites in Egypt.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

The aim of this study is to evaluate the efficacy and safety of hypofractionated simultaneous integrated boost volumetric arc radiation therapy (SIB - VMAT) for high-risk and very high-risk localized prostate cancer in terms of: 1. Acute and late gastrointestinal and genitourinary toxicities. 2. Read more about this study

Who is it for?
Ages 18 years and older, men only
What is being tested?
Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT)
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
3 sitesEgypt
Study dates
1 Aug 2025to 1 Nov 2026
Phase
Phase 2
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • Men only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Histologically confirmed adenocarcinoma of the prostate.
  • Classification as High-Risk (HR) or Very High-Risk (VHR) per NCCN guidelines (e.g., T3a+, PSA > 20 ng/mL, or Gleason Score 8-10).
  • Adequate baseline urinary function (IPSS \le 20).
  • Multiparametric MRI of the prostate.
  • CT Chest, Abdomen, and Pelvis.
  • Bone scan
  • Optional: PSMA-PET/CT to definitively exclude distant metastases (M1) and provide high-fidelity nodal assessment prior to treatment planning.

Who cannot join

  • Prior pelvic radiotherapy.
  • History of Inflammatory Bowel Disease (IBD) or active severe proctitis.
  • Presence of distant metastases.

Trial locations and contacts

3 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Mohamed Alhefny, MD contact

+201228169673

Alhefny@med.asu.edu.eg

Egypt3 sites, 3 recruiting
  • Faculty of Medicine, Ain Shams University

    Cairo

    Mohamed Alhefny Almashtouly, MD, +201228169673, Alhefny@med.asu.edu.eg

    Recruiting
  • Faculty of Medicine - Menoufia University

    Shibīn al Kawm

    Ahmed Sohaib, MD, +201060406063, dr.ahmed.sohaib@gmail.com

    Recruiting
  • Faculty of Medicine - Sohag University

    Sohag

    Alshaymaa Abdelghaffar, MD, +201006828975, alshimaaahmed@med.sohag.edu.eg

    Recruiting

Other trials in Egypt

About this study

Official title: Prospective Evaluation of Efficacy and Safety of Simultaneous Integrated Boost (SIB-VMAT) Radiotherapy in HR/VHR Prostate Cancer With EPLNI

The aim of this study is to evaluate the efficacy and safety of hypofractionated simultaneous integrated boost volumetric arc radiation therapy (SIB - VMAT) for high-risk and very high-risk localized prostate cancer in terms of:

  1. Acute and late gastrointestinal and genitourinary toxicities.
  2. Evaluate the efficacy in terms of early bPFS.
  3. Dosimetric evaluation in terms of target coverage and organs at risk sparing
Read the detailed description

Background:

Despite the overwhelming success of hypofractionation for prostate-only radiotherapy, a substantial gap in high-level evidence exists regarding its application to elective pelvic lymph node irradiation. The pivotal trials establishing the 60 Gy/20 fraction standard (such as CHHiP and PROFIT) largely excluded extensive whole pelvic nodal irradiation. Consequently, there remains a lack of definitive, prospective data validating the safety and efficacy of a hypofractionated Simultaneous Integrated Boost (SIB) technique that concurrently delivers 44 Gy to the pelvic lymph nodes and 60 Gy to the prostate over 20 fractions. While modern image-guided, Volumetric Modulated Arc Therapy (VMAT) provides the dosimetric conformity required to spare organs at risk (OARs) such as the bladder and bowel, clinical confirmation of acute and late toxicities in the context of wide-field pelvic irradiation remains paramount.

Therefore, this prospective, single-arm trial is designed to address this critical evidence gap. By rigorously evaluating the GI and GU toxicity profiles and early biochemical control, this study seeks to validate the 4-week SIB protocol as a safe, efficacious, and resource-efficient standard of care for high-risk prostate cancer requiring elective pelvic nodal irradiation.

Objectives:

To evaluate the safety of hypofractionated SIB - VMAT radiation therapy in terms of acute and late GI and GU toxicities, and also evaluate the efficacy in terms of early bPFS, and lastly, dosimetric evaluation in terms of target coverage and OAR sparing Study Arms Single arm Population: Histologically confirmed localized prostatic adenocarcinoma with high and very high risk groups.

Primary Endpoint: Acute and late GIT \& GU toxicities (according to CTCAE \& RTOG).

Secondary Endpoints:

  1. To evaluate early biochemical control (serum PSA) at 6 and 12 months.
  2. To perform a dosimetric analysis of target coverage and of organs at risk (OARs) dose contains.

Significance α = 0.05 two-sided; power = 80%; minimum detectable HR = 0.65 Duration 12 months total (from IRB approval to submission of the manuscript).

Being tested
Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT)
Keywords
SIB-VMAT Radiotherapy, High risk prostate cancer

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT)Radiation

    Patients with histopathologically confirmed prostatic adenocarcinoma staged as high-risk / very high-risk localized disease will receive radiotherapy using Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT) over a total duration of 4 weeks (20 consecutive working days). Target volumes: PTV-1 (PTV 44 Gy) Prostate + Pelvic Lymph Node PTV (PLNI): 44 Gy delivered in 20 fractions (2.2 Gy/fraction), including the internal iliac, external iliac, obturator, presacral nodal stations, whole prostate, and SV. PTV-2 (PTV 60 GY): 60 Gy delivered in 20 fractions (3 Gy/fraction), including the whole prostate and the base of the SV (proximal 1 cm). Systemic Therapy is allowed during the study when indicated. Patients will receive long-term Androgen Deprivation Therapy (ADT) for a duration of 18-24 months. ADT will be initiated as neoadjuvant therapy 2-3 months prior to the commencement of radiotherapy.

Study groups in NCT07693075
Study groupRoleWhat they receive
SIB-VMAT radiation therapyExperimentalPatients with histopathologically confirmed prostatic adenocarcinoma staged as high-risk / very high-risk localized disease will receive radiotherapy using Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT) over a total duration of 4 weeks (20 consecutive working days). Target volumes: PTV-1 (PTV 44 Gy) Prostate + Pelvic Lymph Node PTV (PLNI): 44 Gy delivered in 20 fractions (2.2 Gy/fraction), including the internal iliac, external iliac, obturator, presacral nodal stations, whole prostate, and SV. PTV-2 (PTV 60 GY): 60 Gy delivered in 20 fractions (3 Gy/fraction), including the whole prostate and the base of the SV (proximal 1 cm). Systemic Therapy is allowed during the study when indicated. Patients will receive long-term Androgen Deprivation Therapy (ADT) for a duration of 18-24 months. ADT will be initiated as neoadjuvant therapy 2-3 months prior to the commencement of radiotherapy.
Receives: Radiation: Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Acute and late GIT & GU toxicity

    The incidence and severity of acute (during the radiation treatment and up to 3 months post-treatment) and late (after 3 months from finishing radiotherapy) gastrointestinal (GI) and genitourinary (GU) toxicities associated with the SIB-VMAT approach using CTCAE v5.0 and RTOG scale.

    Measured: Day 1, Day 7, Day 14, Day 20 from radiation therapy start, then week 4, week 8, week 12 from radiation therapy end.

Secondary outcomes (2)
  1. Early biochemical progression-free survival (bPFS)

    Early biochemical control in terms of the serial measurement of serum PSA levels.

    Measured: Day 1, Month 3, Month 6 and Month 12, from radiation therapy end.

  2. Dosimetric plan evaluation

    1. Dosimetric analysis of planning target volume coverage (PTV ): at least 95% of the volume must be covered with 95% of the prescribed radiation dose.
    2. Dosimetric analysis of organs at risk (OAR) dose constraints, including rectum, urinary bladder, bowel, femoral heads, and penile bulb radiation doses, according to Quantec and Chipp trial dose constraints.

    Measured: Baseline (Day 1 of radiation therapy start).

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Jul 2026
  2. Study start1 Aug 2025
  3. Primary completion1 Sep 2026 (estimated)
  4. Study completion1 Nov 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 2
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07693075
Sponsor's protocol ID
Soh-Med-26-6-12PD
Acronym
SIB-VMAT
Status last verified
Jun 2026
First submitted
28 Jun 2026
Last updated
9 Jul 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A Phase 2 study testing Simultaneous Integrated Boost Volumetric Modulated Arc Therapy (SIB-VMAT) in people with Prostate Cancer Patients Treated by Radiotherapy, run by Ain Shams University at 3 sites in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 9 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 2 studies give the treatment to a larger group to see whether it has the intended effect and to keep checking safety.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Mohamed Alhefny, MD (+201228169673, Alhefny@med.asu.edu.eg), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Acute and late GIT & GU toxicity (time frame: Day 1, Day 7, Day 14, Day 20 from radiation therapy start, then week 4, week 8, week 12 from radiation therapy end.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Jul 2026; AzTrials last refreshed its copy on 7 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in