AzTrials
AzTrials

Orthodontic Appliance ComplicationNCT07698730

Evaluation of Maxillary Buccal Miniscrew Insertion Using Digital Guides

A study testing CAD/CAM 3D-Printed Surgical Guide and Free-Hand Orthodontic Miniscrew Placement in people with Orthodontic Appliance Complication, run by Can Tho University of Medicine and Pharmacy at 1 site in Vietnam.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This randomized split-mouth clinical trial aims to compare the accuracy and clinical outcomes of CAD/CAM 3D-printed surgical guides with the conventional free-hand technique for orthodontic miniscrew placement in the posterior maxilla. Read more about this study

Who is it for?
Ages 18 to 70 yearsHealthy volunteers can take part
Conditions the study is for
Orthodontic Appliance Complication
What is being tested?
CAD/CAM 3D-Printed Surgical Guide and Free-Hand Orthodontic Miniscrew Placement
Could I receive a placebo?
No, everyone receives an active treatment
How many people
33 participants
Where
1 siteVietnam
Study dates
1 Nov 2025to 1 Jun 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 70 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Adults aged 18 years or older.
  • Patients requiring bilateral orthodontic miniscrew placement in the posterior maxilla as part of orthodontic treatment.
  • Availability of high-quality cone-beam computed tomography (CBCT) images suitable for evaluation and digital planning.
  • Good general health and ability to undergo orthodontic treatment.
  • Healthy periodontal tissues at the planned miniscrew insertion sites.
  • Ability and willingness to provide written informed consent.

Who cannot join

  • Systemic diseases or medications affecting bone healing or bone metabolism.
  • Bleeding disorders or contraindications to minor oral surgery.
  • Active periodontal disease or local infection at the planned insertion site.
  • Poor-quality or incomplete CBCT images.
  • Contraindications to CBCT imaging.
  • Pregnancy or lactation.
  • Previous orthodontic miniscrew placement in the planned insertion area.
  • Refusal or inability to provide informed consent.

Trial locations and contacts

1 site in 1 country.

Vietnam1 site
  • Can Tho University of Medicine and Pharmacy

    Can Tho, +84

Other trials in Vietnam

About this study

This randomized split-mouth clinical trial aims to compare the accuracy and clinical outcomes of CAD/CAM 3D-printed surgical guides with the conventional free-hand technique for orthodontic miniscrew placement in the posterior maxilla. Each participant will receive miniscrew placement using both techniques on opposite sides of the maxilla following random allocation. The primary outcome is placement accuracy assessed by three-dimensional positional and angular deviations between planned and actual miniscrew positions. Secondary outcomes include miniscrew stability, success rate after three months, postoperative pain, procedural time, patient satisfaction, and complications. The study also evaluates maxillary posterior cortical bone thickness using cone-beam computed tomography (CBCT) and investigates its relationship with miniscrew placement accuracy and stability

Read the detailed description

Orthodontic miniscrews have become an effective source of temporary skeletal anchorage because they provide absolute anchorage with minimal dependence on patient compliance. However, the success of orthodontic miniscrews largely depends on accurate insertion while avoiding adjacent anatomical structures, particularly dental roots and the maxillary sinus. Incorrect placement may lead to root damage, instability, or failure of the miniscrew Cone-beam computed tomography (CBCT) allows three-dimensional evaluation of alveolar bone morphology and cortical bone thickness before miniscrew insertion. Digital technologies combining CBCT, intraoral scanning, CAD/CAM planning, and three-dimensional printing have enabled fabrication of customized surgical guides designed to improve insertion accuracy This study is designed as a randomized split-mouth controlled clinical trial. Patients requiring bilateral orthodontic miniscrews in the posterior maxilla will receive one miniscrew inserted using a CAD/CAM 3D-printed surgical guide and the contralateral miniscrew inserted using the conventional free-hand technique. The side allocated to each intervention and the order of insertion will be randomized Placement accuracy will be evaluated by superimposing preoperative planning data with postoperative digital models using Geomagic Studio software. Three-dimensional deviations, including coronal and apical positional deviations and angular deviations, will be calculated. Miniscrew stability, success rate after three months, postoperative pain measured by the Visual Analog Scale (VAS), patient satisfaction, operative time, and treatment-related complications will also be evaluated. Additionally, CBCT will be used to measure cortical bone thickness at multiple posterior maxillary interradicular sites, and correlations between cortical bone thickness and miniscrew accuracy and stability will be analyzed

Being tested
CAD/CAM 3D-Printed Surgical Guide, Free-Hand Orthodontic Miniscrew Placement
Keywords
Orthodontic Miniscrew, 3D Printing, CBCT, Surgical Guide

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CAD/CAM 3D-Printed Surgical GuideDevice

    A customized tooth-supported CAD/CAM-designed and 3D-printed surgical guide fabricated from CBCT and intraoral scan data to assist accurate orthodontic miniscrew insertion in the posterior maxilla according to the preoperative digital treatment plan.

  • Free-Hand Orthodontic Miniscrew PlacementProcedure or surgery

    Orthodontic miniscrews are inserted manually using the conventional free-hand technique without the assistance of a surgical guide, based on the clinician's clinical judgment and anatomical landmarks.

Study groups in NCT07698730
Study groupRoleWhat they receive
CAD/CAM-Guided Miniscrew PlacementExperimentalMiniscrew placement using a customized CAD/CAM 3D-printed surgical guide.
Receives: Device: CAD/CAM 3D-Printed Surgical Guide
Free-Hand Miniscrew PlacementActive comparatorConventional free-hand orthodontic miniscrew placement.
Receives: Procedure: Free-Hand Orthodontic Miniscrew Placement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Accuracy of Orthodontic Miniscrew Placement

    Placement accuracy will be assessed by comparing the planned and actual miniscrew positions using digital superimposition. Coronal and apical three-dimensional deviations together with angular deviations will be calculated using Geomagic Studio software.

    Measured: Immediately after miniscrew placement

Secondary outcomes (3)
  1. Miniscrew Success Rate

    Clinical success defined as stable miniscrews remaining functional for orthodontic anchorage.

    Measured: 3 months

  2. Miniscrew Stability

    Clinical assessment of miniscrew stability after insertion.

    Measured: Immediately after insertion, 1 week, 1 month, and 3 months.

  3. Three-Dimensional Miniscrew Displacement

    Changes in miniscrew position between immediate postoperative and 3-month evaluations

    Measured: 3 months.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Jul 2026
  2. Study start1 Nov 2025
  3. Primary completion1 Jun 2026
  4. Study completion1 Jun 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Single blind
Who is masked
Participant
Enrolment
33 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07698730
Sponsor's protocol ID
LeNguyenLam
Status last verified
Jul 2026
First submitted
7 Jul 2026
Last updated
13 Jul 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing CAD/CAM 3D-Printed Surgical Guide and Free-Hand Orthodontic Miniscrew Placement in people with Orthodontic Appliance Complication, run by Can Tho University of Medicine and Pharmacy at 1 site in Vietnam.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 13 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Vietnam. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Accuracy of Orthodontic Miniscrew Placement (time frame: Immediately after miniscrew placement). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Jul 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in