AzTrials
AzTrials

Orthodontic RelapseNCT07730476

3D-Printed vs Conventional Fixed Retainers After Orthodontic Treatment

A study testing Conventional Multistranded Stainless Steel Fixed Retainer, 3D-Printed Cobalt-Chromium Fixed Retainer and 3D-Printed Titanium Fixed Retainer in people with Orthodontic Relapse and Malocclusion, run by Minia University.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

This randomized clinical trial aims to compare the clinical performance of two types of three-dimensionally printed fixed retainers (Cobalt-Chromium and Titanium Grade 5) with the conventional multistranded stainless steel fixed retainer following orthodontic treatment. Read more about this study

Who is it for?
Ages 21 to 35 yearsHealthy volunteers can take part
Conditions the study is for
Orthodontic Relapse, Malocclusion
What is being tested?
Conventional Multistranded Stainless Steel Fixed Retainer, 3D-Printed Cobalt-Chromium Fixed Retainer and 3D-Printed Titanium Fixed Retainer
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
36 participants
Where
No sites listed yet
Study dates
1 Aug 2026to 1 Sep 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 to 35 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Age range 21-35 years old after finishing orthodontic treatment.
  • Presence of all maxillary and mandibular anterior teeth with normal shape and size.
  • Completion of orthodontic treatment with full fixed appliances.

Who cannot join

  • Patients with cleft lip and/or palate or any other craniofacial syndrome
  • Patients with compromised oral hygiene or periodontal disease
  • Patients who had orthognathic surgery
  • Lingual appliance treatments
  • Enamel hypoplasia, fluorosis, active caries, restorations, or fractures in the anterior teeth
  • Patients who had separate arch debondings with a difference of more than 2 months in-between jaws

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Salma A Daabis, BDS contact

+201066600270

salma.daabis@pua.edu.eg

Ahmed Sh Hashem, Professor contact

+201002024437

ahmedshawkydent@yahoo.com

About this study

Official title: Comparison Between Three-Dimensionally Printed Fixed Retainers Versus Conventional Multistranded Stainless Steel Fixed Retainers: Randomized Clinical Trial

This randomized clinical trial aims to compare the clinical performance of two types of three-dimensionally printed fixed retainers (Cobalt-Chromium and Titanium Grade 5) with the conventional multistranded stainless steel fixed retainer following orthodontic treatment. Thirty-six participants will be randomly allocated into three parallel groups with a 1:1:1 allocation ratio. The primary outcome is post-treatment stability assessed by Little's Irregularity Index and lower arch dimensions. Secondary outcomes include bond failure rate and periodontal parameters over a 12-month follow-up period.

Read the detailed description

Orthodontic relapse remains one of the greatest challenges following the completion of orthodontic treatment. Conventional multistranded stainless steel fixed retainers are considered the gold standard for long-term retention; however, they have several limitations, including operator-dependent adaptation, prolonged chairside time, structural instability, and possible unwanted tooth movement.

Advances in digital dentistry have introduced CAD/CAM technology and additive manufacturing (3D printing), enabling the fabrication of customized fixed retainers with improved adaptation and manufacturing accuracy. Three-dimensional printed retainers fabricated from Cobalt-Chromium (Co-Cr) and Titanium Grade 5 (Ti-6Al-4V) alloys may provide superior mechanical properties, greater manufacturing precision, and potentially improved clinical performance compared with conventional retainers.

Being tested
Conventional Multistranded Stainless Steel Fixed Retainer, 3D-Printed Cobalt-Chromium Fixed Retainer, 3D-Printed Titanium Fixed Retainer
Keywords
Orthodontic retention, Fixed retainer, 3D-printed retainer, Cobalt-Chromium, Titanium, Multistranded stainless steel retainer, Randomized clinical trial, Little's Irregularity Index
Medical subject headings
Malocclusion

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Conventional Multistranded Stainless Steel Fixed RetainerDevice

    Conventional 0.0215-inch six-stranded stainless steel bonded fixed retainer.

  • 3D-Printed Cobalt-Chromium Fixed RetainerDevice

    Customized 3D-printed cobalt-chromium bonded fixed retainer fabricated from intraoral scans.

  • 3D-Printed Titanium Fixed RetainerDevice

    Customized 3D-printed titanium (Ti-6Al-4V) bonded fixed retainer fabricated from intraoral scans.

Study groups in NCT07730476
Study groupRoleWhat they receive
Conventional Stainless Steel Fixed RetainerExperimentalParticipants receive a conventional multistranded stainless steel fixed retainer bonded after orthodontic debonding.
Receives: Device: Conventional Multistranded Stainless Steel Fixed Retainer
3D-Printed Cobalt-Chromium Fixed RetainerExperimentalParticipants receive a customized 3D-printed cobalt-chromium fixed retainer bonded after orthodontic debonding
Receives: Device: 3D-Printed Cobalt-Chromium Fixed Retainer
3D-Printed Titanium Fixed RetainerExperimentalParticipants receive a customized 3D-printed titanium (Ti-6Al-4V) fixed retainer bonded after orthodontic debonding.
Receives: Device: 3D-Printed Titanium Fixed Retainer

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Orthodontic stability assessed using Little's Irregularity Index

    Orthodontic stability will be assessed using Little's Irregularity Index on digital models. The Little's Irregularity Index ranges from 0 mm to higher positive values. A score of 0 mm indicates perfect alignment. Higher scores indicate greater relapse, whereas lower scores indicate better orthodontic stability.

    Measured: 12 months

Secondary outcomes (5)
  1. Retainer failure rate

    Assessment of the failure rate of conventional stainless steel, 3D-printed cobalt-chromium, and 3D-printed titanium fixed retainers.

    Measured: 12 months

  2. Plaque Index (Silness and Löe Plaque Index)

    Dental plaque accumulation will be assessed using the Silness and Löe Plaque Index, which is scored from 0 to 3:

    0: No plaque

    1. A film of plaque detectable by probe
    2. Moderate plaque accumulation
    3. Abundant plaque accumulation

    Lower scores indicate better oral hygiene.

    Measured: 12 months

  3. Gingival Index (Löe and Silness Gingival Index)

    Gingival inflammation will be assessed using the Löe and Silness Gingival Index, which is scored from 0 to 3:

    0: Normal gingiva

    1. Mild inflammation
    2. Moderate inflammation
    3. Severe inflammation

    Lower scores indicate better gingival health.

    Measured: 12 months

  4. Bleeding on Probing (BOP)

    Assessment of bleeding on probing as an indicator of gingival inflammation. Bleeding on probing will be assessed as the percentage of bleeding sites (0-100%). Lower percentages indicate better periodontal health.

    Measured: 12 months

  5. Probing Pocket Depth (PPD)

    Assessment of periodontal pocket depth using a periodontal probe. Pocket depth will be recorded in millimeters (mm). Lower values indicate better periodontal health.

    Measured: 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Jul 2026
  2. Study start1 Aug 2026 (estimated)
  3. Primary completion1 Aug 2027 (estimated)
  4. Study completion1 Sep 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Participants will be randomly assigned in a 1:1:1 ratio into three parallel groups to receive either a conventional multistranded stainless steel fixed retainer, a 3D-printed Cobalt-Chromium fixed retainer, or a 3D-printed Titanium Grade 5 fixed retainer.
Masking
None (open label)
Enrolment
36 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07730476
Sponsor's protocol ID
SDD-RCT-2026-01
Status last verified
Jul 2026
First submitted
7 Jul 2026
Last updated
31 Jul 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: No plan to share individual participant data (IPD).

Questions about this trial

What is this clinical trial studying?

A study testing Conventional Multistranded Stainless Steel Fixed Retainer, 3D-Printed Cobalt-Chromium Fixed Retainer and 3D-Printed Titanium Fixed Retainer in people with Orthodontic Relapse and Malocclusion, run by Minia University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 31 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Salma A Daabis, BDS (+201066600270, salma.daabis@pua.edu.eg), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Orthodontic stability assessed using Little's Irregularity Index (time frame: 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 31 Jul 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in