ReliabilityNCT07754162
Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training
An observational study of Reliability and Ultrasound, run by Riphah International University at 1 site in Pakistan.
Trial summary
Accurate assessment of skeletal muscle morphology is important in sports physiotherapy, exercise rehabilitation, and research. B-mode ultrasonography is a non-invasive and accessible method for assessing muscle thickness; however, ultrasound-based measurements may be influenced by image acquisition, anatomical… Read more about this study
- Who is it for?
- Ages 18 to 40 years, men only
- Conditions the study is for
- Reliability, Ultrasound
- How many people
- 50 participants
- Where
- 1 sitePakistan
- Study dates
- 4 Aug 2026to 20 Sep 2026
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 40 years
- Men only
- No healthy volunteers
- Adult
Study population: Non Athletes
Who may be able to join
- Recreationally Active
Who cannot join
- Known Musculoskeletal injury
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Dr Saad Rauf, PhD contact
Pakistan1 site, 1 recruiting
- Recruiting
Faculty of Rehabilitation for Data Collection and Research Work
Islamabad, 44000
Muhammad Haris, 03437181808
About this study
Official title: Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training : A Retrospective Analysis.
Accurate assessment of skeletal muscle morphology is important in sports physiotherapy, exercise rehabilitation, and research. B-mode ultrasonography is a non-invasive and accessible method for assessing muscle thickness; however, ultrasound-based measurements may be influenced by image acquisition, anatomical landmark identification, and operator-dependent measurement procedures. Establishing inter-rater reliability is therefore essential to determine whether different assessors can obtain consistent measurements of muscle thickness from the same ultrasound images. The rectus abdominis is an important component of the abdominal musculature and contributes to trunk stabilization and functional performance during exercise. Blood flow restriction (BFR) training has gained increasing attention as a low-load exercise strategy for promoting muscular adaptations, although research has predominantly focused on peripheral limb muscles. Therefore, this study aims to evaluate the inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurements following a standardized BFR training protocol using ImageJ software. Establishing reliable measurement of rectus abdominis thickness will provide a methodological basis for future research investigating abdominal muscle morphology and adaptations in sports physiotherapy, exercise rehabilitation, and BFR-based training.
Read the detailed description
A retrospective methodological reliability study design will be employed to evaluate the inter-rater reliability of ultrasound-based measurements of rectus abdominis muscle thickness following a standardized blood flow restriction (BFR) training protocol. The study will utilize previously collected B-mode ultrasound images obtained from healthy young adult male participants who completed the original BFR training protocol. The existing dataset will be reviewed according to predefined eligibility criteria, and only ultrasound images of sufficient quality for identification and measurement of the rectus abdominis muscle will be included in the analysis.
The original BFR training protocol involved low-load resistance exercise performed under blood flow restriction. During the intervention, pneumatic cuffs were applied to the limbs, and participants performed a standardized squat exercise protocol at a low percentage of one-repetition maximum with prescribed repetitions and rest intervals. Ultrasound images of the rectus abdominis obtained according to the standardized imaging protocol will be analyzed retrospectively. The rectus abdominis was selected because it is a superficial abdominal muscle that can be visualized using B-mode ultrasonography and has relatively well-defined anatomical boundaries, allowing its thickness to be assessed using a standardized measurement procedure. Furthermore, the rectus abdominis contributes to trunk stabilization during functional and resistance exercises.
Ultrasound images will be analyzed using ImageJ software. Two independent raters will perform the measurements of rectus abdominis muscle thickness using the same standardized measurement protocol. The raters will independently identify the anatomical boundaries of the rectus abdominis and obtain linear thickness measurements from the ultrasound images. The use of a single standardized image-analysis platform and identical measurement procedures for both raters will minimize variability related to software and measurement techniques. The primary outcome will be the rectus abdominis muscle thickness measured in millimeters (mm).
Inter-rater reliability will be assessed using the Intraclass Correlation Coefficient (ICC) with a two-way random-effects model for absolute agreement and single measurements [ICC (2,1)], reported with the corresponding 95% confidence interval. ICC values below 0.50 will be interpreted as poor reliability, values from 0.50 to 0.75 as moderate reliability, values from 0.75 to 0.90 as good reliability, and values above 0.90 as excellent reliability. Absolute reliability and measurement error will additionally be assessed using the Standard Error of Measurement (SEM) and Minimal Detectable Change at the 95% confidence level (MDC95), where appropriate. Bland-Altman analysis will be performed to evaluate systematic differences and limits of agreement between the two raters. All statistical analyses will be conducted using SPSS, with the level of statistical significance set at p < 0.05.
If the ultrasound-based rectus abdominis thickness measurement demonstrates good to excellent inter-rater reliability, the findings will support the reproducibility of the standardized measurement protocol and its application in future research involving abdominal muscle morphology. The study may provide a methodological foundation for future investigations examining changes in abdominal muscle morphology following BFR and other exercise interventions, with potential relevance to sports physiotherapy, rehabilitation, and exercise science.
- Conditions
- Reliability, Ultrasound
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
| Study group | Role | What they receive |
|---|---|---|
| Retrospective BFR Cohort | Healthy active male participants who underwent a short-duration blood flow restriction (BFR) training protocol. Pre- and post-training ultrasound images of the rectus abdominis muscle were retrospectively analyzed to assess inter-rater reliability of ultrasound-based muscle thickness measurements. | |
| Group 1 | Healthy active male participants assessed before the BFR training program. Baseline B-mode ultrasound images of the rectus abdominis muscle were obtained and used for measurement of muscle thickness. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
Inter-rater reliability between two independent raters in measuring rectus abdominis muscle thickness from B-mode ultrasound images using ImageJ software.
Measured: Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.
Secondary outcomes (1)
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
Rectus abdominis muscle thickness
Measured: Pre-training and immediately post-training.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted10 Aug 2026
- Study start4 Aug 2026
- Primary completion6 Sep 2026 (estimated)
- Study completion20 Sep 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for ReliabilityStudies of the same condition, open and under way.
- More trials run by Riphah International UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Other
- Time perspective
- Retrospective
- Enrolment
- 50 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Riphah International University
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Saad Rauf, PhD, Principal investigator, Riphah International University, Isra University, Islamabad
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07754162
- Sponsor's protocol ID
- REC/MS-PT/02569
- Status last verified
- Aug 2026
- First submitted
- 5 Aug 2026
- Last updated
- 10 Aug 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 10 Aug 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Inter-Rater Reliability of Ultra Sound Based Rectus Abdominis Thickness Following Blood Flow Restriction Training : A Retrospective Analysis.
- ClinicalTrials.gov ID
- NCT07754162
- Acronym / sponsor ID
- REC/MS-PT/02569
- Conditions
- Reliability, Ultrasound
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 50 participants (estimated)
- Lead sponsor
- Riphah International UniversityUniversity, hospital or other
- Study start
- 4 Aug 2026 (actual)
- Primary completion
- 6 Sep 2026 (estimated)
- Study completion
- 20 Sep 2026 (estimated)
- First posted
- 10 Aug 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Accurate assessment of skeletal muscle morphology is important in sports physiotherapy, exercise rehabilitation, and research. B-mode ultrasonography is a non-invasive and accessible method for assessing muscle thickness; however, ultrasound-based measurements may be influenced by image acquisition, anatomical landmark identification, and operator-dependent measurement procedures. Establishing inter-rater reliability is therefore essential to determine whether different assessors can obtain consistent measurements of muscle thickness from the same ultrasound images. The rectus abdominis is an important component of the abdominal musculature and contributes to trunk stabilization and functional performance during exercise. Blood flow restriction (BFR) training has gained increasing attention as a low-load exercise strategy for promoting muscular adaptations, although research has predominantly focused on peripheral limb muscles. Therefore, this study aims to evaluate the inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurements following a standardized BFR training protocol using ImageJ software. Establishing reliable measurement of rectus abdominis thickness will provide a methodological basis for future research investigating abdominal muscle morphology and adaptations in sports physiotherapy, exercise rehabilitation, and BFR-based training.
Detailed description
A retrospective methodological reliability study design will be employed to evaluate the inter-rater reliability of ultrasound-based measurements of rectus abdominis muscle thickness following a standardized blood flow restriction (BFR) training protocol. The study will utilize previously collected B-mode ultrasound images obtained from healthy young adult male participants who completed the original BFR training protocol. The existing dataset will be reviewed according to predefined eligibility criteria, and only ultrasound images of sufficient quality for identification and measurement of the rectus abdominis muscle will be included in the analysis.
The original BFR training protocol involved low-load resistance exercise performed under blood flow restriction. During the intervention, pneumatic cuffs were applied to the limbs, and participants performed a standardized squat exercise protocol at a low percentage of one-repetition maximum with prescribed repetitions and rest intervals. Ultrasound images of the rectus abdominis obtained according to the standardized imaging protocol will be analyzed retrospectively. The rectus abdominis was selected because it is a superficial abdominal muscle that can be visualized using B-mode ultrasonography and has relatively well-defined anatomical boundaries, allowing its thickness to be assessed using a standardized measurement procedure. Furthermore, the rectus abdominis contributes to trunk stabilization during functional and resistance exercises.
Ultrasound images will be analyzed using ImageJ software. Two independent raters will perform the measurements of rectus abdominis muscle thickness using the same standardized measurement protocol. The raters will independently identify the anatomical boundaries of the rectus abdominis and obtain linear thickness measurements from the ultrasound images. The use of a single standardized image-analysis platform and identical measurement procedures for both raters will minimize variability related to software and measurement techniques. The primary outcome will be the rectus abdominis muscle thickness measured in millimeters (mm).
Inter-rater reliability will be assessed using the Intraclass Correlation Coefficient (ICC) with a two-way random-effects model for absolute agreement and single measurements [ICC (2,1)], reported with the corresponding 95% confidence interval. ICC values below 0.50 will be interpreted as poor reliability, values from 0.50 to 0.75 as moderate reliability, values from 0.75 to 0.90 as good reliability, and values above 0.90 as excellent reliability. Absolute reliability and measurement error will additionally be assessed using the Standard Error of Measurement (SEM) and Minimal Detectable Change at the 95% confidence level (MDC95), where appropriate. Bland-Altman analysis will be performed to evaluate systematic differences and limits of agreement between the two raters. All statistical analyses will be conducted using SPSS, with the level of statistical significance set at p < 0.05.
If the ultrasound-based rectus abdominis thickness measurement demonstrates good to excellent inter-rater reliability, the findings will support the reproducibility of the standardized measurement protocol and its application in future research involving abdominal muscle morphology. The study may provide a methodological foundation for future investigations examining changes in abdominal muscle morphology following BFR and other exercise interventions, with potential relevance to sports physiotherapy, rehabilitation, and exercise science.
Study design
- Observational model
- Other
- Time perspective
- Retrospective
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Retrospective BFR Cohort | – | –Healthy active male participants who underwent a short-duration blood flow restriction (BFR) training protocol. Pre- and post-training ultrasound images of the rectus abdominis muscle were retrospectively analyzed to assess inter-rater reliability of ultrasound-based muscle thickness measurements. |
| Group 1 | – | –Healthy active male participants assessed before the BFR training program. Baseline B-mode ultrasound images of the rectus abdominis muscle were obtained and used for measurement of muscle thickness. |
Who may qualify
- Ages
- 18 to 40 years
- Sex
- Male only
- Healthy volunteers
- Not accepted
- Age groups
- Adult
- Study population
- Non Athletes
Key inclusion criteria (1 listed)
- Recreationally Active
Key exclusion criteria (1 listed)
- Known Musculoskeletal injury
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
Time frame: Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.
Inter-rater reliability between two independent raters in measuring rectus abdominis muscle thickness from B-mode ultrasound images using ImageJ software.
1 secondary outcome
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement
Time frame: Pre-training and immediately post-training.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Aug 2026.
- Individual participant dataSharing planned: No
Related trials for Reliability
Not yet recruitingObservational study
Comparison of Reliability, Time Cost, and Participant Comfort of Lymphedema Assessments in Upper Extremity
Lymphedema, Upper Extremity Lymphedema
Not yet recruitingObservational study
This Multicentre Study Compares aCUP-E With Standard Electrodes During aEEG Monitoring in NICU Newborns at Risk of Encephalopathy, Assessing Recording Quality, Reliability, Ease of Use and Safety.
Encephalopathy
RecruitingObservational study
Turkish Translation, Cross-Cultural Adaptation, Validity, and Reliability of the ABILHAND-Kids Young CP Scale
Cerebral Palsy
RecruitingObservational study
Validity and Reliability of the 2-Minute Step Test in Patients With Lipedema
Lipedema
RecruitingObservational study
Product Performance Report: Evaluate Long-term Reliability & Performance of Medtronic Marketed Cardiac Therapy Products
Arrhythmia, Bradycardia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Dr Saad Rauf, PhD contact
Saad Rauf, PhD principal investigator
Riphah International University, Isra University, Islamabad
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Reliability and Ultrasound, run by Riphah International University at 1 site in Pakistan.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 10 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Pakistan. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Muhammad Haris, DPT (03437181808, harismughal5154@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Inter-rater reliability of ultrasound-based rectus abdominis muscle thickness measurement (time frame: Baseline (pre-training) and post-training ultrasound images obtained at the completion of the two-week BFR training protocol.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Aug 2026.