AzTrials
AzTrials

Normal Esophageal DistensibilityEndoFLIPNCT07754695

Measuring Normal Esophageal Flexibility in Children Using EndoFLIP

A study testing Endoluminal Functional Lumen Imaging Probe (EndoFLIP) in people with Normal Esophageal Distensibility, run by Indiana University.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Official record
Search all trials

Trial summary

This study will measure normal esophageal flexibility (distensibility) in children using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP). Children who are already undergoing anesthesia for clinically indicated colonoscopy with colonic motility catheter placement and who have no history or symptoms of… Read more about this study

Who is it for?
Ages 5 to 17 yearsHealthy volunteers can take part
Conditions the study is for
Normal Esophageal Distensibility
What is being tested?
Endoluminal Functional Lumen Imaging Probe (EndoFLIP)
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
No sites listed yet
Study dates
1 Oct 2026to 30 Sep 2028
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 5 to 17 years
  • All sexes
  • Healthy volunteers accepted
  • Child

Who may be able to join

  • Age 5 to <18 years
  • Scheduled to undergo clinically indicated colonoscopy with colonic motility catheter placement under general anesthesia
  • No upper gastrointestinal symptoms (including dysphagia, recurrent vomiting, gastroesophageal reflux, or odynophagia)
  • No history of esophageal disease or esophageal surgery
  • Parent/guardian consent and participant assent, when applicable

Who cannot join

  • Known or suspected esophageal pathology
  • Prior esophageal surgery or instrumentation
  • Anatomic upper gastrointestinal abnormalities
  • Contraindication to anesthesia or EndoFLIP catheter placement

About this study

Official title: Prospective Measurement of Normative Esophageal Distensibility Using EndoFLIP in Asymptomatic Children

This study will measure normal esophageal flexibility (distensibility) in children using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP). Children who are already undergoing anesthesia for clinically indicated colonoscopy with colonic motility catheter placement and who have no history or symptoms of esophageal disease will undergo a brief EndoFLIP measurement lasting approximately 3-5 minutes before their scheduled procedure. The information collected will help establish preliminary normal pediatric reference values for esophageal distensibility, which may improve the evaluation of children with esophageal disorders in the future.

Read the detailed description

The Endoluminal Functional Lumen Imaging Probe (EndoFLIP) is an FDA-cleared device that measures the size, pressure, and flexibility (distensibility) of the esophagus. In adults, EndoFLIP measurements are routinely used to evaluate esophageal motility disorders such as achalasia. However, normal reference values for children have not been established, and pediatric interpretation currently relies largely on adult data.

The purpose of this prospective, single-center observational study is to generate preliminary normative pediatric EndoFLIP measurements. One hundred children between 5 and younger than 18 years of age who are undergoing clinically indicated colonoscopy with colonic motility catheter placement under general anesthesia will be enrolled. Eligible participants must have no history of esophageal disease or surgery and no symptoms suggestive of upper gastrointestinal disease.

Immediately before the scheduled colonoscopy and motility catheter placement, an EndoFLIP catheter will be inserted through the mouth and positioned across the lower esophageal sphincter. Measurements of esophageal diameter, cross-sectional area, pressure, compliance, and distensibility index will be obtained at standardized balloon fill volumes (20-60 mL). The EndoFLIP assessment requires approximately 3-5 minutes and does not require an upper endoscopy or any additional anesthesia. After the measurements are completed, the catheter is removed and the planned clinical procedure proceeds as scheduled. No additional study visits or follow-up are required.

The primary objective is to establish preliminary normative pediatric values for esophageal distensibility and related biomechanical parameters. Secondary analyses will evaluate associations between EndoFLIP measurements and participant age, height, weight, and body mass index. These data are intended to improve interpretation of pediatric EndoFLIP studies and support future research and clinical care for children with esophageal disorders.

Being tested
Endoluminal Functional Lumen Imaging Probe (EndoFLIP)

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Endoluminal Functional Lumen Imaging Probe (EndoFLIP)Device

    The Endoluminal Functional Lumen Imaging Probe (EndoFLIP) is an FDA-cleared impedance planimetry device used to measure esophageal diameter, cross-sectional area, intraballoon pressure, distensibility index, and compliance. In this study, the EndoFLIP catheter is inserted orally during general anesthesia immediately before clinically indicated colonoscopy with colonic motility catheter placement. Measurements are obtained over approximately 3-5 minutes at standardized balloon fill volumes of 20-60 mL, after which the catheter is removed and the planned clinical procedure proceeds. The EndoFLIP assessment is performed solely for research purposes to establish preliminary normative pediatric esophageal biomechanical reference values.

Study groups in NCT07754695
Study groupRoleWhat they receive
Asymptomatic Children Undergoing EndoFLIP AssessmentOtherChildren 5 to younger than 18 years of age undergoing clinically indicated colonoscopy with colonic motility catheter placement under general anesthesia who have no history or symptoms of esophageal disease. Participants undergo a single 3-5 minute EndoFLIP assessment before the scheduled procedure to measure esophageal distensibility index, diameter, cross-sectional area, compliance, and pressure for development of preliminary normative pediatric reference values.
Receives: Device: Endoluminal Functional Lumen Imaging Probe (EndoFLIP)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Esophageal Distensibility

    Esophageal distensibility index measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.

    Measured: During the procedure (approximately 3-5 minutes)

  2. Esophageal Diameter

    Esophageal diameter measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.

    Measured: During the procedure (approximately 3-5 minutes)

  3. Esophageal Cross-sectional Area

    Esophageal cross-sectional area measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.

    Measured: During the procedure (approximately 3-5 minutes)

  4. Esophageal Compliance

    Esophageal compliance measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.

    Measured: During the procedure (approximately 3-5 minutes)

  5. Intraballoon Pressure

    Intraballoon pressure measured using the Endoluminal Functional Lumen Imaging Probe (EndoFLIP) at standardized balloon fill volumes of 20, 30, 40, 50, and 60 mL.

    Measured: During the procedure (approximately 3-5 minutes)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Aug 2026
  2. Study start1 Oct 2026 (estimated)
  3. Primary completion30 Sep 2028 (estimated)
  4. Study completion30 Sep 2028 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07754695
Sponsor's protocol ID
28226
Acronym
EndoFLIP
Status last verified
Sep 2026
First submitted
31 Jul 2026
Last updated
8 Sep 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes

Questions about this trial

What is this clinical trial studying?

A study testing Endoluminal Functional Lumen Imaging Probe (EndoFLIP) in people with Normal Esophageal Distensibility, run by Indiana University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 8 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Esophageal Distensibility (time frame: During the procedure (approximately 3-5 minutes)). The study lists 5 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Sep 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in