Therapeutic HypothermiaMonT HTNCT07756892
Continuous Monitoring of Body Temperature in Neonates During Therapeutic Hypothermia
An observational study of Therapeutic Hypothermia and Neonatal Hypoxic-Ischemic Encephalopathy, run by Medical University of Graz at 1 site in Austria.
Trial summary
This prospective observational pilot study aims to evaluate the feasibility, accuracy, and safety of the SteadyTemp® wireless adhesive thermometer for continuous, non-invasive body temperature monitoring in neonates undergoing therapeutic hypothermia following hypoxic-ischemic encephalopathy. Read more about this study
- Who is it for?
- Ages 3 days to 1 week
- Conditions the study is for
- Therapeutic Hypothermia, Neonatal Hypoxic-Ischemic Encephalopathy, Neonatal Thermal Management
- What is being tested?
- continous temperature measurement
- Type of treatment
- Medical device
- How many people
- 10 participants
- Where
- 1 siteAustria
- Study dates
- 5 Aug 2026to 15 Aug 2028
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 3 days to 1 week
- All sexes
- No healthy volunteers
- Child
Study population: The study population consists of term and near-term neonates (≥36+0 weeks of gestation) born at the Department of Obstetrics and Gynaecology, Medical University of Graz, Austria, who require therapeutic hypothermia for the management of hypoxic-ischemic encephalopathy. Eligible participants will be recruited during their admission to the neonatal intensive care unit after written informed consent has been obtained from their parents or legal guardians.
Who may be able to join
- Neonates born at ≥36+0 weeks of gestation.
- Clinical indication for therapeutic hypothermia.
- Written informed consent obtained from the parents or legal guardians before study measurements are initiated.
Who cannot join
- Gestational age <36+0 weeks.
- No clinical indication for therapeutic hypothermia.
- Written informed consent not obtained from the parents or legal guardians.
- Congenital malformation.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Austria1 site, 1 recruiting
- Recruiting
Medical University Graz
Graz, Styria, 8034
Gerhard Pichler, Prof., +43 316 385 80520, gerhard.pichler@medunigraz.at
About this study
Official title: Continuous Monitoring of Body Temperature in Neonates During Therapeutic Hypothermia - A Prospective Observational Pilot Study
This prospective observational pilot study aims to evaluate the feasibility, accuracy, and safety of the SteadyTemp® wireless adhesive thermometer for continuous, non-invasive body temperature monitoring in neonates undergoing therapeutic hypothermia following hypoxic-ischemic encephalopathy. Currently, body temperature during therapeutic hypothermia is monitored using an invasive rectal temperature probe, which carries risks such as tissue injury, perforation, infection, and patient discomfort.
The study will enroll ten neonates born at ≥36 weeks of gestation who require therapeutic hypothermia. During the rewarming phase of treatment, the SteadyTemp® adhesive thermometer will be applied to the right axillary area for approximately 10 hours while routine rectal temperature monitoring continues. Temperature measurements obtained with the adhesive thermometer will be compared with simultaneous rectal core temperature measurements. In addition, skin condition after removal of the adhesive patch will be assessed using the Neonatal Skin Condition Scale (NSCS) to evaluate local tolerability.
Read more
The study seeks to answer the following research questions:
Can the SteadyTemp® adhesive thermometer continuously and reliably monitor body temperature in neonates during therapeutic hypothermia? Do temperature measurements obtained with the non-invasive adhesive thermometer show sufficient agreement with standard invasive rectal temperature measurements, including temperatures below 36°C? Is prolonged application of the adhesive thermometer safe and well tolerated, without causing clinically relevant skin irritation?
The findings from this pilot study will provide preliminary evidence on the feasibility and agreement of this non-invasive monitoring method and will inform the design of larger validation studies investigating whether the SteadyTemp® adhesive thermometer could serve as a safe alternative to invasive rectal temperature monitoring during therapeutic hypothermia in neonates.
Read the detailed description
This is a prospective, single-center, observational pilot study designed to evaluate the feasibility, agreement, and safety of continuous non-invasive body temperature monitoring using the SteadyTemp® wireless adhesive thermometer in neonates undergoing therapeutic hypothermia. Therapeutic hypothermia is the standard treatment for term and near-term neonates with moderate to severe hypoxic-ischemic encephalopathy and requires precise continuous temperature monitoring to maintain a target core temperature of approximately 33.5°C. Currently, temperature control is achieved using an invasive rectal temperature probe connected to a servo-controlled cooling system. Although effective, rectal probes are associated with potential complications including tissue injury, perforation, infection, contraindications in selected clinical conditions, and increased handling of critically ill neonates.
SteadyTemp® is a wireless, skin-adherent temperature sensor that continuously records skin temperature and transfers data via near-field communication (NFC). While the device has previously demonstrated safe use in term neonates under normothermic conditions, its performance during therapeutic hypothermia has not yet been evaluated. Physiological differences between skin and core body temperature, particularly during hypothermia when peripheral perfusion is reduced, may influence measurement accuracy. This study is designed to generate preliminary clinical evidence regarding the ability of the device to track changes in body temperature during therapeutic hypothermia and to assess its suitability for future clinical use in this patient population.
Participants will undergo routine therapeutic hypothermia according to institutional clinical practice. Approximately 30 minutes before initiation of the rewarming phase, the SteadyTemp® adhesive thermometer will be applied to the right axillary region and remain in place throughout the rewarming period for approximately 7-10 hours. Routine rectal temperature monitoring will continue unchanged as part of standard clinical care. Temperature data from the SteadyTemp® sensor will be retrieved using NFC-compatible devices and documented in the case report form (CRF), while corresponding rectal temperature measurements will be extracted from the electronic medical record. Following removal of the adhesive patch, skin integrity will be assessed using the Neonatal Skin Condition Scale (NSCS) to evaluate local tolerability. No study-specific therapeutic interventions are performed beyond application of the adhesive thermometer.
As a pilot feasibility study, a convenience sample of ten participants will be enrolled. The sample size is intended to assess the technical feasibility of the monitoring protocol and to provide preliminary estimates of agreement between the non-invasive and invasive temperature measurement methods, which will inform sample size calculations for future confirmatory studies.
Data will be summarized using descriptive statistics. Continuous variables will be reported as means and standard deviations or medians and interquartile ranges, as appropriate, while categorical variables will be summarized as frequencies and percentages. Agreement between SteadyTemp® and rectal temperature measurements will be explored using Bland-Altman analysis, with estimation of the mean bias and preliminary 95% limits of agreement. Because of the exploratory nature and limited sample size, analyses will focus on descriptive rather than inferential statistics. If feasibility is demonstrated, the observed variability will be used to estimate the required sample size for subsequent validation studies.
Study data will be collected using paper-based case report forms and recorded in pseudonymized form using unique study identifiers. Personal data will be stored securely in accordance with applicable data protection regulations and archived for the legally required retention period. Double data entry verification will be performed to minimize transcription errors. Independent monitoring will be conducted according to a predefined monitoring plan to ensure protocol compliance, data quality, and protection of participant rights. Source data verification will be performed through comparison of CRF entries with original medical records, in accordance with ISO 14155, ICH-GCP (Good Clinical Practice), and institutional standard operating procedures. Study personnel will receive protocol-specific training before study initiation, and the use of the investigational device will be standardized through written standard operating procedures.
The Sponsor applies a risk-based quality management approach throughout the study. Study-specific risks will be continuously assessed and managed to ensure participant safety, data integrity, and regulatory compliance. Protocol deviations, adverse events, and device deficiencies will be documented and managed according to the clinical investigation plan and applicable Medical Device Regulation (EU) 2017/745 requirements. The study will be conducted in accordance with ISO 14155, ICH-GCP, the Declaration of Helsinki, and applicable national regulations governing clinical investigations of medical devices.
- Conditions
- Therapeutic Hypothermia, Neonatal Hypoxic-Ischemic Encephalopathy, Neonatal Thermal Management
- Being tested
- continous temperature measurement
- Keywords
- continous temperature measurement, neonate, hypothermia
- Medical subject headings
- Hypothermia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
continous temperature measurementDevice
continous temperature measurement
| Study group | Role | What they receive |
|---|---|---|
| neonate with therapeutic hypothermia | neonate with therapeutic hypothermia Receives: Device: continous temperature measurement |
What is being measured
The primary outcome is the main question the study is designed to answer.
Body temperature
Agreement between continuous body temperature measurements obtained with the SteadyTemp® adhesive thermometer and routine rectal temperature measurements during therapeutic hypothermia.
Measured: During the monitoring period of approximately 7-10 hours during the rewarming phase of therapeutic hypothermia.
Secondary outcomes (2)
Ability of the SteadyTemp® adhesive thermometer to measure temperatures below 36°C during therapeutic hypothermia.
Assessment of the performance of the SteadyTemp® adhesive thermometer for measuring body temperatures in the hypothermic range (down to approximately 33.5°C) by comparison with routine rectal temperature measurements.
Measured: Approximately 7-10 hours during the rewarming phase of therapeutic hypothermia.
Skin condition after removal of the SteadyTemp® adhesive thermometer.
Occurrence of skin irritation: Assessment of skin tolerability following approximately 10 hours of device application using the Neonatal Skin Condition Scale (NSCS).
Measured: Immediately after removal of the adhesive thermometer (approximately 10 hours after application).
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted11 Aug 2026
- Study start5 Aug 2026
- Primary completion15 Aug 2028 (estimated)
- Study completion15 Aug 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Therapeutic HypothermiaStudies of the same condition, open and under way.
- More trials run by Medical University of GrazThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Case only
- Time perspective
- Prospective
- Enrolment
- 10 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Medical University of Graz
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07756892
- Sponsor's protocol ID
- 1167/2026
- Acronym
- MonT HT
- Status last verified
- Oct 2026
- First submitted
- 5 Aug 2026
- Last updated
- 6 Oct 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 6 Oct 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Continuous Monitoring of Body Temperature in Neonates During Therapeutic Hypothermia - A Prospective Observational Pilot Study
- ClinicalTrials.gov ID
- NCT07756892
- Acronym / sponsor ID
- MonT HT / 1167/2026
- Conditions
- Therapeutic Hypothermia, Neonatal Hypoxic-Ischemic Encephalopathy, Neonatal Thermal Management
- Keywords
- continous temperature measurement, neonate, hypothermia
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 10 participants (estimated)
- Lead sponsor
- Medical University of GrazUniversity, hospital or other
- Study start
- 5 Aug 2026 (actual)
- Primary completion
- 15 Aug 2028 (estimated)
- Study completion
- 15 Aug 2028 (estimated)
- First posted
- 11 Aug 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This prospective observational pilot study aims to evaluate the feasibility, accuracy, and safety of the SteadyTemp® wireless adhesive thermometer for continuous, non-invasive body temperature monitoring in neonates undergoing therapeutic hypothermia following hypoxic-ischemic encephalopathy. Currently, body temperature during therapeutic hypothermia is monitored using an invasive rectal temperature probe, which carries risks such as tissue injury, perforation, infection, and patient discomfort.
The study will enroll ten neonates born at ≥36 weeks of gestation who require therapeutic hypothermia. During the rewarming phase of treatment, the SteadyTemp® adhesive thermometer will be applied to the right axillary area for approximately 10 hours while routine rectal temperature monitoring continues. Temperature measurements obtained with the adhesive thermometer will be compared with simultaneous rectal core temperature measurements. In addition, skin condition after removal of the adhesive patch will be assessed using the Neonatal Skin Condition Scale (NSCS) to evaluate local tolerability.
The study seeks to answer the following research questions:
Can the SteadyTemp® adhesive thermometer continuously and reliably monitor body temperature in neonates during therapeutic hypothermia? Do temperature measurements obtained with the non-invasive adhesive thermometer show sufficient agreement with standard invasive rectal temperature measurements, including temperatures below 36°C? Is prolonged application of the adhesive thermometer safe and well tolerated, without causing clinically relevant skin irritation?
The findings from this pilot study will provide preliminary evidence on the feasibility and agreement of this non-invasive monitoring method and will inform the design of larger validation studies investigating whether the SteadyTemp® adhesive thermometer could serve as a safe alternative to invasive rectal temperature monitoring during therapeutic hypothermia in neonates.
Detailed description
This is a prospective, single-center, observational pilot study designed to evaluate the feasibility, agreement, and safety of continuous non-invasive body temperature monitoring using the SteadyTemp® wireless adhesive thermometer in neonates undergoing therapeutic hypothermia. Therapeutic hypothermia is the standard treatment for term and near-term neonates with moderate to severe hypoxic-ischemic encephalopathy and requires precise continuous temperature monitoring to maintain a target core temperature of approximately 33.5°C. Currently, temperature control is achieved using an invasive rectal temperature probe connected to a servo-controlled cooling system. Although effective, rectal probes are associated with potential complications including tissue injury, perforation, infection, contraindications in selected clinical conditions, and increased handling of critically ill neonates.
SteadyTemp® is a wireless, skin-adherent temperature sensor that continuously records skin temperature and transfers data via near-field communication (NFC). While the device has previously demonstrated safe use in term neonates under normothermic conditions, its performance during therapeutic hypothermia has not yet been evaluated. Physiological differences between skin and core body temperature, particularly during hypothermia when peripheral perfusion is reduced, may influence measurement accuracy. This study is designed to generate preliminary clinical evidence regarding the ability of the device to track changes in body temperature during therapeutic hypothermia and to assess its suitability for future clinical use in this patient population.
Participants will undergo routine therapeutic hypothermia according to institutional clinical practice. Approximately 30 minutes before initiation of the rewarming phase, the SteadyTemp® adhesive thermometer will be applied to the right axillary region and remain in place throughout the rewarming period for approximately 7-10 hours. Routine rectal temperature monitoring will continue unchanged as part of standard clinical care. Temperature data from the SteadyTemp® sensor will be retrieved using NFC-compatible devices and documented in the case report form (CRF), while corresponding rectal temperature measurements will be extracted from the electronic medical record. Following removal of the adhesive patch, skin integrity will be assessed using the Neonatal Skin Condition Scale (NSCS) to evaluate local tolerability. No study-specific therapeutic interventions are performed beyond application of the adhesive thermometer.
As a pilot feasibility study, a convenience sample of ten participants will be enrolled. The sample size is intended to assess the technical feasibility of the monitoring protocol and to provide preliminary estimates of agreement between the non-invasive and invasive temperature measurement methods, which will inform sample size calculations for future confirmatory studies.
Data will be summarized using descriptive statistics. Continuous variables will be reported as means and standard deviations or medians and interquartile ranges, as appropriate, while categorical variables will be summarized as frequencies and percentages. Agreement between SteadyTemp® and rectal temperature measurements will be explored using Bland-Altman analysis, with estimation of the mean bias and preliminary 95% limits of agreement. Because of the exploratory nature and limited sample size, analyses will focus on descriptive rather than inferential statistics. If feasibility is demonstrated, the observed variability will be used to estimate the required sample size for subsequent validation studies.
Study data will be collected using paper-based case report forms and recorded in pseudonymized form using unique study identifiers. Personal data will be stored securely in accordance with applicable data protection regulations and archived for the legally required retention period. Double data entry verification will be performed to minimize transcription errors. Independent monitoring will be conducted according to a predefined monitoring plan to ensure protocol compliance, data quality, and protection of participant rights. Source data verification will be performed through comparison of CRF entries with original medical records, in accordance with ISO 14155, ICH-GCP (Good Clinical Practice), and institutional standard operating procedures. Study personnel will receive protocol-specific training before study initiation, and the use of the investigational device will be standardized through written standard operating procedures.
The Sponsor applies a risk-based quality management approach throughout the study. Study-specific risks will be continuously assessed and managed to ensure participant safety, data integrity, and regulatory compliance. Protocol deviations, adverse events, and device deficiencies will be documented and managed according to the clinical investigation plan and applicable Medical Device Regulation (EU) 2017/745 requirements. The study will be conducted in accordance with ISO 14155, ICH-GCP, the Declaration of Helsinki, and applicable national regulations governing clinical investigations of medical devices.
Study design
- Observational model
- Case only
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| neonate with therapeutic hypothermia | – | Device: continous temperature measurementneonate with therapeutic hypothermia |
Who may qualify
- Ages
- 3 days to 1 week
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
- Study population
- The study population consists of term and near-term neonates (≥36+0 weeks of gestation) born at the Department of Obstetrics and Gynaecology, Medical University of Graz, Austria, who require therapeutic hypothermia for the management of hypoxic-ischemic encephalopathy. Eligible participants will be recruited during their admission to the neonatal intensive care unit after written informed consent has been obtained from their parents or legal guardians.
Key inclusion criteria (3 listed)
- Neonates born at ≥36+0 weeks of gestation.
- Clinical indication for therapeutic hypothermia.
- Written informed consent obtained from the parents or legal guardians before study measurements are initiated.
Key exclusion criteria (4 listed)
- Gestational age <36+0 weeks.
- No clinical indication for therapeutic hypothermia.
- Written informed consent not obtained from the parents or legal guardians.
- Congenital malformation.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| continous temperature measurementcontinous temperature measurement | Device | neonate with therapeutic hypothermia |
Primary outcome
Body temperature
Time frame: During the monitoring period of approximately 7-10 hours during the rewarming phase of therapeutic hypothermia.
Agreement between continuous body temperature measurements obtained with the SteadyTemp® adhesive thermometer and routine rectal temperature measurements during therapeutic hypothermia.
2 secondary outcomes
Ability of the SteadyTemp® adhesive thermometer to measure temperatures below 36°C during therapeutic hypothermia.
Time frame: Approximately 7-10 hours during the rewarming phase of therapeutic hypothermia.
Skin condition after removal of the SteadyTemp® adhesive thermometer.
Time frame: Immediately after removal of the adhesive thermometer (approximately 10 hours after application).
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Oct 2026.
- Individual participant dataSharing planned: Undecided
Related trials for Therapeutic Hypothermia
Not yet recruiting
Hypothermic Kidney Machine Perfusion With Omnisol
End Stage Renal Disease (ESRD), Kidney Transplant
Not yet recruiting
Selective Intra-Arterial Hypothermia After Endovascular Treatment for Acute Basilar Artery Occlusion
Acute Ischemic Stroke, Basilar Artery Occlusion
RecruitingPhase 2
The PROTECT-HIE Pilot Trial
Hypoxic-ischemic Encephalopathy (HIE)
RecruitingPhase 2/3
A Study to Evaluate the Safety, Tolerability, Pharmacokinetics, and Efficacy of RLS-0071 in Newborns With Moderate or Severe Hypoxic-Ischemic Encephalopathy Undergoing Therapeutic Hypothermia
Hypoxic-Ischemic Encephalopathy
RecruitingObservational study
A Study to Evaluate Treating Watery Noses With Cryotherapy in the Clinic Setting. This is Cold Therapy, Freezing the Issues at the Back of the Nose to Ease Symptoms.
Chronic Rhinitis
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Therapeutic Hypothermia and Neonatal Hypoxic-Ischemic Encephalopathy, run by Medical University of Graz at 1 site in Austria.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 6 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Austria. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Nariae Baik-Schneditz, PhD. M.D. (+43 316 385 82677, nariae.baik@medunigraz.at), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Body temperature (time frame: During the monitoring period of approximately 7-10 hours during the rewarming phase of therapeutic hypothermia.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Oct 2026.